MAURY USCG vessel records
← All vessels

JOHN H. BURMAN

JOHN H. BURMAN is a 1984 passenger vessel (inspected). The Coast Guard has recorded 17 inspections since 2016, most recently in May 2025, along with 10 deficiencies.

Records from 2016 to 2025. Most recent: inspection, 5 May 2025.

Built
1984
Last inspected
5 May 2025
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 5 May 2025
Operational controls None recorded without a removal date
Years with a record 10 calendar years (2016–2025)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WTC-5568
282812
Flag
UNITED STATES
Maury page id
psix-282812

Documentation record

Tonnage as PSIX records it2 - Simplified, Gross Ton
1 - Simplified, Net Ton
0 - Dead Weight, Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report

A report is not offered for this hull. Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 17

5 May 2025 Annual Inspection
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 8128795
30 April 2024 COI Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7901358
27 March 2024 Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 7878997
15 August 2023 Annual Inspection
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 7765785
27 April 2022 Annual Inspection
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 7436072
8 March 2022 Drydock Exam · Hull Examination · Internal Structural Exam
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 7414081
15 October 2021 Annual Inspection
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 7333570
6 May 2020 Drydock Exam · DAPI Audit · Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 7043296
21 February 2020 Construction Oversight
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6913044
14 May 2019 Administrative Inspection · DAPI Audit · COI Inspection
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 6681087
30 October 2018 Deficiency Check
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 6571195
14 September 2018 DAPI Audit · Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 6547349
8 March 2018 Hull Examination
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 6368388
13 September 2017 Annual Inspection · DAPI Audit
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 6265235
1 September 2016 Deficiency Check
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 5990596
11 August 2016 Annual Inspection
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 5970552
14 April 2016 Administrative Inspection · Hull Examination
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 5856462

Deficiency record · 10

13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 30 April 2024 Resolved
Shutoff valves, installed so as to close against the fuel flow, must be fitted in the fuel supply lines, one at the tank connection and one at the engine end of the fuel line to stop fuel flow when servicing accessories. The shutoff valve at the tank must be manually operable from outside the compartment in which the valve is located, preferably from an accessible position on the weather deck. If the handle to the shutoff valve at the tank is located inside the machinery space, it must be located so that the operator does not have to reach more than 300 millimeters (12 inches) into the machinery space and the valve handle must be shielded from flames by the same material the hull is constructed of, or some noncombustible material. Electric solenoid valves must not be used, unless used in addition to the manual valve. Shut off valve was located Approx. 2 1/2' into the compartment. Install a remote pull for the emergency fuel shutoff valve. 46CFR182.455(b)(4)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 1 May 2024
Resolution: Received video of newly install pull shut off for emergency fuel handle
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 15 October 2021 Resolved
The owner, managing operator or a qualified servicing facility shall conduct the following inspections and tests: for portable fire extinguishers, the inspections, maintenance procedures and hydrostatic pressure tests required by Chapter 4 of NFPA 10. Portable fire extinguishers were last inspected by third party on June 11, 2020.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 March 2022
Resolution: Vessel has undergone 3rd party servicing of FF equipment.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 15 October 2021 Resolved
The owner, managing operator or a qualified servicing facility shall conduct the following inspections and tests: for fixed gas fire extinguishing systems, the inspections and tests required by Table 176.810(b)(2), in addition to 46 CFR 147.60, 147.65, 147.66 and 147.67. Pre-engineered fire extinguishing equipment was last inspected by third party on June 11, 2020.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 March 2022
Resolution: Vessel has undergone 3rd party servicing of FF equipment.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 15 October 2021 Resolved
A submersible electric bilge pump bilge pump must be listed by an independent laboratory as meeting the requirements in UL 1113. The installed bilge pump does not meet UL 1113.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 8 March 2022
Resolution: Bilge pump has been replaced by the appropriate RULE 2000.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 15 October 2021 Resolved
Remote fuel shutoff stations must be marked in clearly legible letters at least 1 inch high indicating purpose of the valve and direction of operation. Letters were faded to the point of illegibility.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 8 March 2022
Resolution: Fuel shutoff stencils were re-done, and legible.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 15 October 2021 Resolved
A vessel must undergo an annual inspection within the 3 months before or after each anniversary date. Vessel continued to operate beyond its 90-day window.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 15 October 2021
Resolution: Deficiency was cleared on the spot.
Fire Fighting › Portable CO2 Fire Extinguisher › Mounting Bracket
Issued 13 September 2017 Resolved
The vessel's B-II portable fire extinguishing bracket is severely wasted. Provide vessel with a new bracket.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 May 2018
Resolved 30 October 2018
Resolution: Vessel installed a new fire extinguisher bracket.
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 11 August 2016 Resolved
Vessel does not have their child and adult lifejackets stowage properly labeled with amount of each type. Properly label the stowage compartment properly with number of each lifejacket.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 August 2016
Resolved 1 September 2016
Resolution: Verified vessel has properly labeled their lifejacket stowage compartments; all sat.
Documentation › Logs/Records › Logbook/Record (unofficial)
Issued 11 August 2016 Resolved
Vessel has not been logging man overboard and fire drills. Log drills and submit to CG.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 August 2016
Resolved 1 September 2016
Resolution: Verified vessel has been properly logging drills; all sat.
Documentation › Logs/Records › Drug Test Records
Issued 11 August 2016 Resolved
Vessel has a new master operating with the company and is not listed on the drug consortium information. Provide an up to date drug consortium document.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 August 2016
Resolved 1 September 2016
Resolution: Verified DAPI information; all sat.

Ownership record