MAURY USCG vessel records Sign in
← All vessels

ORION

ORION is a 1979 tank ship. The Coast Guard has recorded 64 inspections since 1987, most recently in November 2003, along with 90 deficiencies and 3 operational controls.

Records from 1987 to 2003. Most recent: inspection, 1 November 2003.

Built
1979
Last inspected
1 November 2003
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

7903366 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
280852
Flag
PANAMA
—
Maury page id
psix-280852

Inspections, by type

…with no type recorded44
Years with a record 17 calendar years (1987–2003)
The 64 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 23 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it3167 - Regulatory (Subpart C or D), Gross Ton
1748 - Regulatory (Subpart C or D), Net Ton
5211 - Dead Weight, Ton
7203 - Displacement, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 64

1 November 2003 Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1940020
9 September 2003 Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1900886
28 July 2003 Annual Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1859788
11 September 2002 Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1674369
19 April 2002 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1606829
3 April 2002 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1605016
17 September 2001 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 293658
17 September 2001 Tank Vessel Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1073339
6 August 2001 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 292606
10 July 2001 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 640798
29 June 2001 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 291295
3 October 2000 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 282755
3 October 2000 Tank Vessel Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1054849
16 November 1999 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 435573
13 November 1999 PSC A
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 434647
13 November 1999 Tank Vessel Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 815073
25 January 1999 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 424737
18 December 1998 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 423673
9 November 1998 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 422257
9 November 1998 Tank Vessel Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 804949
24 September 1998 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 420727
28 August 1998 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 419704
17 March 1998 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 209302
17 March 1998 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 767752
16 March 1998 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 413624
14 February 1998 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 209769
14 February 1998 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 758077
11 February 1998 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 412590
12 January 1998 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 411606
12 December 1997 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 410767
4 November 1997 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 409455
4 November 1997 Tank Vessel Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1121628
20 August 1996 Type not recorded
No type recorded · MSO GUAM · USCG Oceania District (CGD-O) · Activity 394507
20 August 1996 Type not recorded
No type recorded · MSO GUAM · USCG Oceania District (CGD-O) · Activity 683650
9 April 1996 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 539740
4 August 1995 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 381194
4 August 1995 Tank Vessel Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1192610
22 February 1995 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 375366
8 July 1994 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 368484
8 July 1994 Tank Vessel Examination · MARPOL Annex V Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1356719
27 August 1993 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 456115
10 June 1993 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 358586
10 June 1993 MARPOL Annex V Examination · Certificate of Compliance
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1151235
7 April 1993 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 683649
5 April 1993 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 493003
4 April 1993 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 155670
30 October 1992 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 354157
1 June 1992 Certificate of Compliance
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1255290
1 April 1992 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 511745
2 March 1992 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 962140
3 July 1991 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 344711
3 July 1991 Certificate of Compliance
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 937804
4 January 1991 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 491869
23 June 1990 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 337812
23 June 1990 Certificate of Compliance
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 926754
23 June 1990 Certificate of Compliance
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 931924
20 December 1989 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 334390
20 December 1989 Certificate of Compliance
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1216143
24 May 1989 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 455528
30 December 1988 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 327643
28 November 1988 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 326984
28 November 1988 Certificate of Compliance
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1205749
28 May 1987 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 316383
28 May 1987 Certificate of Compliance
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1339061

Deficiency record · 90

Fire Fighting › Means of Escape
Issued 31 July 2003 Resolved
Install extraction unit in pumproom in accordance with 46 CFR 35.30-2(c)(2). LEGACY COMPONENT DESC: Landings
Condition: Improper/Lack of Maintenance
Action required: 15 - Rectify deficiencies by next port
Due 31 July 2003
Resolved 17 September 2003
Resolution: installed unit
Fire Fighting › Portable CO2 Fire Extinguisher
Issued 31 July 2003 Resolved
Have CO2 discharge bell function in accordance with SOLAS Ch II-2 Reg. 5. LEGACY COMPONENT DESC: Discharge Hose/Tube
Condition: Improper/Lack of Maintenance
Action required: 15 - Rectify deficiencies by next port
Due 31 July 2003
Resolved 17 September 2003
Resolution: bell is functional
Electrical › Lighting (service)
Issued 31 July 2003 Resolved
Replace pump room light bulb in accordance with 46 CFR 32.60-20 prior to next U.S. port. LEGACY COMPONENT DESC: Lighting Fixture
Condition: Improper Installation
Action required: 15 - Rectify deficiencies by next port
Due 31 July 2003
Resolved 17 September 2003
Resolution: lights replaced
Engineering › Fuel Oil Service System
Issued 31 July 2003 Resolved
Bolt/secure all high pressure fuel oil line flexible couplings on all six (6) cylinders in accordance with SOLAS Ch II-1 Reg 26 to the satisfaction of Class. LEGACY COMPONENT DESC: Flange
Condition: Improper/Lack of Maintenance
Action required: 15 - Rectify deficiencies by next port
Due 31 July 2003
Resolved 17 September 2003
Resolution: high pressure fuel lines were secured
Accommodation/Occupational Safety › Occupational Safety
Issued 31 July 2003 Resolved
Install machinery guard on emergency fire pump hand crank in accordance with SOLAS Ch. II-1 Reg. 26.1. LEGACY COMPONENT DESC: Guards for Exposed Hazards
Condition: Improper/Lack of Maintenance
Action required: 15 - Rectify deficiencies by next port
Due 31 July 2003
Resolved 17 September 2003
Resolution: guard was inplace
Fire Fighting › Portable CO2 Fire Extinguisher
Issued 31 July 2003 Resolved
Install fire extinguisher brackets in boatswain storage room in accordance with SOLAS Ch II-2 Reg 6 to the satisfaction of Class. LEGACY COMPONENT DESC: Mounting Bracket
Condition: Improper/Lack of Maintenance
Action required: 15 - Rectify deficiencies by next port
Due 31 July 2003
Resolved 17 September 2003
Resolution: brackets were replaced
Accommodation/Occupational Safety › Potable Water System
Issued 31 July 2003 Resolved
Install hot running water in the galley in accordance with ILO 147 to the satisfaction of Class. LEGACY COMPONENT DESC: Hot Water
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 31 July 2003
Resolved 1 November 2003
Resolution: Received Class report stating that hot water has been installed in galley.
Electrical › Electrical Distribution System (service)
Issued 31 July 2003 Resolved
Remove boxes in front of control panel for anchor windlass control panel in accordance with SOLAS Ch II-1 Reg. 40.1.1. LEGACY COMPONENT DESC: Panelboard
Condition: Improper/Lack of Maintenance
Action required: 15 - Rectify deficiencies by next port
Due 31 July 2003
Resolved 17 September 2003
Resolution: boxes were removed from cite
Deck/Cargo › Ballast
Issued 31 July 2003 Resolved
Repair leaking flange from ballast water packing in pump room in accordance with SOLAS I/II to the satisfaction of Class. LEGACY COMPONENT DESC: Piping
Condition: Improper/Lack of Maintenance
Action required: 15 - Rectify deficiencies by next port
Due 31 July 2003
Resolved 17 September 2003
Resolution: leak was fixed
Deck/Cargo › Cargo Transfer/Lightering (liquid)
Issued 31 July 2003 Resolved
Repair leaking flange from ballast water packing in pump room in accordance with SOLAS Ch I/II Reg 1. to the satisfaction of Class. LEGACY COMPONENT DESC: Pumproom
Condition: Improper/Lack of Maintenance
Action required: 15 - Rectify deficiencies by next port
Due 31 July 2003
Resolved 17 September 2003
Resolution: leak was fixed
Accommodation/Occupational Safety › Occupational Safety
Issued 31 July 2003 Resolved
Request Classification Society inspect starboard side hand rail adjacent to container to ensure compliance with ILLC Regulation 19. LEGACY COMPONENT DESC: Deck Rail
Condition: Improper Installation
Action required: 15 - Rectify deficiencies by next port
Due 31 July 2003
Resolved 17 September 2003
Resolution: replaced hand rail
Accommodation/Occupational Safety › Washroom/Toilet
Issued 31 July 2003 Resolved
Provide a sink with running water in stateroom of 3rd mate in accordance with ILO 147. LEGACY COMPONENT DESC: Hot and Cold Running Water
Condition: Improper Installation
Action required: 15 - Rectify deficiencies by next port
Due 31 July 2003
Resolved 17 September 2003
Resolution: provided state room with sink
Operations/Management › Vessel Safety Management
Issued 31 July 2003 Resolved
Conduct an external audit of the vessels Safety Management System Code (SMS) by the Administration or an organization recognized by the Administration IAW SOLAS 74/76 (amended) Ch IX Reg. 3. LEGACY COMPONENT DESC: External Certification/Verification/Control
Condition: Unknown
Action required: 15 - Rectify deficiencies by next port
Due 31 July 2003
Resolved 17 September 2003
Resolution: audit was intiated and master has a better knowledge of ISM
Operations/Management › Navigation Safety
Issued 28 July 2003 Resolved
Provide International Rules of the Road in accordance with SOLAS Ch V Reg. 20 prior to next U.S. port. LEGACY COMPONENT DESC: Carriage of Charts and Publications
Condition: Unknown
Action required: 15 - Rectify deficiencies by next port
Due 31 July 2003
Resolved 17 September 2003
Resolution: Bought new books
Lifesaving › Emergency Outfit
Issued 28 July 2003 Resolved
Install EEBA in pumproom in accordance with 46 CFR 35.30-2(c)(1). LEGACY COMPONENT DESC: Breathing Apparatus
Condition: Improper/Lack of Maintenance
Action required: 15 - Rectify deficiencies by next port
Due 31 July 2003
Resolved 17 September 2003
Resolution: installed extraction unit in pumproom
Personnel › Certificates/Documents/Licenses › License, Second Mate
Issued 28 July 2003 Resolved
Provide proof of Second Mate qualifications and licensing.
Condition: Placed in Improper Service
Action required: 17 - Rectify deficiencies prior to departure
Resolved 1 August 2003
Resolution: Admnistration provided position can be filled to meet safe manning document requirements.
Documentation
Issued 29 June 2001 Resolved
Provide receipts for disposal of plastic IAW MARPOL ANNEX V 9/4.2.
Condition: Unknown
Due 6 August 2001
Resolved 6 August 2001
Documentation
Issued 29 June 2001 Resolved
Provide record of plastic disposal in garbage logbook IAW MARPOL ANNEX V, 9/4.1.
Condition: Unknown
Due 6 August 2001
Resolved 6 August 2001
Unknown
Issued 29 June 2001 Resolved
Provide proof of proper plastic disposal for the voyage lasting from 18MAY01-27JUN 2001.
Condition: Unknown
Due 29 June 2001
Resolved 6 July 2001
Unknown
Issued 13 November 1999 Resolved
Crop and renew wasted sewage pipe IAW SOLAS 60, Ch.1, Reg.11.
Condition: Unknown
Due 19 November 1999
Resolved 19 November 1999
Unknown
Issued 13 November 1999 Resolved
Crop and renew as original shower gooseneck IAW SOLAS 60, Ch.1, Reg.11.
Condition: Unknown
Due 17 November 1999
Resolved 17 November 1999
Unknown
Issued 13 November 1999 Resolved
Crop and renew wasted overboard deck drain located in the steering gear room IAW ICCL, 1966, Reg22.
Condition: Unknown
Due 17 November 1999
Resolved 17 November 1999
Navigation
Issued 13 November 1999 Resolved
Crop and renew IAW SOLAS 60, Ch.1, Reg.11.
Condition: Unknown
Due 18 November 1999
Resolved 18 November 1999
Navigation
Issued 13 November 1999 Resolved
Provide proof of shore based maintenance contract IAW SOLAS 74 (Amended) Ch.IV, Reg.15.
Condition: Unknown
Due 17 November 1999
Resolved 17 November 1999
Engineering
Issued 13 November 1999 Resolved
Repair or replace cracked and wasted fittings on spare bunker hose IAW 33 CFR 154.500(d).
Condition: Unknown
Due 18 November 1999
Resolved 18 November 1999
Navigation
Issued 13 November 1999 Resolved
Repair or replace mast light (all round) as original prior to departing U.S. port IAW ICPCS, 72, Part A, Rule 32.
Condition: Unknown
Due 18 November 1999
Resolved 18 November 1999
Fire Fighting
Issued 13 November 1999 Resolved
Repair or replace door IAW SOLAS 60, Ch.1, Reg.11.
Condition: Unknown
Due 18 November 1999
Resolved 18 November 1999
Navigation
Issued 18 December 1998 Resolved
Install missing retainers on all steering components.
Condition: Unknown
Due 26 January 1999
Resolved 26 January 1999
Electrical
Issued 18 December 1998 Resolved
Remove temporary jumper wiring/cabling and permanently connect all batteries in battery room.
Condition: Unknown
Due 26 January 1999
Resolved 26 January 1999
Electrical
Issued 18 December 1998 Resolved
Remove temporary wiring and permanently wire steering room lathe and light.
Condition: Unknown
Due 26 January 1999
Resolved 26 January 1999
Construction/Loadline
Issued 9 November 1998 Resolved
Prove proper operation of ODM to CG inspector.
Condition: Unknown
Due 26 January 1999
Resolved 26 January 1999
Documentation
Issued 9 November 1998 Resolved
Provide flag state documentation for recognizing the licenses of non-flag state officers. Provide documentation of flag state recognition of officers licences for the master and chief mate.
Condition: Unknown
Due 18 December 1998
Resolved 18 December 1998
Construction/Loadline
Issued 9 November 1998 Resolved
Repair starboard exhaust vent for bow thruster to satisfaction of class.
Condition: Unknown
Due 18 December 1998
Resolved 18 December 1998
Documentation
Issued 24 September 1998 Resolved
Found safety equipment certificate supplement missing. Provide documentation before next U.S. port.
Condition: Unknown
Due 10 November 1998
Resolved 10 November 1998
Construction/Loadline
Issued 24 September 1998 Resolved
Found holes in forward bulkhead of cargo pump room shell. Repair to the satisfaction of NKK class society.
Condition: Unknown
Due 10 November 1998
Resolved 10 November 1998
Construction/Loadline
Issued 24 September 1998 Resolved
Found holes in main deck aft of galley bulkhead in and around windless area. Repair to the satisfaction of NKK class society.
Condition: Unknown
Due 10 November 1998
Resolved 10 November 1998
Documentation
Issued 24 September 1998 Resolved
Found officers licences not of flag of vessel. Provide documentation of flag state recognition of officers licences.
Condition: Unknown
Due 10 November 1998
Resolved 10 November 1998
Electrical
Issued 28 August 1998 Resolved
Provide various light covers throughout ship IAW SOLAS 60 Reg 27(a).
Condition: Unknown
Due 25 September 1998
Resolved 25 September 1998
Fire Fighting
Issued 28 August 1998 Resolved
In lieu of wooden plugs in #3 starboard and #3 port cargo tank steam lines make permanent repairs to satisfaction of class.
Condition: Unknown
Due 25 September 1998
Resolved 25 September 1998
Fire Fighting
Issued 28 August 1998 Resolved
Repair soft patch on CO2 line for #3 cargo tank, IAW ICLL Reg 22.
Condition: Unknown
Due 25 September 1998
Resolved 25 September 1998
Documentation
Issued 28 August 1998 Resolved
Provide flag state documentation for recognizing the licences of non-flag state officers, IAW STCW I/10.
Condition: Unknown
Due 25 September 1998
Resolved 25 September 1998
Documentation
Issued 16 March 1998 Resolved
Provide approval letter from U.S. Coast Guard for Vessel Response Plan for M/V ORION IAW 33 CFR 155.1030(i)(1) prior to departure.
Condition: Unknown
Due 17 March 1998
Resolved 19 March 1998
Construction/Loadline
Issued 16 March 1998 Resolved
Remove excess oil in engineroom bilge area IAW 33 CFR 155.770 prior to departure/hotwork.
Condition: Unknown
Due 17 March 1998
Resolved 19 March 1998
Unknown
Issued 16 March 1998 Resolved
Manhole cover for slop tank aft was missing with contents exposed.
Condition: Unknown
Due 19 March 1998
Resolved 19 March 1998
Engineering
Issued 16 March 1998 Resolved
Repair shaft S/W cooling line L/L aft prior to departing IAW ICLL Reg 22.
Condition: Unknown
Due 19 March 1998
Resolved 19 March 1998
Construction/Loadline
Issued 16 March 1998 Resolved
Repair to satisfaction of class severe corrosion portside hull plating lower level engineroom at frames 23-25. UT readings revealed wastage in excess of 50% IAW ICLL Reg 22.
Condition: Unknown
Due 19 March 1998
Resolved 23 March 1998
Engineering
Issued 16 March 1998 Resolved
STBD side MDE L/O heat exchanger S/W line severely corroded.
Condition: Unknown
Due 19 March 1998
Resolved 19 March 1998
Engineering
Issued 16 March 1998 Resolved
Repair soft patch on auxiliary condenser in engineroom IAW ICLL Reg 22.
Condition: Unknown
Due 8 September 1998
Resolved 8 September 1998
Accommodation/Occupational Safety
Issued 16 March 1998 Resolved
Repair soft patch on S/W supply line for A.C. L/L engine room IAW ICLL Reg 22.
Condition: Unknown
Due 8 September 1998
Resolved 8 September 1998
Accommodation/Occupational Safety
Issued 16 March 1998 Resolved
Repair soft patches on S/W supply line to MSD IAW ICLL Reg 22.
Condition: Unknown
Due 8 September 1998
Resolved 8 September 1998
Accommodation/Occupational Safety
Issued 16 March 1998 Resolved
Repair soft patches on sewage drain located on skin of ship IAW ICLL Reg 22.
Condition: Unknown
Due 8 September 1998
Resolved 8 September 1998
Engineering
Issued 16 March 1998 Resolved
Repair F/W cooling line starboard side aft L/L engine room IAW ICLL Reg 22.
Condition: Unknown
Due 8 September 1998
Resolved 8 September 1998
Construction/Loadline
Issued 16 March 1998 Resolved
Replace/repair missing pipe from oil filter system so it will not drain directly into bilge IAW 33 CFR 155.770.
Condition: Unknown
Due 8 September 1998
Resolved 8 September 1998
Unknown
Issued 16 March 1998 Resolved
Obtain class approved survey report attesting to the satisfactory conditionof all sea water piping in the engine room.
Condition: Unknown
Due 8 September 1998
Resolved 8 September 1998
Documentation
Issued 16 March 1998 Resolved
Provide Certificate of Competency from Singapore Govt for [name withheld] and3rd Engineer prior to next U.S. port.
Condition: Unknown
Due 8 September 1998
Resolved 8 September 1998
Construction/Loadline
Issued 16 March 1998 Resolved
Effect permanent repairs to wasted side shell plating at FR 23-25 port sideengine room during next scheduled drydock to the satisfaction of class prior to next U.S. port entry.
Condition: Unknown
Due 8 September 1998
Resolved 8 September 1998
Documentation
Issued 11 February 1998 Resolved
Provide flag state documentation for recognizing the licenses of non-flag state officers, IAW STCW I/10.
Condition: Unknown
Due 26 March 1998
Resolved 26 March 1998
Electrical
Issued 11 February 1998 Resolved
Provide various light covers throughout ship, IAW SOLAS 60 REG II/27(a).
Condition: Unknown
Due 8 September 1998
Resolved 8 September 1998
Deck/Cargo
Issued 12 January 1998 Resolved
Conduct hrydrostatic tests IAW 33CFR156.170 for cargo and bunker piping system.
Condition: Unknown
Due 14 January 1998
Resolved 14 January 1998
Electrical
Issued 12 January 1998 Resolved
Remove non-explosion proof switch from inside door of cargo pump room.
Condition: Unknown
Due 15 January 1998
Resolved 15 January 1998
Engineering
Issued 12 January 1998 Resolved
Effect permanent repairs to the saltwater cooling pipe for the #2 ships service diesel generator.
Condition: Unknown
Due 13 March 1998
Resolved 18 March 1998
Accommodation/Occupational Safety
Issued 12 January 1998 Resolved
Repair broken handrail in engine room adjacent to engine control room IAW ILLC 66 Annex 1/25.
Condition: Unknown
Due 11 February 1998
Resolved 11 February 1998
Lifesaving
Issued 12 December 1997 Resolved
Found both blocks on the port lifeboat falls to be unsafe. Vessel cannot depart Hawaii until repaired to satisfaction of class.
Condition: Unknown
Due 17 December 1997
Resolved 18 December 1997
Engineering
Issued 12 December 1997 Resolved
Found soft patch on jacket water supply line, main diesel engine lower level starboard aft. Repair to satisfaction of class prior to next U.S. port.
Condition: Unknown
Due 13 March 1998
Resolved 18 March 1998
Accommodation/Occupational Safety
Issued 12 December 1997 Resolved
Found grates on catwalks and at each cargo manifold to be unsafe due to wastage. Repair prior to next U.S. port in accordance with ILLC 66 ANNEX I/25.
Condition: Unknown
Due 13 March 1998
Resolved 18 March 1998
Electrical
Issued 12 December 1997 Resolved
Found explosion proof light at top of pump room with no ground wire. Replace prior to next U.S. port in accordance with SOLAS 60 REG II/26.
Condition: Unknown
Due 12 February 1998
Resolved 15 January 1998
Documentation
Issued 12 December 1997 Resolved
Oil transfer procedures not in common language of crew. Rewrite in_x001C_ working language common to crew in accordance with 33CFR155.740 prior to next U.S. port.
Condition: Unknown
Due 12 January 1998
Resolved 13 January 1998
Accommodation/Occupational Safety
Issued 12 December 1997 Resolved
Found both ladders leading from fantail to boat deck to have wasted handrails. Repair prior to next U.S. port in accordance with ILLC 66 ANNEXI/25.
Condition: Unknown
Due 13 January 1998
Resolved 13 January 1998
Accommodation/Occupational Safety
Issued 12 December 1997 Resolved
Found hand rail on port side ladder main deck leading to tank top aft wasted. Repair prior to next U.S. port in accordance with ILLC ANNEX I/25.
Condition: Unknown
Due 13 January 1998
Resolved 13 January 1998
Accommodation/Occupational Safety
Issued 12 December 1997 Resolved
Found landing for starboard accomodation ladder to be wasted. Repair priorto next U.S. port in accordance with ILLC 66 ANNEX 1/25.
Condition: Unknown
Due 12 January 1998
Resolved 13 January 1998
Engineering
Issued 12 December 1997 Resolved
Found excessive lube oil leaks coming from lifters on main diesel engine. Repair to satisfaction of class prior to next U.S. port in accordance with 33CFR155.770.
Condition: Unknown
Due 13 January 1998
Resolved 13 January 1998
Electrical
Issued 12 December 1997 Resolved
Found light cover missing in hospital space. Replace prior to next U.S. port in accordance with SOLAS 60 REG II/26.
Condition: Unknown
Due 13 January 1998
Resolved 13 January 1998
Accommodation/Occupational Safety
Issued 12 December 1997 Resolved
Found bottom stair tread main deck port side aft is wasted. Replace prior to next U. S. port in accordance ILLC 66 ANNEX I/25.
Condition: Unknown
Due 13 January 1998
Resolved 13 January 1998
Accommodation/Occupational Safety
Issued 12 December 1997 Resolved
Found all safety chains on lifelines to be unsafe due to corrosion. Replace prior to next U.S. port in accordance with ILLC 66 ANNEX I/25.
Condition: Unknown
Due 13 January 1998
Resolved 13 January 1998
Accommodation/Occupational Safety
Issued 12 December 1997 Resolved
Found securing devices for removable lifeline sections are missing/broken. Replace prior to next U.S. port in accordance with ILLC 66 ANNEX I/25._x001C_
Condition: Unknown
Due 13 January 1998
Resolved 13 January 1998
Construction/Loadline
Issued 12 December 1997 Resolved
Found severe corrosion under aft winch control station deck completely wasted. Repair to satisfaction of class prior to next U.S. port in accordance with ILLC 66 ANNEX I/1.
Condition: Unknown
Due 13 January 1998
Resolved 13 January 1998
Construction/Loadline
Issued 12 December 1997 Resolved
Found numerous holes in deck space containment starboard side 01 deck._x001C_ Repair prior to next U.S. port in accordance with 33CFR155.310(a).
Condition: Unknown
Due 13 January 1998
Resolved 13 January 1998
Documentation
Issued 4 November 1997 Resolved
UPDATE VESSEL RESPONSE PLAN TO SHOW CURRENT LISTING OF OIL SPILL REMOVAL ORGANIZATIONS. CLEAN ISLAND COUNCIL SHOULD BE DELETED FROM THIS LIST. OILSPILL REMOVAL COVERAGE FOR HONOLULU AREA IS BEING PROVIDED THROUGH PACIFIC ENVIRONMENTAL CORP., AND NATIONAL RESPONSE CORP. SUB CONTRACTORS.
Condition: Unknown
Due 17 December 1997
Resolved 17 December 1997
Construction/Loadline
Issued 4 November 1997 Resolved
RENEW WASTED #1 STBD BALLAST TANK VENT COVER.
Condition: Unknown
Due 17 December 1997
Resolved 17 December 1997
Deck/Cargo
Issued 20 August 1996 Resolved
Observed that the transfer hoses located on the open deck of the T/V Kopex were not properly marked with the Maximum Allowable Working Pressure (MAWP)in accordance with 33 CFR 154.500(f)(1)._x001C_ _x001C_
Condition: Unknown
Due 5 November 1997
Resolved 5 November 1997
Deck/Cargo
Issued 20 August 1996 Resolved
Observed that the cargo fuel transfer hoses located on the open deck of T/VKopex were not marked with the required "oil service" in accordance with 33CFR 154.500(e)(1)._x001C_ _x001C_
Condition: Unknown
Due 5 November 1997
Resolved 5 November 1997
Deck/Cargo
Issued 20 August 1996 Resolved
Observed that the transfer hoses had not been tested within the past year as required by 33 CFR 156.170(f)(2). This cite specifies that the hose must be tested "annually or as part of the biennial and mid-period inspections for vessels."_x001C_
Condition: Unknown
Due 5 November 1997
Resolved 5 November 1997
Unknown
Issued 20 August 1996 Resolved
Observed that the T/V Kopex was utilizing non-intrinisically-safe radios for communication while on board the vessel. However, the master stated that these radios were only used inside the superstructure of the vessel._x001C_ _x001C_
Condition: Unknown
Due 20 August 1996
Resolved 20 August 1996
Navigation
Issued 20 August 1996 Resolved
Observed that the navigation chart, NOAA #81054, was a 1980 edition and hadnot been updated by Notice to Mariner Bulletins as required by the above cite._x001C_
Condition: Unknown
Due 24 August 1996
Resolved 22 August 1996
Fire Fighting
Issued 4 August 1995 Resolved
FAILURE TO MAINTAIN FIRE MAIN SYSTEM RESULTING IN WASTED SECTIONS OF PIPE AND INADEQUATE FIREMAIN PRESSURE IN VIOLATION OF SOLAS CHAPTER II-2, PART A, REGULATION 4 AND SOLAS CHAPTER I, PART B, REGULATION 11.
Condition: Unknown
Due 7 August 1995
Resolved 10 August 1995
Lifesaving
Issued 4 August 1995 Resolved
REPAIR/REPLACE AND PROPERLY CLEAN FLAME SCREENS ATTACHED TO VENT SYSTEMS SERVING ALL TANKS CONTAINING FLAMMABLOE LIQUIDS IN ACCORDANCE WITH MARPOL CHAPTER I.
Condition: Unknown
Due 7 August 1995
Resolved 10 August 1995
Lifesaving
Issued 4 August 1995 Resolved
MEET ELECTRICAL COMPLIANCE FOR AREAS WHERE FLAMMABLE VAPORS ARE PRESENT (INCARGO PUMPROOM) IN ACCORDANCE WITH SOLAS CHAPTER II-1, REGULATION 45.
Condition: Unknown
Due 7 August 1995
Resolved 10 August 1995
Fire Fighting
Issued 2 March 1992 Resolved
REPAIR MINOR PINHOLE LEAK IN FIRE MAIN PRIOR TO NEXT U.S. PORT.
Condition: Unknown
Due 2 March 1992
Resolved 2 March 1992
Navigation
Issued 28 November 1988 Resolved
VESSEL 1600 OR MORE GROSS TONS MUST HAVE A CURRENTLY CORRECT U. S. COAST PILOT OR A FOREIGN EQUILAVENT FOR THE AREA TRANSITING. VESSEL HAD A 1987 U. S. COAST PILOT #7 WITH CORRECTIONS UP TO 22/87.
Condition: Unknown
Due 28 November 1988
Resolved 28 November 1988
Deck/Cargo
Issued 28 November 1988 Resolved
PROVIDE CONTAINMENT FOR OR ISOLATE FORWARD CARGO BRANCH LINE THAT IS NOT PROTECTED BY FIXED CONTAINMENT.
Condition: Unknown
Due 28 November 1988
Resolved 28 November 1988

Ownership record