Records from 1987 to 2004. Most recent: inspection, 3 November 2004.
Inspection history · 60
3 November 2004
Internal Structural Exam · MTSA/ISPS Verification · Annual Inspection · Cargo Tank Internal · Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 2233648
25 June 2004
Annual Inspection · MARPOL Annex I Examination · MARPOL Annex II Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2110223
13 February 2004
Administrative Inspection
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2006109
9 December 2003
Construction Oversight
Physical examination · MIDET HARVEY CANAL DETAIL · USCG Heartland District (CGD-H) · Activity 1961041
11 August 2003
Administrative Inspection
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1873357
18 July 2003
Administrative Inspection
Administrative · MIDET HARVEY CANAL DETAIL · USCG Heartland District (CGD-H) · Activity 1850170
22 April 2003
Internal Structural Exam
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1778512
13 December 2002
Administrative Inspection
Administrative · MIDET HARVEY CANAL DETAIL · USCG Heartland District (CGD-H) · Activity 1718435
17 October 2002
Annual Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1694241
27 August 2002
Administrative Inspection
Administrative · MIDET WEST DETAIL · USCG Heartland District (CGD-H) · Activity 1667511
25 April 2002
Administrative Inspection
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1609340
19 March 2002
In-Service Inspection
Physical examination · MIDET WEST DETAIL · USCG Heartland District (CGD-H) · Activity 1494762
15 November 2001
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1075907
9 November 2001
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1076821
6 November 2001
Re-Inspection · Deficiency Check
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1412380
17 October 2001
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1074967
16 July 2001
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1067248
9 July 2001
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1425116
10 January 2001
Examination of Repairs
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1415524
2 October 2000
COI Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1448176
7 June 2000
Hull Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1436396
19 April 2000
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 770623
9 April 2000
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 211600
21 March 2000
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1047650
10 March 2000
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1438986
12 October 1999
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1378830
25 August 1999
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 780651
13 April 1999
Examination of Repairs
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 788417
29 October 1998
Deficiency Check · Hull Examination · COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1411757
14 June 1998
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1607
22 May 1998
Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 791948
13 April 1998
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1409875
27 August 1997
Administrative
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1120871
13 August 1997
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 47450
21 July 1997
COI Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1392734
26 February 1997
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1104077
20 August 1996
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 36882
21 June 1996
Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1419625
12 January 1996
Deficiency Check
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 873848
7 December 1995
Administrative
Administrative · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1464608
27 November 1995
Deficiency Check
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1190791
28 September 1995
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1187157
11 September 1995
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 498322
21 July 1995
COI Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1192360
21 June 1995
Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 880467
18 April 1995
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 869453
23 December 1992
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1142515
23 May 1991
COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 917256
17 July 1990
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1210839
25 May 1990
Re-Inspection · Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1211101
1 May 1990
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 905329
30 March 1990
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1211223
6 October 1989
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1039022
20 July 1989
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1202097
31 May 1989
COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1348451
17 October 1988
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1201890
30 September 1988
Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 886804
30 December 1987
Administrative
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1315260
9 September 1987
Administrative
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1003362
4 June 1987
Hull Examination · Initial Certification
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1010427
Electrical › Electrical Distribution System (service) › Ground Detection
Issued 25 June 2004
Resolved
Reapir ground detection lights on control panel for auxiliary generator to satisfaction of CG marine inspector.
Action required: 705 - Other - as specified
Resolved 25 June 2004
Deck/Cargo › Mooring/Anchoring
Issued 17 October 2002
Resolved
Make repairs to anchor windlass brake band prior to departure. LEGACY COMPONENT DESC: Brake
Action required: 17 - Rectify deficiencies prior to departure
Resolved 23 October 2002
Resolution: Tested windlass with sat results.
Electrical › Lighting (service)
Issued 17 October 2002
Resolved
Make repairs or remove broken light fixture in starboard cargo pump house. LEGACY COMPONENT DESC: Lighting Fixture
Condition: Damaged By Earlier Event
Due 17 November 2002
Resolved 23 October 2002
Resolution: Lighting fixture was removed from compartment.
Electrical › Electric Generation Source (service)
Issued 17 October 2002
Resolved
Prove proper operation of both vessel service generators (low lube and overspeed shutdowns) in presence of attending marine inspector. LEGACY COMPONENT DESC: Shutdowns
Action required: 17 - Rectify deficiencies prior to departure
Resolved 23 October 2002
Resolution: Witnessed overspeed and low lube shutdows for both generators.
Operations/Management › Cargo Transfer/Lightering
Issued 17 October 2002
Resolved
Provide copy of PIC listing. LEGACY COMPONENT DESC: Person in Charge Presence/Supervision
Due 2 November 2002
Resolved 23 October 2002
Resolution: Verified PIC listing.
Operations/Management › Cargo Transfer/Lightering
Issued 17 October 2002
Resolved
Provide on board the vessel a complete copy of vessel transfer procedures. LEGACY COMPONENT DESC: Vessel Transfer Procedures on Hand
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 23 October 2002
Resolution: Verified transfer procedures are onboard.
Deck/Cargo
Issued 6 November 2001
Resolved
RENEW EXHAUST PIPING ON STBD CARGO PUMP ENGINE TO THE SATISFACTION OF THE COGNIZANT OCMI.
Condition: Unknown
Due 6 November 2001
Resolved 6 November 2001
Deck/Cargo
Issued 7 June 2000
Resolved
INSTALL POSITION INDICATORS ON ALL CARGO VALVES.
Condition: Unknown
Due 7 June 2000
Resolved 7 June 2000
Deck/Cargo
Issued 12 October 1999
Resolved
STEAM TRAPS CORRODED BEYOND REPAIR. Steam System for cargo heating not to be used until all deficient steam traps are replaced, and system is tested to the staisfaction of attending Marine Inspector.
Condition: Unknown
Due 12 October 1999
Resolved 12 October 1999
Fire Fighting
Issued 29 October 1998
Resolved
PROVIDE 'CG' APPROVED PLANS FOR THE FIXED CO2 SYSTEM IN THE BOW THRUSTER ROOM.
Condition: Unknown
Due 28 November 1998
Resolved 10 November 1998
Engineering
Issued 29 October 1998
Resolved
PREPARE AND SUBMIT AUTOMATION TEST PROCEDURES FOR AUXILIARY BOILER.
Condition: Unknown
Due 28 November 1998
Resolved 10 November 1998
Electrical
Issued 29 October 1998
Resolved
PREPARE AND SUBMIT AUTOMATION TEST PROCEDURES FOR THE FOLLOWING DIESEL ENGINES: BOW THRUSTER, #1 GENERATOR, #2 GENERATOR, AND AUXILIARY GENERATOR.
Condition: Unknown
Due 28 November 1998
Resolved 10 November 1998
Construction/Loadline
Issued 13 April 1998
Resolved
CROP AND RENEW TRANSVERSE FRAME IN UPPER OUTBOARD BAY #4 BETWEEN THE #4 AND#5 SIDE LONGS IN STBD WING VOID #1. TO BE ACCOMPLISHED AT SCHEDULED DRYDOCK IN JUNE 1998._x001C_ _x001C_
Condition: Unknown
Due 13 April 1998
Resolved 13 April 1998
Construction/Loadline
Issued 13 April 1998
Resolved
CROP AND RENEW #1 AND #2 SIDE LONGS AND TRANSVERSE TIE IN #1 OUTBOARD BOTTOM BAY IN THE #5 STBD WING VOID. TO BE COMPLETED AT SCHEDULED DRYDOCK IN JUNE 1998._x001C_ _x001C_
Condition: Unknown
Due 13 April 1998
Resolved 13 April 1998
Engineering
Issued 7 December 1995
Resolved
PER 46 CFR 111.103-3 AND 111.103-9, INSTALL PROPER CONTROLS TO STOP THE BOILER SPACE VENTILATORS. INSTALLATION IS TO BE MADE IN ACCORDANCE WITH USCG MARINE SAFETY CENTER-APPROVED PLANS. INSTALLATION AND WORKMANSHIP IS TO BE TO THE SATISFACTION OF THE ATTENDING USCG MARINE INSPECTOR.
Condition: Unknown
Due 7 February 1996
Resolved 11 December 1995
Engineering
Issued 7 December 1995
Resolved
THE CARGO HEATING BOILER SHALL REMAIN SECURED FROM SERVICE AT ALL TIMES WHEN THE BARGE IS UNDERWAY UNTIL REQUIREMENTS M001 AND M004 HAVE BEEN SATISFIED.
Condition: Unknown
Due 7 December 1995
Resolved 7 December 1995
Construction/Loadline
Issued 7 December 1995
Resolved
SUBMIT WRITTEN PROOF FROM THE AMERICAN BUREAU OF SHIPPING THAT ALL DECK PENETRATIONS, VENTS, FUNNELS, ETC. ASSOCIATED WITH THE INSTALLATION OF THE BOILER SPACE VENTILATION SYSTEM ARE IN KEEPING WITH ALL APPLICABLE BUREAU RULES WITH RESPECT TO THE ASSIGNMENT OF THE LOADLINE TO THIS VESSEL.
Condition: Unknown
Due 7 December 1995
Resolved 7 December 1995
Engineering
Issued 7 December 1995
Resolved
SUBMIT FOR APPROVAL ELECTRICAL PLANS, COMPLETE WITH LOAD ANALYSIS, TO USCG MARINE SAFETY CENTER FOR INSTALLATION OF VENTILATORS FOR BOILER SPACE. INSTALLATION OF ALL WIRING, PANELS, CONTROLLERS, ETC. TO BE IN ACCORDANCE WITH APPROVED PLANS AND TO THE SATISFACTION OF USCG MARINE INSPECTOR.
Condition: Unknown
Due 7 February 1996
Resolved 11 December 1995
Engineering
Issued 7 December 1995
Resolved
INSTALL USCG MSC-APPROVED VENTILATION SYSTEM TO CARGO BOILER SPACE IN ACCORDANCE WITH 46 CFR 32.55. WORKMANSHIP AND INSTALLATION ARE TO BE TO THE SATISFACTION OF ATTENDING USCG MARINE INSPECTOR.
Condition: Unknown
Due 7 December 1995
Resolved 7 December 1995
Engineering
Issued 21 July 1995
Resolved
CARGO HEATING BOILER WILL REMAIN INOPERATIVE UNTIL ALL ITEMS IN QUESTION BYABS AND USCG MARINE SAFETY CENTER ARE SATISFIED.
Condition: Unknown
Due 21 July 1995
Resolved 21 July 1995
Construction/Loadline
Issued 30 March 1990
Resolved
COMPLETE COAST GUARD APPROVED PERMANENT REPAIR IN WB1S AND WB1P NO LATER THAN 30 SEP 90.
Condition: Unknown
Due 30 March 1990
Resolved 30 March 1990
Construction/Loadline
Issued 30 March 1990
Resolved
PROVIDE PROPOSAL FOR PERMANENT REPAIR OF STRUCTURAL FAILURE IN WB1S & WB1P WITH PRIOR ABS APPROVAL TO THE [name withheld] 30 MAY 90.
Condition: Unknown
Due 30 March 1990
Resolved 30 March 1990
Electrical
Issued 31 May 1989
Resolved
PROVIDE A MEANS TO BLEED OFF PRESSURE FROM THE LUBE OIL SENSOR OF THE GENERATORS #1,2, AND 3 AND PROVE PROPER OPERATION OF THE LOW PRESSURE ALARMAND SHUTDOWN DEVICES.
Condition: Unknown
Due 31 May 1989
Resolved 31 May 1989
Electrical
Issued 31 May 1989
Resolved
PROVIDE ELECTRIC INSULATING MAT FOR DECK IN FRONT OF MAIN SWITCH BOARD.
Condition: Unknown
Due 31 May 1989
Resolved 31 May 1989
Construction/Loadline
Issued 31 May 1989
Resolved
PAINT LOADLINE AND VESSEL NAME CONTRASTING COLORS TO THE HULL WHERE IMPROPER OR WORN OFF ON PORT AND STBD SIDES.
Condition: Unknown
Due 31 May 1989
Resolved 31 May 1989
Electrical
Issued 31 May 1989
Resolved
PROVIDE COVER FOR MAIN SWITCHBOARD OPEN SPARE CIRCUIT BREAKER.
Condition: Unknown
Due 31 May 1989
Resolved 31 May 1989
Documentation
Issued 31 May 1989
Resolved
PROVIDE ORIGINAL IOPP FORM "A" SUPPLEMENT ONBOARD.
Condition: Unknown
Due 31 May 1989
Resolved 31 May 1989
Fire Fighting
Issued 31 May 1989
Resolved
REPAIR AS NECESSARY AND PROVE PROPER OPERATION OF THE AFT FIXED CO2 SMOTHERING FLAME SENSING ACTIVATION SYSTEM.
Condition: Unknown
Due 19 March 2002
Resolved 19 March 2002
Documentation
Issued 30 September 1988
Resolved
PROVE PROPER POSSESSION OF VALID CERTIFICATE OF DOCUMENTATION. THIS DOCUMENT, IN ORIGINAL ONLY, MUST BE ATTAINED BEFORE BARGE IS TO BE PUT BACK IN SERVICE
Condition: Unknown
Due 30 September 1988
Resolved 30 September 1988
Documentation
Issued 4 June 1987
Resolved
PROVIDE ABS/USCG APPROVAL FOR ABS LTR TO INTERNATIONAL SWTICHBOARD CORP., HOUSTON, TX DTD 3FEB87 (HR/KL/T-8-2, P-302456, 6-16327).
Condition: Unknown
Due 4 June 1987
Resolved 4 June 1987
Documentation
Issued 4 June 1987
Resolved
PROVIDE ABS/USCG APPROVAL FOR ABS LTR TO FELS DTD 20NOV86 (HR/KL/T-8-2) REGARDING - DWG SK-E2, NAVIGATION LIGHT CONTROL PANEL DETAILS.
Condition: Unknown
Due 4 June 1987
Resolved 4 June 1987
Documentation
Issued 4 June 1987
Resolved
PROVIDE ABS/USCG APPROVAL FOR ABS LTR TO FELS DTD 21JAN87 (HR/MKR/302456/ T-8-2, 6-15212) REGARDING - DWG E-7, REV. 0, ARRGT LIGHTING DWG E-8, REV. 0, MASTER WAY
Condition: Unknown
Due 4 June 1987
Resolved 4 June 1987
Documentation
Issued 4 June 1987
Resolved
PROVIDE ABS/USCG APPROVAL FOR ABS LTR TO FELS DTD 21JAN87 (HR/MKR/302456/ T-8-2, 6164931) REGARDING - DWG E-5, SCHEMATIC & ARRGT CO2, ELECTRIC CONTROL.
Condition: Unknown
Due 4 June 1987
Resolved 4 June 1987
Documentation
Issued 4 June 1987
Resolved
PROVIDE ABS/USCG APPROVAL FOR ABS LTR TO FELS DTD 21JAN87 (HR/MKR/302456/ T-8-2, 6-15365) REGARDING - DWG E-9, REV. 0, ARGT OF ELECTRICAL EQUIPMENT.
Condition: Unknown
Due 4 June 1987
Resolved 4 June 1987
Documentation
Issued 4 June 1987
Resolved
PROVIDE ABS/USCG APPROVAL FOR ABS LTR TO FELS DTD 27JAN87 (HR/DSL/MKR/ P-302456/T-8-2, L-16770) REGARDING - DWG P206-01, TELEMETRY SENSORS MOUNTING.
Condition: Unknown
Due 4 June 1987
Resolved 4 June 1987
Documentation
Issued 4 June 1987
Resolved
PROVIDE ABS/USCG APPROVAL FOR ABS LTR TO FELS DTD 29JAN87 (HR/MKR/302456/ T-8-2, 6-17465) REGARDING DWG E3, REV.0, SCHEMATIC & ARRGT ANCHOR WINDLASS DWG E6, REV.0, SCHEMATIC & ARRGT TELEMETRY SYSTEM
Condition: Unknown
Due 4 June 1987
Resolved 4 June 1987
Documentation
Issued 4 June 1987
Resolved
OBTAIN AND PLACE ON BOARD U.S. COAST GUARD CERTIFICATE OF DOCUMENTATION.
Condition: Unknown
Due 4 June 1987
Resolved 4 June 1987
Documentation
Issued 4 June 1987
Resolved
PROVIDE ABS/USCG APPROVAL FOR ABS LTR TO FELS DTD 4MAR87 (DSL/KL, P-302456,T-8-2, L-18089) REGARDING - DWG P207-01, P207-03, MANHOLE OPENING INSIDE OFD.O. SERVICE TANK.
Condition: Unknown
Due 4 June 1987
Resolved 4 June 1987
Documentation
Issued 4 June 1987
Resolved
PROVIDE ABS/USCG APPROVAL FOR ABS LTR TO J.B. COMPANY, INC. SLIDELL, LA DTD 5MAR87 (LCS/VAA/ADL/P-302456/T-8-2, L-16411, 17995) REGARDING - DWG V-236, SLUDGE DUMP VALVES.
Condition: Unknown
Due 4 June 1987
Resolved 4 June 1987
Documentation
Issued 4 June 1987
Resolved
PROVIDE ABS/USCG APPROVAL FOR ABS LTR TO FELS DTD 13FEB87 (DSL/CG/P-302456/T-8-2, L-1777) REGARDING - DWG P115-01, DIAGRAM HYDRAULIC PIPING SYSTEM.
Condition: Unknown
Due 4 June 1987
Resolved 4 June 1987
Documentation
Issued 4 June 1987
Resolved
PROVIDE ABS/USCG APPROVAL FOR ABS LTR TO J.B. COMPANY, INC. SLIDELL, LA DTD 13FEB87 (HR/DSL/CG/P-302456/T-8-2, L-16410) REGARDING - DWG M244-H01 DWG 244-E01
Condition: Unknown
Due 4 June 1987
Resolved 4 June 1987
Documentation
Issued 4 June 1987
Resolved
PROVIDE ABS/USCG APPROVAL FOR ABS LTR TO FELS DTD 27JAN87 (HR/MKR/P-302456/T-8-2, 6-16183) REGARDING - DWG E-2, REV. 0, SCHEMATIC & ARRGT BOW THRUSTERCONTROL.
Condition: Unknown
Due 4 June 1987
Resolved 4 June 1987
Documentation
Issued 4 June 1987
Resolved
PROVIDE ABS/USCG APPROVAL FOR ABS LTR TO FELS DTD 3FEB87 (HR/MKR/P-302456/ T-8-2, 6-14414) REGARDING - DWG E1, ALT. 0, SCHEMATIC ELECTRICAL PANEL DISTRIBUTION.
Condition: Unknown
Due 4 June 1987
Resolved 4 June 1987