DUC D' ORLEANS II

DUC D' ORLEANS II is a 1987 passenger vessel (inspected). The Coast Guard has recorded 5 inspections since 2016, most recently in June 2019, along with 7 deficiencies.

Records from 2016 to 2019. Most recent: inspection, 18 June 2019.

Built
1987
Last inspected
18 June 2019
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Identity

CSN4477
281889
Flag
CANADA
Maury page id
psix-281889

This record may be incomplete: the most recent inspection recorded for this vessel was 7 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspections, by type

Years with a record 4 calendar years (2016–2019)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. The counts in the strip above are the same counts; this table splits the inspections by the kind of activity recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Documentation record

Tonnage as PSIX records it39 - Regulatory (Subpart C or D), Net Ton
57 - Regulatory (Subpart C or D), Gross Ton
119 - Convention (Subpart B), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report

A report is not offered for this hull. Its record holds only 1 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 5

18 June 2019 COC-CVE Annual
Administrative · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 6717871
25 May 2018 COC-CVE Annual
Administrative · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 6420396
26 May 2017 COC-CVE Annual
Administrative · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 6155500
21 July 2016 Deficiency Check
Physical examination · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 5947973
26 May 2016 COC-CVE Annual
Administrative · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 5887129

Deficiency record · 7

Lifesaving › Lifejacket/PFD (Type I) › Retroreflective Material
Issued 26 May 2016 Resolved
Owner to replace all reflective material with retro-reflective material on the Adult Type I and child Type I PFD's. Evidence of severe deterioration on old material was basis for renewal requirement.
Action required: 705 - Other - as specified
Due 27 June 2016
Resolved 26 June 2016
Fire Fighting › Fire Main › Valves
Issued 26 May 2016 Resolved
Fire Station Control Valve #1 is cracked due to ice damage. Renew as required by Flag.
Action required: 705 - Other - as specified
Due 27 June 2016
Resolved 26 June 2016
Fire Fighting › Fire Hoses › Condition
Issued 26 May 2016 Resolved
Renew fire hose on primary deck fire station #1.
Action required: 705 - Other - as specified
Due 27 June 2016
Resolved 26 June 2016
Lifesaving › Inflatable Liferafts › Approval
Issued 26 May 2016 Resolved
Provide documentation attesting to Flag acceptance of service interval extension.
Action required: 705 - Other - as specified
Due 27 June 2016
Resolved 26 June 2016
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 26 May 2016 Resolved
Replace ring life buoy grab lines with approved floating UV resistant line.
Action required: 705 - Other - as specified
Due 27 June 2016
Resolved 26 June 2016
Fire Fighting › Fire Pumps › Pressure
Issued 26 May 2016 Resolved
Engine driven fire pump gasket was leaking during the fire pump test. Renew gasket. Owner required the engine to be increased to around 2700 RPM to produce adequate pressure. Ensure impeller is in good working order.
Action required: 705 - Other - as specified
Due 27 June 2016
Resolved 26 June 2016
Engineering › Freshwater System (jacketwater cooling) › Pump
Issued 26 May 2016 Resolved
Make permenant repairs to starboard main engine cooling water pump at hose clamp. Leak was observed during the fire pump test.
Action required: 705 - Other - as specified
Due 27 June 2016
Resolved 26 June 2016