Records from 2001 to 2009. Most recent: inspection, 16 April 2009.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 13
16 April 2009
Drydock Exam · Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3453372
29 April 2008
Drydock Exam · Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3194927
12 July 2007
Deficiency Check
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 2992636
2 May 2007
Hull Examination · Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2916235
5 June 2006
COI Inspection
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 2671085
12 June 2005
Annual Inspection · Hull Examination
Physical examination · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 2389055
21 June 2004
Deficiency Check
Physical examination · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 2106399
19 May 2004
Annual Inspection · Hull Examination
Physical examination · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 2072551
13 June 2003
Re-Inspection · Hull Examination
Physical examination · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 1810298
2 July 2002
Deficiency Check
Physical examination · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 1640192
3 June 2002
Deficiency Check
Physical examination · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 1626706
18 May 2002
Hull Examination · Re-Inspection
Physical examination · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 1623662
5 May 2001
Hull Examination · COI Inspection · Deficiency Check
Physical examination · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 1391595
Stability › Watertight Integrity › General
Issued 5 June 2006
Resolved
Repair torn handholds and buoyancy tube seams.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 17 June 2006
Resolved 12 July 2007
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 5 June 2006
Resolved
Repair ring buoy light. Light not working.
Condition: Unknown
Due 5 June 2006
Resolved 5 June 2006
Resolution: Changed battery & check light, sat.
Documentation › Certificates/Documents › Certificate of Number (state)
Issued 5 June 2006
Resolved
Provide evidence of Alaska Registration certificate.
Condition: Unknown
Due 5 June 2006
Resolved 5 June 2006
Resolution: Found sticker on inflatable boat, 2007 sticker, sat. Registration papers not onboard.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Number
Issued 19 May 2004
Resolved
Vessel had two B-I fire extinguishers. As per, Memo 16711 of 28JAN94 the vessel is required to have one B-II portable fire extinguisher if the vessel carries over six gallon of fuel. LEGACY COMPONENT DESC: Number
Condition: Unknown
Action required: 705 - Other - as specified
Due 25 June 2004
Resolved 20 June 2004
Construction/Loadline › Hull › Stiffener
Issued 19 May 2004
Resolved
Repair four fractures found IAW of transom support. Provide digital pictures to [name withheld] via electronic means of the repair process. Upon return to Juneau contact MSO Juneau to verify repairs.
Condition: Unknown
Action required: 705 - Other - as specified
Due 25 June 2004
Resolved 20 June 2004
Construction/Loadline › Hull
Issued 13 June 2003
Resolved
Repair (6) delaminations pointed out during hull exam, (1) bow tube tear, & (2) torn tube connection straps. LEGACY COMPONENT DESC: Hull Plating
Condition: Unknown
Due 16 June 2003
Resolved 16 June 2003
Resolution: Email letter and pictures attesting to all repairs completed satisfactory. Disc on file repairs done.
Deck/Cargo › Mooring/Anchoring
Issued 18 May 2002
Resolved
Provide at least 150' anchor line. LEGACY COMPONENT DESC: Anchor Rope
Action required: 705 - Other - as specified
Due 18 May 2002
Resolved 3 June 2002
Communications › Radio Communications
Issued 18 May 2002
Resolved
Provide EPIRB, category I, or present waiver letter granted by [name withheld] COMPONENT DESC: EPIRB
Action required: 705 - Other - as specified
Due 18 June 2002
Resolved 7 June 2002
Resolution: Exemption Letter granted by OCMI.
Documentation
Issued 5 May 2001
Resolved
PROVIDE DOCUMENTATION OF CREW ENROLLMENT WITH DRUG-TESTING CONSORTIUM.
Condition: Unknown
Due 24 May 2001
Resolved 24 May 2001
Documentation
Issued 5 May 2001
Resolved
PROVIDE FCC STATION LICENSE, FCC FORM 824 CERTIFICATE, AND MARINE RADIO OPERATOR'S PERMIT.
Condition: Unknown
Due 24 May 2001
Resolved 24 May 2001
Documentation
Issued 5 May 2001
Resolved
OBTAIN AND AFFIX STATE REGISTRATION STICKERS AND AK NUMBERS.
Condition: Unknown
Due 24 May 2001
Resolved 24 May 2001
Fire Fighting
Issued 5 May 2001
Resolved
MOUNT SECOND B-I FIRE EXTINGUISHER PRIOR TO CARRYING PASSENGERS.
Condition: Unknown
Due 24 May 2001
Resolved 24 May 2001