Records from 2011 to 2026. Most recent: inspection, 15 July 2026.
Everything above is free. The detail below — the inspection history, the deficiency record, the casualty record and the documentation record — is Professional, $39 a month. Sign in.
Inspection history · 22
15 July 2026
Deficiency Check
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 8439693
9 April 2026
Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 8294722
10 July 2025
Annual Inspection · MTSA Verification · Deficiency Check
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 8146528
4 April 2025
Examination of Repairs · Internal Structural Exam · Hull Examination
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 8105199
26 June 2024
Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 7923908
15 February 2024
Drydock Exam · Examination of Repairs
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 7866114
13 April 2023
Annual Inspection · Deficiency Check · MTSA Verification
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 7667720
7 July 2022
Type not recorded
No type recorded · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 7500715
24 May 2022
DAPI Audit
Administrative · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 7459542
6 April 2022
MTSA Verification · COI Inspection
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 7417101
29 June 2021
Annual Inspection · MTSA Verification · DAPI Audit · Deficiency Check
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 7218603
12 November 2020
Internal Structural Exam · Examination of Repairs · Drydock Exam
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 7094760
4 June 2020
Annual Inspection · MTSA Verification
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 6968182
28 April 2020
Drydock Extension
Administrative · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 6947758
17 June 2019
MTSA Verification · Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 6716575
1 October 2018
Hull Examination
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 6552513
15 May 2018
Drydock Extension
Administrative · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 6415022
9 March 2018
Annual Inspection · Deficiency Check · MTSA Verification
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 6369100
15 March 2017
MTSA Verification · COI Inspection
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 6105175
12 May 2016
Annual Inspection · MTSA Verification · Hull Examination
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 5874984
14 April 2016
Administrative Inspection
Administrative · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 5854007
10 April 2016
Drydock Extension
Administrative · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 5826265
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 9 April 2026
Resolved
At each annual inspection, the inspector must ensure that the tests and inspections of fire detection and extinguishing equipment have been conducted. The time delay for the Fixed fire extinguishing system in the engine room released too early. Replace time delay and submit a tech report to the satisfaction of the attending Marine inspector.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 15 July 2026
Resolution: Time delay was replaced.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 9 April 2026
Resolved
The spring in a relief valve in service for pressures up to and including 250 pounds per square inch must not be reset for any pressure more than 10 percent above or 10 percent below that for which the relief valve is marked. The relief valve on the aft pressure vessel did not relieve within 10% of its marking. Repair or replace valve to the satisfaction of the attending marine inspector.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 21 April 2026
Resolution: Relief valve was replaced.
10 - Safety of Navigation › N/A - No Subsystem › Magnetic compass
Issued 10 July 2025
Resolved
Prove operation of red light .
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 July 2025
Resolved 5 August 2025
Resolution: Light installed, test sat.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 10 July 2025
Resolved
Prove proper operation of lower port nave light.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 July 2025
Resolved 5 August 2025
Resolution: Lights test sat.
10 - Safety of Navigation › N/A - No Subsystem › Magnetic compass
Issued 10 July 2025
Resolved
Prove accurate compass deviation table dated 5/4/2017 post vessel hull repairs from yard peroids.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 July 2025
Resolved 5 August 2025
Resolution: New table on vessel 7/23/2025
09 - Working and Living Conditions › 092 - Working Conditions › Warning notices
Issued 10 July 2025
Resolved
All lifeboat placards refresh labels.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 July 2025
Resolved 7 August 2025
Resolution: placards refreshed.
10 - Safety of Navigation › N/A - No Subsystem › Rudder angle indicator
Issued 10 July 2025
Resolved
Stbd wing station, repair / replace hangs up at 20 deg port.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 July 2025
Resolved 7 August 2025
Resolution: Proper operation of wing station.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 10 July 2025
Resolved
Provide 2 flares to meet requirement.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 July 2025
Resolved 7 August 2025
Resolution: 2 Flares supplied to vessel.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 10 July 2025
Resolved
Label as needed life jacket storage / size and quantities.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 August 2025
Resolved 5 August 2025
Resolution: Label of storage boxes completed.
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 13 April 2023
Resolved
Program AIS with correct call sign.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 May 2023
Resolved 17 April 2023
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 13 April 2023
Resolved
Ensure required safety checks are logged (vessel log and lifesaving equipment check logbook).
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 May 2023
Resolved 23 May 2023
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 13 April 2023
Resolved
e generator not providing power to e bus, manual setting of breaker is required. Provide repair for auto switching of e circuit.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 April 2023
Resolved 14 April 2023
Resolution: Fuse replaced, test sat.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Lashing material
Issued 6 April 2022
Resolved
Found auto safety nets fraying, repair replace with proper size and safety rated components. Compplete at next credit drydock.
Action required: 705 - Other - as specified
Due 30 June 2022
Resolved 15 August 2022
Resolution: New nets installed.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 6 April 2022
Resolved
Found a holed fire main supply pipe to auto sprinkler regulator. Repair replace prove proper operation to CG Inspector. Note: Temporary repair sat. Permanent repair to be completed at next credit drydock.
Action required: 705 - Other - as specified
Due 30 June 2022
Resolved 15 August 2022
Resolution: Repaired and test sat.
04 - Emergency Systems › N/A - No Subsystem › Public address system
Issued 29 June 2021
Resolved
Found PA system inop, repair / replace, prove proper operation.
Action required: 705 - Other - as specified
Resolved 19 July 2021
Resolution: Operation test of PA system completed, test sat.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 25 June 2019
Resolved
Provide valid FCC Safety and Bridge to Bridge Certificates.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 July 2019
Resolved 29 August 2019
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 25 June 2019
Resolved
Replace ring buoy on main deck aft.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 July 2019
Resolved 16 September 2019
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 25 June 2019
Resolved
Restencil PFDs with vessel name.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 June 2019
Resolved 16 September 2019
Fire Fighting › Fire Hydrants › Condition
Issued 5 April 2018
Resolved
Repair leak on hydrant/nipple, Fire Station #9.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 May 2018
Resolved 20 April 2018
Resolution: Nipple replaced.
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 5 April 2018
Resolved
Conduct boat drill with USCG attendance.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 May 2018
Resolved 19 April 2018
Resolution: Conducted satisfactory drill.
Documentation › Certificates/Documents › FCC SSL
Issued 5 April 2018
Resolved
Provide valid FCC Station License.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 May 2018
Resolved 11 May 2018
Fire Fighting › Automatic Sprinkler System › Sprinklers
Issued 9 March 2018
Resolved
Two car deck sprinkler heads were found clogged preventing coverage of deck. Remove debris from sprinkler nozzles.
Action required: 10 - Deficiency Rectified
Due 5 April 2018
Resolved 5 April 2018
Resolution: Heads removed, cleaned, reinstalled and tested sat.
Engineering › Shafting/Propeller Arrangements › Stern Gland
Issued 6 April 2017
Resolved
Provide a replacement nut & jam nut on the port shaft stern tube gland.
Action required: 705 - Other - as specified
Due 6 May 2017
Resolved 19 May 2017
Resolution: Attended vessel. Nuts are in place.
Communications › Alarms/Indicators › Lube Oil Low Pressure Alarm
Issued 6 April 2017
Resolved
Alarms for the #1 genset do not alarm in the E/R, repair as orginal
Action required: 705 - Other - as specified
Due 6 May 2017
Resolved 19 May 2017
Resolution: Attended vessel. Tested alarms sat.
Accommodation/Occupational Safety › Occupational Safety › Rubbish/Waste Materials
Issued 6 April 2017
Resolved
Remove the flammable liquids from the E/R control room
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 6 May 2017
Resolved 19 May 2017
Resolution: Attended vessel. Items have been removed.
Construction/Loadline › Structures › Longitudinal Bulkhead
Issued 6 April 2017
Resolved
Fuel tank bulkhead vert stiffeners were cracked at the top of the stiffener in shaft alley.
Action required: 705 - Other - as specified
Due 6 May 2017
Resolved 19 May 2017
Resolution: Attended vessel. Stanchions are rewelded.
Fire Fighting › Fixed Fire Detection System › Heat Detectors
Issued 6 April 2017
Resolved
As noted on the E/R fire plan, a dectector was missing above the port MDE.
Action required: 705 - Other - as specified
Due 6 June 2017
Resolved 19 May 2017
Resolution: Attended vessel. Detector is now in place.
Engineering › Pressure Vessel › Relief Valve
Issued 6 April 2017
Resolved
Relief valves shall be adjusted or replaced to open below the pressure vessel MAWP.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 6 May 2017
Resolved 19 May 2017
Resolution: Attended vessel. 175 psi relief valves (new) installed).
Accommodation/Occupational Safety › Other Accommodation Spaces › Open Deck Space
Issued 6 April 2017
Resolved
Ensure upper deck is marked with max. passenger count.
Action required: 705 - Other - as specified
Due 6 May 2017
Resolved 23 June 2017
Communications › Alarms/Indicators › General Alarm
Issued 6 April 2017
Resolved
Prove operation of General Alarm in engine room.
Action required: 705 - Other - as specified
Due 13 April 2017
Resolved 19 May 2017
Resolution: Attended vessel. GA bell is new and operational.
Fire Fighting › Fire Hydrants › Condition
Issued 6 April 2017
Resolved
Replace/Repair valve on #2 fire station.
Due 13 April 2017
Resolved 19 May 2017
Resolution: Attended vessel. Valve has been replaced.
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 6 April 2017
Resolved
Post proper donning placards at stowage locations.
Due 6 May 2017
Resolved 19 May 2017
Resolution: Attended vessel. Placards are posted.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Service
Issued 6 April 2017
Resolved
Provide B-II extinguisher and new bracket at vehicle deck, stbd. side.
Due 13 April 2017
Resolved 19 May 2017
Resolution: Attended vessel. New unit installed.
Navigation › Piloting/Steering › Deviation Table/Graph
Issued 6 April 2017
Resolved
Provide updated deviation table.
Due 6 May 2017
Resolved 4 May 2017
Resolution: New table provided.
Lifesaving › Lifejacket/PFD (Type I) › Storage
Issued 6 April 2017
Resolved
Service cover for main deck lifejacket stowage.
Due 6 May 2017
Resolved 23 June 2017
Electrical › Electrical Distribution System (emergency) › Cable
Issued 20 July 2016
Resolved
Address dead end wires and poor connections on navigation battery.
Due 27 July 2016
Resolved 2 August 2016
Resolution: Attended vessel. Connections renewed.
Lifesaving › Hand Flares › Storage
Issued 20 July 2016
Resolved
Provide brightly colored container for flares.
Due 20 August 2016
Resolved 2 August 2016
Resolution: Attended vessel. New box provided.
Lifesaving › Lifejacket/PFD (Type I) › Storage
Issued 20 July 2016
Resolved
Label main deck stowage for PFDs.
Due 20 August 2016
Resolved 2 August 2016
Resolution: Attended vessel. PFD stowage is labeled.
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 20 July 2016
Resolved
Segregate adult and child PFDs.
Due 20 August 2016
Resolved 2 August 2016
Resolution: Attended vessel. Chile/Adult PFDs are seperated.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 20 July 2016
Resolved
Repair/Replace ring buoy waterlight on port bow.
Due 27 July 2016
Resolved 2 August 2016
Resolution: Attended vessel. Light is operational.
Fire Fighting › Nozzles › Condition
Issued 20 July 2016
Resolved
Provide chains for tips on nozzles.
Due 20 August 2016
Resolved 2 August 2016
Resolution: Chains are on nozzles.
Lifesaving › Inflatable Buoyant Apparatus › Stowage
Issued 20 July 2016
Resolved
Ensure IBA stanchions move freely.
Due 27 July 2016
Resolved 2 August 2016
Resolution: Stanchions now move freely.
Fire Fighting › Nozzles › Condition
Issued 20 July 2016
Resolved
Repair/Replace nozzle at F.S. #4.
Due 22 July 2016
Resolved 2 August 2016
Resolution: Attended vessel. Nozzle replaced.
Communications › Alarms/Indicators › General Alarm
Issued 12 May 2016
Resolved
Label General Alarm on aft/upper deck with appropriate verbiage.
Due 20 August 2016
Resolved 2 August 2016
Resolution: Attended vessel. alaram is labeled.