Records from 1987 to 2025. Most recent: inspection, 5 May 2025.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 54
5 May 2025
Annual Inspection
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 8128795
30 April 2024
COI Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7901358
27 March 2024
Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 7878997
15 August 2023
Annual Inspection
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 7765785
27 April 2022
Annual Inspection
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 7436072
8 March 2022
Drydock Exam · Hull Examination · Internal Structural Exam
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 7414081
15 October 2021
Annual Inspection
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 7333570
6 May 2020
Drydock Exam · DAPI Audit · Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 7043296
21 February 2020
Construction Oversight
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6913044
14 May 2019
Administrative Inspection · DAPI Audit · COI Inspection
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 6681087
30 October 2018
Deficiency Check
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 6571195
14 September 2018
DAPI Audit · Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 6547349
8 March 2018
Hull Examination
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 6368388
13 September 2017
Annual Inspection · DAPI Audit
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 6265235
1 September 2016
Deficiency Check
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 5990596
11 August 2016
Annual Inspection
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 5970552
14 April 2016
Administrative Inspection · Hull Examination
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 5856462
13 May 2014
Deficiency Check · COI Inspection · DAPI Audit · Administrative Inspection
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 4857193
24 March 2014
Hull Examination · Internal Structural Exam
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 4821912
5 December 2011
Administrative Inspection
Administrative · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 4202036
25 March 2010
Hull Examination
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 3689862
20 May 2008
Annual Inspection
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 3213841
29 April 2008
Hull Examination
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 3188637
22 May 2007
Annual Inspection
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 2931813
23 May 2006
Annual Inspection
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 2630488
17 April 2006
Hull Examination
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 2630463
25 May 2005
Re-Inspection
Physical examination · MSFO CAPE COD · USCG Northeast District (CGD-NE) · Activity 2367233
6 April 2005
Hull Examination
Physical examination · MSFO CAPE COD · USCG Northeast District (CGD-NE) · Activity 2326288
26 January 2004
COI Inspection · Hull Examination
Physical examination · MSFO CAPE COD · USCG Northeast District (CGD-NE) · Activity 1992598
20 May 2003
Re-Inspection
Physical examination · MSFO CAPE COD · USCG Northeast District (CGD-NE) · Activity 1797836
22 May 2002
Re-Inspection
Physical examination · MSFO CAPE COD · USCG Northeast District (CGD-NE) · Activity 1619092
1 April 2002
Hull Examination
Physical examination · MSFO CAPE COD · USCG Northeast District (CGD-NE) · Activity 1600127
21 May 2001
Re-Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1063422
22 May 2000
Re-Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1051470
6 March 2000
Hull Examination
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 815694
20 May 1999
COI Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 804638
21 May 1998
Re-Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 791943
10 February 1998
Hull Examination
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 775225
5 June 1997
Re-Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1123497
20 May 1996
COI Inspection · Deficiency Check
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1087972
10 May 1995
Re-Inspection · Deficiency Check
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1182958
26 January 1995
Hull Examination
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1407440
10 May 1994
Re-Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1398087
25 May 1993
COI Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1356323
9 June 1992
Re-Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1262350
10 April 1992
Hull Examination
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 958220
10 May 1991
Re-Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 899981
6 July 1990
COI Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 909679
4 May 1989
Re-Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1035418
20 April 1989
Hull Examination
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1197813
22 December 1988
Drydock Extension
Administrative · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1034587
21 June 1988
Re-Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 895716
2 July 1987
Initial Certification
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1023295
1 July 1987
Hull Examination
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1023293
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 30 April 2024
Resolved
Shutoff valves, installed so as to close against the fuel flow, must be fitted in the fuel supply lines, one at the tank connection and one at the engine end of the fuel line to stop fuel flow when servicing accessories. The shutoff valve at the tank must be manually operable from outside the compartment in which the valve is located, preferably from an accessible position on the weather deck. If the handle to the shutoff valve at the tank is located inside the machinery space, it must be located so that the operator does not have to reach more than 300 millimeters (12 inches) into the machinery space and the valve handle must be shielded from flames by the same material the hull is constructed of, or some noncombustible material. Electric solenoid valves must not be used, unless used in addition to the manual valve. Shut off valve was located Approx. 2 1/2' into the compartment. Install a remote pull for the emergency fuel shutoff valve. 46CFR182.455(b)(4)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 1 May 2024
Resolution: Received video of newly install pull shut off for emergency fuel handle
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 15 October 2021
Resolved
The owner, managing operator or a qualified servicing facility shall conduct the following inspections and tests: for portable fire extinguishers, the inspections, maintenance procedures and hydrostatic pressure tests required by Chapter 4 of NFPA 10. Portable fire extinguishers were last inspected by third party on June 11, 2020.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 March 2022
Resolution: Vessel has undergone 3rd party servicing of FF equipment.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 15 October 2021
Resolved
The owner, managing operator or a qualified servicing facility shall conduct the following inspections and tests: for fixed gas fire extinguishing systems, the inspections and tests required by Table 176.810(b)(2), in addition to 46 CFR 147.60, 147.65, 147.66 and 147.67.
Pre-engineered fire extinguishing equipment was last inspected by third party on June 11, 2020.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 March 2022
Resolution: Vessel has undergone 3rd party servicing of FF equipment.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 15 October 2021
Resolved
A submersible electric bilge pump bilge pump must be listed by an independent laboratory as meeting the requirements in UL 1113. The installed bilge pump does not meet UL 1113.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 8 March 2022
Resolution: Bilge pump has been replaced by the appropriate RULE 2000.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 15 October 2021
Resolved
Remote fuel shutoff stations must be marked in clearly legible letters at least 1 inch high indicating purpose of the valve and direction of operation. Letters were faded to the point of illegibility.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 8 March 2022
Resolution: Fuel shutoff stencils were re-done, and legible.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 15 October 2021
Resolved
A vessel must undergo an annual inspection within the 3 months before or after each anniversary date. Vessel continued to operate beyond its 90-day window.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 15 October 2021
Resolution: Deficiency was cleared on the spot.
Fire Fighting › Portable CO2 Fire Extinguisher › Mounting Bracket
Issued 13 September 2017
Resolved
The vessel's B-II portable fire extinguishing bracket is severely wasted. Provide vessel with a new bracket.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 May 2018
Resolved 30 October 2018
Resolution: Vessel installed a new fire extinguisher bracket.
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 11 August 2016
Resolved
Vessel does not have their child and adult lifejackets stowage properly labeled with amount of each type. Properly label the stowage compartment properly with number of each lifejacket.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 August 2016
Resolved 1 September 2016
Resolution: Verified vessel has properly labeled their lifejacket stowage compartments; all sat.
Documentation › Logs/Records › Logbook/Record (unofficial)
Issued 11 August 2016
Resolved
Vessel has not been logging man overboard and fire drills. Log drills and submit to CG.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 August 2016
Resolved 1 September 2016
Resolution: Verified vessel has been properly logging drills; all sat.
Documentation › Logs/Records › Drug Test Records
Issued 11 August 2016
Resolved
Vessel has a new master operating with the company and is not listed on the drug consortium information. Provide an up to date drug consortium document.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 August 2016
Resolved 1 September 2016
Resolution: Verified DAPI information; all sat.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 13 May 2014
Resolved
Replace ring buoy waterlight. Vessel restricted to daylight operations only.
Due 27 May 2014
Resolved 27 June 2014
Resolution: Replace ring buoy waterlight.
Fire Fighting › Fire Bucket › Quantity
Issued 13 May 2014
Resolved
Provide an additional fire bucket to meet the 03 bucket requirement iaw 46 CFR 181.610.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 June 2014
Resolution: Provided an additional fire bucket to meet the 03 bucket requirement iaw 46 CFR 181.610.
Lifesaving › Lifebuoys › Approval
Issued 13 May 2014
Resolved
Provide/install a ring life buoy aboard the vessel. Approval #160.050.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 June 2014
Resolution: Installed approved ring life buoy aboard the vessel.
Communications › Alarms/Indicators › High Water Alarm
Issued 13 May 2014
Resolved
Prove proper operation of bilge high water alarm.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 June 2014
Resolution: Proved proper operation of bilge high water alarm.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 5 December 2011
Resolved
The vessel's total persons allowed has been reduced to 12 total persons. This requirement is effective until you come into compliance with the requirements of the new stability regulations.
Action required: 705 - Other - as specified
Due 5 December 2011
Resolved 16 May 2013
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 26 May 2004
Resolved
INSTALL CLIP FOR LIGHT ATTACHMENT TO THE LIFE RING.
Action required: 705 - Other - as specified
Due 15 June 2004
Resolved 26 May 2004
Resolution: CLIP INSTALLED.
Engineering
Issued 10 February 1998
Resolved
REPLACE PORT/STBD SUPPLY/EXHAUST ENGINE COMPARTMENT VENT DUCTS.
Condition: Unknown
Due 10 March 1998
Resolved 22 May 1998
Lifesaving
Issued 20 May 1996
Resolved
CONDUCT ANNUAL UNDERWAY DRILLS IN THE PRESENCE OF A MARINE INSPECTOR.
Condition: Unknown
Due 9 July 1996
Resolved 27 September 1996
Documentation
Issued 20 May 1996
Resolved
CONDUCT PRE-EMPLOYMENT CHEMICAL TESTING AND PROGRAM TRAINING FOR VESSEL OPERATORS.
Condition: Unknown
Due 8 October 1996
Resolved 10 October 1996
Lifesaving
Issued 20 May 1996
Resolved
EMERGENCY CHECK OFF LIST WAS NOT POSTED ON BOARD THE VESSEL.
Condition: Unknown
Due 9 July 1996
Resolved 27 September 1996
Lifesaving
Issued 20 May 1996
Resolved
ADD THE PROPER TYPE AND AMOUNT OF REFLECTIVE TAPE AND LIFE LINE TO THE RINGBUOY.
Condition: Unknown
Due 9 July 1996
Resolved 27 September 1996
Lifesaving
Issued 20 May 1996
Resolved
POST LIFE JACKET DONNING PROCEDURES ONBOARD THE VESSEL.
Condition: Unknown
Due 9 July 1996
Resolved 27 September 1996
Documentation
Issued 10 May 1995
Resolved
PROVIDE DOCUMENTATION FOR DRUG TESTING PROGRAM FOR ALL CREW MEMBERS.
Condition: Unknown
Due 28 June 1995
Resolved 15 August 1995
Lifesaving
Issued 10 May 1995
Resolved
CONDUCT FIRE AND BOAT DRILLS IN THE PRESENCE OF A COAST GUARD MARINE INSPECTOR.
Condition: Unknown
Due 28 June 1995
Resolved 15 August 1995
Construction/Loadline
Issued 10 May 1995
Resolved
DOUBLE CLAMP RAW WATER INTAKE HOSE FOR THE MAIN ENGINE.
Condition: Unknown
Due 28 June 1995
Resolved 15 August 1995
Documentation
Issued 10 May 1995
Resolved
UPDATE VESSEL'S RADIO STATION LICENSE.
Condition: Unknown
Due 28 June 1995
Resolved 15 August 1995
Navigation
Issued 26 January 1995
Resolved
REPAIR STEERING RAM ARM.
Condition: Unknown
Due 23 March 1995
Resolved 24 March 1995