Documentation record
Registered dimensions (L × B × D)64.9 ft × 25.6 ft × 6.2 ft
Registered tonnagegross 69 / net 55
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderEAST BAY BOAT WORKS INC · HARKERS ISLAND, NC, UNITED STATES · built 1987
Hull materialWood
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portDESTIN, FL
Endorsements, as the file codes themcw_un
DocumentationCase Pending · issued 30 June 2004
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it55 - Simplified, Net Ton
69 - Simplified, Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
The full record for this vessel
Behind this panel: 22 inspections, each with its date, unit and type; 7 deficiencies with the resolution recorded against each; operational controls, none recorded without a removal date; no tow-unit appearances recorded; no other recorded names; the documentation record: dimensions, tonnage, builder, hailing port and endorsements. Every line is a record the Coast
Guard wrote; the counts above are the same counts as in the summary, and they are free.
Professional is $39 a month or $299 a year,
or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks
every detail section on every vessel page, fleet watch tied to your account, and ownership records
on request. Already a subscriber? Sign in.
Maury does not score, rate or grade vessels, at any price.
Inspection history · 22
8 May 2026
Vessel Attendance · DAPI Audit · Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 8369120
19 May 2025
Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 8139157
5 May 2025
Deficiency Check · Annual Inspection · DAPI Audit · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 8121557
28 February 2025
Internal Structural Exam · Drydock Exam · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8086417
24 January 2025
Administrative Inspection
Administrative · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 8069310
24 January 2025
Administrative Inspection
Administrative · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 8070980
12 June 2024
Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7929933
19 April 2023
Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7670257
24 March 2023
Internal Structural Exam · Examination of Repairs · Drydock Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7656069
21 March 2022
Administrative Inspection · COI Inspection · DAPI Audit
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7403065
1 July 2021
Deficiency Check
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7241577
29 April 2021
Annual Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7185359
9 April 2021
Internal Structural Exam · Deficiency Check · Hull Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7171696
15 June 2020
Annual Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 6965301
7 April 2020
Drydock Extension · Administrative Inspection
Administrative · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 6936400
11 June 2019
Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 6658290
3 May 2018
Annual Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 6358793
18 April 2018
Drydock Exam · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6394275
23 February 2017
Deficiency Check · COI Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 6093281
11 May 2016
Deficiency Check
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 5952132
4 May 2016
Deficiency Check · Drydock Exam · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 5869130
31 March 2016
Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 5844243
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 7 May 2025
Resolved
Starboard engine drive fire/bilge pump is operational, however secondary, electric fire/bilge pump is inoperable.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 June 2025
Resolved 19 May 2025
Resolution: Corrected.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 7 May 2025
Resolved
Bilge alarm indicator light for aft compartment is inoperable.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 June 2025
Resolved 19 May 2025
Resolution: Corrected.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 24 March 2023
Resolved
Stbd keel cooler fwd hardware is backed off and post appears to be wasted not allowed for a nut to be installed.
Action required: 705 - Other - as specified
Resolved 19 April 2023
Resolution: This is a zinc stand off, MI cleared WL item.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 11 June 2019
Resolved
Exhuast piping must not leak from any point. Port main engine and generator exhuast piping shows signs of excessive pitting and corrosion. Repair/Replace as discussed.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 June 2019
Resolved 5 July 2019
Resolution: O/O replaced pitted exhaust piping
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 11 June 2019
Resolved
Child life jackets shall be at least 10% of the number of persons permitted onboard. Replace 03 child life jackets due to wear.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 June 2019
Resolved 5 July 2019
Resolution: O/O replaced failed PFD's
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 17 March 2017
Resolved
Conduct MOB Drills with CG Marine Inspector in attendance prior to carrying passengers.
Action required: 705 - Other - as specified
Due 17 March 2017
Resolved 21 April 2017
Resolution: completed underway MOB, Fire and Abandon ship drills.
Communications › Radio Communications › VHF Radiotelephone
Issued 31 March 2016
Resolved
Vessel must have a VHF Radio with DSC. Install apporved radio type.
Due 30 April 2016
Resolved 11 May 2016
Resolution: Cleared by GS-12 Giles Loftin.