Records from 2016 to 2025. Most recent: inspection, 27 March 2025.
Inspection history · 20
27 March 2025
Deficiency Check · Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 8097048
11 March 2025
Hull Examination · Internal Structural Exam
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 8080845
8 August 2024
Administrative Inspection
Administrative · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7976907
29 May 2024
Internal Structural Exam · Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7905124
23 May 2023
Internal Structural Exam · Annual Inspection · In-Service Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7672137
5 April 2023
Administrative Inspection
Administrative · USCG Northeast District (dp) · USCG Northeast District (CGD-NE) · Activity 7663152
10 March 2023
Administrative Inspection · Internal Structural Exam · Hull Examination
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7644204
9 August 2022
Type not recorded
No type recorded · USCGC TAHOMA (WMEC 908) · Activity 7531268
4 April 2022
Internal Structural Exam · Deficiency Check · COI Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7418705
26 March 2021
Deficiency Check · Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7162941
9 March 2021
Hull Examination
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7157165
15 June 2020
Annual Inspection · Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6980121
14 February 2020
Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6909380
15 May 2019
Annual Inspection · Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6683978
25 March 2019
Hull Examination
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6648366
1 May 2018
Deficiency Check · Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6400606
1 March 2018
Examination of Repairs · Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6365764
10 April 2017
Internal Structural Exam · Deficiency Check · COI Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6115161
20 March 2017
Hull Examination
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6108398
18 April 2016
Deficiency Check · Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 5857322
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 27 March 2025
Resolved
Each life jacket must be marked with Type I retro-reflective material approved in 46 CFR 164.018 or other standard specified by the Commandant. Majority of adult life jackets had retro-reflective material that was very worn. Prior to 02Apr2025, 60 adult and 12 children life jackets retro-reflective material must be replaced/repaired to operate/carry passengers on board the vessel. Once the 60 adult and 12 children life jackets are repaired, the vessel can ONLY carry that amount of passengers until the remaining life jackets are repaired. Owner/Operator must also provide a repair plan for repairing the remainder of the vessel's life jackets and how soon they will accomplish this task.
46 CFR 185.604(h)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 31 March 2025
Resolution: Recieved objective evidence showing repairs were conducted on vessel's lifejacket retro tape, Rep also stated the method used to repair the lifejacket retro tape (attached).
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 27 March 2025
Resolved
Each life float must be fitted with a lifeline, pendants, two paddles, a painter, and a light. 02 of the 07 life float lights need a new battery installed.
46 CFR 180.175(d)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 April 2025
Resolved 31 March 2025
Resolution: Recieved objective evidence showing waterlight batteriers were installed and dated.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 27 March 2025
Resolved
A vessel must carry one floating waterlight. The waterlight did not have a battery in it at the time of the inspection. Battery must be installed and operator must show that waterlight operates as intended.
46 CFR 180.70(d)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 April 2025
Resolved 31 March 2025
Resolution: Recieved objective evidence showing waterlight batteriers were installed and dated.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance and inspections
Issued 27 March 2025
Resolved
The inspection and maintenance of the equipment listed in paragraph (a) of this section shall be logged or otherwise documented for review by the Coast Guard upon request. Owner/Operator was conducting maintenance on vessel's survival craft, but was not conducting it IAW manufacturer's instructions nor were they documenting the maintenance. Owner/Operator must provide CG/MI with a way to document the maintenance.
46 CFR 185.702(d)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 April 2025
Resolved 31 March 2025
Resolution: Recieved documents showing the Owner/Operator will start documenting maintenance on Life Float.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 27 March 2025
Resolved
Monthly inspections required by NFPA 10 may be conducted by the owner, operator, person-in-charge, or a designated member of the crew. Owner/Operator had the annual servicing tags on all extinguishers and was conducting monthly inspections of the extinguishers, but was not documenting the inspection. Owner/Operator must start documenting the inspection.
46 CFR 176.810(b)(ii)
Action required: 10 - Deficiency Rectified
Resolved 31 March 2025
Resolution: Recieved documents showing the Owner/Operator will start documenting maintenance on Fire Extinguishers.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 4 April 2022
Resolved
The shutoff valve at the tank shall be operable from outside the tank compartment. Shutoff valves would not fully close when operated from outside the compartment.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 April 2022
Resolved 5 April 2022
Resolution: Made repairs, tested sat
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 4 April 2022
Resolved
Dry pipe vertical exhausts are permissible if suitably insulated. Exhaust pipe not full insulated.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 April 2022
Resolved 5 April 2022
Resolution: Insulation installed.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 4 April 2022
Resolved
The hailing port of the vessel must be marked on some clearly visible exterior part of the stern of the vessel. Hailing port not marked.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 May 2022
Resolved 16 May 2022
Resolution: Hailing port marked.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 26 March 2021
Resolved
(a)(2)All wiring and cable shall be suitable for marine service and for the particular installation used. In addition, flexible or portable cords such as SO, STO, and similar types cannot be used for permanently installed wiring. Pilot house has mini refrigerator and cell phone charger plugged into surge protector portable cord.
Cite 46 CFR 183.10-20
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 9 April 2021
Resolved 28 June 2021
Resolution: [name withheld] submited electrical plans to the Coast Guard at the local level to be aproved and install new ectrcial compontes and wiring as per drawing. Hand drawing No.1 was approved and installed on vessel. Installation was inspected by Sector Boston.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 26 March 2021
Resolved
(2)Cables entering boxes or fittings shall be protected from abrasion and shall conform with the following requirements: The cable armor shall be secured to the box or fitting. Fire pump junction box wiring is missing a stuffing tube.
Cite 46 CFR 183.10-20(f)
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 9 April 2021
Resolved 2 April 2021
Resolution: Crew installed new stuffing tube on fire pump junction box.
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 26 March 2021
Resolved
(d) The discharge ends of vent pipes shall be fitted with removable flame screens or flame arresters. The flame screen shall consist of a single screen of corrosion resistant wire of at least 30x30 mesh. The flame screen or flame arrester shall be of such size and design as to prevent reduction in the net cross-sectional area of the vent pipe and permit cleaning or renewal of the flame screens or arrester elements. Port and Starboard fuel vent pipe flame screen are 30% covered with white paint.
46 CFR 182.20-35
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 9 April 2021
Resolved 2 April 2021
Resolution: Crew removed paint from port and starboard fuel vent flame screens.
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 26 March 2021
Resolved
(b)(2)Fuel lines shall be accessible, protected from mechanical injury, and effectively secured against excessive movement and vibration by the use of soft non-ferrous metal straps with no sharp edges. Where passing though bulkheads, fuel lines shall be protected by close fitting ferrules or stuffing boxes. Port Main diesel engine high pressure fuel line bracket bolt is broken causing chaffing on metallic fuel line from vibration. Fuel line supply from from Port fuel tank to Port MDE is chaffing on metal engine room centerline catwalk.
46 CFR 182.20-40
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 9 April 2021
Resolved 2 April 2021
Resolution: Crew installed chafing gear to Port MDE fuel line in engine room centerling. Crew repaied broken rivet on high pressure fuel line with nut and bolt to prevent vibration.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 26 March 2021
Resolved
Cite 46 CFR 183.01-15 (a) All electrical installations shall be to the satisfaction of the Officer in Charge, Marine Inspection. Port Main Diesel engine Jacket Water float switch cover was missing which exposed wiring.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 9 April 2021
Resolved 2 April 2021
Resolution: Crew fabricated and install a new Port Main desiel engine jacket water float switch cover.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 26 March 2021
Resolved
Cite 46 CFR 185.20-35 As appropriate for the intended voyage, all vessels must carry adequate and up-to-date- (a) Charts, (b) Sailing directions, (c) Coast Pilots, (d) Light list, (e) Notice to Mariners, (f) Tide tables, and (h) all other nautical publications necessary. Vessel did not have currant Navigation Rules publication. Navigations Charts were not updated.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 9 April 2021
Resolved 2 April 2021
Resolution: Crew found rule of the roads booklet and learned how to load current BSB navigation charts on a zip drive with all current corrections on them. Crew converted map files to run on vessels navigation software.
14 - Pollution Prevention › 144 - MARPOL Annex IV (Not Applicable to PSC Exams conducted in the U.S.) › Sewage treatment plant
Issued 26 March 2021
Resolved
33 CFR 159.7 (C) When operating on a vessel on a body of water where the discharge of untreated sewage is prohibited by the Environmental Protection Agency under 40 CFR 140.3, the operator must secure each type III device in a manner which prevents discharge of sewage. Sewage was seeping from sewage PVC piping into bilge aft of Starboard sewage holding tank.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 9 April 2021
Resolved 2 April 2021
Resolution: Crew installed double hose clams to PVC pipe hose connection ubove sewage dischage valve and cleaned.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 26 March 2021
Resolved
Cite 46 CFR 183.05-20 (C) Battery terminals shall be of the soldered type and all connections shall be made to the battery terminals with permanent type connectors. Spring clips or other temporary type clamps are not permitted. Engine room battery bank connections are made with wing nuts.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 9 April 2021
Resolved 2 April 2021
Resolution: Crew replaced wingnuts with permanent fasteners on batteries.
11 - Life Saving Appliances › N/A - No Subsystem › On board training and instructions
Issued 15 June 2020
Resolved
Placards containing instructions for donning life
jackets must be posted in conspicuous places
regularly accessible and visible to crew and
passengers. Placard should be placed on the upper
deck near the life jacket storage area.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 8 July 2020
Resolution: Operator submitted a photo of the placard posted on the vessel.
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 15 June 2020
Resolved
Each vessel that operates on the high seas must
have on board an EPIRB. The vessel's EPIRB had
an expired battery.
Condition: Damaged By Earlier Event
Action required: 10 - Deficiency Rectified
Resolved 15 June 2020
Resolution: Operator provided proof that a new battery was installed on the EPIRB on the same day as inspection.
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 15 June 2020
Resolved
The master of each vessel shall ensure that each
EPIRB must be tested monthly and that test shall be
logged or otherwise documented properly.
Condition: Damaged By Earlier Event
Action required: 10 - Deficiency Rectified
Resolved 15 June 2020
Resolution: The master was instructed on frequency of testing and logging EPIRB tests.
01 - Certificates & Documentation › 012 - Crew Certificates › Certificates for master and officers
Issued 15 June 2020
Resolved
No vessel subject to inspection will be navigated
unless it is under the direction and control of an
individual who holds an appropriate license or officer
endorsement on his or her MMC. The master did not
have his original MMC onboard the vessel.
Condition: Damaged By Earlier Event
Action required: 10 - Deficiency Rectified
Resolved 15 June 2020
Resolution: Master called someone to bring his originial MMC from home to the vessel.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 15 June 2020
Resolved
The COI must be posted under transparent material
in a conspicuous place where observation by
passengers is likely. COI was not posted in pax area.
Condition: Damaged By Earlier Event
Action required: 10 - Deficiency Rectified
Resolved 15 June 2020
Resolution: A copy was posted under transparant material in a space on main pax deck.
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 15 May 2019
Resolved
Found concentrated pits on shaft packing aluminum spool, schedule 80, (.5 inch). water intrusion was noted from the deepest pitted area. On opposite side of the same spool there is another pit concentration of approximately 1/4 inch. Make repairs to satisfaction of attending MI.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 May 2019
Resolution: Installed new spool, tested SAT
Personnel › Certificates/Documents/Licenses › License, Chief Mate
Issued 1 May 2018
Resolved
Provide proof of merchant mariner credential.
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 1 May 2018
Resolution: Received email with a copy of license.
Documentation › Logs/Records › Drug Test Records
Issued 1 May 2018
Resolved
Prove proof of enrollment in drug testing program.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 May 2018
Resolved 10 May 2018
Resolution: Received proof of drug testing program.
Operations/Management › Bilge/Bilge System Management › Control of Excess Water
Issued 1 March 2018
Resolved
Not to carry passengers until Coast Guard Marine Inspector verified operation of bilge pump, 46CFR182.510.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 April 2018
Construction/Loadline › Hull › Hull Plating
Issued 17 April 2017
Resolved
Affect temporary repair to pitting in forepeak with epoxy compound, and install electrical automatic bilge pump with audible indicator in pilot house no later than 24APR17. Permanent repair shall be completed at next haul out.
Action required: 705 - Other - as specified
Due 31 December 2017
Resolved 5 April 2018
Resolution: Temporary repair in forepeak was completed and electric automatic bilge pump installed. Bilge pump funtioned properly and audible alarm was heard in pilot house. Deficiency to remain outstanding until permanent repair made at next haul-out.
Construction/Loadline › Penetrations › Pipe Flange
Issued 10 April 2017
Resolved
Overboard discharge on port side- spool piece appears to have temporary repair; renew spool piece.
Action required: 705 - Other - as specified
Due 24 April 2017
Resolved 17 April 2017
Resolution: Renewed spool piece.
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 10 April 2017
Resolved
Renew lanyard for port side bottom lifefloat waterlight. (Restricted to daylight operations).
Action required: 705 - Other - as specified
Due 24 April 2017
Resolved 17 April 2017
Resolution: Lanyard replaced.
Accommodation/Occupational Safety › Potable Water System › General
Issued 10 April 2017
Resolved
Repair leak in fresh water tank.
Action required: 705 - Other - as specified
Due 24 April 2017
Resolved 17 April 2017
Resolution: Tank repaired.
Documentation › Markings/Placards › Warning Signs
Issued 10 April 2017
Resolved
Label emergency escape hatch.
Action required: 705 - Other - as specified
Due 24 April 2017
Resolved 17 April 2017
Resolution: Hatch labeled.
Communications › Audible Communications › Horn/Whistle
Issued 10 April 2017
Resolved
Inoperable ship's whistle.
Action required: 705 - Other - as specified
Due 24 April 2017
Resolved 17 April 2017
Resolution: Replaced whistle.
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 10 April 2017
Resolved
Provide 2017 drug and alcohol enrollment documentation.
Action required: 705 - Other - as specified
Due 24 April 2017
Resolved 17 April 2017
Resolution: Provided documentation.
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 10 April 2017
Resolved
Install life jacket stowage label on upper deck.
Action required: 705 - Other - as specified
Due 24 April 2017
Resolved 17 April 2017
Resolution: Label installed.
Documentation › Certificates/Documents › Cargo Ship Safety Radio Certificate
Issued 10 April 2017
Resolved
Renew Expired Safety Radio Certificate.
Action required: 705 - Other - as specified
Due 24 April 2017
Resolved 17 April 2017
Resolution: Showed proof of renewed certificate.
Operations/Management › Equipment Service/Testing › EPIRB
Issued 18 April 2016
Resolved
EPIRB hydrostatic release inoperational. Replace hydrostatic release.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 2 May 2016
Resolved 20 April 2016
Resolution: Replaced hydrostatic release.
Fire Fighting › Ventilation Systems › Smoke Extraction System
Issued 18 April 2016
Resolved
Grease trap is missing on exhaust-hood. Provide grease trap for exhaust hood.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 2 May 2016
Resolved 20 April 2016
Resolution: Installed missing piece.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 18 April 2016
Resolved
Aft Nav Light is inoperable. Repair or replace Nav Light.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 2 May 2016
Resolved 18 April 2016
Resolution: Replaced light bulb.
Fire Fighting › Means of Escape › Escape Route Signs
Issued 18 April 2016
Resolved
Engine room escape hatch is not labeled. Label escape hatch.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 2 May 2016
Resolved 18 April 2016
Resolution: Relabeled escape hatch.