07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 12 March 2025
Resolved
Vessels described by 46 CFR 175.110(c) (vessels operating on a coast wise route) must have an interconnected fire detection system in compliance with § 181.450 installed in all enclosed areas where passengers and crew have routine access, including accommodation spaces and machinery spaces. Marine inspector observed no interconnected smoke detector within machinery space. Vessel shall install a UL 217 approved interconnected smoke detector within the machinery space.
46 CFR 181.405 (c)
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 7 April 2025
Resolution: MI observed interconnected fire detection installed, tested, all sat.
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Other (Conditions of employment)
Issued 12 March 2025
Resolved
The alcohol testing devices need not be carried on board each vessel if obtaining the devices and conducting the required alcohol tests can be accomplished within 2 hours from the time of occurrence of the SMI. Marine Inspector observed vessel missing alcohol swabs on board. Vessel shall placed alcohol swabs on the vessel.
46 CFR 4.06-15(a)(3)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 7 April 2025
Resolution: placed new swabs on board, all sat.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 12 March 2025
Resolved
As appropriate for the intended voyage, a vessel must carry adequate and up-to-date: Charts of large enough scale to make safe navigation possible. Marine Inspector observed paper chart of operating area not up-to-date.
46 CFR 4.06-15
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 7 April 2025
Resolution: new chart procured and placed on board. all sat.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 12 March 2025
Resolved
Protect passengers, crew, other persons, and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment, and electrical shock. Marine inspector observed exposed wires from generator to breaker box and surrounding equipment, to include electrical connections with wingnuts. Vessel shall ensure no exposed wires and electrical hazards are removed.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 7 April 2025
Resolution: vessel operator ensured electrical hazards were rectified within engine room and aboard vessel. all sat.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 12 March 2025
Resolved
Electrical equipment used in the following locations must be dripproof: A machinery space. Marine inspector observed electrical outlets that were not drip-proof. Vessel shall replace all exposed outlets within machinery space.
46 CFR 183.210(a)
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 7 April 2025
Resolution: operator installed new receptacle outlets with drip proof shields.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 12 March 2025
Resolved
A generator or motor designed for 40 °C (104 °F) may be used in 50 °C (122 °F) ambient locations provided the generator or motor is derated to 80 percent of the full load rating, and the rating or setting of the overcurrent devices is reduced accordingly. Vessel shall
derate their generator.
46 CFR 183.320 (b)(2)
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 7 April 2025
Resolution: vessel installed new 30 amp breakers. all sat.
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 12 March 2025
Resolved
The intent of a radio installation is to establish communications during emergencies. The vessel’s route allows the vessel to go out up to 100 NMs from shore. The vessels SSB radio is not equipped with a DSC alert; therefore, the vessel is unable to contact anyone during emergencies as the CG and vessels with GMDSS only rely on the SSB DSC to hear distress calls. Replace vessels SSB with a model containing DSC capability. In addition, the vessel does not have a reserve power supply. Install appropriate reserve power supply or as an acceptable alternative, provide a VHF FM handheld radio with appropriate charger. The FCC issuing authority for the Radiotelephony Certificate utilized an outdated “How to Conduct an Inspection of a Small Passenger Vessel” checklist. Provide new Radiotelephony Certificate using the updated checklist, revision 2021.02.24.
46 CFR 184.502
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 7 April 2025
Resolution: vessel installed new vhf handheld radio, with mmsi programmed and lat/long installed. all sat.
01 - Certificates & Documentation › 013 - Documents › Stability Information Booklet
Issued 12 March 2025
Resolved
The stability letter must be posted under glass or other suitable transparent material, such that all pages are visible, at the operating station of the vessel.
46 CFR 176.306
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 7 April 2025
Resolution: vessel operator installed stability letter at operating station. all sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 12 March 2025
Resolved
A vessel must be equipped with bilge pumps that meet UL 1113 requirements. Replace bilge pumps to meet standard.
46 CFR 182. 520 (e)(1)
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 7 April 2025
Resolution: vessel installed new rule pumps iaw with listed citation. all sat.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 12 March 2025
Resolved
At each inspection for certification and at every other
vessel inspection all observed unsafe practices. Marine
inspector observed crack near ladder well to pilot
house.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 7 April 2025
Resolution: vessel repaired crack neart ladderwell to pilothouse. all sat.
09 - Working and Living Conditions › 092 - Working Conditions › Fitness for duty - intoxication
Issued 30 November 2022
Resolved
The marine employer must have a sufficient number of alcohol testing devices readily accessible on board the vessel to determine the presence of alcohol in the system of each individual who was directly involved in the SMI. Vessel has expired alcohol testing devices on board. Vessel is restricted to voyages that allow alcohol tests to be accomplished within two hours of a serious marine incident.
46 CFR 4.06-15(a)(1)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 2 December 2022
Resolution: got new alcohol testing devices on board
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 30 November 2022
Resolved
Each life jacket must be marked with Type I retroreflective material approved in 46 CFR 164.018 or other standard specified by the Commandant. 01 children’s lifejacket had deteriorated retroreflective tape. Vessel is restricted to carrying 02 children until corrected.
46 CFR 185.604(h)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 2 December 2022
Resolution: replaced retroreflective tape
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 30 November 2022
Resolved
Each child size life jacket must be stowed in a location that is appropriately marked and separated from adult life jackets so the child size life jackets are not mistaken for adult life jackets. Vessel missing clear separation between child and adult lifejackets.
46 CFR 180.78(a)(5)
Condition: Design Flaw
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 December 2022
Resolved 2 December 2022
Resolution: added separation
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 30 November 2022
Resolved
Fuel lines must be annealed tubing of copper, nickel-copper, or copper-nickel having a minimum wall thickness of 0.9 millimeters (0.035 inch) except that:(i) Diesel fuel piping of other materials, such as seamless steel pipe or tubing, which provide equivalent safety may be used;(ii) Diesel fuel piping of aluminum is acceptable on aluminum hull vessels provided it is a minimum of Schedule 80 wall thickness; and(iii) when used, flexible hose must meet the requirements of § 182.720(e). 02 hoses on generator could not be verified as approved type. Provide evidence of proper replacement or evidence of approved hoses.
46 CFR 182.455
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 December 2022
Resolved 2 December 2022
Resolution: replaced flex hose
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 30 November 2022
Resolved
At each inspection for certification and at every other vessel inspection all observed unsafe practices, fire hazards, and other hazardous situations must be corrected and all required guards and protective devices must be in satisfactory condition. Electrical connections on aft bulkhead of engine room need to be enclosed.
46 CFR 176.830(a)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 December 2022
Resolved 4 December 2022
Resolution: enclosed electrical connections
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 30 November 2022
Resolved
At each inspection for certification and at every other vessel inspection the bilges and other spaces may be examined to see that there is no excessive accumulation of oil, trash, debris, or other matter that might create a fire hazard, clog bilge pumping systems, or block emergency escapes. Vessel had excess flammable liquids stored in accommodation space on board. Remove excess flammable liquids or store in designated flammable storage locker.
46 CFR 176.830(b)
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 December 2022
Resolved 2 December 2022
Resolution: put in designated flammable storage locker
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 30 November 2022
Resolved
At each inspection for certification and at every other vessel inspection all observed unsafe practices, fire hazards, and other hazardous situations must be corrected and all required guards and protective devices must be in satisfactory condition. Handrail fasteners were loose throughout vessel.
46 CFR 176.830(a)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 December 2022
Resolved 2 December 2022
Resolution: replaced fasteners
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 30 November 2022
Resolved
The operator of each self-propelled vessel 12 meters or more in length shall carry, on board and maintain for ready reference, a copy of these Rules. Vessel was missing current Inland Navigation Rules.
33 CFR 83.01(g)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 December 2022
Resolved 2 December 2022
Resolution: downloaded copy
01 - Certificates & Documentation › 011 - Ships Certificates › USCG Certificate of Documentation (COD)
Issued 30 November 2022
Resolved
The person in command of a documented vessel must have on board that vessel the original Certificate of Documentation (COD) currently in effect for that vessel. Vessel was missing valid COD on board.
46 CFR 67.313(a)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 December 2022
Resolved 2 December 2022
Resolution: placed on board
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 3 February 2022
Resolved
All vessels must have navigation lights that are in compliance with the applicable sections of the international and inland navigation rules. STBD running light was oriented downward, not displaying correct light pattern. Repair or replace STBD navigation light.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 3 February 2022
Resolved 3 February 2022
Resolution: Operator provided evidence of repair of navigation light.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 3 February 2022
Resolved
Electrical equipment used in machinery spaces must be drip-proof. Electrical outlet in engine room found not drip-proof. Install/ fabricate drip-proof protection for outlet.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 3 February 2022
Resolved 3 February 2022
Resolution: Owner provided evidence of new outlet installation.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 3 February 2022
Resolved
The Certificate of Inspection must be posted under glass or other suitable transparent material, such that all pages are visible, in a conspicuous place on the vessel where observation by passengers is likely. COI and stability letter were found not posted. Post COI and stability letter.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 3 February 2022
Resolved 3 February 2022
Resolution: Owner provided evidence of proper posting of COI and stability letter.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 3 February 2022
Resolved
Vessels on an exposed or partially protected route must be fitted with an 8 inch coaming on an opening that gives access to or is located in a cockpit or well, or an exposed location on a flush deck vessel. The aft door onboard was found without a sufficient coaming. Repair or replace coaming on door, prior to or during the next scheduled dry dock period.
46 CFR 171.124 (OLD)
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 31 December 2023
Resolved 31 October 2023
Resolution: Vessel is required to have 6" lip around door. Vessels door is stepped up and the measurement to the scupper is 6"
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 17 November 2021
Resolved
Replace worn cutlass bearings on both shafts.
Action required: 705 - Other - as specified
Due 17 November 2021
Resolved 13 December 2021
Resolution: Replaced.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 17 November 2021
Resolved
Repair cracked Starboard shaft.
Action required: 705 - Other - as specified
Resolved 13 December 2021
Resolution: Repaired.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 17 November 2021
Resolved
Repair and install both propellers.
Action required: 705 - Other - as specified
Resolved 13 December 2021
Resolution: Repaired and installed.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 17 November 2021
Resolved
Repair 2 blisters in FRP on Port Bow.
Action required: 705 - Other - as specified
Resolved 13 December 2021
Resolution: Repaired.
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Other (Conditions of employment)
Issued 17 February 2021
Resolved
Vessel is required to have an alcohol test kit. The test kit onboard was expired. Provide a valid alcohol test kit.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 March 2021
Resolved 3 March 2021
Resolution: New alcohol test strips were provided that expire in January 2022.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 17 February 2021
Resolved
Vessel is required to have a 24", orange ring buoy with a waterlight and tending line. The ring buoy on board has faded in color, the continuous line around it was weathered and fraying, and the waterlight line is frayed and weathered. Replace or repair the ring buoy, and replace the lines on the ring buoy and waterlight.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 February 2021
Resolved 3 March 2021
Resolution: Vessel owner provided a new ring buoy with a new line, and replaced the waterlight line. All were found to be in compliance with the regulations.
02 - Structural Conditions › N/A - No Subsystem › Marking of IMO number
Issued 17 February 2021
Resolved
Vessel is required to be marked with name and homeport on the stern, and vessel name on the port and starboard bow. No markings were on the vessel. Place the required markings on the vessel.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 March 2021
Resolved 19 March 2021
Resolution: Recieved pictures, all sat
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 19 June 2019
Resolved
Generator designed for 40 degrees Celsius must be de-rated to 80% of the full load rating. De-rate generate to 80% of the full load rating.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 July 2019
Resolved 23 August 2019
Resolution: Replaced fuse with 25amp breaker vice 40 amp.
14 - Pollution Prevention › 144 - MARPOL Annex IV (Not Applicable to PSC Exams conducted in the U.S.) › Sewage discharge connection
Issued 19 June 2019
Resolved
MSD valve on Type 3 tank must be secured. Secure valve by removing handle, padlocking, or wire tie.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 20 June 2019
Resolution: Locked out valve to prevent opening.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 19 June 2019
Resolved
High water alarm must have audible and visual indicator at operating station. Provide working alarm for high water alarm in lazarette.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 20 June 2019
Resolution: Provided working high water alarm.
Operations/Management › Drug and Alcohol Testing › Recordkeeping
Issued 4 April 2017
Resolved
Provide supervisory training documentation for all crew with supervisory duties. 46 CFR 16.401
Condition: Invalid
Action required: 705 - Other - as specified
Due 4 May 2017
Resolved 3 May 2017
Resolution: Provided proof of training.
Operations/Management › Drug and Alcohol Testing › EAP Display Requirements
Issued 4 April 2017
Resolved
Display EAP resources in location visible to crew. 46 CFR 16.401
Condition: Invalid
Action required: 705 - Other - as specified
Due 4 May 2017
Resolved 3 May 2017
Resolution: Displayed EAP resources.
Operations/Management › Drug and Alcohol Testing › Recordkeeping
Issued 4 April 2017
Resolved
Provide background checks for employees as required per 49 CFR 40
Condition: Invalid
Action required: 705 - Other - as specified
Due 4 May 2017
Resolved 3 May 2017
Resolution: Proof of background checks provided.
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 14 June 2016
Resolved
Unable to produce COD. Provide COD
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 June 2016
Resolution: Original copy of COD produced.
Lifesaving › Lifejacket/PFD (Type I) › Quantity
Issued 14 June 2016
Resolved
Insufficient number of life jackets reduce passengers on board to 21 until fixed. Lights inoperable limit to day light operation
Condition: Invalid
Action required: 705 - Other - as specified
Due 30 June 2016
Resolved 16 June 2016
Resolution: Produced sufficient number of life jackets specified on COI.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 14 June 2016
Resolved
Waterlight on life ring buoy is inoperable vessel is limited to day light operation
Condition: Invalid
Action required: 705 - Other - as specified
Due 30 June 2016
Resolved 29 July 2016
Resolution: Waterlight was made operable.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 14 June 2016
Resolved
Side light on STBD side inoperable the vessel is limited to daylight operation. Repair side light
Condition: Invalid
Action required: 705 - Other - as specified
Due 30 June 2016
Resolved 29 July 2016
Resolution: Side light was made operable.
Accommodation/Occupational Safety › Occupational Safety › Storm Rail
Issued 14 June 2016
Resolved
Provide line on chain at top of ladder
Action required: 705 - Other - as specified
Due 30 June 2016
Resolved 29 July 2016
Resolution: Chain was provided at top of ladder.
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 14 June 2016
Resolved
Provide roster of all crew members on drug and alcohol program
Condition: Invalid
Action required: 705 - Other - as specified
Due 30 June 2016
Resolved 29 July 2016
Resolution: Provided roster of all crew members.
Communications › Alarms/Indicators › Bilge Alarm
Issued 14 June 2016
Resolved
Bilge light indication in laz inoperable make operable for high water alarm
Condition: Invalid
Action required: 705 - Other - as specified
Due 30 June 2016
Resolved 29 July 2016
Resolution: Bilge indication light was made operable.
Documentation › Certificates/Documents › FCC SSL
Issued 14 June 2016
Resolved
Unable to produce marine radio operator permit. Provide permit
Condition: Invalid
Action required: 705 - Other - as specified
Due 30 June 2016
Resolved 29 July 2016
Resolution: Provided marine radio operator permit.
Navigation › Piloting/Steering › US Coast Pilot
Issued 14 June 2016
Resolved
Update coast pilot, light list, tide and currents
Action required: 705 - Other - as specified
Due 30 June 2016
Resolved 14 September 2016
Resolution: Provided updated copies of all required pubs.
Fire Fighting › Means of Escape › Doorways
Issued 14 June 2016
Resolved
Emergency exit inoperable repair/replace
Action required: 705 - Other - as specified
Due 30 June 2016
Resolved 29 July 2016
Resolution: Emergency exit was made operable.
Fire Fighting › Fixed Fire Detection System › UL 217 Approval
Issued 14 June 2016
Resolved
Smoke detectors not the approved type. Provide approved type
Condition: Invalid
Action required: 705 - Other - as specified
Due 30 June 2016
Resolved 29 July 2016
Resolution: Provided approved type smoke detectors.
Deck/Cargo › Vapor Control Systems › Piping/Hoses
Issued 14 June 2016
Resolved
Make ENG room forward bulkhead vapor tight
Condition: Invalid
Action required: 705 - Other - as specified
Due 30 June 2016
Resolved 29 July 2016
Resolution: ENG room forward bulkhead was made vapor tight.
Operations/Management › Drug and Alcohol Testing › EAP Training Requirements
Issued 14 June 2016
Resolved
Supervisory training needed for master
Condition: Invalid
Action required: 705 - Other - as specified
Due 30 June 2016
Resolved 14 September 2016
Resolution: Provided documention of required training.