MAURY USCG vessel records
← All vessels

SNOW GOOSE 2

SNOW GOOSE 2 is a 1987 passenger vessel (inspected). The Coast Guard has recorded 11 inspections since 2016, most recently in March 2026, along with 15 deficiencies.

Records from 2016 to 2026. Most recent: inspection, 19 March 2026.

Built
1987
Last inspected
19 March 2026
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Identity

WDC4910
284342
Flag
UNITED STATES
Maury page id
psix-284342

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspections, by type

Years with a record 11 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. The counts in the strip above are the same counts; this table splits the inspections by the kind of activity recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Documentation record

Registered dimensions (L × B × D)50.0 ft × 16.7 ft × 5.9 ft
Registered tonnagegross 33 / net 26
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderEAST BAY BOATWORKS · HARKERS ISLAND, NC, UNITED STATES · built 1987
Hull materialWood
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portBYRAM RIVER, CT
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 11 February 2026 · expires 31 January 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it33 - Simplified, Gross Ton
26 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report

A report is not offered for this hull. Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 11

19 March 2026 Annual Inspection · Administrative Inspection · Deficiency Check
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 8328853
13 March 2025 Hull Examination · Annual Inspection · Internal Structural Exam
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 8091671
5 April 2024 Annual Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7881904
21 March 2023 Deficiency Check · Annual Inspection · Hull Examination · Internal Structural Exam
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7653418
16 March 2022 COI Inspection · Deficiency Check
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7412976
29 March 2021 Annual Inspection · Deficiency Check · Internal Structural Exam · Hull Examination
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7164866
23 June 2020 Annual Inspection · Drydock Extension
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6965218
21 March 2019 Annual Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6646919
22 March 2018 Annual Inspection · Hull Examination · Internal Structural Exam · Administrative Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6376971
15 March 2017 COI Inspection · Deficiency Check
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6105502
25 April 2016 Internal Structural Exam · Hull Examination · Annual Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 5863590

Deficiency record · 15

01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 2 April 2026 Resolved
Vessel is required to have FCC station license certificate onboard the vessel. Operator didn't have onboard.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 May 2026
Resolved 23 May 2026
Resolution: Vsl has current station license certificate onboard.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 2 April 2026 Resolved
FCC safety certificate has expired. Renew safety certificate.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 May 2026
Resolved 23 May 2026
Resolution: Vsl has current safety certificate onboard.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 30 March 2023 Resolved
Repair bilge line in house compartment that enters from forepeak. [name withheld] a hole and water coming in when pump in forepeak came on.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 April 2023
Resolved 31 March 2023
Resolution: repaired
04 - Emergency Systems › N/A - No Subsystem › Water level indicator
Issued 30 March 2023 Resolved
Repair/replace forepeak bilge high level alarm. MI witnessed NO audible/visual signal when activated.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 April 2023
Resolved 30 March 2023
Resolution: repaired
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 16 March 2022 Resolved
5 Adult PFD's of the total 39 were worn and destroyed. Vessel must operate with a total passenger capacity of 34 until satisfactory PFD's are provided.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 April 2022
Resolved 4 April 2022
Resolution: provided
09 - Working and Living Conditions › 092 - Working Conditions › Guards - fencing around dangerous machinery parts
Issued 16 March 2022 Resolved
MDE requires a cover or guard around rotating gears and belt area.
Condition: Design Flaw
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 April 2022
Resolved 4 April 2022
Resolution: provided
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 16 March 2022 Resolved
A metal bowl must be installed under the fuel oil water separator.
Condition: Design Flaw
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 April 2022
Resolved 4 April 2022
Resolution: provided
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 8 April 2021 Resolved
Life Float painter line was deteriorated and sheared upon inspection.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 13 April 2021
Resolution: new provided
11 - Life Saving Appliances › N/A - No Subsystem › On board training and instructions
Issued 8 April 2021 Resolved
Vessel couldn't perfrom drills due to deck hand not showing up. Completed drills in presence of CG MI.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 13 April 2021
Resolution: completed sat
11 - Life Saving Appliances › N/A - No Subsystem › Operation of Life Saving Appliances
Issued 8 April 2021 Resolved
Float Light for LF did not operate properly. Install working light attached to LF.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 13 April 2021
Resolution: installed
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 8 April 2021 Resolved
EPRIB hydrostatic release was expired. Installed valiad hydrostatic release for EPRIB.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 13 April 2021
Resolution: installed
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 23 June 2020 Resolved
Bilge high level alarm in #1 void (collision space) not operable.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 23 June 2020
Resolution: Owner had spare on board and replaced it.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 23 June 2020 Resolved
Display stability letter.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Resolved 23 June 2020
Resolution: O/O posted it at the operating station.
Lifesaving › Lifefloat › Netting
Issued 15 March 2017 Resolved
Netting line was worn and needs to be replaced
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 April 2017
Construction/Loadline › Penetrations › Gasket
Issued 25 April 2016 Resolved
Replace the clamps on the flex hose attaching the shaft log to the shaft packing.
Condition: Improper/Lack of Maintenance
Due 28 April 2017
Resolved 12 April 2017

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.