← All vessels
EMINE
EMINE is a 1981 freight ship. The Coast Guard has recorded 28 inspections since 1987, most recently in July 2011, along with 50 deficiencies and 2 operational controls.
Records from 1987 to 2011. Most recent: inspection, 27 July 2011.
- Built
- 1981
- Last inspected
- 27 July 2011
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 50 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
8222575 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
9HWO8
284513
Flag
MALTA
—
Maury page id
psix-284513
Inspections, by type
…with no type recorded19
Years with a record
14 calendar years (1987–2011)
The 28 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
This record may be incomplete: the most recent inspection recorded for this vessel was 15 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 1981.
Documentation record
Tonnage as PSIX records it9237 - Convention (Subpart B), Net Ton
16502 - Convention (Subpart B), Gross Ton
25560 - Dead Weight, Ton
33315 - Displacement, Ton
16502 - Convention (Subpart B), Gross Ton
25560 - Dead Weight, Ton
33315 - Displacement, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 28
27 July 2011
PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4084160
2 February 2010
MARPOL Annex VI Survey · MARPOL Annex I Examination · Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3668587
5 September 2008
Deficiency Check
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 3312732
17 January 2008
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3132021
11 January 2008
Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3124238
22 May 2005
NPV Safety Exam · ISPS II Exam · MARPOL Annex I Examination · Ballast Water Examination · MARPOL Annex V Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2364550
20 May 2005
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2370411
29 March 2004
Special Interest Vessel
Type not classified · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 2034581
20 March 2004
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2030874
15 March 2004
Annual Inspection · MARPOL Annex V Examination · MARPOL Annex I Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 2024893
14 March 2004
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 2024132
4 June 2002
Ballast Water Examination · Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1626346
22 January 2002
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1481778
22 January 2002
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1485248
27 August 2001
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 293306
14 March 2001
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 288174
6 July 2000
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 279671
10 March 2000
Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 275480
22 September 1999
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 432592
19 July 1999
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 430895
21 February 1999
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 425804
8 February 1999
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 425738
15 October 1998
Type not recorded
No type recorded · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 421407
27 May 1998
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 416212
17 November 1997
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 409875
16 May 1996
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 390593
9 April 1991
Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 342755
11 August 1987
Type not recorded
No type recorded · COTP HOUSTON · USCG Heartland District (CGD-H) · Activity 317785
Deficiency record · 50
Electrical › Electric Generation Source (service) › Panelboard
Issued 11 January 2008
Resolved
Vessel main switch board in the engine control room has two open spots in panel. Vessel needs to replace all open spots on the main switch board with new banks.
Fire Fighting › Emergency Fire Pumps › Arrangement
Issued 11 January 2008
Resolved
On emergency fire pump switch panel two lights are out. Vessel needs to replace broken lights on emergency fire pump siwtch board.
Fire Fighting › Combustible Materials
Issued 4 June 2002
Resolved
There is excessive oil on engine room machinery and in containments.
Engineering › Diesel Engine (propulsion-direct drive)
Issued 4 June 2002
Resolved
Main engine cylinders No.1, No.3 and No.5 have minor leaks on the high pressure fuel lines. LEGACY COMPONENT DESC: Injector (fuel injection)
Engineering › Diesel Engine (propulsion-direct drive)
Issued 4 June 2002
Resolved
Main engine cylinder No. 4 exhaust valve has a minor leak. LEGACY COMPONENT DESC: Valve
Engineering › Diesel Engine (propulsion/auxiliary-electric)
Issued 4 June 2002
Resolved
No.2 generator No. 5 cylinder injector has a minor fuel oil leak. LEGACY COMPONENT DESC: Injector (fuel injection)
Engineering › Diesel Engine (propulsion/auxiliary-electric)
Issued 4 June 2002
Resolved
No.3 generator auto air start solenoid is disconnected.
Engineering › Diesel Engine (propulsion/auxiliary-electric)
Issued 4 June 2002
Resolved
Emergency generator cylinders No.1, No.2 and No.3 head gaskets are leaking. LEGACY COMPONENT DESC: Cylinder Head
Electrical
Issued 14 March 2001
Resolved
PROVIDE ELECTRICAL RUBBER MAT IN FRONT OF CONTROL SWITCHBOARD. PRIOR TO ENTERING U.S. WATERS PROVIDE STATEMENT FROM MASTER TO LOCAL OCMI.
Accommodation/Occupational Safety
Issued 14 March 2001
Resolved
REPAIR/REPLACE DOOR CLOSING DEVICES OF ENGINE ROOM EMERGENCY EXIT DOOR AND CONTROL ROOM DOORS. PRIOR TO ENTERING TO U.S. WATERS PROVIDE STATEMENT FROM MASTER TO LOCAL OCMI.
Fire Fighting
Issued 6 July 2000
Resolved
REPLACE FOAM HOSE APPLICATOR IN THE ENGINE ROOM TO THE SATISFACTION OF CLASS.
Navigation
Issued 6 July 2000
Resolved
REPAIR RELIEF VALVE PUMP # ONE (1), STEERING ROOM, TO THE SATISFACTION OF CLASS.
Engineering
Issued 6 July 2000
Resolved
REPAIR OIL WATER SEPARATOR TO THE SATISFACTION OF CLASS, PRIOR TO NEXT US PORT.
Construction/Loadline
Issued 6 July 2000
Resolved
STARBOARD SIDE WEATHER TYPE DOOR, NEXT TO GALLEY NOT CLOSING PROPERLY. REPAIR TO THE SATISFACTION OF CLASS.
Fire Fighting
Issued 6 July 2000
Resolved
EXCESSIVE LEAKING ON FIRE PUMPS ONE (1) AND 2 (TWO). REPAIR TO SATISFACTIONOF CLASS.
Electrical
Issued 6 July 2000
Resolved
REPAIR GENERATOR COOLING PUMP TO THE SATISFACTION OF CLASS.
Lifesaving
Issued 6 July 2000
Resolved
STARBOARD LIFEBOAT BOTTOM RETRO-REFLECTIVE TAPE NOT PRESENT. SERVICE TO THESATISFACTION OF CLASS.
Lifesaving
Issued 6 July 2000
Resolved
REPAIR/REPLACE PORTSIDE OUTBOARD FORWARD SHEAVES NOT WORKING PROPERLY. REPAIR/REPLACE TO THE SATISFACTION OF CLASS.
Fire Fighting
Issued 6 July 2000
Resolved
SERVICE SIX (6) FIRE EXTINGUISHERS IDENTIFIED BY US COAST GUARD PRIOR TO DEPARTURE. PROVIDE SERVICING REPORT TO MSO OFFICE.
Lifesaving
Issued 6 July 2000
Resolved
REPLACE/RENEW PELICAN HOOK "RETAINING STRAPS FOR LIFERAFTS (ALL 4 LIFERAFTS). PROVIDE SERVICING REPORT PRIOR DEPARTURE.
Engineering
Issued 19 July 1999
Resolved
NO. 1 DIESEL GENERATOR HAS NUMEROUS MINOR FUEL LEAKS
Engineering
Issued 19 July 1999
Resolved
MAIN ENGINE F/W COOLER (UPPER) OUTLET GUAGE PORT HAS WOODEN PLUG TO STOP LEAK
Deck/Cargo
Issued 8 February 1999
Resolved
HYDRAULIC LEAKS IWO HATCH COVER CONTROL STATIONS._x001C_ SOLAS 74 I/11_x001C_
Engineering
Issued 8 February 1999
Resolved
EXCESSIVE FUEL OIL LEAKS IWO MDE FUEL OIL HEATERS._x001C_ SOLAS 74 II-2/33
Engineering
Issued 8 February 1999
Resolved
EXCESSIVE FUEL OIL LEAKS IWO FUEL OIL PURIFIERS._x001C_ SOLAS 74 II-2/33
Engineering
Issued 8 February 1999
Resolved
FULE OIL LEAKS IWO AUX BOILER BURNER SUPPLY._x001C_ SOLAS 74 II-2/33
Engineering
Issued 8 February 1999
Resolved
1. EXCESSIVE FUEL OIL LEAKS IWO MAIN ENGINE._x001C_ SOLAS 74 II-2/33
Electrical
Issued 8 February 1999
Resolved
EXCESSIVE FUEL OIL LEAK IWO MAIN GENERATORS._x001C_ SOLAS 74 II-2/33
Engineering
Issued 8 February 1999
Resolved
WASTED CONTAINMENT IWO P & S MAIN DECK F/O VENTS._x001C_ SOLAS74 I/11
Deck/Cargo
Issued 8 February 1999
Resolved
WASTED & DAMAGED BRAKE IWO STBD ANCHOR WINDLASS._x001C_ SOLAS 74 I/11_x001C_ _x001C_ _x001C_
Navigation
Issued 27 May 1998
Resolved
ARPA inoperable.
Accommodation/Occupational Safety
Issued 16 May 1996
Resolved
Renew deteriorated supply line to MSD tank (one located at tank & one located on 3rd deck, overhead, forward engine room).
Fire Fighting
Issued 16 May 1996
Resolved
Free-up all ventilation closures throughout vessel._x001C_ ILLC 66 ANNEX I/19_x001C_ _x001C_ _x001C_
Lifesaving
Issued 16 May 1996
Resolved
Replace grabline to both lifeboats._x001C_ SOLAS 74 (Amended) III/19.2_x001C_ _x001C_ _x001C_
Accommodation/Occupational Safety
Issued 16 May 1996
Resolved
Permanently repair hole on upper side of MSD tank._x001C_ _x001C_ _x001C_ _x001C_
Accommodation/Occupational Safety
Issued 16 May 1996
Resolved
Renew deteriorated fresh water line (inlet and outlet) for refrigeration system, second level, starboard side._x001C_ _x001C_ _x001C_
Fire Fighting
Issued 16 May 1996
Resolved
Renew deteriorated fire main piping on main deck, port side in way of cargohatch #3 and cargo hatch #6._x001C_ SOLAS 74 (AMENDED) II-2/21_x001C_ _x001C_
Electrical
Issued 16 May 1996
Resolved
Provide protective covers to lights in machinery store room and in machinery shop (4 total)._x001C_ SOLAS 74 (UNAMENDED) II-1/27(a)_x001C_ _x001C_
Engineering
Issued 16 May 1996
Resolved
Renew deteriorated pipe penetration for salt water cooling line in way of sludge tank, lower engine room, starboard side.
Lifesaving
Issued 16 May 1996
Resolved
Clean-up hydraulic oil in bilges of pipe tunnel._x001C_ _x001C_ _x001C_ _x001C_
Lifesaving
Issued 16 May 1996
Resolved
Repair general alarm in steering gear room._x001C_ SOLAS 74 (UNAMENDED) III/26(d)_x001C_ _x001C_ _x001C_
Lifesaving
Issued 16 May 1996
Resolved
Provide retro-reflective tape to bottom of port and starboard lifeboat._x001C_ SOLAS 74 (Amended) III/30.2.7_x001C_ _x001C_ _x001C_
Lifesaving
Issued 16 May 1996
Resolved
Provide an additional 80 liters of drinking water for both lifeboats._x001C_ SOLAS 74 (Amended) III/11_x001C_ _x001C_ _x001C_
Fire Fighting
Issued 16 May 1996
Resolved
Provide nozzles & firehoses to all stations on main deck (12 firehoses w/ couplings & 12 nozzles)._x001C_ SOLAS 74 (Amended) II-2/21
Engineering
Issued 16 May 1996
Resolved
Clean oil around and fix oil leak on boiler at injector.
Construction/Loadline
Issued 16 May 1996
Resolved
Repaint loadline on hull in contrasting colors._x001C_ ILLC 66 Annex I/8
Fire Fighting
Issued 16 May 1996
Resolved
Revise fire control plan to include the following: ventilating system including particulars of the fan control positions, the position of dampersand identification numbers of the ventilating fans serving each section._x001C_ SOLAS 74 (Amended) II-2/20.1
Engineering
Issued 16 May 1996
Resolved
Renew deteriorated piping going from distiller to stop valve on service line from distiller tank, outboard of generator on port side, forward in engine room.
Engineering
Issued 16 May 1996
Resolved
Renew deteriorated water supply line to oil separator in lower engine room,port side, over head.
Navigation
Issued 9 April 1991
Resolved
vessel did not have a tidal current tables onboard as required by 33 cfr 164.33 (a)(3)(ii).
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.