Records from 2005 to 2026. Most recent: inspection, 24 February 2026.
Inspection history · 36
24 February 2026
COI Inspection · MTSA/ISPS Verification
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 8314884
6 May 2025
Plan Review (Other than "T")
Administrative · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 8131779
27 March 2025
MTSA/ISPS Verification · Annual Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 8100455
17 July 2024
In-Service Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7960992
26 March 2024
Deficiency Check · Annual Inspection · MTSA Verification
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7884467
6 December 2023
Damage Survey · Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7835845
24 July 2023
Administrative Inspection · Construction Oversight
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7753070
8 June 2023
Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7709643
3 June 2023
Security Breach
Type not classified · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7710637
23 March 2023
Administrative Inspection · Deadweight Survey
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7650400
21 March 2023
Annual Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7650395
13 February 2023
Deficiency Check · Plan Review (Other than "T")
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7636241
29 November 2022
Drydock Exam · Examination of Repairs · Internal Structural Exam
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7601551
18 August 2022
In-Service Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7537875
27 May 2022
Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7460704
23 March 2022
DAPI Audit · Annual Inspection · MTSA Verification · Construction Oversight
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7417211
7 July 2021
In-Service Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7249410
10 June 2021
In-Service Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7221804
31 March 2021
DAPI Audit · MTSA Verification · COI Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7166109
3 April 2020
Annual Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6935081
10 October 2019
Deficiency Check · Damage Survey
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6832783
30 September 2019
Examination of Repairs · Administrative Inspection · Damage Survey
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6824692
28 September 2019
Type not recorded
No type recorded · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6825587
2 May 2019
Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6683877
21 March 2019
Annual Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6714200
4 June 2018
Administrative Inspection
Administrative · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6433630
18 May 2018
Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6417973
27 October 2017
Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6297731
24 October 2017
Construction Oversight · Periodic Inspection · Deficiency Check · Internal Structural Exam · Inclining Experiment · Drydock Exam · Administrative Inspection
Physical examination · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 6294030
21 October 2017
Damage Survey
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6293168
2 August 2017
Type not recorded
No type recorded · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6299080
1 June 2017
Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6162587
20 April 2017
Annual Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6131145
15 February 2017
Administrative Inspection
Administrative · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6088850
18 April 2016
MTSA Verification · COI Inspection · DAPI Audit
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 5856708
3 February 2016
In-Service Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 5812303
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 26 March 2024
Resolved
Make all WTB penetrations in the vessel pertaining to the new cable runs for the port/stbd engine data cables water tight.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 1 April 2024
Resolved 28 March 2024
Resolution: Completed during attendance.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 26 March 2024
Resolved
Remove old port and starboard engine control data cables throughout the vessel.
Condition: Design Flaw
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 April 2024
Resolved 2 April 2024
Resolution: Old cables were removed, new ones secured with metal at least every 24".
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 26 March 2024
Resolved
There is a permanently mounted extenson cord being used to provide power to the Hot Chocolate machine in the galley. Remove cord and hard wire machine.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 28 April 2024
Resolved 28 March 2024
Resolution: Corrected prior to completion of exam.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 26 March 2024
Resolved
There is electrical heat tape installed throughout the vessel that is coiled around piping and covered with insulation. Remove heat tapes or install correctly as per manf. instructions.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 April 2024
Resolved 2 April 2024
Resolution: All heat tape was removed or installed as per manufacturers instructions.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 6 December 2023
Resolved
While underway vessels master recieved a EVC Lost communication alarm. The port engine and marine gear would no longer function at the helm. Prior to carrying passengers, prove proper operation of port ZF control, including demonstarting QFA's and DVTP's upon completion of repairs to the satisfaction of an attending Coast Guard Marine Inspector.
Condition: Invalid
Action required: 705 - Other - as specified
Due 21 December 2023
Resolved 14 December 2023
Resolution: Witnessed satisfactory completion of DVTP's with no discrepancies noted.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 21 March 2023
Resolved
The throws for the breakers installed in spots #22 and #23 on the pilot house distribution panel are broken. Repair or replace the same.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 April 2023
Resolved 8 June 2023
Resolution: Broken circuit breakers have been replaced.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 21 March 2023
Resolved
There is 3/0 welding cable installed from both the negative and positive terminals on the 12V house battery between the battery and battery switch and teh battery switch and the power side of the DC panel. Replace the 3/0 welding cable with marine cable.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 April 2023
Resolved 8 June 2023
Resolution: Welding cable has been removed and replaced with marine grade.
08 - Alarms › N/A - No Subsystem › General alarm
Issued 21 March 2023
Resolved
Make repairs to and prove proper operation of the general alarm bell, port side, pilot house.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 April 2023
Resolved 1 June 2023
Resolution: General alarm bell was confirmed operational.
02 - Structural Conditions › N/A - No Subsystem › Stability/strength/loading information and instruments
Issued 7 March 2023
Resolved
The vessel has undergone a total aggregate weight change since the last stability test of approximately 3% of its displacement requiring a deadweight survey and issuance of a new stability letter.
The vessel is restricted to opration within the Chicago River, west of the Chicago Harbor Lock and restricted to the carriage of 305 total persons (combined passengers and crew) pending completion of the above.
Action required: 705 - Other - as specified
Resolved 11 May 2023
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 29 November 2022
Resolved
Make repairs to the hydraulic steering fluid leak in way of the A2 cross conddect between pump #1 and #2 on the HPU in the FO tank room.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 4 February 2023
Resolved 13 February 2023
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 29 November 2022
Resolved
Make repairs to the switchboard bus frequency meter for the starboard generator.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 4 February 2023
Resolved 13 February 2023
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 29 November 2022
Resolved
Provide chaffing gear in way of the bow thruster exhaust hose to prevent chaffing from the forepeak bilge pipe isolation valve reach rod.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 4 February 2023
Resolved 8 June 2023
Resolution: Chaffing gear was confirmed provided.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 31 March 2022
Resolved
Bow thruster battery charger does not have ammeter installed on charging circuit. Install ammeter as per CFR.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 April 2022
Resolved 27 May 2022
Resolution: New charger has inline ammeter.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 10 October 2019
Resolved
Prior to carrying passengers troubleshoot cause of port main engine overheat and automatic shutdown and correct cause, and test after repairs are complete.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 October 2019
Resolved 11 October 2019
Resolution: Valve found closed for surge tank causing system to become air bound. thermostat was replaced as a precaution.
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 21 March 2019
Resolved
AIS transmitting wrong info. IMO #, Distance A, and Distance B showing up incorrect.
33 CFR 164.46(e)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 April 2019
Resolved 2 May 2019
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 21 March 2019
Resolved
Missing non-conductive hand rail on switchboard in engine room.
46 CFR 120.330
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 April 2019
Resolved 2 May 2019
01 - Certificates & Documentation › 012 - Crew Certificates › Medical certificate
Issued 21 March 2019
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 701 - Prior to carriage of passengers/cargo
Due 21 March 2019
Resolved 17 April 2019
Lifesaving › Lifejacket/PFD (General) › Quantity
Issued 7 May 2018
Resolved
Life Jackets were not available for inspection, verification of stowage/safety plan following vessel modification. Each life jacket must be on-baord for inspection and properly marked, stowed, and verified with the safety plan.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 May 2018
Resolution: The boat has 355 ADULT and 114 CHILD LIFEJACKETS. 1) The boat has 355 ADULT and 114 CHILD LIFEJACKETS. The SAFETY PLANS mounted on the boat have 353 ADULT. There are 2 lifejackets in the pilothouse bench that were not on the Safety plan.
Documentation › Certificates/Documents › Stability Letter
Issued 7 May 2018
Resolved
Stability letter has not been issued to vessel. Stability test data and Stability Calculations are being reviewed with the Marine Safety Center.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 May 2018
Resolution: stability letter has been issued. May 17, 2018
Communications › Public Address System › Announcing Station
Issued 7 May 2018
Resolved
Unable to demonstate operation of public address system. System was not installed during vessels modification. In the presence of a CG MI, verify operation of public address system.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 May 2018
Resolution: The PA systems works. I witnessed the Captain test and conduct a safety speech
Electrical › Lighting (emergency) › Lighting Fixture
Issued 7 May 2018
Resolved
Two of the four engine room lights were not installed. Install lights as per the fire/safety plan.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 June 2018
Resolved 18 May 2018
Resolution: 2 new LED lights were installed and tested
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Controls
Issued 7 May 2018
Resolved
Operational testing of the time delay was not conducted following installation. In the presence of a CG MI a fire servicing company needs to demonstrate operation.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 May 2018
Resolution: Time delay test was completed by RELIABLE FIRE Technician Dan Ritchie.
Engineering › Diesel Engine (propulsion-reduction gear) › Pump, High Pressure (fuel injection)
Issued 21 October 2017
Resolved
Stbd engine shuts down on low oil pressure
Action required: 705 - Other - as specified
Due 31 October 2017
Resolved 27 October 2017
Resolution: Tech report submitted
Navigation › Collision/Grounding Avoidance › Radar
Issued 20 April 2017
Resolved
Repair or replace Radar
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 22 May 2017
Resolved 1 June 2017
Resolution: Radar was renewed and function tests provided NEGRES.