Records from 1987 to 2000. Most recent: inspection, 13 June 2000.
Documentation record
Registered dimensions (L × B × D)28.1 ft × 9.5 ft × 5.0 ft
Registered tonnagegross 8 / net 7
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderDELTA BOAT WORKS · CAPE CANAVERAL FL · built 1987
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portCHARLESTON, SC
Trade endorsementsCoastwise, unrestricted, Fishery
DocumentationExpired · issued 30 June 2004
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it7 - Simplified, Net Ton
8 - Simplified, Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 30
13 June 2000
Re-Inspection
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1439045
16 July 1999
Deficiency Check
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1100196
15 June 1999
COI Inspection
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1369218
6 January 1999
Type not recorded
No type recorded · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 652060
21 December 1998
Hull Examination
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1372453
30 June 1998
Re-Inspection
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1400876
31 July 1997
Re-Inspection
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1119494
21 May 1997
Deficiency Check
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 776633
21 November 1996
Administrative
Administrative · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1179507
18 September 1996
Hull Examination
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 962120
1 July 1996
Deficiency Check
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1086356
19 June 1996
COI Inspection
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 885912
15 August 1995
Deficiency Check
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 873581
12 July 1995
Re-Inspection
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1192856
27 September 1994
Hull Examination
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 863374
10 August 1994
Re-Inspection
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1172048
21 June 1993
COI Inspection
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1151682
16 June 1993
Administrative
Administrative · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1151683
16 September 1992
Hull Examination
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 955992
26 June 1992
Re-Inspection
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 962757
18 July 1991
Re-Inspection
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 946988
28 March 1991
Hull Examination
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 905674
1 August 1990
Deficiency Check
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 907270
21 June 1990
COI Inspection
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 904768
15 November 1989
Hull Examination
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 902659
22 June 1989
Re-Inspection
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1341992
12 December 1988
Hull Examination
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1034515
7 September 1988
Re-Inspection
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1351913
29 April 1988
Deficiency Check
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1353140
25 June 1987
Initial Certification · Hull Examination
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1023705
Fire Fighting
Issued 13 June 2000
Resolved
provide proof of inspection for fixed firefighting system before carrying passengers.
Condition: Unknown
Due 16 July 2000
Resolved 15 June 2000
Lifesaving
Issued 13 June 2000
Resolved
Replace retroreflective tape on childrens lifejackets.
Condition: Unknown
Due 1 July 2000
Resolved 15 June 2000
Electrical
Issued 13 June 2000
Resolved
Install metal wire supports in engine room - not to exceed 24 inches apart.
Condition: Unknown
Due 1 July 2000
Resolved 25 July 2000
Lifesaving
Issued 15 June 1999
Resolved
REPLACE OR PROVIDE EXPIRATION DOCUMENTATION FOR EPIRB HYDROSTATIC RELEASE.
Condition: Unknown
Due 15 June 1999
Resolved 15 June 1999
Construction/Loadline
Issued 15 June 1999
Resolved
PROVE PROPER OPERATION OF BILGE PUMP INDICATOR LIGHT.
Condition: Unknown
Due 15 June 1999
Resolved 15 June 1999
Documentation
Issued 15 June 1999
Resolved
PROVIDE CURRENT FCC SAFETY ACT CERTIFICATE.
Condition: Unknown
Due 15 June 1999
Resolved 15 June 1999
Construction/Loadline
Issued 21 December 1998
Resolved
Vessel drydock due on 18SEP98. Drydock actually occured on 21DEC98. MIDR formatted for MV case.
Condition: Unknown
Due 21 December 1998
Resolved 6 January 1999
Construction/Loadline
Issued 18 September 1996
Resolved
REPAIR BLISTERS ON BOTTOM OF HULL AND PROVIDE MSO CHARLESTON WITH MANUFACTURER'S HULL EVALUATION REPORT.
Condition: Unknown
Due 18 September 1996
Resolved 18 September 1996
Construction/Loadline
Issued 18 September 1996
Resolved
REPAIR CRACKS IN FIBERGLASS IN THE FORWARD CABIN AS MARKED BY THE INSPECTOR.
Condition: Unknown
Due 18 September 1996
Resolved 18 September 1996
Lifesaving
Issued 19 June 1996
Resolved
REPLACE THE YELLOW PENDANT AND INTERIOR PERIPHERY LINES AND THE ORANGE DISTRESS MARKER LINE WITH BLACK ULTRAVIOLET RESISTANT FLOTATION LINE.
Condition: Unknown
Due 19 June 1996
Resolved 19 June 1996
Engineering
Issued 12 July 1995
Resolved
REPLACE FRESH WATER COOLING HOSES WITH USCG APPROVED, WIRE REINFORCED HOSES.
Condition: Unknown
Due 12 July 1995
Resolved 12 July 1995
Construction/Loadline
Issued 26 June 1992
Resolved
PROVIDE OPERABLE HAND BILGE PUMP WITH HOSE OF SUITABLE LENGTH._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 30 July 1992
Resolved 30 July 1992
Lifesaving
Issued 26 June 1992
Resolved
VESSEL IS RESTRICKTED TO 13 TOTAL PERSONS UNTIL ONE ADDITION TYPE I PFD IS PROVIDED._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 30 July 1992
Resolved 30 July 1992
Lifesaving
Issued 26 June 1992
Resolved
PROVIDE 3 ADDITIONAL SMOKE SIGNALS._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 30 July 1992
Resolved 30 July 1992
Lifesaving
Issued 26 June 1992
Resolved
REPLACE PENDANT TIES ON LIFE FLOAT WITH SUITABLE BREAKAWAY MATERIAL._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 30 July 1992
Resolved 30 July 1992
Lifesaving
Issued 26 June 1992
Resolved
APPLY 4 STRIPS OF RETROFLECTIVE MATERIAL TO LIFE RING._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 30 July 1992
Resolved 30 July 1992
Navigation
Issued 21 June 1990
Resolved
INSTALL APPROVED NAVIGATIONAL LIGHTS.
Condition: Unknown
Due 21 June 1990
Resolved 21 June 1990
Fire Fighting
Issued 21 June 1990
Resolved
PROVIDE EVIDENCE OF PROPER SERVICING OF FIRE EXTINGUISHERS.
Condition: Unknown
Due 21 June 1990
Resolved 21 June 1990
Fire Fighting
Issued 21 June 1990
Resolved
PROVIDE APPROVED BRACKETS FOR FIRE EXTINGUISHERS.
Condition: Unknown
Due 21 June 1990
Resolved 21 June 1990
Engineering
Issued 21 June 1990
Resolved
PROVIDE NEW TRANSMISSION OIL LINE AND PROVIDE CHAFE PROTEDTION
Condition: Unknown
Due 21 June 1990
Resolved 21 June 1990
Construction/Loadline
Issued 21 June 1990
Resolved
FILL HOLES IN FOREDECK WHERE EQUIPMENT HAS BEEN REMOVED.
Condition: Unknown
Due 21 June 1990
Resolved 21 June 1990
Engineering
Issued 21 June 1990
Resolved
REPLACE FITTING ON CLUTCH CONTROL CABLE CLAMP.
Condition: Unknown
Due 21 June 1990
Resolved 21 June 1990
Navigation
Issued 21 June 1990
Resolved
INSTALL ADDITIONAL BOLD IN CYLINDER MOUNT IN WAY OF STEERING.
Condition: Unknown
Due 21 June 1990
Resolved 21 June 1990
Lifesaving
Issued 21 June 1990
Resolved
PROVIDE 1 ADDITIONAL CHILDREN'S PFD.
Condition: Unknown
Due 21 June 1990
Resolved 21 June 1990
Documentation
Issued 25 June 1987
Resolved
PROVIDE ON BOARD THE VESSEL THE SAFETY RADIOTELEPHONY CERTIFICATE AND THE STATION LICENSE.
Condition: Unknown
Due 25 June 1987
Resolved 25 June 1987