MAURY USCG vessel records
← All vessels

SEA ROCKET

Built
1987
Last inspected
14 May 2026
Documentation
Valid · NVDC file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 14 May 2026
…with no type recorded1
Operational controls None recorded without a removal date
Years with a record 11 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDL4526
282011
Flag
UNITED STATES
Maury page id
psix-282011

Documentation record

Registered dimensions (L × B × D)64.9 ft × 19.0 ft × 10.0 ft
Registered tonnagegross 82 / net 66
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderBONER YACHT SALES INC · ELMORE, AL, UNITED STATES · built 1987
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portOCEAN CITY, MD
Endorsements, as the file codes themcw_un
DocumentationValid · issued 29 January 2026 · expires 28 February 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it66 - Simplified, Net Ton
82 - Simplified, Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
The full record for this vessel

Behind this panel: 20 inspections, each with its date, unit and type; 70 deficiencies with the resolution recorded against each, 3 without one; operational controls, none recorded without a removal date; no tow-unit appearances recorded; no other recorded names; the documentation record: dimensions, tonnage, builder, hailing port and endorsements. Every line is a record the Coast Guard wrote; the counts above are the same counts as in the summary, and they are free.

Professional is $39 a month or $299 a year, or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks every detail section on every vessel page, fleet watch tied to your account, and ownership records on request. Already a subscriber? Sign in.

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 20

14 May 2026 Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 8384660
16 April 2026 Drydock Exam · Internal Structural Exam
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 8352642
15 May 2025 Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 8139168
6 May 2024 Administrative Inspection · Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7907256
15 April 2024 Drydock Exam · Internal Structural Exam
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7895744
28 September 2023 Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7803455
1 June 2023 Annual Inspection · Administrative Inspection · In-Service Inspection · Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7688964
3 May 2022 Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 7442941
10 February 2022 Deficiency Check · COI Inspection · Administrative Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7394372
18 June 2021 Annual Inspection · In-Service Inspection · Deficiency Check · Administrative Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7229160
18 June 2021 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7238448
17 August 2020 Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7041932
1 July 2020 Drydock Exam
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7008917
23 August 2019 Annual Inspection · DAPI Audit
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6812955
18 June 2018 DAPI Audit · Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6456828
27 April 2018 Internal Structural Exam · Drydock Exam
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6449581
11 September 2017 Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6264457
25 May 2017 COI Inspection · DAPI Audit
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6134407
26 April 2017 DAPI Audit
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6136145
18 April 2016 Drydock Exam · Internal Structural Exam · Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 5988931

Deficiency record · 70

11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 14 May 2026 Resolved
Oceans, coastwise, limited coastwise, and Great Lakes routes. A vessel on an oceans, coastwise, limited coastwise, or Great Lakes route must carry— (1) Six hand red flare distress signals approved in accordance with § 160.021 in subchapter Q of this chapter, or other standard specified by the Commandant, including, but not limited to, approval series 160.121; and (2) Six hand orange smoke distress signals approved in accordance with § 160.037 in subchapter Q of this chapter, or other standard specified by the Commandant. Vessel missing 6 flares. 46CFR180.68(a)
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 15 May 2026
Resolution: Vessel has newly added flares.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 14 May 2026 Resolved
On a vessel of at least 7.9 meters (26 feet) in length, a visual and audible alarm must be provided at the operating station to indicate a high water level in each of the following normally unmanned spaces: (1) A space with a through-hull fitting below the deepest load waterline, such as a lazarette; (2) A machinery space bilge, bilge well, shaft alley bilge, or other spaces subject to flooding from sea water piping within the space. Aft compartment high level bilge alarm is inop. 46CFR182.530(a)
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 15 May 2026
Resolution: Vessel operator provided proof of working Bilge High Level Alarm
04 - Emergency Systems › N/A - No Subsystem › Man Overboard Drill (MOB)
Issued 14 May 2026 Resolved
46 CFR 185.520(f) Abandon ship and man overboard drills and training shall be logged or otherwise documented for review by the Coast Guard upon request. - Vessel had no logs of drills or EPIRB testing. Provide documentation of drills and testing.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 15 May 2026
Resolution: Verified drill logs were established and current.
04 - Emergency Systems › N/A - No Subsystem › Man Overboard Drill (MOB)
Issued 15 May 2025 Resolved
46 CFR 185.520(f) Abandon ship and man overboard drills and training shall be logged or otherwise documented for review by the Coast Guard upon request. - Vessel had no logs of drills or EPIRB testing. Provide documentation of drills and testing.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 15 May 2025
Resolution: Received photo of drill log
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 15 May 2025 Resolved
46 CFR 180.70(d)(3) Each floating waterlight installed after March 11, 1997, on a vessel carrying only one ring buoy, must be attached to the lanyard with a corrosion resistant clip. - Vessel needs corrosion resistant clip and vessel name written on its life buoy.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 17 May 2025
Resolution: Received photo of corrected life bouy.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 15 May 2025 No resolution recorded
46 CFR 184.710 Each first-aid kit must meet the requirements in ISO 18813:2006(e) Paragraph 4.12. - Vessel had expired contents in first aid kit.
Action required: 50 - Rectify deficiencies w/in 30 days
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 15 May 2025 No resolution recorded
46 CFR 183.340(b)(4) All cable and wires must be installed with metal supports spaced not more than 24 inches apart, and in such a manner to avoid chafing and other damage. - Multiple cables where in bilges of spaces and not properly supported.
Action required: 50 - Rectify deficiencies w/in 30 days
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 15 May 2025 Resolved
46 CFR 177.900 Deck rails must be designed and constructed to withstand a point load of 200lbs applied at any point in any direction. - Vessel stbd hand rail in way of operating station was loose at the gunnel.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 17 May 2025
Resolution: Received photo of corrected hand rail
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 15 May 2025 No resolution recorded
46 CFR 177.820(b) A seat must be constructed to minimize the possibility of injury and avoid trapping occupants. - 03 passenger seats were identified broken. Replace as original.
Action required: 50 - Rectify deficiencies w/in 30 days
01 - Certificates & Documentation › 011 - Ships Certificates › USCG Certificate of Documentation (COD)
Issued 6 May 2024 Resolved
Any vessel of at least five net tons wholly owned by a citizen or citizens of the United States is eligible for documentation under this part. This includes, but is not limited to, vessels used exclusively for recreational purposes and vessels used in foreign trade. Vessel's COD is not current. 46CFR67.5
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 June 2024
Resolved 23 May 2024
Resolution: Vessel operator provided proof of current COD
05 - Radio Communications › N/A - No Subsystem › Maintenance/duplication of equipment
Issued 6 May 2024 Resolved
Every vessel subject to Part III of Title III of the Communications Act must have a detailed inspection of the radio installation by an FCC-licensed technician in accordance with § 80.59 once every five years. The FCC-licensed technician must use the latest FCC Information Bulletin, How to Conduct an Inspection of a Small Passenger Vessel. If the ship passes the inspection, the technician will issue a Communications Act Safety Radiotelephony Certificate. The vessel's safety cert had the wrong call sign. 46CFR80.903
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 June 2024
Resolved 23 May 2024
Resolution: Vessel operator provided an updated FCC Safety Radio Certificate with proper Call Sign
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 6 May 2024 Resolved
Oceans, coastwise, limited coastwise, and Great Lakes routes. A vessel on an oceans, coastwise, limited coastwise, or Great Lakes route must carry— (1) Six hand red flare distress signals approved in accordance with § 160.021 in subchapter Q of this chapter, or other standard specified by the Commandant, including, but not limited to, approval series 160.121; and (2) Six hand orange smoke distress signals approved in accordance with § 160.037 in subchapter Q of this chapter, or other standard specified by the Commandant. Vessel missing 9 flares. 46CFR180.68(a)
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 23 May 2024
Resolution: Vessel provided proof of upddated Flares.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 6 May 2024 Resolved
A bilge pipe in a vessel of not more than 19.8 meters (65 feet) in length must be not less than 25 millimeters (1 inch) nominal pipe size. A bilge pipe in a vessel of more than 19.8 meters (65 feet) in length must be not less than 40 millimeters (1.5 inches) nominal pipe size. A bilge suction must be fitted with a suitable strainer having an open area not less than three times the area of the bilge pipe. Vessel had no strainers at any of the bilge suction locations. 46CFR182.510(b)
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 30 May 2024
Resolution: Verified strainers were installed on bilge piping
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 6 May 2024 Resolved
On a vessel of at least 7.9 meters (26 feet) in length, a visual and audible alarm must be provided at the operating station to indicate a high water level in each of the following normally unmanned spaces: (1) A space with a through-hull fitting below the deepest load waterline, such as a lazarette; (2) A machinery space bilge, bilge well, shaft alley bilge, or other spaces subject to flooding from sea water piping within the space. Aft compartment high level bilge alarm is inop. 46CFR182.530(a)
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 23 May 2024
Resolution: Vessel operator provided proof of working Bilge High Level Alarm
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 18 July 2023 Resolved
Each hatch exposed to the weather must be watertight. The hatches for the port and stbd void space are not sealing watertight and require repair.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 28 September 2023
Resolution: New hatches were installed on void spaces
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 6 June 2023 Resolved
Each hatch exposed to the weather must be watertight. The hatches for the cumming space and lazarette are not sealing watertight and require repair.
Action required: 701 - Prior to carriage of passengers/cargo
Due 6 June 2023
Resolved 6 June 2023
Resolution: Later in the afternoon, vessel rep provided videos to Sector Maryland-NCR that appeared to show the hatches in question operating properly.
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Other (Conditions of employment)
Issued 6 June 2023 Resolved
No marine employer shall engage or employ any individual as a crewmember unless the individual passes a chemical test for dangerous drugs for that employer. The current regular captain that the owner has employed on the vessel, listed as MID # 124782 on the Confirmation of Enrollment from the Maritime Consortium, Inc. dated 15 May 2023 that was presented to the attending Marine Inspectors upon request of confirmation of compliance with the DAPI requirements, is listed as “HOLD – No Proof” under the “Status of Enrollment” column. *must be corrected prior to this individual serving onboard the vessel to meet the COI minimum manning requirements*
Action required: 705 - Other - as specified
Due 6 June 2023
Resolved 18 July 2023
Resolution: Consortium has been updated to reflect current operating captain.
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 6 June 2023 Resolved
The owner, master, or managing operator shall instruct each crewmember, upon first being employed and prior to getting underway on a particular vessel, and at least once every 3 months, as to the duties that the crew member is expected to perform in an emergency. Crew training shall be logged or otherwise documented for review by the Coast Guard upon request. Abandon ship and man overboard drills and training shall be logged or otherwise documented for review by the Coast Guard upon request. Fire fighting drills and training shall be logged or otherwise documented for review by the Coast Guard upon request. Attending Coast Guard Marine Inspectors requested to review training and drill records, but no records could be provided for fire, abandon ship, and man overboard drills.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 June 2023
Resolved 18 July 2023
Resolution: o/o provided drill log from previous years.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 6 June 2023 Resolved
The bilge suctions shall be fitted with suitable strainers having an open area not less than three times the area of the bilge pipe. The bilge pick-up in the lazarette is missing the strainer.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 June 2023
Resolved 18 July 2023
Resolution: O/O installed bilge strainer
05 - Radio Communications › N/A - No Subsystem › Main installation
Issued 6 June 2023 Resolved
A vessel must comply with the applicable requirements for any radio installations as set forth in 47 CFR Part 80. Vessels operated solely within 20 nautical miles of land must be equipped with a VHF-DSC radiotelephone installation meeting the requirements of 80.1101 (c)(2). VHF-DSC radio is not properly programmed – missing MMSI number and GPS input.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 June 2023
Resolved 18 July 2023
Resolution: MMSI and GPS have been input into radio.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 6 June 2023 Resolved
Provision must be made for closing all supply duct cowls or scoops and exhaust duct discharge openings by a fixed gas extinguishing system. All closure devices must be readily available and mounted in the vicinity of the vent. The ventilation ducts for the machinery space that terminate near the port and starboard consoles are missing covers, which would allow the agent from the fire-extinguishing system to escape from the protected space, inhibiting the system’s effectiveness.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 June 2023
Resolved 18 July 2023
Resolution: Openings have been sealed.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 6 June 2023 Resolved
Each life jacket must be marked with Type I retroreflective material approved in 46 CFR 164.018. The retroreflective tape on 8 adult and 1 child lifejackets are no longer in serviceable condition.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 June 2023
Resolved 18 July 2023
Resolution: O/O installed retro on life jackets.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 6 June 2023 Resolved
Each child size life jacket must be stowed in a location that is appropriately marked and separated from adult life jackets so the child size life jackets are not mistaken for adult life jackets. The number and identification of the items stowed inside, and their sizes, must be marked in clearly legible letters and numbers on each container for life jackets. In the forward storage area, adult and child lifejackets were found intermixed and without clear labeling indicating how each type were stowed separate from each other.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 June 2023
Resolved 18 July 2023
Resolution: O/O fixed storage and labeling for child life jackets.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 6 June 2023 Resolved
Each ring buoy on a vessel must be approved in accordance with 160.060 in subchapter Q of this chapter. The ends of the grab line shall be securely and neatly spliced together. The grab line shall encircle the buoy and shall be held in place by the backets. Ring lifebuoy line wasted and broken and requires replacement.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 June 2023
Resolved 18 July 2023
Resolution: Ring Buoy line was replaced.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 6 June 2023 Resolved
At each initial and subsequent inspection, the owner or managing operator shall be prepared to conduct tests and have the vessel ready for inspection of its fire protection equipment, including: operation of the fire main system. At each inspection for certification and at every other vessel inspection all observed unsafe practices, fire hazards, and other hazardous situations must be corrected. At the time of inspection, observed a dripping leak on the fire main near the cross-connect between the fire main and bilge piping when the fire pump and main was tested.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 June 2023
Resolved 18 July 2023
Resolution: Leak was repaired.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 6 June 2023 Resolved
Each hatch cover must have securing devices and be attached to the hatch frame or coaming by hinges, captive chains, or other devices to prevent its loss. The hatches for the engine room and port/starboard void spaces (near fuel tank) are missing securing devices (engine room hatch missing pin, void spaces hatches missing captive chains).
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 June 2023
Resolved 18 July 2023
Resolution: Securing devices were installed.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 6 June 2023 Resolved
A vessel must carry either a first aid kit approved under approval series 164.041 or a kit with equivalent contents and instructions. The first aid kit available onboard at time of inspection was expired.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 June 2023
Resolved 18 July 2023
Resolution: First Aid kit was replaced.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 6 June 2023 Resolved
For a submersible electric bilge pump, a positive shutoff valve must be installed at the hull penetration. The overboard discharge pipe for the electric submersible bilge pump in the #2 void space is missing a shutoff valve.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 June 2023
Resolved 18 July 2023
Resolution: O/O installed shutoff valve at hull penetration.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 6 June 2023 Resolved
At each initial and subsequent inspection of a vessel, the owner or managing operator shall be prepared to conduct tests and have the vessel ready for inspections of the hull structure, including the following: inspection of all accessible parts of the exterior and interior of the hull. There are multiple instances of broken tabbing in the forepeak space. Provide a repair proposal to the Marine Inspector.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 June 2023
Resolved 18 July 2023
Resolution: Broken tabbing was repaired.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 6 June 2023 Resolved
Remote fuel shutoff stations shall be marked in clearly legible letters at least 1 inch high indicating purpose of the valve and direction of operation. The current marking for the fuel shutoff valves does not the above requirements.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 June 2023
Resolved 18 July 2023
Resolution: Fuel shutoff have been labeled.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 6 June 2023 Resolved
At each initial and subsequent inspection of a vessel, the owner or managing operator shall have the vessel ready for inspection of machinery, fuel, and piping systems, including the inspection of all machinery essential the routine operation of the vessel. Dripless shaft seals found to be leaking at time of attendance.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 June 2023
Resolved 18 July 2023
Resolution: Repairs have been made to the shaft seals.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 6 June 2023 Resolved
A propulsion engine control system, including pilothouse control, must be designed so that a loss of power to the control system does not result in an increase in shaft speed or propeller pitch. The vessel was recently repowered with electronically controlled engines. In accordance with CG-CVC Policy Letter 17-07, testing shall be conducted in accordance with the Marine Safety Center (MSC) accepted and reviewed testing protocol (e.g. QFA and DVTPs).
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 July 2023
Resolved 28 September 2023
Resolution: Verified DVTPs onboard worked as stated.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 6 June 2023 Resolved
Repairs or alterations to the hull, machinery, or equipment that affect the safety of the vessel must not be made without the approval of the cognizant OCMI. The owner or managing operator shall submit drawings, sketches, or written specifications describing the details of any proposed alterations to the cognizant [name withheld] alterations must be approved by the OCMI before work is started. The OCMI may require an inspection and testing whenever a repair or alteration is undertaken. The vessel’s DC electrical systems has reportedly been recently re-wired / re-done, without prior notification to the OCMI or submission of plans for the work to be performed. Submit electrical plans to the Marine Safety Center (MSC), with follow-up verification by attending CG Marine Inspector as needed.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 July 2023
Resolved 4 October 2023
Resolution: MIs attended vessel and completed DVTP checks.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 25 May 2022 Resolved
Each hatch exposed to the weather must be watertight. Watertight hatches throughout the weather deck are not closing watertight. 46CFR171.124(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 May 2022
Resolved 6 June 2023
Resolution: Hatches still an issue during the 2023 annual. For clarity and timelines for rectification moving forward, cleared this 835 and issued new 835s #1 and #11 in activity # 7688964.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 25 May 2022 Resolved
A visual indicator must be provided at the operating station to indicate when any automatic bilge pump is operating. The operating station has no visual indicators for installed automatic bilge pumps. 46CFR182.530(c)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 3 June 2022
Resolution: Indicator lights installed for automatic bilge pumps.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 25 May 2022 Resolved
Vessels carrying more than 49 passengers and =65ft in length shall be provided with 1 portable hand pump and 1 25GPM fixed power bilge pump which shall be self-priming and be permanently connected to the bilge main and may also be connected to the fire main. If of sufficient capacity the power bilge pump may also serve as a fire pump. A submersible electric bilge pump may be used as a power bilge pump only on a vessel of not more than 65 feet in length carrying not more than 49 passengers. Fixed power bilge pump and bilge main non-operational. 46CFR182.25-10(a)-(b) 46CFR182.520(e)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 May 2022
Resolved 16 April 2024
Resolution: Fixed bilge pump tested and operational. Satisfactory suction from forepeak, engine compartment, starboard void, and cummings void. Insufficient suction in steering compartment and port void.
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Other (Conditions of employment)
Issued 25 May 2022 Resolved
The marine employer must have a sufficient number of alcohol testing devices readily accessible on board the vessel to determine the presence of alcohol in the system of each individual who was directly involved in the SMI. No alcohol testing devices maintained on-board. 46 CFR 185.212 46 CFR 4.06-15(a)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 3 June 2022
Resolution: Vessel operates within 2hrs of testing facility. Tests strips on order for vessel.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 25 May 2022 Resolved
A power-driven fire pump shall be installed on each mechanically propelled "S" vessel which is permitted to carry more than 49 passengers. Fire pump inoperable. 46CFR181.10-1(a) Old 'T'
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 3 June 2022
Resolution: Fire pump and hose station statisfactorily tested.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 25 May 2022 Resolved
A vessel on which a pre-engineered fixed gas fire extinguishing system is installed must have the following equipment at the operating station:(1) A light to indicate discharge; (2) An audible alarm that sounds upon discharge. Audible alarm on pre-engineered fixed gas fire extinguishing system inoperable. 46CFR181.420(b)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 3 June 2022
Resolution: Pre-engineered fixed system alarm at operating station renewed and satisfactorily tested.
02 - Structural Conditions › N/A - No Subsystem › Ballast, fuel and other tanks
Issued 25 May 2022 Resolved
The discharge ends of vent pipes shall terminate on the hull exterior...or, they shall terminate in U-bends as high above the weather deck as practicable... The discharge ends of vent pipes shall be fitted with removable flame screens or flame arresters. Diesel fuel vent pipe on starboard side weather deck excessively wasted below u-bend and flame screen. 46CFR182.20-35(c)-(d) Old 'T'
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 May 2022
Resolved 6 June 2023
Resolution: Confirmed that flame screen was installed at time of 2023 annual inspection.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 25 May 2022 Resolved
Penetrations and openings in watertight bulkheads must have a means to make them watertight. Port exhaust piping penetration in the watertight bulkhead between port void and engine room cannot be made watertight. 46CFR171.114(a)(2)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 June 2022
Resolved 3 June 2022
Resolution: Port exhaust piping penetration between port void and engine compartment made watertight.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 25 May 2022 Resolved
A vessel must comply with the applicable requirements for any radio installations, including the requirements for a station license and installation certificates to be issued by Federal Communications Commission, as set for the in 47 CFR part 80. FCC Safety Radiotelephony Certificate expired and Master FCC Marine Radio Operator Permit not available for inspection. 46 CFR 184.502
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 June 2022
Resolved 3 June 2022
Resolution: FCC Safety Radiotelephony Certificate issued to expire 26MAY2027.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 25 May 2022 Resolved
Repairs or alterations that affect the safety of the vessel include, but are not limited to: replacement, repair, or refastening of deck or hull planking, plating, and structural members. Provide repair proposal for deck soft spot in way of passenger embarkation area and fueling hatch cover. 46 CFR 176.700(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 June 2022
Resolved 3 June 2022
Resolution: Decking reinforced in way of passenger embarkation area and fueling hatch cover
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 25 May 2022 Resolved
At each inspection for certification and at every other vessel inspection all observed unsafe practices, fire hazards, and other hazardous situations must be corrected and all required guards and protective devices must be in satisfactory condition. 26 passenger seats identified in need of repair and marked. 46CFR176.830
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 June 2022
Resolved 3 June 2022
Resolution: Passenger seating satisfactorily repaired.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 25 May 2022 Resolved
An adult life jacket must be provided for each person carried on board a vessel. 04 adult and 03 child life jackets observed in unserviceable condition and removed. Passengers reduced to 122 until life jackets replaced. 46CFR180.71(a)
Action required: 705 - Other - as specified
Resolved 3 June 2022
Resolution: 4 adult and 3 child life jackets renewed.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 3 May 2022 Resolved
Examine all accessible parts of the exterior and interior of the hull, the watertight bulkheads, and weather deck. So that the marine inspector may satisfy himself as to the construction of the hull structure. For the following submit a repair proposal to the satisfaction of the attending marine inspector IAW NVIC 7-95. Inspector noted the 2nd and 3rd frame in the first compartment from the port side were sistered together with deck screws and did not extend to the most forward bulkhead. 46 CFR 176.25-5
Condition: Improper Installation
Action required: 60 - Rectify deficiencies prior to movement
Resolved 3 June 2022
Resolution: Satisfactory repair work conducted.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 3 May 2022 Resolved
Examine all accessible parts of the exterior and interior of the hull, the watertight bulkheads, and weather deck. So that the marine inspector may satisfy himself as to the construction of the hull structure. For the following submit a repair proposal to the satisfaction of the attending marine inspector IAW NVIC 7-95. Inspector noted the deck frame forward of the 2nd compartment hatch is rotten and the deck on the port side of the hatch is also rotten. 46 CFR 176.25-5
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 3 June 2022
Resolution: Satisfactory repair work conducted.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Railing, gangway, walkway and means for safe passage
Issued 3 May 2022 Resolved
On passenger decks of vessels engaged in ferry or excursion operations, rails shall be at least 42 inches high. The space below the rail shall be fitted with bulwarks, chain link fencing, wire mesh, or the equivelant. For the following submit a repair proposal to the satisfaction of the attending marine inspector. Marine inspector noted missing course on railing. Replace missing bottom wire course on the vessel aft, port and starboard sides prior to conducting excursion operations. 46 CFR 177.35-1
Condition: Improper Installation
Action required: 60 - Rectify deficiencies prior to movement
Resolved 25 May 2022
Resolution: Observed no rail courses missing.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Railing, gangway, walkway and means for safe passage
Issued 3 May 2022 Resolved
Rails or equivalent protection shall be installed near the periphery of all weather decks accessible to passengers and crews. For the following submit a repair proposal to the satisfaction of the attending marine inspector. Marine inspector noted starboard railing had missing fasteners. 46 CFR 177.35-1
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 3 June 2022
Resolution: Railings fastened.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 19 June 2021 Resolved
In systems and applications where flexible hoses are permitted to be clamped, double hose clamping is required where practicable. Port engine cooling water intake is missing one hose clamp. 46 CFR 182.410(d)(1)
Action required: 701 - Prior to carriage of passengers/cargo
Due 19 June 2021
Resolved 23 June 2021
Resolution: Second hose clamp installed on port engine cooling water intake.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 19 June 2021 Resolved
A power-driven vessel underway shall exhibit a stern light. Stern navigation light is inoperable. 46 CFR 183.420 33 CFR 83.23(a)(i)
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 19 June 2021
Resolved 23 June 2021
Resolution: Stern light operational.
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Other (Conditions of employment)
Issued 19 June 2021 Resolved
The marine employer must have a sufficient number of alcohol testing devices readily accessible on board the vessel to determine the presence of alcohol in the system of each individual who was directly involved in the SMI. No alcohol testing devices maintained on-board vessel. 46 CFR 185.212 46 CFR 4.06-15(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 July 2021
Resolved 6 July 2021
Resolution: Vsl operator provided receipt for new alcohol testing strips placed onboard.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Railing, gangway, walkway and means for safe passage
Issued 19 June 2021 Resolved
Rails or equivalent protection shall be installed near the periphery of all weather decks accessible to passengers and crews. Starboard-bow deck rail fastener failure, reducing functionality of rail in passenger area. 46 CFR 177.35-1(a) Old 'T'
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 July 2021
Resolved 15 July 2021
Resolution: STBD bow railing properly repaired.
11 - Life Saving Appliances › N/A - No Subsystem › On board training and instructions
Issued 19 June 2021 Resolved
The master and crew of a vessel will be familiar with the content of and have mounted at the operating station, emergency instructions containing the actions to be taken in the event of fire, heavy weather, or man overboard conditions. Emergency instructions are not posted at the operating station or on board the vessel. 46 CFR 185.510(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 July 2021
Resolved 12 July 2021
Resolution: Emergency instructions posted onboard vessel.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 19 June 2021 Resolved
Each hatch exposed to the weather must be watertight. Engine room, port void space, and starboard void space hatch covers are not sealing water tight, and water is accumulating in starboard void bilge. 46 CFR 171.124(a) Old 'T'
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 July 2021
Resolved 15 July 2021
Resolution: Hatch covers renewed and now sealing properly.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 19 June 2021 Resolved
The installation and location of portable fire extinguishers must be to the satisfaction of the Officer in Charge, Marine Inspections. Two portable fire extinguishers loosely stored in forward-starboard compartment without installed mounting. 46 CFR 181.520
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 July 2021
Resolved 6 July 2021
Resolution: Vessel operator provided receipt for new extinguisher mounting brackets to be installed onboard.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 19 June 2021 Resolved
Each child size lifejacket must be stowed in a location that is appropriately marked and separated from adult life jackets so the child size lifejackets are not mistaken for adult life jackets. Child size life jackets are intermingled with adult size life jackets without markings for their stowed location, allowing sizes to be mistaken for each other. 46 CFR 180.78(a)(5)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 July 2021
Resolved 15 July 2021
Resolution: Child lifejackets have been properly segregated and stored away from adult-size lifejackets.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 19 June 2021 Resolved
A vessel must carry adequate and up-to-date charts, U.S. Coast Pilot [name withheld], and Tide & Current Tables for intended voyage. Chart plotter has not been updated since 2016 and no other navigational publications or charts are maintained on-board the vessel. 46 CFR 184.420(a)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 July 2021
Resolved 12 July 2021
Resolution: Chart plotter updated as of 04 July 2021 and up-to-date nautical publications for the areas navigated now carried onboard vessel.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 19 June 2021 Resolved
Each life jacket and ring life buoy must be marked in clearly legible block capital letters with the vessel's name. 8 life jackets and the ring life buoy were not adequately marked with vessel name. 46 CFR 185.604
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 19 June 2021
Resolved 19 June 2021
Resolution: Markings applied during inspection.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 18 June 2021 Resolved
Machinery and equipment installed on each vessel must be suitable for the vessel and its operation and for the purpose intended. All machinery and equipment must be installed and maintained in such a manner as to afford adequate protection from causing fire, explosion, machinery failure, and personnel injury. Vessel reported a casualty to their starboard engine. Cause of casualty is unknown at this time. Engine is currently inoperable. Vessel is not authorized to carry passengers until after repairs have been completed and sea trials are conducted in the presence of an attending Coast Guard Marine Inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Due 18 June 2021
Resolved 19 June 2021
Resolution: Cause of starboard engine casualty identified as wasted belt powering cooling pump. Belt was replaced new and satisfactory sea trials performed.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 23 August 2019 Resolved
Provide CG Approved First Aid kit.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 August 2019
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 23 August 2019 Resolved
Provide Nautical Publications required for vessel area of operation.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 August 2019
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 23 August 2019 Resolved
Properly mount/secure aft bilge pump float switch.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 August 2019
10 - Safety of Navigation › N/A - No Subsystem › Magnetic compass
Issued 23 August 2019 Resolved
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 August 2019
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 23 August 2019 Resolved
Numerous scuttles found unable to secure closed due to seized t-handles. Repair/Renew hatches as needed to restore watertight integrity.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 August 2019
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 23 August 2019 Resolved
Adjust loose belts on Main diesel engines.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 August 2019
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 23 August 2019 Resolved
Reinstall fire hose bracket and attach hose to hydrant for ready use.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 August 2019
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 23 August 2019 Resolved
Inspect & repair as needed, jet pump drive shaft. Driveshaft appeared to have excessive vibration when tested.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 August 2019
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 23 August 2019 Resolved
Provide (04) additional Visual Distress Signals(flares).
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 August 2019
Engineering › Diesel Engine (propulsion-reduction gear) › Injector (fuel injection)
Issued 31 August 2016 Resolved
Prior to carrying passengers, determine cause of loud knock on starboard propulsion engine & conduct required repairs to the satisfaction of the attending CG Marine Inspector.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Due 31 August 2016
Resolved 11 September 2017
Resolution: Engine repaired.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.