Records from 1996 to 2011. Most recent: inspection, 15 February 2011.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 15
15 February 2011
Annual Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 3945738
4 October 2006
Administrative Inspection
Administrative · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 2793526
18 October 2005
Annual Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 2516638
9 November 2004
Deficiency Check · Annual Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 2237527
6 October 2004
Hull Examination
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 2214697
18 November 2003
Annual Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 1949777
3 October 2002
Hull Examination · COI Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 1683140
11 October 2001
Re-Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1445885
17 October 2000
Hull Examination · Re-Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1467247
2 November 1999
COI Inspection · Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1456775
21 October 1998
Re-Inspection · Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1465433
18 May 1998
Administrative
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1124958
21 January 1998
Re-Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1469167
22 November 1996
Initial Certification · Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1428818
1 November 1996
Plan Review "T" Boat
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1371594
Documentation › Logs/Records › Drug Test Records
Issued 18 October 2005
Resolved
Provide copy of MIS report for 2004.
Due 25 October 2005
Resolved 18 October 2005
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 18 October 2005
Resolved
Properly mount STBD navigational lens.
Due 25 October 2005
Resolved 18 October 2005
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 18 October 2005
Resolved
Refresh and replace all expired items in the first aid kit.
Due 25 October 2005
Resolved 18 October 2005
Fire Fighting › Fixed Fire Detection System › Smoke Detectors
Issued 18 October 2005
Resolved
Make forward smoke detector operational.
Due 25 October 2005
Resolved 18 October 2005
Engineering › Generator (propulsion/auxiliary-electric) › Feeder Circuitry
Issued 18 October 2005
Resolved
Properly replace missing double clamp on the exhaust for the generator.
Due 25 October 2005
Resolved 18 October 2005
Documentation › Certificates/Documents › FCC SSL
Issued 9 November 2004
Resolved
FCC ships safety expired.
Action required: 705 - Other - as specified
Due 9 December 2004
Resolved 26 November 2004
Resolution: Rcvd new FCC safety
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 9 November 2004
Resolved
Provide more descriptive entries for recording drills.
Action required: 705 - Other - as specified
Due 9 December 2004
Resolved 17 November 2004
Engineering › Sea-water System (primary cooling) › Piping
Issued 9 November 2004
Resolved
Provide support for generator exaust hose at shell penetration
Action required: 705 - Other - as specified
Due 9 December 2004
Resolved 17 November 2004
Resolution: support installed
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 9 November 2004
Resolved
Provide rail courses with openings no greater than 4" IAW 46CFR 177.900 on fwd bow passenger area.
Action required: 701 - Prior to carriage of passengers/cargo
Due 21 November 2004
Resolved 17 November 2004
Lifesaving › Hand Flares › Quantity
Issued 18 November 2003
Resolved
Provide an additional 3 handheld red/orange emergency signals.
Action required: 701 - Prior to carriage of passengers/cargo
Due 18 December 2003
Resolved 18 November 2003
Lifesaving › Lifebuoys
Issued 18 November 2003
Resolved
Renew ring bouy.
Action required: 701 - Prior to carriage of passengers/cargo
Due 18 December 2003
Resolved 18 November 2003
Engineering
Issued 3 October 2002
Resolved
RE-NEW THREE (3) THRU-HULL FITTINGS AND ASOCIATED VALVES.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 9 October 2002
Resolved 3 October 2002
Engineering › Shafting/Propeller Arrangements
Issued 3 October 2002
Resolved
TIGHTEN NUTS ON STBD PROPELLER LEGACY COMPONENT DESC: Propeller (fixed pitch)
Action required: 705 - Other - as specified
Due 9 October 2002
Resolved 3 October 2002
Engineering
Issued 3 October 2002
Resolved
PROVIDE VALVES FOR TWO (2) SINK DRAINS WHICH ARE < 6" FROM WATERLINE.
Action required: 705 - Other - as specified
Due 9 October 2002
Resolved 3 October 2002
Electrical › Electrical Distribution System (service)
Issued 3 October 2002
Resolved
PROVIDE ADEQUATE SUPPORT OF WIRING IN ENGINE ROOM WITH METALLIC/RUBBER GROMMET TYPE. SUPPORT WIRE RUNS AT INTERVALS NOT MORE THAT 24" APART. LEGACY COMPONENT DESC: Wiring
Action required: 705 - Other - as specified
Due 9 October 2002
Resolved 9 October 2002
Lifesaving
Issued 2 November 1999
Resolved
INSTALL RETROREFLECTIVE TAPE ON RING BUOY AND MARK WITH VESSELS NAME.
Condition: Unknown
Due 18 January 2000
Resolved 18 January 2000
Documentation
Issued 2 November 1999
Resolved
PROVIDE DOCUMENTATION OF EMPLOYEE ASSISTANCE PROGRAM.
Condition: Unknown
Due 18 January 2000
Resolved 18 January 2000
Electrical
Issued 2 November 1999
Resolved
INSTALL PROTECTIVE GLOBE ON LIGHT BULB IN LAZARETTE.
Condition: Unknown
Due 18 January 2000
Resolved 18 January 2000
Electrical
Issued 2 November 1999
Resolved
PROPERLY HARDWIRE MOTOR FOR AIR HORN OR REMOVE SAME FROM THE VESSEL.
Condition: Unknown
Due 18 January 2000
Resolved 18 January 2000
Electrical
Issued 2 November 1999
Resolved
MAKE RECEPTICLES IN MACHINERY SPACE DRIP PROOF.
Condition: Unknown
Due 18 January 2000
Resolved 18 January 2000
Lifesaving
Issued 2 November 1999
Resolved
PRESENT VESSEL AND CREW FOR UNDERWAY DRILLS UPON COMPLETION OF RESCUE PROCEDURES.
Condition: Unknown
Due 18 January 2000
Resolved 18 January 2000
Navigation
Issued 2 November 1999
Resolved
PROVIDE AND POST EMERGENCY BROADCAST PLACARD AT BOTH RADIO STATIONS.
Condition: Unknown
Due 18 January 2000
Resolved 18 January 2000
Accommodation/Occupational Safety
Issued 2 November 1999
Resolved
INSTALL SPILL RAIL ON STOVE TOP AND LATCH ON OVEN DOOR.
Condition: Unknown
Due 18 January 2000
Resolved 18 January 2000
Lifesaving
Issued 2 November 1999
Resolved
PROVIDE RESCUE LADDER AND PLATFORM OR AN EQUIVALENT APPROVED PROCEDURE TO CONDUCT MAN OVERBOARD RESCUE.
Condition: Unknown
Due 18 January 2000
Resolved 18 January 2000