Records from 1987 to 2024. Most recent: inspection, 17 December 2024.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 41
17 December 2024
Drydock Exam · Internal Structural Exam · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8048643
3 April 2018
Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6403031
21 June 2016
Internal Structural Exam · Hull Examination · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 5913992
6 June 2006
Annual Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 2718071
22 May 2006
Hull Examination
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 2673062
2 February 2005
Deficiency Check · Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 2285837
13 September 2004
Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 2194389
23 June 2004
Hull Examination
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 2107335
4 November 2003
Deficiency Check
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 1942449
9 September 2003
Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 1900528
18 June 2002
Deficiency Check · COI Inspection · Hull Examination
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 1632410
20 June 2001
Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1467326
18 October 2000
Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1055920
19 September 2000
Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 822080
27 June 2000
Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1420592
6 August 1999
Administrative
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1111464
17 June 1999
COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1397280
13 August 1998
Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1381314
2 July 1998
Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1368791
21 July 1997
Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1445272
2 June 1997
Type not recorded
No type recorded · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 83360
27 June 1996
COI Inspection · Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1405932
18 April 1996
Drydock Extension
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1088110
20 June 1995
Re-Inspection · Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1419446
10 July 1994
Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 865272
5 July 1994
Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 861889
15 March 1994
Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1166117
22 June 1993
COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1156197
20 April 1993
Administrative
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1150531
25 August 1992
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1260184
15 July 1992
Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1258383
10 June 1992
Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 952761
18 September 1991
Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1310782
20 June 1991
Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 944093
14 November 1990
Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1214937
22 June 1990
COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1233907
5 April 1989
Hull Examination · Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 890973
30 November 1988
Drydock Extension
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1212005
8 June 1988
Re-Inspection · Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 891147
17 November 1987
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1332805
26 June 1987
Initial Certification · Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1336345
Construction/Loadline › Penetrations › Bottom Plug Packing
Issued 21 June 2016
No resolution recorded
Rudder stop needs packing/welding port and starboard
Condition: Invalid
Action required: 705 - Other - as specified
Due 21 June 2016 — due date passed with no resolution recorded
Construction/Loadline › Penetrations › Valve Flange
Issued 21 June 2016
No resolution recorded
Renew 1 inch ball valve
Condition: Invalid
Action required: 705 - Other - as specified
Due 21 June 2016 — due date passed with no resolution recorded
Construction/Loadline › Structures › Superstructure
Issued 21 June 2016
No resolution recorded
Renew all ladders going into spaces.
Condition: Invalid
Action required: 705 - Other - as specified
Due 21 June 2016 — due date passed with no resolution recorded
Accommodation/Occupational Safety › Occupational Safety › Hand Grab
Issued 21 June 2016
No resolution recorded
Repair handrails
Condition: Invalid
Action required: 705 - Other - as specified
Due 21 June 2016 — due date passed with no resolution recorded
Construction/Loadline › Hull › Hull Plating
Issued 21 June 2016
No resolution recorded
Renew delaminated decking under salon space open for USCG.
Condition: Invalid
Action required: 705 - Other - as specified
Due 21 June 2016 — due date passed with no resolution recorded
Construction/Loadline › Hull › Hull Plating
Issued 21 June 2016
No resolution recorded
Renew soft decking on vessel
Condition: Invalid
Action required: 705 - Other - as specified
Due 21 June 2016 — due date passed with no resolution recorded
Communications › Radio Communications › EPIRB
Issued 6 June 2006
Resolved
Repair EPIRB Antenna & activation tab.
Action required: 701 - Prior to carriage of passengers/cargo
Due 8 June 2006
Resolved 8 June 2006
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 6 June 2006
Resolved
Provide proof of enrollment in a Drug Consortium and/or Program.
Action required: 701 - Prior to carriage of passengers/cargo
Due 8 June 2006
Resolved 8 June 2006
Communications › Radio Communications › VHF Radiotelephone
Issued 6 June 2006
Resolved
Obtain FCC Safety Cert. or the Equivalent from DOD.
Action required: 705 - Other - as specified
Due 6 July 2006
Resolved 18 July 2006
Personnel › Certificates/Documents/Licenses › License, Operator
Issued 6 June 2006
Resolved
Provide proof of FCC Radio Operator Permit.
Action required: 705 - Other - as specified
Due 6 July 2006
Resolved 18 July 2006
Navigation › Piloting/Steering › Tide/Tidal Current Tables
Issued 6 June 2006
Resolved
Obtain 2006 Tide and Current Tables.
Action required: 705 - Other - as specified
Due 6 July 2006
Resolved 18 July 2006
Lifesaving › Hand Flares › Expired
Issued 6 June 2006
Resolved
Obtain (6) orange smoke flares, those onboard noted to be expired.
Action required: 705 - Other - as specified
Due 6 July 2006
Resolved 18 July 2006
Communications › Radio Communications › VHF Radiotelephone
Issued 6 June 2006
Resolved
Post Emergency Broadcast Placard next to VHF Radio installation.
Action required: 705 - Other - as specified
Due 6 July 2006
Resolved 18 July 2006
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 6 June 2006
Resolved
Post "Crew Only" placard at ladder to upper deck.
Action required: 705 - Other - as specified
Due 6 July 2006
Resolved 18 July 2006
Engineering › Bilge Water Management System › Interface Detector
Issued 6 June 2006
Resolved
Provide seperate visual and audio indicators for each space required to have a high level alarm.
Action required: 705 - Other - as specified
Due 6 July 2006
Resolved 18 July 2006
Construction/Loadline › Hull › Side Shell
Issued 6 June 2006
Resolved
Make permanent repairs to the on deck leakage iwo the fish hold.
Action required: 705 - Other - as specified
Due 6 July 2006
Resolved 18 July 2006
Construction/Loadline › Hull › Hull Plating
Issued 22 May 2006
Resolved
Repair hull penetrations in forward accommodation space as original.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Resolved 6 June 2006
Construction/Loadline › Hull › Hull Plating
Issued 22 May 2006
Resolved
Make proper repairs blisters on the exterior of the hull as marked (7) starboard, (2) port.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 6 June 2006
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 2 February 2005
Resolved
Renew Certificate of Documentation. 46 CFR 67.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 2 March 2005
Resolved 21 April 2005
Documentation › Certificates/Documents › FCC SSL
Issued 2 February 2005
Resolved
Obtain required FCC Station License and Safety Certificate. 47 CFR 80.13.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Due 2 March 2005
Resolved 21 April 2005
Documentation › Certificates/Documents › Stability Letter
Issued 2 February 2005
Resolved
Post stability letter. 46 CFR 176.306.
Condition: Unknown
Action required: 705 - Other - as specified
Due 2 March 2005
Resolved 21 April 2005
Documentation › Safety/Response Plans/Programs › Waste Management Plan
Issued 2 February 2005
Resolved
Post waste management plan. 33 CFR 151.57.
Condition: Unknown
Action required: 705 - Other - as specified
Due 2 March 2005
Resolved 21 April 2005
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 2 February 2005
Resolved
Perform required hydrostatic test and servicing of Fixed Fire Fighting equipment. 46 CFR 176.810.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 2 March 2005
Resolved 21 April 2005
Documentation › Logs/Records › Logbook (official)
Issued 2 February 2005
Resolved
Provide evidence of training or provide training logbook and required logs. 46 CFR 185.420.
Condition: Unknown
Action required: 705 - Other - as specified
Due 2 March 2005
Resolved 21 April 2005
Documentation › Manifests/Lists › Emergency Checkoff List
Issued 2 February 2005
Resolved
Post emergency instruction list. 46 CFR 185.510.
Condition: Unknown
Action required: 705 - Other - as specified
Due 2 March 2005
Resolved 21 April 2005
Navigation › Piloting/Steering › Tide/Tidal Current Tables
Issued 2 February 2005
Resolved
Obtain updated tide and tidal current tables. 46 CFR 184.420.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 2 March 2005
Resolved 21 April 2005
Lifesaving › Visual Distress Signals (General) › Not on Board
Issued 2 February 2005
Resolved
Obtain 6 day and 6 night visual distress signals. 46 CFR 180.68.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Due 2 March 2005
Resolved 21 April 2005
Communications › Radio Communications › EPIRB
Issued 2 February 2005
Resolved
Install EPIRB in float-free arrangement.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 2 March 2005
Resolved 21 April 2005
Stability › Watertight Integrity › General
Issued 2 February 2005
Resolved
Submit repair proposal for damage to starboard bulkhead. 46 CFR 176.802.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Due 2 March 2005
Resolved 21 April 2005
Stability › Watertight Integrity › Weathertight Enclosure
Issued 2 February 2005
Resolved
Renew gasket on main engine space scuttle. 46 CFR 171.124.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Due 2 March 2005
Resolved 21 April 2005
Documentation › Markings/Placards › Capacity Marking
Issued 2 February 2005
Resolved
Mark upper decks for maximum number of passengers per stability letter. 46 CFR 185.602.
Condition: Unknown
Action required: 705 - Other - as specified
Due 2 March 2005
Resolved 21 April 2005
Lifesaving › Lifefloat › Markings
Issued 2 February 2005
Resolved
Clean life float and mark as required. 46 CFR 185.604.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 2 March 2005
Resolved 21 April 2005
Lifesaving › Lifejacket/PFD (General) › Condition
Issued 2 February 2005
Resolved
Replace 4 adult life jackets, and repair 1 child life jacket. 46 CFR 180.71.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 2 March 2005
Resolved 21 April 2005
Documentation › Markings/Placards › Lifejacket Placard
Issued 2 February 2005
Resolved
Post life jacket donning placard. 46 CFR 185.516.
Condition: Unknown
Action required: 705 - Other - as specified
Due 2 March 2005
Resolved 21 April 2005
Lifesaving › Lifebuoys › Stowage
Issued 2 February 2005
Resolved
Replace floating water light bracket for ring life buoy. 46 CFR 180.70.
Condition: Unknown
Action required: 705 - Other - as specified
Due 2 March 2005
Resolved 21 April 2005
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 2 February 2005
Resolved
Renew expired items in first aid kit. 46 CFR 184.710.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 2 March 2005
Resolved 21 April 2005
Communications › Alarms/Indicators › Fire Alarm
Issued 2 February 2005
Resolved
Install smoke detector in forward passenger compartment and main engine space. 46 CFR 176.810.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 2 March 2005
Resolved 21 April 2005
Engineering › Shafting/Propeller Arrangements › Propeller Shaft
Issued 2 February 2005
Resolved
Repair/renew starboard shaft, noted excessive vibration and coupling movement while in operation. 46 CFR 176.804.
Condition: Unknown
Action required: 705 - Other - as specified
Due 2 March 2005
Resolved 21 April 2005
Resolution: Shafting and engine were re-aligned, shaft replacement was not required.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 2 February 2005
Resolved
Install machinery guards over exposed belts in main engine space. 46 CFR 177.960.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 2 March 2005
Resolved 21 April 2005
Communications › Alarms/Indicators › Bilge Alarm
Issued 2 February 2005
Resolved
Repair visual indicator for bilge pump operation, and repair bilge high level audible alarm. 46 CFR 182.530.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 2 March 2005
Resolved 21 April 2005
Documentation › Markings/Placards › Oil Discharge Placard
Issued 2 February 2005
Resolved
Post oil pollution placard in vicinity of bilge pumps switches. 46 CFR 182.530.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 2 March 2005
Resolved 21 April 2005
Construction/Loadline › Hull › Bottom Plating
Issued 23 June 2004
Resolved
Repair area of minor FRP de-lamination in hull in way of port stern tube.
Action required: 705 - Other - as specified
Resolved 24 June 2004
Resolution: Area gound, filled and faired to satisfaction of attending inspector.
Construction/Loadline › Structures › Scuttle
Issued 23 June 2004
Resolved
Replace missing gasket on watertight scuttle leading to machinery space.
Action required: 705 - Other - as specified
Resolved 25 June 2004
Engineering › Shafting/Propeller Arrangements › Stern Tube Lubrication/Sealing
Issued 23 June 2004
Resolved
Replace port and stbd propulsion shaft stern tube sealing boots and clean and lubricate clamping devices.
Action required: 705 - Other - as specified
Resolved 25 June 2004
Engineering › Sea-water System (primary cooling) › Piping
Issued 23 June 2004
Resolved
Repair and make serviceable stbd main propulsion engine sea strainer basket assy.
Action required: 705 - Other - as specified
Resolved 25 June 2004
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 23 June 2004
Resolved
Properly install insulation around port main propulsion exhaust piping where it penetrates the aft machinery space bulkhead.
Action required: 705 - Other - as specified
Resolved 25 June 2004
Construction/Loadline › Penetrations › Valve Flange
Issued 23 June 2004
Resolved
Open, clean and make 2 sewage system overboard valves and the stbd main propulsion engine raw water overboard valve available for visual inspection.
Action required: 705 - Other - as specified
Due 19 July 2004
Resolved 21 April 2005
Documentation › Safety/Response Plans/Programs
Issued 9 September 2003
Resolved
Provide waste management plan as required by 33 CFR 151.57. LEGACY COMPONENT DESC: Waste Management Plan
Action required: 705 - Other - as specified
Due 9 October 2003
Resolved 4 November 2003
Resolution: Owner provided waste management plan.
Documentation › Manifests/Lists
Issued 9 September 2003
Resolved
Provide emergency instruction list as required by 46 CFR 185.510. LEGACY COMPONENT DESC: Muster List/Emergency Instructions
Action required: 705 - Other - as specified
Due 9 October 2003
Resolved 4 November 2003
Resolution: Owner provided emergency instruction list.
Navigation › Piloting/Steering
Issued 9 September 2003
Resolved
Provide CG Light List as required by 46 CFR 184.426. LEGACY COMPONENT DESC: Coast Guard Light List
Action required: 705 - Other - as specified
Due 9 October 2003
Resolved 4 November 2003
Resolution: Owner provided CG Light List as required.
Lifesaving › Lifejacket/PFD (Type I)
Issued 9 September 2003
Resolved
Provide lifejacket donning placard and post same as required by 46 CFR 185.516. LEGACY COMPONENT DESC: Donning Placard
Action required: 705 - Other - as specified
Due 9 October 2003
Resolved 4 November 2003
Resolution: Owner provided lifejacket donning placard.
Accommodation/Occupational Safety › Medical/First Aid
Issued 9 September 2003
Resolved
Provide approved first aid kit as required by 46 CFR 184.710. LEGACY COMPONENT DESC: Kit
Action required: 705 - Other - as specified
Due 9 October 2003
Resolved 4 November 2003
Resolution: Owner provided approved first aid kit.
Electrical › Electric Generation Source (service)
Issued 9 September 2003
Resolved
Provide derating placard for generator as required by 46 CFR 183.320. LEGACY COMPONENT DESC: Derating Placard
Action required: 705 - Other - as specified
Due 9 October 2003
Resolved 4 November 2003
Resolution: Owner provided derating placard for generator.
Fire Fighting › Fixed Gas Fire Extinguishing System
Issued 18 June 2002
Resolved
Prove operation of generator prime mover shutdown upon activation of fixed fire suppression system as required by 46 CFR 181.410 (b) (10).
Due 19 June 2002
Resolved 19 June 2002
Resolution: Witnessed proper operation of shutdown of generator prime mover upon activation of fixed fire suppression system.
Engineering
Issued 20 June 2001
Resolved
INSTALL MACHINERY GUARDS ON MAIN ENGINES AND GENERATOR PULLEYS IAW 46 CFR 177. 960 PRIOR TO 20 JUL01.
Condition: Unknown
Due 20 July 2001
Resolved 5 September 2001
Documentation
Issued 20 June 2001
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 20 July 2001
Resolved 5 September 2001
Accommodation/Occupational Safety
Issued 20 June 2001
Resolved
LABLE EMERGENCY ESCAPE IAW 46 CFR 177. 500 PRIOR TO 20 JUL01.
Condition: Unknown
Due 20 July 2001
Resolved 5 September 2001
Accommodation/Occupational Safety
Issued 20 June 2001
Resolved
MARK UPPER DECK " NO PASSENGERS ALLOWED" IAW 46 CFR 177. 500 PRIOR TO 20 JUL01.
Condition: Unknown
Due 20 July 2001
Resolved 5 September 2001
Accommodation/Occupational Safety
Issued 19 September 2000
Resolved
MAKE REPAIRS TO LEAKS AROUND PORT LIGHTS TO MAKE WATERTIGHT AS REQUIRED BY 46 CFR 176.830
Condition: Unknown
Due 19 September 2000
Resolved 19 September 2000
Navigation
Issued 19 September 2000
Resolved
PROVIDE CURRENT CHARTS AND PUBLICATION AS REQUIRED BY 46 CFR 184.420
Condition: Unknown
Due 19 September 2000
Resolved 19 September 2000
Lifesaving
Issued 20 June 1995
Resolved
REPAIR OR RENEW LIFE RING,
Condition: Unknown
Due 20 July 1995
Resolved 31 July 1995
Documentation
Issued 5 July 1994
Resolved
PROVE COMPLIANCE WITH RANDOM DRUG TESTING IAW 46 CFR 16.
Condition: Unknown
Due 5 July 1994
Resolved 5 July 1994
Engineering
Issued 22 June 1993
Resolved
PROVE OPERATION OF INSTALLED M.D.E. RPM GUAGES.
Condition: Unknown
Due 14 July 1993
Resolved 14 July 1993
Fire Fighting
Issued 15 July 1992
Resolved
PROVIDE WASTE MANAGEMENT PLAN.
Condition: Unknown
Due 4 August 1992
Resolved 22 July 1992
Construction/Loadline
Issued 15 July 1992
Resolved
HARD PIPE (3) 12VDC BILGE PUMP (1) SHORT FLEX HOSE IS ALLOWED.
Condition: Unknown
Due 15 July 1992
Resolved 15 July 1992
Lifesaving
Issued 15 July 1992
Resolved
PROVIDE (3) SMOKE ORANGE FLARES.
Condition: Unknown
Due 15 July 1992
Resolved 15 July 1992
Navigation
Issued 15 July 1992
Resolved
PROVIDE AND INSTALL MAST HEAD LIGHT IN ACCORDANCE WITH 72 COL REGS (3 MILE RANGE).
Condition: Unknown
Due 15 July 1992
Resolved 15 July 1992
Navigation
Issued 15 July 1992
Resolved
PROVIDE PROPER OPERATIONS PORT RUNNING AND STERN LIGHT.
Condition: Unknown
Due 15 July 1992
Resolved 15 July 1992
Accommodation/Occupational Safety
Issued 15 July 1992
Resolved
TIGHTEN BOW RAILS AND INSTALL MISSING SCREWS.
Condition: Unknown
Due 15 July 1992
Resolved 15 July 1992
Engineering
Issued 15 July 1992
Resolved
PROVE PROPER OPERATION PORT EMERGENCY FUEL SHUTOFF.
Condition: Unknown
Due 15 July 1992
Resolved 15 July 1992
Engineering
Issued 15 July 1992
Resolved
LEAD LINE 01 FRP LINE GENERATOR BATTERY BOX.
Condition: Unknown
Due 15 July 1992
Resolved 15 July 1992
Documentation
Issued 15 July 1992
Resolved
PROVIDE EMERGENCY CHECKOFF LIST.
Condition: Unknown
Due 4 August 1992
Resolved 22 July 1992
Lifesaving
Issued 20 June 1991
Resolved
PROVIDE ONE ADDITIONAL ORANGE AND SIX RED FLARES._x001C_
Condition: Unknown
Due 20 June 1991
Resolved 20 June 1991
Lifesaving
Issued 20 June 1991
Resolved
RENEW RING BUOY WITH -60- FEET OF LINE ATTACHED._x001C_
Condition: Unknown
Due 20 June 1991
Resolved 20 June 1991
Lifesaving
Issued 20 June 1991
Resolved
RENEW LIFE FLOAT WITH -100- FOOT PAINTER. LIFE FLOAT SHALL BE AT LEAST 12-MAN CAPACITY.
Condition: Unknown
Due 20 June 1991
Resolved 20 June 1991
Navigation
Issued 20 June 1991
Resolved
PROVIDE AND INSTALL BELL MADE OF CORROSION-RESISTANT MATERIAL AND DESIGNED TO GIVE A CLEAR TONE. THE DIAMETER OF THE MOUTH OF THE BELL SHALL BE NOT LESS THAN 200MM(7.9 INCHES)._x001C_
Condition: Unknown
Due 20 June 1991
Resolved 20 June 1991
Electrical
Issued 20 June 1991
Resolved
PROPERLY SUPPORT ALL ELECTRICAL WIRING EVERY -18- INCHES AND RE-ROUTE WIRING TO PREVENT IT FROM BEING IN THE BILGE AREA._x001C_
Condition: Unknown
Due 20 June 1991
Resolved 20 June 1991
Lifesaving
Issued 20 June 1991
Resolved
RENEW ONE ADDITIONAL ADULT LIFE PRESERVER AND RENEW RETROREFLECTIVE TO SEVEN LIFE PRESERVERS._x001C_
Condition: Unknown
Due 20 June 1991
Resolved 20 June 1991
Accommodation/Occupational Safety
Issued 20 June 1991
Resolved
PROVIDE MEANS TO LOCK SEWAGE DISCHARGE VALVE IN CLOSED POSITION._x001C_
Condition: Unknown
Due 20 June 1991
Resolved 20 June 1991
Engineering
Issued 20 June 1991
Resolved
THE METALLIC SECTIONS OF DIESEL FUEL FILLING PIPE SEPARATED BY FLEXIBLE HOSE SHALL BE JOINED BY A CONDUCTOR FOR PROTECTION AGAINST METALLIC SPARK WHEN FILLING._x001C_
Condition: Unknown
Due 20 June 1991
Resolved 20 June 1991
Engineering
Issued 20 June 1991
Resolved
REMOVE PETCOCKS FROM FUEL FILTERS AND INSTALL PIPE PLUGS._x001C_
Condition: Unknown
Due 20 June 1991
Resolved 20 June 1991
Electrical
Issued 20 June 1991
Resolved
A VOLTMETER AND AMMETER SHALL BE PROVIDED FOR A/C GENERATOR. ALSO, A MEANS FOR MEASURING FREQUENCY SHALL BE PROVIDED._x001C_
Condition: Unknown
Due 20 June 1991
Resolved 20 June 1991
Construction/Loadline
Issued 20 June 1991
Resolved
PROVIDE CHAIN OR OTHER SUITABLE MATERIAL ATTACHED STERN COMPARTMENT WATERTIGHT HATCH COVER TO PREVENT IT'S LOSS FROM IT'S FRAME._x001C_
Condition: Unknown
Due 20 June 1991
Resolved 20 June 1991
Fire Fighting
Issued 22 June 1990
Resolved
PROVE PROPER OPERATION OF ENTIRE FIXED HALON SYSTEM IN ENGINE ROOM INCLUDING MANUAL OPERATION AND AUTOMATIC MDE AND GENERATOR SHUTDOWN DEVICES
Condition: Unknown
Due 22 June 1990
Resolved 22 June 1990
Documentation
Issued 26 June 1987
Resolved
PROVIDE VALID CERTIFICATE OF DOCUMENTATION.
Condition: Unknown
Due 26 June 1987
Resolved 26 June 1987