Records from 1987 to 2005. Most recent: inspection, 15 August 2005.
Documentation record
Registered dimensions (L × B × D)64.0 ft × 20.0 ft × 4.0 ft
Registered tonnagegross 43 / net 43
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderHARDIN WELDING COMPANY · LACON, IL, UNITED STATES · built 1987
Hull materialSteel
PropulsionNone
Hull shapeBox
Hull configurationMonohull
Hailing portST LOUIS, MO
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 13 September 2025 · expires 31 October 2026
Service, as the file records itPassenger (Inspected)
Hull formunknown (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it43 - Simplified, Gross Ton
43 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 27
15 August 2005
Administrative Inspection
Administrative · MSD QUAD CITIES · USCG Heartland District (CGD-H) · Activity 2499607
25 May 2004
Re-Inspection
Physical examination · MSD QUAD CITIES · USCG Heartland District (CGD-H) · Activity 2065539
15 May 2003
Annual Inspection
Physical examination · MSD QUAD CITIES · USCG Heartland District (CGD-H) · Activity 1794256
14 May 2002
COI Inspection
Physical examination · MSD QUAD CITIES · USCG Heartland District (CGD-H) · Activity 1616796
3 April 2002
Hull Examination
Physical examination · MSD QUAD CITIES · USCG Heartland District (CGD-H) · Activity 1601412
2 July 2001
Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1449487
24 July 2000
Administrative
Administrative · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1440364
18 May 2000
Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1412165
22 May 1999
COI Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1447958
21 May 1998
Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1469841
22 May 1997
Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1433202
8 April 1997
Hull Examination
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1434541
4 June 1996
Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 879739
22 May 1996
COI Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1374611
24 May 1995
Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1183254
29 August 1994
Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 870290
5 August 1994
Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1405584
14 June 1993
Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 839488
26 May 1993
COI Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1407166
2 June 1992
Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1462302
9 April 1992
Hull Examination
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1447183
16 May 1991
Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1224962
10 May 1990
COI Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 926076
27 October 1989
Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 912452
26 May 1988
Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1202331
24 August 1987
Administrative
Administrative · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1034928
11 May 1987
Initial Construction-Excluding Oversight · Initial Certification · Plan Review "T" Boat · Hull Examination
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1027464
Engineering › Bilge Water Management System
Issued 25 May 2004
Resolved
Provide hand portable bilge pump prior to carrying passengers. LEGACY COMPONENT DESC: Pump
Condition: Unknown
Action required: 705 - Other - as specified
Due 25 June 2004
Resolved 27 May 2004
Resolution: Hand bilge pump provided.
Fire Fighting › Portable Dry Chemical Fire Extinguisher
Issued 14 May 2002
Resolved
Provide proof of proper service of fire extinguishers LEGACY COMPONENT DESC: Service
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 May 2002
Accommodation/Occupational Safety › Medical/First Aid
Issued 14 May 2002
Resolved
Ensure a first aid kit is on board vessel.
Action required: 705 - Other - as specified
Due 15 June 2002
Resolved 20 May 2002
Construction/Loadline › Hull
Issued 5 April 2002
Resolved
Repair washed out welds on seams as marked by Marine Inspector. LEGACY COMPONENT DESC: Bottom Plating
Action required: 705 - Other - as specified
Resolved 5 April 2002
Resolution: As witnessed by the Marine Inspector
Lifesaving
Issued 2 July 2001
Resolved
Post instructions for donning life jackets.
Condition: Unknown
Due 3 July 2001
Resolved 3 July 2001
Fire Fighting
Issued 18 May 2000
Resolved
Place pressure guage on fire pump as per 46 CFR 181.300 NLT 24 AUG 00
Condition: Unknown
Due 24 August 2000
Resolved 31 August 2000
Lifesaving
Issued 18 May 2000
Resolved
Place proper retro tape on life rings on bow and stern NLT 24 AUG 00
Condition: Unknown
Due 24 August 2000
Resolved 31 August 2000
Fire Fighting
Issued 22 May 1996
Resolved
REPLACE FIREHOSE WITH MARINE-TYPE FIRE HOSE PRIOR TO THE CARRIAGE OF PASSENGERS.
Condition: Unknown
Due 22 May 1996
Resolved 22 May 1996
Lifesaving
Issued 22 May 1996
Resolved
LABEL CHILD LIFEJACKET LOCKER WITH NUMBER OF JACKETS AVAILABLE.
Condition: Unknown
Due 22 May 1996
Resolved 22 May 1996
Fire Fighting
Issued 5 August 1994
Resolved
REPLACE MISSING HAND POWERED FIRE PUMP.
Condition: Unknown
Due 5 September 1994
Resolved 29 August 1994
Unknown
Issued 5 August 1994
Resolved
REPLACE MISSING NAME ON STERN. USE MINIMUM OF 4 INCH LETTERS.
Condition: Unknown
Due 5 September 1994
Resolved 29 August 1994
Construction/Loadline
Issued 26 May 1993
Resolved
IDENTIFY BILGE SUCTION VALVES BY LABELING THEM.
Condition: Unknown
Due 26 June 1993
Resolved 14 June 1993
Fire Fighting
Issued 11 May 1987
Resolved
PROVIDE B-I AND B-II FIRE EXTINGUISHER PRIOR TO EMBARKING PASSENGERS.
Condition: Unknown
Due 11 May 1987
Resolved 11 May 1987
Lifesaving
Issued 11 May 1987
Resolved
PROVIDE VISUAL DISTRESS SIGNALS IN ACCORDANCE WITH 46 CFR 180.35-5.
Condition: Unknown
Due 11 May 1987
Resolved 11 May 1987