MAURY USCG vessel records
← All vessels

ADVENTURE

Built
1987
Last inspected
15 April 2026
Documentation
Valid · NVDC file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 15 April 2026
…with no type recorded12
Operational controls None recorded without a removal date
Years with a record 11 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WCS3443
282683
Flag
UNITED STATES
Maury page id
psix-282683

Documentation record

Registered dimensions (L × B × D)64.8 ft × 22.0 ft × 8.0 ft
Registered tonnagegross 76 / net 61
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderBREAUX BROTHERS ENTERPRISES INC · LOREAUVILLE, LA, UNITED STATES · built 1987
Hull materialAluminum
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portSOUTHPORT, NC
Endorsements, as the file codes themcw_un
DocumentationValid · issued 3 August 2026 · expires 31 July 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it76 - Simplified, Gross Ton
61 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
The full record for this vessel

Behind this panel: 44 inspections, each with its date, unit and type; 71 deficiencies with the resolution recorded against each; operational controls, none recorded without a removal date; no tow-unit appearances recorded; no other recorded names; the documentation record: dimensions, tonnage, builder, hailing port and endorsements. Every line is a record the Coast Guard wrote; the counts above are the same counts as in the summary, and they are free.

Professional is $39 a month or $299 a year, or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks every detail section on every vessel page, fleet watch tied to your account, and ownership records on request. Already a subscriber? Sign in.

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 44

15 April 2026 Deficiency Check · COI Inspection
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 8323892
2 December 2025 Damage Survey · Deficiency Check
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 8276336
19 November 2025 Hull Examination · Examination of Repairs · Internal Structural Exam · Drydock Exam
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 8270821
18 July 2025 Deficiency Check · Annual Inspection
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 8188329
2 April 2025 In-Service Inspection
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 8104457
2 April 2025 Type not recorded
No type recorded · Sector North Carolina · USCG East District (CGD-E) · Activity 8112017
29 October 2024 Deficiency Check · In-Service Inspection
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 8026201
8 October 2024 Damage Survey · Deficiency Check
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 8016116
11 June 2024 Deficiency Check
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 7932418
11 June 2024 In-Service Inspection
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 7932437
25 April 2024 Annual Inspection
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 7901131
22 January 2024 In-Service Inspection · Deficiency Check
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 7852645
31 October 2023 Hull Examination · Internal Structural Exam · Examination of Repairs
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 7818273
27 April 2023 Annual Inspection
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 7676562
4 October 2022 In-Service Inspection
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 7571091
4 April 2022 Annual Inspection
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 7423981
1 November 2021 Internal Structural Exam · Deficiency Check · Hull Examination
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 7343114
26 October 2021 In-Service Inspection
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 7339725
21 April 2021 Deficiency Check · COI Inspection
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 7175923
29 March 2021 Damage Survey · Deficiency Check
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 7164503
26 March 2021 Type not recorded
No type recorded · Sector North Carolina · USCG East District (CGD-E) · Activity 7166465
24 June 2020 Deficiency Check · Annual Inspection
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 6985346
18 February 2020 Type not recorded
No type recorded · Sector North Carolina · USCG East District (CGD-E) · Activity 6910855
11 February 2020 Type not recorded
No type recorded · Sector North Carolina · USCG East District (CGD-E) · Activity 6913039
8 January 2020 Hull Examination · Administrative Inspection · Drydock Exam · Examination of Repairs · Internal Structural Exam
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 6884919
25 April 2019 Deficiency Check · Annual Inspection
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 6669919
16 April 2019 Type not recorded
No type recorded · Sector North Carolina · USCG East District (CGD-E) · Activity 6698039
8 April 2019 Type not recorded
No type recorded · Sector North Carolina · USCG East District (CGD-E) · Activity 6658690
31 March 2019 Type not recorded
No type recorded · Sector North Carolina · USCG East District (CGD-E) · Activity 6653953
19 January 2019 Type not recorded
No type recorded · Sector North Carolina · USCG East District (CGD-E) · Activity 6619468
23 October 2018 Hull Examination · Internal Structural Exam · Administrative Inspection · Drydock Exam · Examination of Repairs
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 6566293
29 August 2018 Type not recorded
No type recorded · Sector North Carolina · USCG East District (CGD-E) · Activity 6528592
13 August 2018 Administrative Inspection · Deficiency Check
Physical examination · Navigation Center · Activity 6510942
5 June 2018 Administrative Inspection · Examination of Repairs
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 6434540
19 April 2018 Annual Inspection · Administrative Inspection · Deficiency Check
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 6394523
4 April 2018 Examination of Repairs · Damage Survey
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 6386350
4 April 2018 Type not recorded
No type recorded · Sector North Carolina · USCG East District (CGD-E) · Activity 6386700
7 July 2017 Type not recorded
No type recorded · Sector North Carolina · USCG East District (CGD-E) · Activity 6212690
18 April 2017 Annual Inspection · Deficiency Check
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 6125976
24 March 2017 Type not recorded
No type recorded · Sector North Carolina · USCG East District (CGD-E) · Activity 6115041
10 March 2017 Drydock Exam · Examination of Repairs · Hull Examination · Administrative Inspection · Internal Structural Exam
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 6102396
16 February 2017 Damage Survey · Administrative Inspection
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 6092863
27 April 2016 Deficiency Check · COI Inspection
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 5863713
20 January 2016 Examination of Repairs
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 5805969

Deficiency record · 71

11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 15 April 2026 Resolved
The name of a vessel must be marked or painted in clearly legible letters and numbers on each life jacket. Some life jacket markings are faded or missing. 46 CFR 185.604
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 April 2026
Resolved 21 April 2026
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 15 April 2026 Resolved
Machinery and equipment installed on each vessel must be maintained such that it is suitable for the vessel and its operation and for the purpose intended. The brackets for the steering system hydraulic lines are broken or loose and not supporting the piping. 46 CFR 182.100
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 April 2026
Resolved 21 April 2026
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 15 April 2026 Resolved
Piping, including valves, pipe fittings and flanges, conveying vapor, gas, or liquid, the temperature of which exceeds 150 °F, must be suitably insulated where necessary to prevent injuries. The port engine exhaust pipe is missing some lagging. 46 CFR 177.970
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 April 2026
Resolved 21 April 2026
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 2 December 2025 Resolved
Machinery and equipment installed on each vessel must be suitable for the vessel and its operation and for the purpose intended; the port propeller is bent causing a significant vibration.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 5 December 2025
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 18 July 2025 Resolved
A fire hose with a nozzle must be attached to each fire station at all times. The fire hose fitting and piping connection are corroded and broken, the fire hose cannot be connected. (46 CFR 181.310)
Action required: 10 - Deficiency Rectified
Resolved 18 July 2025
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 18 July 2025 Resolved
The name of the vessel must be clearly marked in legible letters on each piece of lifesaving equipment. Some life jacket markings are faded and no longer legible.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 August 2025
Resolved 19 July 2025
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 18 July 2025 Resolved
In systems and applications where flexible hoses are permitted, double hose clamps are required where practicable. The port main engine exhaust piping is missing a hose clamp.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 August 2025
Resolved 19 July 2025
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 2 April 2025 Resolved
Machinery and equipment installed on each vessel must be suitable for the vessel, its operation, and for the purpose intended; vessel experienced a spontaneous shutdown on the starboard generator and impacted radio equipment during the incident; master shifted to the port generator to continue operations and was able to restart the starboard generator. 46 CFR 182.100
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 4 April 2025
Resolved 4 April 2025
Resolution: Maintenance team discovered the racor filter (fuel) filter not seated properly and was loose due to maintenance change, they tightened the mechanical issue with the wingnut and ran the generator for 2 hours.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 29 October 2024 Resolved
A vessel must be provided with satisfactory arrangements for draining any watertight compartment. The crew was unable to draw suction from the lazarette with the bilge system.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 30 October 2024
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 11 June 2024 Resolved
Electrical equipment on a vessel must be installed and maintained to provide services necessary for safety under normal and emergency condtions; vessel master recevied throttle control alarm due to faulty battery on STBD MDE. Company replaced all batteries for port and stbd MDE's and tested and tested sat.
Condition: Invalid
Action required: 10 - Deficiency Rectified
Due 11 June 2024
Resolved 11 June 2024
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 25 April 2024 Resolved
In accordance with 47 CFR Part 80 , every vessel subject to Part III of Title III of the Communications Act must have an FCC Station License; the operator was unable to provide proof of document.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 May 2024
Resolved 26 April 2024
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 25 April 2024 Resolved
A vessel must carry a first aid kit, approval number 160.041, or a kit with an equivalent contents; the existing kit contained expired items, ensure items are replaced as necessary and the inventory is of the proper content and quantity.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 May 2024
Resolved 11 June 2024
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 25 April 2024 Resolved
The bilges of the vessel must be kept free of excessive accumulation of oil, trash, debris or other matters that might create a fire hazard or clog bilge system piping; the engine room, and lazarette bilges have an excessive amount of oily water.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 26 April 2024
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 25 April 2024 Resolved
Where flexible non-metallic piping (hose) is permitted in vital system piping it must meet the required specifications (SAE J-1942) for its intended purpose; the steering hoses have been replaced and the new hoses do not indicate they are of an approved type, provide proof of approval type.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 May 2024
Resolved 26 April 2024
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 25 April 2024 Resolved
The number and identification of the items stowed inside, and their sizes, must be marked in clearly legible letters and numbers on each container for life jackets; the markings are painted over, not visible.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 May 2024
Resolved 29 April 2024
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 25 April 2024 Resolved
Remote fuel shutoff stations must be marked in clearly legible letters at least 1 inch high indicating purpose of the valve and direction of operation; the markings have been painted over and therefore not visible.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 May 2024
Resolved 29 April 2024
01 - Certificates & Documentation › 013 - Documents › Signs, indications
Issued 25 April 2024 Resolved
On a vessel on which the number of passengers permitted on the upper deck is limited by the stability criteria, the number of passengers allowed on the upper deck must be indicated by a durable marking of at least 1 inch numbers and letters at the entryway to that deck; the markings have been painted over and therefore not visible.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 May 2024
Resolved 29 April 2024
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 4 April 2022 Resolved
The name of the vessel must be marked in clearly legible letters on each piece of lifesaving equipment; the marking on the upper deck life buoy is faded.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 April 2022
Resolved 14 April 2022
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 4 April 2022 Resolved
The name of the vessel must be marked in clearly legible letters on each piece of lifesaving equipment; the markings on numerous life jackets are faded.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 April 2022
Resolved 14 April 2022
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 4 April 2022 Resolved
Machinery and equipment installed on each vessel must be suitable for the vessel, its operation, and for the purpose intended; the port main engine starter has corroded brushes due to water intrusion.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 April 2022
Resolved 14 April 2022
09 - Working and Living Conditions › 092 - Working Conditions › Structural features (ship)
Issued 4 April 2022 Resolved
Deck rails must be designed and constructed to withstand a 200 pound point load in any direction; the upper deck port handrail has a fractured weld.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 April 2022
Resolved 14 April 2022
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 21 April 2021 Resolved
Deck rails must be designed and constructed to withstand a point load of 200 pounds. Several rails on aft luggage area have visible cracks in welds.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 3 May 2021
Resolution: Received photgraphic evidence of sat repairs
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 29 March 2021 Resolved
The cognizant OCMI may require that a vessel and its equipment undergo any additional test or inspection deemed reasonable and necessary to determine that the vessel and its equipment are suitable for the service in which they are to be employed; Vessel secured Port Engine due to low lube oil pressure alarm caused by a loose oil filter. Prove proper operation of Port Main engine.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Resolved 29 March 2021
Resolution: Vessel rep stated that oil filter was not tightened during during oil change. Filter and oil was replaced and engine tested sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 24 June 2020 Resolved
Where flexible non-metallic piping (hose) is permitted in piping systems it must meet the required specifications for its intended purpose and be otherwise acceptable to the OCMI; the supply and return fuel hoses on the stbd generator are deteriorated beyond serviceability.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 8 July 2020
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 24 June 2020 Resolved
Each battery must be secured to protect against shifting; the port and stbd generator battery boxes are too larger for the new batteries.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 8 July 2020
Resolution: Smaller battery boxes were installed.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 24 June 2020 Resolved
Each breaker panel must be labeled to indicate what equipment is served; the labeling in the electrical panel on the bridge is faded and not legible.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 8 July 2020
14 - Pollution Prevention › 144 - MARPOL Annex IV (Not Applicable to PSC Exams conducted in the U.S.) › Sewage treatment plant
Issued 3 February 2020 Resolved
Submit plans for the permanent repair/replacement of sewage tank.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 24 June 2020
Resolution: Tank was replaced in kind.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 25 April 2019 Resolved
Both main engine RACOR filters are leaking; make necessary repairs.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 28 May 2019
Resolution: Inspected Racor filters, no accumulation of fuel at time of inspection.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 25 April 2019 Resolved
Bothe main engine gauge panels are leaking oil; make necessary repairs.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 28 May 2019
Resolution: Some oil was still accumulated on the bottom of the gauge panels. This is said to be residual oil.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 25 April 2019 Resolved
The supply and return fuel hoses for the port generator are deteriorated due to dry rot; replace the hoses with an approved type.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 28 May 2019
Resolution: Hose replaced with proper hose.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 25 April 2019 Resolved
The required electrical mat for the switchboard is missing; provide an approved type mat.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 28 May 2019
Resolution: Corrected with appropriate mating.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 25 April 2019 Resolved
The vessel uses electronic navigational publications, therefore is required to have backups. The vessel does not have backup tide tables or tidal current tables. Provide for these missing publications.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 28 May 2019
Resolution: Tide tables placed on board.
10 - Safety of Navigation › N/A - No Subsystem › Other (navigation)
Issued 25 April 2019 Resolved
The vessel is not equipped with an emergency broadcast placard; provide the vessel with said document.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 28 May 2019
Resolution: Generic broadcast placard placed at operating station.
09 - Working and Living Conditions › 091 - Living Conditions › Electrical devices
Issued 25 April 2019 Resolved
There are several dead end wires under the bridge console with improper wire connectors (wire nuts); properly terminate said wires.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 28 May 2019
Resolution: Corrected.
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 13 August 2018 Resolved
The vessel is currently broadcasting (1) Zero Draft.
Condition: Invalid
Action required: 705 - Other - as specified
Due 13 September 2018
Resolved 30 August 2018
Resolution: Vessel operator notified me that they had corrected all AIS static discrepancies. Verified in VIVS.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 10 July 2018 Resolved
Replace fuel return line on stbd engine. Ensure hose is SAE J1942.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 16 July 2018
Resolution: Fuel hose replaced with correct hose.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 10 July 2018 Resolved
Secure electric fire pump supply hose, hose is currently rubbing against alternator belt.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 16 July 2018
Resolution: Hose secured to bulkhead and overhead with cable clamps.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 10 July 2018 Resolved
Make repairs to main engine room hatch. 1 of 3 dog studs is sheered.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 16 July 2018
Resolution: Hatch corrected and tested sat.
Communications › Alarms/Indicators › Bilge Alarm
Issued 19 April 2018 Resolved
Relable all 4 bilge high water alarms in pilot house.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 11 May 2018
Resolution: Alarm indicators clearly relabled.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 19 April 2018 Resolved
Lower N.U.C. light is not operable, make repairs.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 11 May 2018
Resolution: Nav light tested sat.
Pollution Prevention/Response › Prevention Equipment › Sewage System Piping
Issued 19 April 2018 Resolved
Crop out wasted pipe to STBD sewage tank, make appropriate repairs.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 11 May 2018
Resolution: Pipe cropped out and new pipe rewelded in place.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 19 April 2018 Resolved
Remove expired meds from all first aid kits. If kept onboard stow in appropriately marked container.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 15 May 2018
Resolution: Expired meds removed from vessel.
Engineering › Bilge Water Management System › Valve
Issued 19 April 2018 Resolved
Label valves for both electric and engine driven bilge/fire pumps. Create and post diagram and instructions so all crew are able to operate in an emergency.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 11 May 2018
Resolution: Valves labled and diagram posted.
Engineering › Bilge Water Management System › Valve
Issued 19 April 2018 Resolved
Repack valve stem or replace valve to engine driven pump - main valve.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 11 May 2018
Resolution: Valve was repacked.
Electrical › Electrical Distribution System (service) › Non-conducting Deck Covering
Issued 19 April 2018 Resolved
Place electric insulation matting in front of switchboard. Ensure it's secured in a way that is semi-permenant.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 11 May 2018
Resolution: Non conductive matting in place.
Electrical › Electrical Distribution System (emergency) › Switchboard
Issued 19 April 2018 Resolved
Secure port voltmeter in switchboard.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 11 May 2018
Resolution: Gauge secured.
Engineering › Generator (propulsion/auxiliary-electric) › Indicator Circuitry
Issued 19 April 2018 Resolved
Make repairs to port generator lube oil pressure gauge.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 11 May 2018
Resolution: Wire lead to gauge was reconnected.
Engineering › Diesel Engine (propulsion-reduction gear) › Exhaust Manifold
Issued 19 April 2018 Resolved
Install new exhaust lagging to port MDE.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 19 April 2018
Resolution: Photo recieved and accepted of repairs.
Fire Fighting › Combustible Materials › Insulation
Issued 19 April 2018 Resolved
Clean on top of port MDE and overhead - excessive dust buildup - fire hazzard.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 19 April 2018
Resolution: Deficiency corrected
Engineering › Lubricating Oil Service System › Hose
Issued 19 April 2018 Resolved
Replace 2 reduction gear oil lines for STBD main - ensure hose are SAE J1942.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 11 May 2018
Resolution: Hose have been replaced with SAE J-1942 hose.
Engineering › Diesel Engine (propulsion-reduction gear) › Turbocharger
Issued 19 April 2018 Resolved
Troubleshoot and repair turbo drain line leak for stbd main, also replace flexible hose portion.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 11 May 2018
Resolution: Satisfactory repairs completed.
Engineering › Freshwater System (jacketwater cooling) › Hose
Issued 19 April 2018 Resolved
Attach bracket for S/W cooling hose outboard of STBD main.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 11 May 2018
Resolution: Bracket attached.
Construction/Loadline › Penetrations › Pipe Flange
Issued 4 April 2018 Resolved
Make permanent repairs to wasted S/W suction for port generator.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 5 April 2018
Resolution: Proper repairs complete.
Engineering › Bilge Water Management System › Not Operational
Issued 18 April 2017 Resolved
Engine driven bilge/fire pump is inoperable. Make repairs and prove proper operation to attending MI prior to operation.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 19 April 2017
Resolution: Documentation received to clear deficiency.
Electrical › Electrical Distribution System (service) › Wiring
Issued 18 April 2017 Resolved
Bilge alarm wiring in fwd void is speaker wire. Replace with approved boat cable.
Action required: 705 - Other - as specified
Due 18 May 2017
Resolved 11 May 2017
Resolution: Bilge alarm has been rewired and tested sat.
Electrical › Electrical Distribution System (service) › Wiring
Issued 18 April 2017 Resolved
Remove or properly terminate dead end wires under the console on nav bridge (approx 6).
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 May 2017
Resolved 11 May 2017
Resolution: Wires have been removed.
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 18 April 2017 Resolved
Rescue line on lifebuoy was measured at approx 30 ft. Line must be 60 ft floating line, 5/16" minimum diameter.
Action required: 705 - Other - as specified
Due 18 May 2017
Resolved 11 May 2017
Resolution: A new lifeline of the proper length has been placed onboard.
Pollution Prevention/Response › Prevention Equipment › Sewage System Piping
Issued 18 April 2017 Resolved
Pump out line for female MSD is corroded through. Secure head with padlock until repairs are made. Notify USCG with repair proposal.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 May 2017
Resolved 11 May 2017
Resolution: The sewage line was removed and replaced with a combination of metallic and non-metallic piping. The through bulkhead penetration was sat.
Deck/Cargo › Holds/Tanks › Hatch Cover
Issued 18 April 2017 Resolved
Adjust fuel compartment and steering compartment water tight hatch.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 May 2017
Resolved 11 May 2017
Resolution: Parts were replaced and the hatch checked sat.
Construction/Loadline › Hull › Hull Plating
Issued 10 March 2017 Resolved
Repair the fracture in the strengthening plate iwo the stbd strut.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 20 March 2017
Resolved 14 March 2017
Resolution: Fracture had been re-welded, all sat.
Engineering › Fuel Oil Service System › Hose
Issued 10 March 2017 Resolved
Replace the fuel hoses on the fuel tank.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 20 March 2017
Resolved 14 March 2017
Resolution: Verified new hose for fuel tank.
Engineering › Bilge Water Management System › Not Installed
Issued 10 March 2017 Resolved
Install a bilge alarm in the #1 void or remove the through hull penetration if the removal of the sensor is undertaken, provide repair proposal.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 20 March 2017
Resolved 14 March 2017
Resolution: Verified installation and operation of bilge alarm in the #1 void.
Electrical › Lighting (service) › Lighting Fixture
Issued 10 March 2017 Resolved
Properly install the light fixture on the stbd side of the engine room.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 20 March 2017
Resolved 14 March 2017
Resolution: Verified installation of proper light fixture in stbd engine room.
Navigation › Piloting/Steering › Notices to Navigation
Issued 27 April 2016 Resolved
Provide the vessel with the Local Notice to Mariners.
Due 13 May 2016
Resolved 13 May 2016
Resolution: The local NTM have been saved on tablets which the vsl Captains carry.
Personnel › Certificates/Documents/Licenses › License, Radio Officer
Issued 27 April 2016 Resolved
Provide proof of a Marine Radio Operator Permit for the Master of the vessel, [name withheld].
Due 13 May 2016
Resolved 2 May 2016
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 27 April 2016 Resolved
Properly label the ring buoy on the 01 deck due to deterioration.
Due 13 May 2016
Resolved 13 May 2016
Resolution: The ring buoy has been properly labeled.
Lifesaving › Lifejacket/PFD (Type I) › Retroreflective Material
Issued 27 April 2016 Resolved
Replace the reflective the life jackets as needed, five noted.
Due 13 May 2016
Resolved 13 May 2016
Resolution: Lifejackets were spot checked and verified that several had new retro-reflective tape.
Engineering › Sea-water System (primary cooling) › Piping
Issued 27 April 2016 Resolved
Repair salt water leaks in the exhaust piping on both port and stbd main engines.
Due 27 May 2016
Resolved 27 May 2016
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 27 April 2016 Resolved
Repair the exhaust pipe leak on the stbd main engine.
Due 27 May 2016
Resolved 27 May 2016
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 27 April 2016 Resolved
Repairs the fractured welds in the handrail as noted and discussed.
Due 13 May 2016
Resolved 13 May 2016
Resolution: The concerned area of railing has been satisfactorily repaired.
Stability › Watertight Integrity › General
Issued 27 April 2016 Resolved
Adjust the watertight hatches as needed to insure proper operation of all closures.
Due 13 May 2016
Resolved 13 May 2016
Resolution: Checked WTH's, all are adjusted properly.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.