Records from 1988 to 1998. Most recent: inspection, 8 October 1998.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 20
8 October 1998
Administrative
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 802729
7 October 1998
Administrative
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 802727
28 October 1997
Hull Examination
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1383700
18 October 1996
Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1354022
9 October 1996
Re-Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1413058
31 January 1996
Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1192911
6 November 1995
COI Inspection · Hull Examination
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1363387
13 October 1994
Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 866107
12 September 1994
Re-Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1411017
8 November 1993
Re-Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1460664
6 October 1993
Hull Examination
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1460663
2 April 1993
Administrative
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1145032
9 September 1992
COI Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1373748
7 November 1991
Re-Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 951858
23 October 1991
Hull Examination
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1260700
3 October 1990
Re-Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1244284
19 April 1990
Hull Examination
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 903149
27 September 1989
Deficiency Check · Damage Survey
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1309202
11 September 1989
Initial Certification
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1039019
30 September 1988
Hull Examination
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1039557
Fire Fighting
Issued 28 October 1997
Resolved
PROVIDE ANNUAL SERVICE FOR ALL PORTABLE FIRE EXTINGUISHERS
Condition: Unknown
Due 28 October 1997
Resolved 28 October 1997
Unknown
Issued 28 October 1997
Resolved
CONDUCT UNDERWAY OPERATIONAL TESTS AND UNDERWAY DRILLS
Condition: Unknown
Due 28 October 1997
Resolved 28 October 1997
Construction/Loadline
Issued 28 October 1997
Resolved
PROVIDE PROPER PERMANENT CONNECTION FOR ELECTRIC BILGE PUMP IN ENGINE ROOM FORWARD
Condition: Unknown
Due 28 October 1997
Resolved 28 October 1997
Electrical
Issued 28 October 1997
Resolved
PROVIDE BELT GUARDS FOR BOTH DIESEL GENERATORS IN ENGINE ROOM
Condition: Unknown
Due 28 October 1997
Resolved 28 October 1997
Electrical
Issued 28 October 1997
Resolved
PROVIDE COVER FOR RESISTOR JUNCTION BOX ON #1 GENERATOR
Condition: Unknown
Due 28 October 1997
Resolved 28 October 1997
Engineering
Issued 28 October 1997
Resolved
PROVIDE FULL ACCESS TO HANDLE ON VALVE FOR STBD ENGINE SEA SUCTION
Condition: Unknown
Due 28 October 1997
Resolved 28 October 1997
Construction/Loadline
Issued 28 October 1997
Resolved
CAP OFF OR REMOVE UNUSED THRU-HULL FITTING IN STEERING SPACE ON THE PORT SIDE
Condition: Unknown
Due 28 October 1997
Resolved 28 October 1997
Lifesaving
Issued 28 October 1997
Resolved
PROVIDE SIXTY FT. OF BUOYANT LINE THAT IS DARK IN COLOR FOR RING BUOY
Condition: Unknown
Due 28 October 1997
Resolved 28 October 1997
Accommodation/Occupational Safety
Issued 28 October 1997
Resolved
PROPERLY CONNECT SEWAGE DISCHARGE LINE FROM HEAD TO HOLDING TANK.
Condition: Unknown
Due 28 October 1997
Resolved 28 October 1997
Accommodation/Occupational Safety
Issued 9 October 1996
Resolved
INSTALL SUITABLE RAIL AT OPENING TO STERN PLATFORM PRIOR TO CARRYING PASSENGERS BUT IN NO CASE LATER THAN 18 OCT 96.
Condition: Unknown
Due 9 October 1996
Resolved 9 October 1996
Lifesaving
Issued 9 October 1996
Resolved
AFFIX VESSEL'S NAME & HAILING PORT TO RING BUOY BEFORE CARRYING PASSENGERS BUT IN NO CASE LATER THAN 18 OCT 96.
Condition: Unknown
Due 9 October 1996
Resolved 9 October 1996
Navigation
Issued 6 November 1995
Resolved
Install mast head light.
Condition: Unknown
Due 6 November 1995
Resolved 6 November 1995
Lifesaving
Issued 6 November 1995
Resolved
Procure 3 hand held red flares.
Condition: Unknown
Due 8 November 1995
Resolved 8 November 1995
Engineering
Issued 6 November 1995
Resolved
Double clamp sea suction hose on starboard side sea chest in engine room.
Condition: Unknown
Due 8 November 1995
Resolved 8 November 1995
Construction/Loadline
Issued 6 November 1995
Resolved
Plug all through bulkhead pipe ends.
Condition: Unknown
Due 8 November 1995
Resolved 8 November 1995
Electrical
Issued 6 November 1995
Resolved
Change generator cooling hose to class II pipe on 7kw generator.
Condition: Unknown
Due 8 November 1995
Resolved 8 November 1995
Electrical
Issued 6 November 1995
Resolved
Mount 110 volts (AC) box in steering compartment.
Condition: Unknown
Due 8 November 1995
Resolved 8 November 1995
Electrical
Issued 6 November 1995
Resolved
Remove stray extension cord from fantail.
Condition: Unknown
Due 8 November 1995
Resolved 8 November 1995
Electrical
Issued 6 November 1995
Resolved
Prove proper operation of 12 KW generator.
Condition: Unknown
Due 8 November 1995
Resolved 8 November 1995
Construction/Loadline
Issued 12 September 1994
Resolved
Install 2 each plugs on pipes on collision bulkhead.
Condition: Unknown
Due 12 September 1994
Resolved 12 September 1994
Electrical
Issued 12 September 1994
Resolved
Prove proper operation of #2 (amidships forward) generator.
Condition: Unknown
Due 12 September 1994
Resolved 12 September 1994
Engineering
Issued 12 September 1994
Resolved
Install approved marine fuel filters.
Condition: Unknown
Due 12 September 1994
Resolved 12 September 1994
Fire Fighting
Issued 12 September 1994
Resolved
Prove proper operation of installed fire/bilge pump._x001C_ _x001C_
Condition: Unknown
Due 12 September 1994
Resolved 12 September 1994
Engineering
Issued 12 September 1994
Resolved
Install guards over the pulley systems on both generators and fresh water pump.
Condition: Unknown
Due 12 September 1994
Resolved 12 September 1994
Navigation
Issued 9 September 1992
Resolved
PROVE PROPER OPERATION OF MAST HEAD LIGHT._x001C_
Condition: Unknown
Due 9 October 1992
Resolved 29 September 1992
Construction/Loadline
Issued 9 September 1992
Resolved
PROVE PROPER OPERATION OF AUTOMATIC FLOAT SWITCH FOR MIDSHIP INDEPENDENT BILGE PUMP.
Condition: Unknown
Due 9 October 1992
Resolved 29 September 1992
Engineering
Issued 9 September 1992
Resolved
INSTALL REMOTE FUEL OIL SHUT-OFF'S FOR BOTH SHIP SERVICE GENERATORS.
Condition: Unknown
Due 9 October 1992
Resolved 29 September 1992
Electrical
Issued 7 November 1991
Resolved
PROVIDE GLOBES FOR LIGHT SOCKETS LOCATED IN FORWARD STORAGE COMPARTMENT ANDENGINEROOM OVERHEAD. THE ABOVE DISCREPANCY IS TO BE COMPLETED TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR.
Condition: Unknown
Due 7 November 1991
Resolved 7 November 1991
Lifesaving
Issued 3 October 1990
Resolved
VESSEL REQUIRED 3 ADDITIONAL NIGHT TIME RED HAND FLARES AND 3 ADDITIONAL ORANGE SMOKE DISTRESS SIGNALS.
Condition: Unknown
Due 3 October 1990
Resolved 3 October 1990
Lifesaving
Issued 3 October 1990
Resolved
VESSEL REQUIRED ONE ADDITIONAL TYPE I CG APPROVED LIFE JACKET.
Condition: Unknown
Due 3 October 1990
Resolved 3 October 1990
Lifesaving
Issued 3 October 1990
Resolved
DUE TO RECENT CHANGE IN OFFICE POLICY CONCERNING VIEQUES SOUND, VESSEL NOW REQUIRED 50 PERCENT PRIMARY LIFE SAVING EQUIPMENT. MINIMUM REQUIRED ONBOARDTO ACCOMODATE 21 PERSONS.
Condition: Unknown
Due 3 October 1990
Resolved 3 October 1990
Engineering
Issued 19 April 1990
Resolved
PROVIDE FLASH SHIELDS FOR RAYCOR FILTERS FOR BOTH MAIN DIESEL ENGINES.
Condition: Unknown
Due 19 April 1990
Resolved 19 April 1990
Documentation
Issued 11 September 1989
Resolved
VESSEL REQUIRED TO HAVE ON BOARD VALID FCC RADIO SAFETY CERTIFICATE.
Condition: Unknown
Due 11 September 1989
Resolved 11 September 1989