MAURY USCG vessel records Sign in
← All vessels

YANNIS

YANNIS is a 1984 freight ship. The Coast Guard has recorded 23 inspections since 1987, most recently in October 2007, along with 46 deficiencies — 2 with no resolution recorded — and 3 operational controls.

Records from 1987 to 2007. Most recent: inspection, 3 October 2007.

Built
1984
Last inspected
3 October 2007
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

8313520 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
281921
Flag
MALTA
—
Maury page id
psix-281921

Inspections, by type

…with no type recorded17
…past their stated due date2
Years with a record 10 calendar years (1987–2007)
The 23 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 19 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 1981.

Documentation record

Tonnage as PSIX records it9053 - Convention (Subpart B), Net Ton
16502 - Convention (Subpart B), Gross Ton
24839 - Dead Weight, Metric Ton
32916 - Displacement, Metric Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 23

3 October 2007 MARPOL Annex V Examination · Ballast Water Examination · PII Safety Exam · MARPOL Annex I Examination · ISPS II Exam
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 3066464
17 June 2006 PII Safety Exam · Deficiency Check · MARPOL Annex V Examination · ISPS II Exam · MARPOL Annex I Examination · Ballast Water Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2682224
14 January 2003 Ballast Water Examination · Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1730495
8 January 2003 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1728867
10 October 2002 Ballast Water Examination · Deficiency Check · Annual Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1688164
7 October 2002 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1704430
27 June 2000 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 279396
16 November 1998 Type not recorded
No type recorded · MSO CLEVELAND · USCG Great Lakes District (CGD-GL) · Activity 422442
22 September 1998 Type not recorded
No type recorded · MSO CLEVELAND · USCG Great Lakes District (CGD-GL) · Activity 727290
17 September 1998 Type not recorded
No type recorded · MSO CLEVELAND · USCG Great Lakes District (CGD-GL) · Activity 420339
12 July 1998 Type not recorded
No type recorded · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 417874
7 May 1998 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 416113
4 May 1998 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 113649
18 August 1997 Type not recorded
No type recorded · MSO DETROIT · USCG Great Lakes District (CGD-GL) · Activity 406992
15 August 1997 Type not recorded
No type recorded · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 406728
4 August 1997 Type not recorded
No type recorded · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 406259
14 April 1997 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 401673
1 July 1996 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 392698
1 July 1996 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 392909
17 December 1994 Uninspected Other
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1394238
28 November 1994 Type not recorded
No type recorded · COTP LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 372532
28 November 1994 MARPOL Annex V Examination · MARPOL Annex I Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1177679
4 July 1987 Type not recorded
No type recorded · COTP HOUSTON · USCG Heartland District (CGD-H) · Activity 317154

Deficiency record · 46

Lifesaving › Lifeboat › Propulsion Engine
Issued 3 October 2007 Resolved
Port side lifeboat unable to be started. Technician is currently on board and currently attempting repairs. Life boat is to be fully operational prior to departure from the Port of Corpus Christi. Deficiency is to be addressed by attending classification society.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 3 October 2007
Resolution: Received a class report satisfying the requirement.
Engineering › Diesel Engine (propulsion-direct drive) › Bearing
Issued 14 January 2003 No resolution recorded
The main engine intermediate wheel shaft roller bearing failed due to lack of lubrication. Repairs completed and engine was examined and tested with statisfactory results. Class issued condition of class to have the engine further examined at the forthcoming drydock MAR 2003. LEGACY COMPONENT DESC: Bearing
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 March 2003 — due date passed with no resolution recorded
Resolution: Received class report from LR satisfying requirement.
Engineering › Sea-water System (primary cooling) › Pump
Issued 14 January 2003 No resolution recorded
#1 sea water cooling pump for main engine has a patch, consisting of rubber and a metal clamp, that is leaking on the suction side of the pump. Patch re-enforced and leak free. Class issued condition of class to permanently repair by 28 FEB 2003. LEGACY COMPONENT DESC: Pump
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 February 2003 — due date passed with no resolution recorded
Resolution: Received class report from LR satisfying requirement.
Engineering › Sea-water System (primary cooling) › Pump
Issued 14 January 2003 Resolved
#2 sea water cooling pump for main engine is leaking water from the shaft seal. Make repairs to the satisfaction of class prior to departure. Class issued condition of class to renew seal by 28 FEB 2003. LEGACY COMPONENT DESC: Pump
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 February 2003
Resolved 17 June 2006
Resolution: Received class report from LR satisfying requirement.
Engineering › Fuel Oil Service System
Issued 14 January 2003 Resolved
The burner for the boiler is leaking fuel oil onto uninsulated electrical wires. Repair leak and insulate wire prior to departure. LEGACY COMPONENT DESC: Burner
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 14 January 2003
Resolved 15 January 2003
Resolution: Received class report from LR satisfying requirement.
Engineering › Freshwater System (air cooling)
Issued 14 January 2003 Resolved
#3 generator has a leaking soft patch on the inlet water pipe for the air cooler. Repair to the satisfaction of class prior to departure. LEGACY COMPONENT DESC: Piping
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 14 January 2003
Resolved 15 January 2003
Resolution: Received class report from LR satisfying requirement.
Engineering › Freshwater System (air cooling)
Issued 14 January 2003 Resolved
#1 generator has a leaking liquid steel patch on the inlet water pipe for the air cooler. Repair to the satisfaction of class prior to departure. LEGACY COMPONENT DESC: Piping
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 14 January 2003
Resolved 15 January 2003
Resolution: Received class report from LR satisfying requirement.
Engineering › Diesel Engine (propulsion-direct drive) › Injector (fuel injection)
Issued 14 January 2003 Resolved
High pressure fuel lines for #4 and #5 cylinders on main engine are missing the outer jacket or are in poor condition. Install new outer jackets prior to departure. Pipes were temporarily insulated. Class issued condition of class to permanently repair by 28 FEB 2003. LEGACY COMPONENT DESC: Injector (fuel injection)
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 28 February 2003
Resolved 17 June 2006
Resolution: Received class report from LR satisfying requirement.
Engineering › Lubricating Oil Service System › Piping
Issued 14 January 2003 Resolved
#3 generator has a noteworthy oil leak from the bearing from the lubrication pipe. Temporarily repaired and leak free. Class issued condition of class to permanently repair by 28 FEB 2003. LEGACY COMPONENT DESC: Piping
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 February 2003
Resolved 17 June 2006
Resolution: Received class report from LR satisfying requirement.
Engineering › Fuel Oil Service System
Issued 14 January 2003 Resolved
#3 generator has a noteworthy fuel oil leak from the installed filter piping. LEGACY COMPONENT DESC: Filter
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 21 January 2003
Resolved 15 January 2003
Resolution: Received class report from LR satisfying requirement.
Engineering › Generator (propulsion/auxiliary-electric)
Issued 14 January 2003 Resolved
#1 generator has a water leak from the installed water pump. LEGACY COMPONENT DESC: Water pump
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 21 January 2003
Resolved 15 January 2003
Resolution: Received class report from LR satisfying requirement.
Engineering › Generator (propulsion/auxiliary-electric)
Issued 14 January 2003 Resolved
#3 generator has a water leak from the installed water pump. LEGACY COMPONENT DESC: Water pump
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 21 January 2003
Resolved 15 January 2003
Resolution: Received class report from LR satisfying requirement.
Engineering › Diesel Engine (propulsion-direct drive) › Piping (exhaust)
Issued 14 January 2003 Resolved
#1 lube oil cooler for main engine has a patch on end bell. Provide class report attesting to the integrity of the patch. Class issued condition of class to permanently repair by 28 FEB 2003. LEGACY COMPONENT DESC: Lube oil cooler
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 February 2003
Resolved 17 June 2006
Resolution: Received class report from LR clearing deficiency.
Fire Fighting › Portable CO2 Fire Extinguisher
Issued 14 January 2003 Resolved
Various portable fire extinguishers (approx. 4) throughout the lower and mid-level engine room are in poor condition. All portable fire extinguishers in the engine room have not been inspected since October 2001. Provide receipt for inspection of all portable fire extinguishers prior to departure. LEGACY COMPONENT DESC: Condition
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 14 January 2003
Resolved 15 January 2003
Resolution: Received class report from LR satisfying requirement.
Navigation › Piloting/Steering
Issued 14 January 2003 Resolved
Gyro compass in steering gear shows 323 and the bridge gyro compass shows 287. Provide tech report attesting to repairs made to gyro. LEGACY COMPONENT DESC: Gyro Compass
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 January 2003
Resolved 15 January 2003
Resolution: Received class report from LR satisfying requirement.
Construction/Loadline › Structures
Issued 14 January 2003 Resolved
Decking underneath the ships sewage system is holed and wasted. Provide report from class attesting to the integrity of this deck prior to departure. LEGACY COMPONENT DESC: Deck Plating
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 14 January 2003
Resolved 15 January 2003
Resolution: Received class report from LR satisfying requirement.
Fire Fighting › Emergency Fire Pumps
Issued 10 October 2002 Resolved
Emergency fire pump unable to provide adequate pressure on two separate occasions. LEGACY COMPONENT DESC: Pressure
Condition: Unknown
Action required: 705 - Other - as specified
Due 16 October 2002
Resolved 11 October 2002
Resolution: Deficiency cleard by LR class report.
Engineering
Issued 10 October 2002 Resolved
Engine room and steering gear have notable amounts of oil on machinery and deck plates. Containment area for D.O. transfer pump is over flowing with D.O.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 October 2002
Resolved 11 October 2002
Resolution: Deficiency cleared by LR class report.
Engineering › Generator (propulsion-electric)
Issued 10 October 2002 Resolved
No. 3 generator has a notable fuel oil leak from the No.1 and No. 4 cylinders.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 October 2002
Resolved 11 October 2002
Resolution: Deficiency cleared by LR class report.
Engineering › Generator (propulsion-electric)
Issued 10 October 2002 Resolved
No. 1 generator has a fuel oil leak from the high pressure line going to the injector nozzle. Vessel is prohibited from operating the No. 3 generator until proper repairs are made to the satisfaction of the administration.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 October 2002
Resolved 11 October 2002
Resolution: Deficiency cleared by LR class report.
Navigation › Emergency Steering
Issued 10 October 2002 Resolved
All 3 installed ways of communication from steering gear to bridge do not work. Vessel must use hand held radios for comms. LEGACY COMPONENT DESC: Communications to Emergency Steering
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 16 October 2002
Resolved 10 October 2002
Resolution: Corrected prior to completion of boarding.
Navigation › Emergency Steering
Issued 10 October 2002 Resolved
The illuminated repeater for the gyro compass in the steering gear is 50 degrees deviated. Provide tech report for proper operation of gyro. LEGACY COMPONENT DESC: Compass Reading for Emergency Steering
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 17 October 2002
Resolved 11 October 2002
Resolution: Deficiency cleared by LR class report.
Construction/Loadline › Hull
Issued 10 October 2002 Resolved
The bulbous bow has two indentations of notable size. Class to attest to the strength/integrity of the damaged area.
Condition: Unknown
Action required: 705 - Other - as specified
Due 16 October 2002
Resolved 11 October 2002
Resolution: Deficiency cleared by LR class report.
Engineering › Sea-water System (primary cooling)
Issued 10 October 2002 Resolved
Sea water intake line for the main engine air-cooler has a soft patch on the flange. LEGACY COMPONENT DESC: Piping
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 17 October 2002
Resolved 11 October 2002
Resolution: Deficiency cleared by LR class report.
Engineering › Fuel Oil Storage/Transfer System
Issued 10 October 2002 Resolved
Main engine has rubber hoses draining oil to the bilge. Remove hoses. LEGACY COMPONENT DESC: Hose
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 17 October 2002
Resolved 11 October 2002
Resolution: Deficiency cleared by LR class report.
Documentation
Issued 27 June 2000 Resolved
INTERNATIONAL TONNAGE CERTIFICATE INVALID. (TONNAGE CONVENTION, ARTICLE 7) CLASS OR FLAG STATE TO ISSUE NEW TONNAGE CERTIFICATE BY NEXT U.S. PORT OR NO LATER THAN 27JUL00.
Condition: Unknown
Due 27 July 2000
Resolved 10 October 2002
Resolution: Tonnage Certificate valid per NEWMS PSC boarding 10 Oct 02.
Engineering
Issued 27 June 2000 Resolved
REPLACE PIPING ON INTAKE FOR FRESH WATER GENERATOR (SOLAS 74 REG 1/11). CLASS TO VERIFY REPAIR AND FAX REPORT TO U.S.C.G.
Condition: Unknown
Due 27 July 2000
Resolved 15 October 2002
Resolution: Verfied repair complete as per NEWMS PSC boarding 10 Oct 02.
Electrical
Issued 27 June 2000 Resolved
REPLACE FRESH WATER COOLANT SEAL ON #2 CYLINDER OF #3 GENERATOR (SOLAS 74 REG. 1/11). CLASS TO VERIFY REPAIRS AND FAX REPORT TO U.S.C.G.
Condition: Unknown
Due 27 July 2000
Resolved 15 October 2002
Resolution: Repair complete and verified as per NEWMS PSC boarding 10 Oct 02.
Navigation
Issued 27 June 2000 Resolved
IMO APPROVAL PLACARD FOR ARPA MISSING. (33 CFR 164.38 (d)(1)(ii). GET PLACARD FROM MANUFACTURER OF ARPA BY NEXT U.S. PORT, OR NO LATER THAN 27JUL00.
Condition: Unknown
Due 27 July 2000
Resolved 15 October 2002
Resolution: Placard replaced.
Navigation
Issued 27 June 2000 Resolved
ECHO DEPTH SOUNDER RECORDING DEVICE INOP. (33 CFR 134.35(i)). REPAIR AND FAX TECHNICIANS REPORT TO U.S.C.G. BY NEXT U.S. PORT, OR NO LATER THAN 27JUL00
Condition: Unknown
Due 27 July 2000
Resolved 15 October 2002
Resolution: Echo depth sounder working correctly during NEWMS PSC boarding 10 Oct 02.
Navigation
Issued 17 September 1998 Resolved
MISSING MANEUVERING FACT SHEET WARNING STATEMENT.
Condition: Unknown
Due 17 September 1998
Resolved 21 September 1998
Electrical
Issued 17 September 1998 Resolved
HINGES ON ELECTRICAL COVER FOR DUMBWAITER IN GALLEY ARE BROKEN. COVER IS HELD ON BY BAILING WIRE.
Condition: Unknown
Due 17 September 1998
Resolved 21 September 1998
Electrical
Issued 17 September 1998 Resolved
ELECTRICAL SWITCH IN INTERNATIONAL SHORE CONNECTION ROOM IS NOT FUNCTIONINGPROPERLY. (SOLAS 74 AMENDED REG 11-1/45.1)
Condition: Unknown
Due 17 September 1998
Resolved 21 September 1998
Navigation
Issued 17 September 1998 Resolved
MISSING CHART NUMBER 14839 FOR LOCAL HARBOR.
Condition: Unknown
Due 17 September 1998
Resolved 21 September 1998
Navigation
Issued 17 September 1998 Resolved
LIGHT LIST VOL VII NOT CURRENTLY CORRECTED. THE CREW DID NOT PROPERLY KNOWHOW TO UTILIZE CORRECTIONS PROVIDED BY SUPPLIER.
Condition: Unknown
Due 17 September 1998
Resolved 21 September 1998
Navigation
Issued 17 September 1998 Resolved
COAST PILOT, 28TH EDITION, WAS NOT CURRENTLY CORRECTED. THE CREW WAS UNABLETO USE CORRECTIONS PROVIDED BY SUPPLIER.
Condition: Unknown
Due 17 September 1998
Resolved 21 September 1998
Engineering
Issued 17 September 1998 Resolved
MISSING REQUIRED OIL DISCHARGE PLACARD AT OILY WATER SEPERATOR STATION.
Condition: Unknown
Due 17 September 1998
Resolved 21 September 1998
Fire Fighting
Issued 17 September 1998 Resolved
INTERNATIONAL SHORE CONNECTION MISSING REQUIRED GASKET. (SOLAS 74 AMENDED REG 11-2/19)
Condition: Unknown
Due 17 September 1998
Resolved 21 September 1998
Lifesaving
Issued 17 September 1998 Resolved
LIFERAFTS ON THE PORT AND STARBOARD SIDE OF THE VESSEL NOT PROPERLY STOWED IN BRACKETS OR SECURED WITH PROPER RELEASINGE EQUIPMENT. (SOLAS 74 AMENDED REG 111/29)_x001C_
Condition: Unknown
Due 17 September 1998
Resolved 21 September 1998
Electrical
Issued 17 September 1998 Resolved
MISSING NON-CONDUCTIVE MATTING IN CONTROL ROOM FLOOR. (SOLAS 74 AMENDED REG11-1/45.1)
Condition: Unknown
Due 19 September 1998
Resolved 21 September 1998
Lifesaving
Issued 17 September 1998 Resolved
LADDER TREADS THROUGHOUT THE SHIP RUSTED AND UNABLE TO SUPPORT A CREWMAN UTILIZING THE TREADS. (ILLC 66 ANNEX 1/25.
Condition: Unknown
Due 18 October 1998
Resolved 10 October 2002
Resolution: Ladders repaired/replaced.
Deck/Cargo
Issued 4 August 1997 Resolved
OIL CONTAINMENT STARBOARD HAS WASTED BOTTOM.
Condition: Unknown
Due 19 August 1997
Resolved 19 August 1997
Lifesaving
Issued 14 April 1997 Resolved
SOLAS III/19.2: FRACTURE ON NO. 1 L/B, STBD SIDE AFT ON KEEL NEAR PROPELLER BOSS. CLASS TO ADDRESS AND RECOMMEND REPAIRS AT NEXT ANNUAL SURVEY BUT NOT LATER THAN 11AUG97.
Condition: Unknown
Due 5 August 1997
Resolved 5 August 1997
Lifesaving
Issued 1 July 1996 Resolved
A VIO OF SOLAS IN THAT THE STARBOARD LIFEBOAT RUDDER DID NOT OPPERATE DURING THE LIFEBOAT DRILL. DUE TO THE LACK OF PMS._x001C_ _x001C_ CORRECT PRIOR TO DEPARTURE.
Condition: Unknown
Due 2 July 1996
Resolved 3 July 1996
Accommodation/Occupational Safety
Issued 17 December 1994 Resolved
REPLACE ALL MISSING HARDWARE ON ALL STAIRWELL DOORS PRIOR TO DEPARTURE FROMPORT OF NEW ORLEANS. SOLAS CHAP. II-2, REG. 46
Condition: Unknown
Due 17 December 1994
Resolved 17 December 1994
Navigation
Issued 17 December 1994 Resolved
PROVIDE NAVIGATION CHART #11370 PRIOR TO DEPARTUREFROM PILOT TOWN ANCHORAGE. CHART NOT ON BOARD AND IS NEEDED TO TRANSIT AREA ABOVE NEW ORLEANS. 33 CFR 164.33
Condition: Unknown
Due 17 December 1994
Resolved 17 December 1994

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.