Records from 2016 to 2026. Most recent: inspection, 19 March 2026.
Documentation record
Registered dimensions (L × B × D)50.0 ft × 16.7 ft × 5.9 ft
Registered tonnagegross 33 / net 26
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderEAST BAY BOATWORKS · HARKERS ISLAND, NC, UNITED STATES · built 1987
Hull materialWood
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portBYRAM RIVER, CT
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 11 February 2026 · expires 31 January 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it33 - Simplified, Gross Ton
26 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 11
19 March 2026
Annual Inspection · Administrative Inspection · Deficiency Check
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 8328853
13 March 2025
Hull Examination · Annual Inspection · Internal Structural Exam
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 8091671
5 April 2024
Annual Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7881904
21 March 2023
Deficiency Check · Annual Inspection · Hull Examination · Internal Structural Exam
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7653418
16 March 2022
COI Inspection · Deficiency Check
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7412976
29 March 2021
Annual Inspection · Deficiency Check · Internal Structural Exam · Hull Examination
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7164866
23 June 2020
Annual Inspection · Drydock Extension
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6965218
21 March 2019
Annual Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6646919
22 March 2018
Annual Inspection · Hull Examination · Internal Structural Exam · Administrative Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6376971
15 March 2017
COI Inspection · Deficiency Check
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6105502
25 April 2016
Internal Structural Exam · Hull Examination · Annual Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 5863590
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 2 April 2026
Resolved
Vessel is required to have FCC station license certificate onboard the vessel. Operator didn't have onboard.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 May 2026
Resolved 23 May 2026
Resolution: Vsl has current station license certificate onboard.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 2 April 2026
Resolved
FCC safety certificate has expired. Renew safety certificate.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 May 2026
Resolved 23 May 2026
Resolution: Vsl has current safety certificate onboard.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 30 March 2023
Resolved
Repair bilge line in house compartment that enters from forepeak. [name withheld] a hole and water coming in when pump in forepeak came on.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 April 2023
Resolved 31 March 2023
Resolution: repaired
04 - Emergency Systems › N/A - No Subsystem › Water level indicator
Issued 30 March 2023
Resolved
Repair/replace forepeak bilge high level alarm. MI witnessed NO audible/visual signal when activated.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 April 2023
Resolved 30 March 2023
Resolution: repaired
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 16 March 2022
Resolved
5 Adult PFD's of the total 39 were worn and destroyed. Vessel must operate with a total passenger capacity of 34 until satisfactory PFD's are provided.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 April 2022
Resolved 4 April 2022
Resolution: provided
09 - Working and Living Conditions › 092 - Working Conditions › Guards - fencing around dangerous machinery parts
Issued 16 March 2022
Resolved
MDE requires a cover or guard around rotating gears and belt area.
Condition: Design Flaw
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 April 2022
Resolved 4 April 2022
Resolution: provided
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 16 March 2022
Resolved
A metal bowl must be installed under the fuel oil water separator.
Condition: Design Flaw
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 April 2022
Resolved 4 April 2022
Resolution: provided
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 8 April 2021
Resolved
Life Float painter line was deteriorated and sheared upon inspection.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 13 April 2021
Resolution: new provided
11 - Life Saving Appliances › N/A - No Subsystem › On board training and instructions
Issued 8 April 2021
Resolved
Vessel couldn't perfrom drills due to deck hand not showing up. Completed drills in presence of CG MI.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 13 April 2021
Resolution: completed sat
11 - Life Saving Appliances › N/A - No Subsystem › Operation of Life Saving Appliances
Issued 8 April 2021
Resolved
Float Light for LF did not operate properly. Install working light attached to LF.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 13 April 2021
Resolution: installed
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 8 April 2021
Resolved
EPRIB hydrostatic release was expired. Installed valiad hydrostatic release for EPRIB.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 13 April 2021
Resolution: installed
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 23 June 2020
Resolved
Bilge high level alarm in #1 void (collision space) not operable.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 23 June 2020
Resolution: Owner had spare on board and replaced it.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 23 June 2020
Resolved
Display stability letter.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Resolved 23 June 2020
Resolution: O/O posted it at the operating station.
Lifesaving › Lifefloat › Netting
Issued 15 March 2017
Resolved
Netting line was worn and needs to be replaced
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 April 2017
Construction/Loadline › Penetrations › Gasket
Issued 25 April 2016
Resolved
Replace the clamps on the flex hose attaching the shaft log to the shaft packing.
Condition: Improper/Lack of Maintenance
Due 28 April 2017
Resolved 12 April 2017