MAURY USCG vessel records
← All vessels

ISLANDER

ISLANDER is a 1987 passenger vessel (inspected). The Coast Guard has recorded 16 inspections since 2016, most recently in April 2025, along with 18 deficiencies — 1 with no resolution recorded —.

Records from 2016 to 2025. Most recent: inspection, 24 April 2025.

Built
1987
Last inspected
24 April 2025
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Identity

282053
Flag
UNITED STATES
Maury page id
psix-282053

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspections, by type

Years with a record 10 calendar years (2016–2025)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. The counts in the strip above are the same counts; this table splits the inspections by the kind of activity recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Documentation record

Tonnage as PSIX records it4 - Regulatory (Subpart C or D), Net Ton
4 - Regulatory (Subpart C or D), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report

A report is not offered for this hull. Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 16

24 April 2025 Internal Structural Exam · Annual Inspection · Hull Examination · Deficiency Check
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 8118662
13 June 2024 Deficiency Check · Annual Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7932037
24 August 2023 Annual Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7775885
4 April 2023 Internal Structural Exam · Hull Examination
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7663019
18 May 2022 COI Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7444430
16 September 2021 Examination of Repairs · Hull Examination · Annual Inspection · Internal Structural Exam
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7313425
27 July 2021 Internal Structural Exam · Hull Examination
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7269147
21 September 2020 Annual Inspection · Deficiency Check
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7062762
11 September 2019 COI Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6809356
14 June 2019 Hull Examination · Internal Structural Exam
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6713613
19 October 2018 Administrative Inspection
Administrative · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6571135
19 September 2018 Annual Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6543882
11 September 2017 Annual Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6265166
13 June 2017 Deficiency Check
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6174626
4 October 2016 Internal Structural Exam · Hull Examination
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6024773
12 September 2016 Annual Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6011757

Deficiency record · 18

13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 24 April 2025 No resolution recorded
All machinery and equipment must be installed and maintained in such a manner as to afford adequate protection from fire, machinery failure, and personnel injury. The exhaust hose has wear and nearing end of service life. Replace prior to next hull/drydock in 2027.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 13 June 2024 Resolved
Provide current first aid kit.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 June 2024
Resolved 23 July 2024
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 13 June 2024 Resolved
Provide new life ring with 60’ 5/16 black polypropene line and a USCG approved floating water light with 3’ to 6’ of line attached with a corrosion resistant clip.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 23 July 2024
Resolution: Cleared.
01 - Certificates & Documentation › 012 - Crew Certificates › Medical certificate
Issued 24 August 2023 Resolved
Mariner did not have a medial certificate on him.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 September 2023
Resolved 3 June 2025
Resolution: Captain had valid medical certificate
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 16 September 2021 Resolved
Stern light brackes is broken. All around white light is extinguished.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 September 2021
Resolved 18 May 2022
Resolution: New stern light installed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 27 July 2021 Resolved
The cutlass bearing was found worn and needs replacement. There was still some material left on the bearing that will be sufficient to complete the season. Credit hull was given until 30SEP21 at which time the bearing will be renewed.
Action required: 705 - Other - as specified
Due 30 September 2021
Resolved 4 October 2021
Resolution: New cutlass bearing installed.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 21 September 2020 Resolved
Engine compartment bilge alarm was not operational
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 October 2020
Resolution: Received an email video showing bilge alarm functioning
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 21 September 2020 Resolved
Engine compartment bilge suction was not operational
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 October 2020
Resolution: Received an e-mail showing the proper operation of the engine compartment bilge suction.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 21 September 2020 Resolved
Fuel strainer flame bowl was filled with water.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 October 2020
Resolution: Received an e-mail showing the fuel flame bowl was cleaned of the water.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 21 September 2020 Resolved
Company is not enrolled in a Chemical Testing Program
Action required: 17 - Rectify deficiencies prior to departure
Resolved 5 October 2020
Resolution: Owner provided a copy of enrollment certificate and drug test results
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 11 September 2019 Resolved
Main engine shut down did not work. Over ride switch could not be tested.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 September 2019
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 11 September 2019 Resolved
A number of life jackets required new retro tape
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 September 2019
04 - Emergency Systems › N/A - No Subsystem › Man Overboard Drill (MOB)
Issued 11 September 2019 Resolved
MOB drill could not be conducted due to restrictions of draft and area to maneuver.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 September 2020
Resolution: Man overboard drill completed
Operations/Management › Drills/Instruction › Not Conducted
Issued 12 September 2016 Resolved
O/O is not conducting/logging MOB or FF Drills. Prior to carrying passengers in the spring ddrill must be conducted and logged as required.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 May 2017
Resolved 8 September 2017
Resolution: Drills conducted.
Fire Fighting › Portable CO2 Fire Extinguisher › Mounting Bracket
Issued 12 September 2016 Resolved
Properly mount F/E in correct bracket prior to carrying passengers.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 May 2017
Resolved 13 June 2017
Resolution: Two CO2 cylinders were mounted and held by proper brackets.
Personnel › Certificates/Documents/Licenses › License, Master
Issued 12 September 2016 Resolved
O/O did not have his credential on his person for presentation to a CG Marine Inspector. Provide proof that he is a properly licensed Master.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 September 2016
Resolved 14 September 2016
Resolution: O/O provided proof that he is a properly licensed Master.
Documentation › Logs/Records › Drug Test Records
Issued 12 September 2016 Resolved
O/O DAPI records were not in order. Prior to the carrying of passengers he is to contact or office to arrainge an ispection of his program.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 May 2017
Resolved 14 June 2017
Resolution: Received Certificate of Enrollment
Lifesaving › Lifejacket/PFD (General) › Retroreflective Material
Issued 12 September 2016 Resolved
Prior to carrying passengers O/O must replace the retroreflective material on his child size lifejackets (2 of 3)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 May 2017
Resolved 13 June 2017
Resolution: Vessel operator purchased 02 new child size lifejackets, with proper retro reflective tapes.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.