Inspection history · 21
2 November 2020
Administrative Inspection
Administrative · Marine Safety Unit Cleveland · USCG Great Lakes District (CGD-GL) · Activity 7103554
17 August 2020
Deficiency Check
Physical examination · Marine Safety Unit Cleveland · USCG Great Lakes District (CGD-GL) · Activity 7035363
29 July 2020
Administrative Inspection
Administrative · Marine Safety Unit Cleveland · USCG Great Lakes District (CGD-GL) · Activity 7017521
25 March 2020
Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Unit Cleveland · USCG Great Lakes District (CGD-GL) · Activity 6931404
29 November 2019
Type not recorded
No type recorded · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 6864560
25 November 2019
Damage Survey
Physical examination · Marine Safety Unit Cleveland · USCG Great Lakes District (CGD-GL) · Activity 6862303
25 November 2019
Administrative Inspection
Administrative · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6862326
21 October 2019
Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6838492
4 September 2019
Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6804444
25 June 2019
Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6725302
19 June 2019
Annual Inspection · DAPI Audit
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6719291
18 June 2018
Annual Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6448901
23 August 2017
Administrative Inspection
Administrative · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6249210
22 June 2017
Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6183427
19 June 2017
Administrative Inspection
Administrative · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6183396
2 June 2017
Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6163690
17 May 2017
COI Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6148463
19 April 2017
Drydock Exam
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6128482
11 August 2016
Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 5977388
16 June 2016
Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 5908961
6 June 2016
DAPI Audit · Annual Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 5906888
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 29 July 2020
Resolved
Identified twelve (12) 4" circular steel plates, "doublers", welded to the hull, covering through hull openings. Submit repair proposal for approval and complete repairs prior to carrying passengers for hire.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 July 2020
Resolved 17 August 2020
Resolution: Repair plan was accepted, appropriate through-hull closures were installed, and doublers were not required to be removed. Defeciency cleared.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 3 April 2020
Resolved
Vessel must complete a credit new to zone COI exam prior to operations.
Action required: 705 - Other - as specified
Due 18 November 2020
Resolved 1 February 2021
Resolution: Vessel placed into LAID-UP Status, and surrendered their COI. Deficiency cleared.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 25 November 2019
Resolved
Repair damage in vicinity of the bow.
Action required: 701 - Prior to carriage of passengers/cargo
Due 25 November 2019
Resolved 2 June 2020
Resolution: Repairs are complete and to the satisfaction of the CG. Deficiency is cleared.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 19 June 2019
Resolved
Both vessel fire stations have failed hoses with leaks. Isolation valve for upper deck fire station has a leaking stem. Repair leaking stem on upper deck fire station isolation valve and replace both fire station hoses with approved type. Complete new fire hose testing in presence of attending Marine Inspectors prior to carriage of passengers.
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Resolved 25 June 2019
Resolution: Hoses renewed, valve packing repaired tested hoses on station all sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 19 June 2019
Resolved
Vessel ship service generator has a fuel oil leak at the fuel oil injector pump. Repair fuel leak and run generator in the presence of attending Marine Inspectors prior to carriage of passengers.
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Resolved 25 June 2019
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 19 June 2019
Resolved
Starboard forward fuel oil remote shutoff valve for propulsion engine is leaking into the bilge. Repair/replace leaking valve to the satisfaction of attending Marine Inspectors and prior to carriage of passengers.
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Resolved 25 June 2019
Resolution: packing tightened leak corrected.
07 - Fire Safety › N/A - No Subsystem › Evaluation of crew performance (fire drills)
Issued 19 June 2019
Resolved
Conduct fire and man overboard drills with crew in the presence of attending Marine Inspectors and prior to the carriage of passengers.
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Resolved 25 June 2019
Resolution: Conducted drills on Lake Michigan, all sat.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 19 June 2019
Resolved
Vessel fire pump could not provide 50PSI for firemain system on local gauge. Provide 50PSI from fire pump for firemain to the satisfaction of attending Marine Inspectors and prior to carriage of passengers.
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Due 19 June 2019
Resolved 25 June 2019
Resolution: gauge replaced 50 psi witnessed
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 19 June 2019
Resolved
Bilge alarm audio indication for the forward compartment on vessel was inoperative. Repair/replace bilge alarm/circuit to restore audio indication to the satisfaction of attending Marine Inspectors.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 July 2019
Resolved 25 June 2019
Resolution: Alarm repaired and proven.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 19 June 2019
Resolved
Emergency lighting in the engineroom was not operating when tested and missing the cover for the batteries. Provide proof emergency lighting functions and has proper covers installed as designed.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 July 2019
Resolved 4 September 2019
Resolution: new E-Lighting unit installed in engine room.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 19 June 2019
Resolved
Vessel has plastic waste receptacles throughout the vessel. Remove and install recepticles made of Non Combustible material.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 July 2019
Resolved 25 June 2019
Resolution: plastic replaced with steel
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 19 June 2019
Resolved
Circuit Breaker on starboard side of Pilot house is not labeled on panel and was energized. Determine if breaker is connected to a load or is a spare and mark appropriately.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 July 2019
Resolved 25 June 2019
Resolution: circuit breaker labeled as spare.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 19 June 2019
Resolved
Light switch plate covers are missing in the following locations. Bride suite and Fire pump clutch switch. Provide suitable covers.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 25 June 2019
Resolution: switch plate covers installed.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 19 June 2019
Resolved
Electrical cable for hydraulic pump motor for bilge pump is of excess length, coiled and not properly secured. Shorten cable to proper length, and properly support with metallic supports 24" on center.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 July 2019
Resolved 25 June 2019
Resolution: cable shortened and supports installed.
09 - Working and Living Conditions › 092 - Working Conditions › Protection machines/parts
Issued 19 June 2019
Resolved
Fire pump pulley and belt does not have a guard to protect persons from rotating machinery, persons must put hand near belt to engage pump. Install suitable guard to prevent injury.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 July 2019
Resolved 4 September 2019
Resolution: Guard installed at firepump switch
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 19 June 2019
Resolved
Fire stations did not have spanner wrenches. Provide spanner wrenches at all Fire Hydrants.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 July 2019
Resolved 25 June 2019
Resolution: spanner wrenches intalled at stations
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 19 June 2019
Resolved
Various items in the vessels First Aid kit are expired. Replace all expired items.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 July 2019
Resolved 25 June 2019
Resolution: All required items replaced.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 19 June 2019
Resolved
Vessel did not have onboard current Certificate of Documentation (COD) Provide onboard valid COD.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 July 2019
Resolved 25 June 2019
Resolution: valid COD posted.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 19 June 2019
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 July 2019
Resolved 25 June 2019
Resolution: [name withheld] no longer being used in Safety position according to Master.
04 - Emergency Systems › N/A - No Subsystem › Man Overboard Drill (MOB)
Issued 19 June 2019
Resolved
Crew could not produce proof of First Aid training at minimum accepted amount of 50% of crew. Provide proof crew is trained in First Aid.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 July 2019
Resolved 21 October 2019
Resolution: Documentation provided for First Aid training.
Fire Fighting › Fire Pumps › Pressure
Issued 19 June 2017
Resolved
Prior to carrying passengers prove proper operation of the fire pump(60psi)per 46 CFR 181.10-1(c) old TL
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 June 2017
Resolved 22 June 2017
Resolution: Fire pump was renewed. Tested to 60 psi.
Operations/Management › Drills/Instruction › Not Conducted
Issued 17 May 2017
Resolved
Prior to carrying passengers conduct man overboard and fire drills per 46 CFR 185.420 and 176.810
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 27 May 2017
Resolved 2 June 2017
Resolution: Conducted MOB and Fire Drill.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 17 May 2017
Resolved
Update contents of First Aid kit per 46 CFR 184.710
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 June 2017
Resolved 2 June 2017
Resolution: Vessel has new first aid kit.
Fire Fighting › Fire Pumps › Pressure
Issued 17 May 2017
Resolved
Prove fire pump pressure 60 psi at the pump discharge per 46 CFR 176.810
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 June 2017
Resolved 19 June 2017
Resolution: Cleared and converted to no sail.
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 6 June 2016
Resolved
Replace 9 child lifejackets that were destroyed by inspector (yellowed and sun damage). Reduce child passenger count to no more than 7 until they are replaced or NLT 06JUL16: Cite 46 CFR 180.72(b)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 6 July 2016
Resolved 11 August 2016
Lifesaving › Hand Flares › Expired
Issued 6 June 2016
Resolved
Replace all expired flares. 6 Hand Red, 6 Orange Smoke: Prior to carrying passengers. 46 CFR 180.68(a)
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Due 6 October 2016
Resolved 16 June 2016
Resolution: 6 Red and 6 Hand Flares purchased and onboard to expire in Aug 2019
Fire Fighting › Means of Escape › Escape Route Signs
Issued 6 June 2016
Resolved
Mark forward escape hatch with at least 2" letters "Emergency Exit Keep Clear" 46 CFR 185.606
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 6 July 2016
Resolved 11 August 2016
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 6 June 2016
Resolved
Marke lifejacket locker in 2" letters with Adult/Child and number of lifejackets. 46 CFR 185.604
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 6 July 2016
Resolved 11 August 2016