ALGOMA GUARDIAN

ALGOMA GUARDIAN is a 1987 freight ship. The Coast Guard has recorded 22 inspections since 2017, most recently in June 2026, along with 12 deficiencies.

Records from 2017 to 2026. Most recent: inspection, 25 June 2026.

Built
1987
Last inspected
25 June 2026
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 2016.

Inspection record

Last inspected 25 June 2026
…with no type recorded2
Operational controls None recorded without a removal date
Years with a record 9 calendar years (2017–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

8505850
CFK9698
280837
Flag
CANADA
Maury page id
psix-280837

Documentation record

Tonnage as PSIX records it23306 - Convention (Subpart B), Gross Ton
11667 - Convention (Subpart B), Net Ton
37911 - Dead Weight, Ton
45707 - Displacement, Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspected as a tow unit · 4

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

RT. HON. PAUL J. MARTIN Freight Ship · MISLE 226305 · 7 October 2019 · activity 6837229JARRETT M. Towing Vessel · MISLE 1140137 · 7 October 2019 · activity 6837229OCEAN ECHO II Towing Vessel · MISLE 1596290 · 7 October 2019 · activity 6837229OCEAN COMEAU Towing Vessel · MISLE 1596292 · 7 October 2019 · activity 6837229

Inspection history · 22

25 June 2026 Deficiency Check
Physical examination · Marine Safety Unit Duluth · USCG Great Lakes District (CGD-GL) · Activity 8413676
16 May 2026 PSC B · Canadian Vsl Safety Exam (D9 only)
Physical examination · Marine Safety Unit Duluth · USCG Great Lakes District (CGD-GL) · Activity 8371676
22 December 2025 In-Service Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 8286820
19 August 2025 Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 8213636
14 August 2025 PSC B · Canadian Vsl Safety Exam (D9 only)
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 8207560
17 April 2025 Canadian Vsl Safety Exam (D9 only) · PSC B
Physical examination · Marine Safety Unit Duluth · USCG Great Lakes District (CGD-GL) · Activity 8111796
21 September 2024 Deficiency Check
Physical examination · Marine Safety Unit Duluth · USCG Great Lakes District (CGD-GL) · Activity 8008076
28 August 2024 In-Service Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7990924
28 August 2024 Type not recorded
No type recorded · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 8009207
16 August 2024 Deficiency Check
Physical examination · Marine Safety Unit Duluth · USCG Great Lakes District (CGD-GL) · Activity 7982740
4 December 2023 PSC B · Canadian Vsl Safety Exam (D9 only)
Physical examination · Marine Safety Unit Duluth · USCG Great Lakes District (CGD-GL) · Activity 7831927
9 May 2023 Administrative Inspection
Administrative · Marine Safety Unit Duluth · USCG Great Lakes District (CGD-GL) · Activity 7684769
6 December 2022 Administrative Inspection
Administrative · Marine Safety Unit Duluth · USCG Great Lakes District (CGD-GL) · Activity 7605496
29 September 2022 Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Unit Duluth · USCG Great Lakes District (CGD-GL) · Activity 7568686
1 September 2022 In-Service Inspection · Deficiency Check
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7549224
31 August 2022 PSC B
Physical examination · Marine Safety Unit Duluth · USCG Great Lakes District (CGD-GL) · Activity 7546153
8 June 2021 Administrative Inspection
Administrative · Marine Safety Unit Duluth · USCG Great Lakes District (CGD-GL) · Activity 7219876
7 October 2019 Type not recorded
No type recorded · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 6837229
21 May 2019 Canadian Vsl Safety Exam (D9 only) · ISPS II Exam · Ballast Water Examination
Physical examination · Marine Safety Unit Duluth · USCG Great Lakes District (CGD-GL) · Activity 6687636
26 March 2019 Administrative Inspection
Administrative · Marine Safety Unit Duluth · USCG Great Lakes District (CGD-GL) · Activity 6649225
21 May 2018 Canadian Vsl Safety Exam (D9 only)
Physical examination · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 6417618
12 April 2017 Canadian Vsl Safety Exam (D9 only)
Physical examination · Marine Safety Unit Duluth · USCG Great Lakes District (CGD-GL) · Activity 6123213

Deficiency record · 12

01 - Certificates & Documentation › 013 - Documents › Fire control plan - all
Issued 16 May 2026 Resolved
All self-propelled vessels shall have the following plans. General arrangement plans showing...means of access to different compartments. Found self-closing door between fantail and engine room not listed on the fire control plan. 46 CFR 97.36-1(a) Action Taken: 50(a)(c)
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 June 2026
Resolved 25 June 2026
Resolution: Ship management provided updated FCP and survey results from Class Surveyor
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 14 August 2025 Resolved
The general construction of the vessel shall be such as to minimize fire hazards insofar as is reasonable and practicable. Lube oile leaks found throughout the purifier room. 46 CFR 92.05-1, 17c.
Action required: 17 - Rectify deficiencies prior to departure
Due 14 August 2025
Resolved 14 August 2025
Resolution: Vessel crew sufficiently cleaned oil in purifier room - source of leaks could not be located.
09 - Working and Living Conditions › 092 - Working Conditions › Protection machines/parts
Issued 14 August 2025 Resolved
Suitable hand covers, guards, or rails shall be installed in way of all exposed and dangerous places such as gears, machinery, etc. SSDG #3 was missing a cover, exposing crew to rotating machinery. 46 CFR 92.25-15, 10c.
Action required: 10 - Deficiency Rectified
Resolved 14 August 2025
Resolution: Crew fabricated a cover, removing danger of being caught in rotating machinery.
04 - Emergency Systems › N/A - No Subsystem › Emergency source of power - Emergency generator
Issued 14 August 2025 Resolved
An inspection either general or partial depending upon the circumstances shall be made whenever any important repairs or alterations are undertaken. Unapproved alteration made to the emergency generator. Require class to verify emergency generator installation and operation. 46 CFR 91.45-5, 16ac.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 August 2025
Resolved 19 August 2025
Resolution: Recieved Class document and email confirming/verifing installation and operation.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 17 April 2025 Resolved
The General Construction of the vessel shall be such as to minimize fire hazards insofar as is reasonable and practicable. Excessive diesel pooled underneath valve #8 and excessive oil on and around piping and valve at heavy fuel oil transfer area. 46 CFR 92.05-1 17ac
Action required: 17 - Rectify deficiencies prior to departure
Due 17 April 2025
Resolved 17 April 2025
Resolution: Pooled Diesel removed in the presence of a Port State Control Examiner
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 17 April 2025 Resolved
The General construction of the vessel shall be such as to minimize fire hazards insofar as is reasonable and practicable. Main engine crankcase has excessive oil on and around it, creating a potential fire hazard. 46 CFR 92.05-1 40ac
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 26 April 2025
Resolution: Main Engine was completely degreased, and all oil clean up around the main engine area.
09 - Working and Living Conditions › 091 - Living Conditions › Pipes, wires (insulation)
Issued 17 April 2025 Resolved
Pipe laggings shall be of approved incombustible materials. Main engine leak tank #1 oil supply and filtering piping AND piping near valve #65 in fuel purifying room, missing lagging. 46 CFR 92.07-10 40ac
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 26 April 2025
Resolution: New lagging installed at both locations with deficiencies.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Ventilators, air pipes, casings
Issued 17 April 2025 Resolved
All enclosed spaces within the vessel shall be properly vented or ventilated. Ventilation trunk to steering gear space severely wasted/rusted causing an estimated 5 inch gash, exposing the space to the main deck and weather elements. 46 CFR 92.15-15 40ac
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 26 April 2025
Resolution: Allied Marine and Industrial attended the vessel in Hamilton @ AM Dofasco and removed and replaced a small, wasted section of the exhaust ventilation tubing from the Steering Gear. Ventilation Duct is now confirmed water/weather tight
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 28 August 2024 Resolved
01-13101 A survey, either general or partial, according to the circumstances, shall be made every time an accident occurs or a defect is discovered which affects the safety of the vessel or the efficacy or completeness of its lifesaving appliances, fire-fighting or other equipment, or whenever any important repairs or renewals are made. The survey shall be such as to insure that the necessary repairs or renewals have been effectively made, that the material and the workmanship of such repairs or renewals are in all respects satisfactory, and that the vessel complies in all respects with the regulations in this subchapter. The main engine suffered a loss when a fuel pump pressure sensor failed. A survey must be conducted prior to departing Superior, WI.46CFR91.30-1
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 28 August 2024
Resolved 21 September 2024
Resolution: Vessel flushed oil filter elements and manually cycled solenoid valve to correct oil pressure issue. Class confirmed vessel engine operates satisfactorily.
09 - Working and Living Conditions › 092 - Working Conditions › Cleanliness of engine room
Issued 4 December 2023 Resolved
The general construction of the vessel shall be such as to minimize fire hazards insofar as is reasonable and practicable. Main Diesel Engine surface and lagging has excessive dried oil creating a potential fire hazard. inspectors noted there is no active leak.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 January 2024
Resolved 16 August 2024
Resolution: Engine cleaned and lagging removed
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboat inventory
Issued 31 August 2022 Resolved
The first aid kit in a lifeboat and in a rescue boat must be approved under approval series 160.041. The first aid kit in the rescue boat is expired. Third officer is ordering replacement.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 September 2022
Resolved 29 September 2022
Resolution: Rectified via class attendance report and picture evidence provided by vessel deck superintendent.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 31 August 2022 Resolved
The steering gear compartment must include handrails and either graitings or other non slip surfaces to ensure a safe working environment if hydraulic fluid leaks. Steering gear room has no grating or non slip surfaces, if hydraulic oil leaks it goes onto the metal deck.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 September 2022
Resolved 29 September 2022
Resolution: Rectified via class attendance report and picture evidence submitted by vessel deck superintendent.