Records from 2016 to 2025. Most recent: inspection, 24 April 2025.
Inspection history · 16
24 April 2025
Internal Structural Exam · Annual Inspection · Hull Examination · Deficiency Check
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 8118662
13 June 2024
Deficiency Check · Annual Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7932037
24 August 2023
Annual Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7775885
4 April 2023
Internal Structural Exam · Hull Examination
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7663019
18 May 2022
COI Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7444430
16 September 2021
Examination of Repairs · Hull Examination · Annual Inspection · Internal Structural Exam
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7313425
27 July 2021
Internal Structural Exam · Hull Examination
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7269147
21 September 2020
Annual Inspection · Deficiency Check
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7062762
11 September 2019
COI Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6809356
14 June 2019
Hull Examination · Internal Structural Exam
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6713613
19 October 2018
Administrative Inspection
Administrative · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6571135
19 September 2018
Annual Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6543882
11 September 2017
Annual Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6265166
13 June 2017
Deficiency Check
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6174626
4 October 2016
Internal Structural Exam · Hull Examination
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6024773
12 September 2016
Annual Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6011757
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 24 April 2025
No resolution recorded
All machinery and equipment must be installed and maintained in such a manner as to afford adequate protection from fire, machinery failure, and personnel injury. The exhaust hose has wear and nearing end of service life. Replace prior to next hull/drydock in 2027.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 13 June 2024
Resolved
Provide current first aid kit.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 June 2024
Resolved 23 July 2024
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 13 June 2024
Resolved
Provide new life ring with 60’ 5/16 black polypropene line and a USCG approved floating water light with 3’ to 6’ of line attached with a corrosion resistant clip.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 23 July 2024
Resolution: Cleared.
01 - Certificates & Documentation › 012 - Crew Certificates › Medical certificate
Issued 24 August 2023
Resolved
Mariner did not have a medial certificate on him.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 September 2023
Resolved 3 June 2025
Resolution: Captain had valid medical certificate
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 16 September 2021
Resolved
Stern light brackes is broken. All around white light is extinguished.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 September 2021
Resolved 18 May 2022
Resolution: New stern light installed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 27 July 2021
Resolved
The cutlass bearing was found worn and needs replacement. There was still some material left on the bearing that will be sufficient to complete the season. Credit hull was given until 30SEP21 at which time the bearing will be renewed.
Action required: 705 - Other - as specified
Due 30 September 2021
Resolved 4 October 2021
Resolution: New cutlass bearing installed.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 21 September 2020
Resolved
Engine compartment bilge alarm was not operational
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 October 2020
Resolution: Received an email video showing bilge alarm functioning
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 21 September 2020
Resolved
Engine compartment bilge suction was not operational
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 October 2020
Resolution: Received an e-mail showing the proper operation of the engine compartment bilge suction.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 21 September 2020
Resolved
Fuel strainer flame bowl was filled with water.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 October 2020
Resolution: Received an e-mail showing the fuel flame bowl was cleaned of the water.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 21 September 2020
Resolved
Company is not enrolled in a Chemical Testing Program
Action required: 17 - Rectify deficiencies prior to departure
Resolved 5 October 2020
Resolution: Owner provided a copy of enrollment certificate and drug test results
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 11 September 2019
Resolved
Main engine shut down did not work. Over ride switch could not be tested.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 September 2019
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 11 September 2019
Resolved
A number of life jackets required new retro tape
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 September 2019
04 - Emergency Systems › N/A - No Subsystem › Man Overboard Drill (MOB)
Issued 11 September 2019
Resolved
MOB drill could not be conducted due to restrictions of draft and area to maneuver.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 September 2020
Resolution: Man overboard drill completed
Operations/Management › Drills/Instruction › Not Conducted
Issued 12 September 2016
Resolved
O/O is not conducting/logging MOB or FF Drills. Prior to carrying passengers in the spring ddrill must be conducted and logged as required.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 May 2017
Resolved 8 September 2017
Resolution: Drills conducted.
Fire Fighting › Portable CO2 Fire Extinguisher › Mounting Bracket
Issued 12 September 2016
Resolved
Properly mount F/E in correct bracket prior to carrying passengers.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 May 2017
Resolved 13 June 2017
Resolution: Two CO2 cylinders were mounted and held by proper brackets.
Personnel › Certificates/Documents/Licenses › License, Master
Issued 12 September 2016
Resolved
O/O did not have his credential on his person for presentation to a CG Marine Inspector. Provide proof that he is a properly licensed Master.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 September 2016
Resolved 14 September 2016
Resolution: O/O provided proof that he is a properly licensed Master.
Documentation › Logs/Records › Drug Test Records
Issued 12 September 2016
Resolved
O/O DAPI records were not in order. Prior to the carrying of passengers he is to contact or office to arrainge an ispection of his program.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 May 2017
Resolved 14 June 2017
Resolution: Received Certificate of Enrollment
Lifesaving › Lifejacket/PFD (General) › Retroreflective Material
Issued 12 September 2016
Resolved
Prior to carrying passengers O/O must replace the retroreflective material on his child size lifejackets (2 of 3)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 May 2017
Resolved 13 June 2017
Resolution: Vessel operator purchased 02 new child size lifejackets, with proper retro reflective tapes.