PIER PRESSURE

PIER PRESSURE is a 1987 passenger vessel (inspected). The Coast Guard has recorded 66 inspections since 1987, most recently in July 2026, along with 120 deficiencies and 1 casualty investigation in 2009.

Records from 1987 to 2026. Most recent: inspection, 15 July 2026.

Built
1987
Last inspected
15 July 2026
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDI9236
284663
Flag
UNITED STATES
367351890, 367746660 (licence lapsed)
Maury page id
psix-284663

Inspections, by type

…with no type recorded4
Years with a record 38 calendar years (1987–2026)
The 66 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)45.0 ft × 15.0 ft × 7.9 ft
Registered tonnagegross 35 / net 28
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderYOUNG BROTHERS & COMPANY · COREA, ME, UNITED STATES · built 1987
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portEASTPORT, ME
Trade endorsementsCoastwise, unrestricted, Fishery
DocumentationValid · issued 25 September 2025 · expires 31 October 2026
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it35 - Simplified, Gross Ton
28 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDI9236MMSI 367746660 · expired · compulsorily equipped · granted 16 July 2016, cancelled 22 August 2026
WCY3964MMSI 367351890 · expired · compulsorily equipped · granted 25 April 2008, cancelled 21 July 2018
WTJ4173MMSI not assigned · expired · compulsorily equipped · granted 16 June 1997, cancelled 10 November 2007 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 66

15 July 2026 Deficiency Check
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 8438817
16 June 2026 Deadweight Survey · Annual Inspection
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 8394885
16 March 2026 Hull Examination · Internal Structural Exam
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 8326962
13 August 2025 Annual Inspection
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 8202010
23 October 2024 Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 8023351
23 April 2024 Hull Examination · Internal Structural Exam
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 7898099
10 August 2023 Annual Inspection
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 7764570
20 May 2022 Plan Review "T" Boat · COI Inspection
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 7447129
28 March 2022 Hull Examination · Internal Structural Exam
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 7417843
20 August 2021 Annual Inspection · DAPI Audit
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 7317197
22 August 2020 Annual Inspection
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 7073061
29 May 2020 Drydock Exam
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 6933133
21 August 2019 Deficiency Check · DAPI Audit · Annual Inspection
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 6789087
22 April 2019 Hull Examination · Deficiency Check
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 6647480
27 June 2018 Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 6451298
9 August 2017 Administrative Inspection
Administrative · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 6235414
22 May 2017 Deficiency Check · COI Inspection · Examination of Repairs · DAPI Audit
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 6147542
23 January 2017 Hull Examination · Deficiency Check
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 6075367
29 June 2016 Annual Inspection
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 5906080
22 July 2015 Type not recorded
No type recorded · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 5193038
21 May 2014 Administrative Inspection
Administrative · Marine Safety Unit Portsmouth · USCG Northeast District (CGD-NE) · Activity 4864662
23 January 2012 Administrative Inspection
Administrative · Marine Safety Unit Portsmouth · USCG Northeast District (CGD-NE) · Activity 4229953
22 October 2010 Drydock Exam
Physical examination · Marine Safety Unit Portsmouth · USCG Northeast District (CGD-NE) · Activity 3875240
8 April 2009 Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Portsmouth · USCG Northeast District (CGD-NE) · Activity 3448689
16 December 2008 Hull Examination
Physical examination · Marine Safety Unit Portsmouth · USCG Northeast District (CGD-NE) · Activity 3380735
23 April 2008 Annual Inspection
Physical examination · Marine Safety Unit Portsmouth · USCG Northeast District (CGD-NE) · Activity 3189951
14 May 2007 COI Inspection
Physical examination · Marine Safety Unit Portsmouth · USCG Northeast District (CGD-NE) · Activity 2929856
13 March 2007 Hull Examination
Physical examination · Marine Safety Unit Portsmouth · USCG Northeast District (CGD-NE) · Activity 2890472
3 May 2006 Annual Inspection
Physical examination · Marine Safety Unit Portsmouth · USCG Northeast District (CGD-NE) · Activity 2640373
19 January 2006 Hull Examination
Physical examination · Marine Safety Unit Portsmouth · USCG Northeast District (CGD-NE) · Activity 2569585
7 April 2005 Annual Inspection
Physical examination · MSFO Portsmouth · USCG Northeast District (CGD-NE) · Activity 2331017
22 March 2004 Hull Examination · Annual Inspection
Physical examination · MSFO Portsmouth · USCG Northeast District (CGD-NE) · Activity 2027642
4 August 2003 Administrative Inspection
Administrative · MSFO Portsmouth · USCG Northeast District (CGD-NE) · Activity 1866398
2 April 2003 Simplified Stability Test
Physical examination · MSFO Portsmouth · USCG Northeast District (CGD-NE) · Activity 1766989
2 April 2003 Re-Inspection
Physical examination · MSFO Portsmouth · USCG Northeast District (CGD-NE) · Activity 1767023
27 February 2003 Plan Review "T" Boat · Construction Oversight
Physical examination · MSFO Portsmouth · USCG Northeast District (CGD-NE) · Activity 1750730
18 April 2002 Administrative Inspection
Administrative · MSFO Portsmouth · USCG Northeast District (CGD-NE) · Activity 1659139
20 December 2001 COI Inspection · Internal Structural Exam · Hull Examination · Deficiency Check
Physical examination · MSFO Portsmouth · USCG Northeast District (CGD-NE) · Activity 1475352
5 June 2001 Deficiency Check
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1065142
4 June 2001 Re-Inspection
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1441850
18 April 2000 Deficiency Check
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1048545
27 March 2000 Hull Examination
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1369587
27 March 2000 Re-Inspection
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1452652
17 June 1999 Deficiency Check · Inclining Experiment · COI Inspection
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1372664
21 April 1998 Hull Examination · Re-Inspection
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1125507
10 June 1997 Re-Inspection
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1375057
30 April 1997 Hull Examination
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1385985
14 August 1996 Administrative
Administrative · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1086387
5 June 1996 Deficiency Check · COI Inspection
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1355880
20 June 1995 Re-Inspection · Hull Examination · MARPOL Annex V Examination
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1360223
16 June 1994 MARPOL Annex V Examination · Re-Inspection
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1331112
7 June 1993 COI Inspection · Hull Examination · MARPOL Annex V Examination
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1160196
16 May 1993 Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 50876
16 May 1993 Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 213908
16 June 1992 Re-Inspection
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1263630
1 July 1991 Re-Inspection
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 935978
1 April 1991 Hull Examination
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1217690
19 June 1990 COI Inspection
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 906985
30 June 1989 Re-Inspection
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 898980
8 May 1989 Deficiency Check
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1199263
6 April 1989 Hull Examination
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1203599
31 January 1989 Drydock Extension
Administrative · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 896964
26 July 1988 Re-Inspection
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1340059
28 August 1987 Plan Review "T" Boat
Administrative · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1032015
20 August 1987 Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1339246
28 July 1987 Hull Examination · Initial Certification
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1028979

Deficiency record · 120

13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 16 June 2026 Resolved
On a vessel of at least 7.9 meters (26 feet) in length, a visual and audible alarm must be provided at the operating station to indicate a high water level in A space with a through-hull fitting below the deepest load waterline. The indicator light for the alarm in the lazarette was inoperable. Repair or replace light.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 24 June 2026
Resolution: Indicator light was repaired
01 - Certificates & Documentation › 011 - Ships Certificates › USCG Certificate of Documentation (COD)
Issued 16 June 2026 Resolved
The name of the vessel must be marked on some clearly visible exterior part of the port and starboard bow and the stern of the vessel. The vessel is missing the name of the stern. Label name of vessel on the stern.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 15 July 2026
Resolution: Operator appropriately marked the stern of the vessel.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 16 June 2026 Resolved
A vessel must carry one floating water light. The vessel's float light was inoperable. Repair or replace floating water light.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 15 July 2026
Resolution: Operator replaced floating water light
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Other (Conditions of employment)
Issued 16 June 2026 Resolved
Drug testing programs must be conducted in accordance with 49 CFR part 40. The marine employer did not have current list of enrolled employees. Provide Marine inspector with proof of enrollment in a drug and Alcohol program.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 24 June 2026
Resolution: Compny provided current enrollment
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 16 June 2026 Resolved
At each inspection, the owner or managing operator must be prepared to conduct tests and have the vessel ready for inspection of its fire protection equipment. The vessel's fire equipment servicing at lapsed. Provide technician report for servicing of fire equipment.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 17 June 2026
Resolution: Company provided servicing report
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 24 October 2024 Resolved
A vessel on an oceans, coastwise, limited coastwise, or Great Lakes route must carry— Six hand red flare distress signals and 6 orange smoke distress signals. Vessel had 6 red flairs on board during the time of inspection. 46 CFR 180.68(a)
Action required: 701 - Prior to carriage of passengers/cargo
Due 24 October 2024
Resolved 29 October 2024
Resolution: Vessel POC purchased more flairs and put onboard.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 24 October 2024 Resolved
Each item of survival craft equipment must be of good quality, and efficient for the purpose it is intended to serve. MI observed the 2 paddles to not be connected to the life float, the line around the inside top and bottom was frayed and not in serviceable condition, and the weighted metal ring for the bottom was broken. 46 CFR 180.175(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 November 2024
Resolved 29 October 2024
Resolution: Vessel POC sent pictures showing the new line, fixed broken weighted ring, and paddles connexted with a line.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 24 October 2024 Resolved
The float-free link must be:(2) Of proper strength for the size of the lift float as indicated on its identification tag. One of the vessels life-floats float-free links did not have a ID tag. 46 CFR 180.137(b)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 November 2024
Resolved 21 February 2025
Resolution: Vessel POC sent pictures of weak links, clearing deficiency.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 24 October 2024 Resolved
Placards containing instructions for the donning and use of the life jackets aboard the vessel must be posted in conspicuous places that are regularly accessible and visible to the crew and passengers. Vessel did not have life jacket placard. 46 CFR 185.516(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 November 2024
Resolved 29 October 2024
Resolution: Vessel POC sent pictures showing the new life jacket placard onboard.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 24 October 2024 Resolved
Starboard navigation light was not operating at the time of inspection, but was corrected before the inspection was completed.
Action required: 10 - Deficiency Rectified
Due 24 October 2024
Resolved 24 October 2024
Resolution: corrected on the spot.
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 23 April 2024 Resolved
Wire powered ventilation for engine room to automatically shutoff when fixed FF system is activated.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 May 2024
Resolved 3 July 2024
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 10 August 2023 Resolved
Each item of survival craft equipment must be of good quality, and efficient for the purpose it is intended to serve. MI observed the 4 paddles for the Life Floats along with the SOLAS reflective tape to not be in good serviceable condition and need to be replaced. 46 CFR 180.175(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 August 2023
Resolved 21 August 2023
Resolution: Items repaired or replaced.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 10 August 2023 Resolved
A vessel on an oceans, coastwise, limited coastwise, or Great Lakes route must carry— Six hand red flare distress signals and 6 orange smoke distress signals. Vessel had 8 red flairs on board during the time of inspection. Vessel POC purchased 6 more red flairs and placed on board prior to completion of inspection. 46 CFR 180.68(a)
Action required: 10 - Deficiency Rectified
Due 15 August 2023
Resolved 15 August 2023
Resolution: Corrected on the spot
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 10 August 2023 Resolved
Placards containing instructions for the donning and use of the life jackets aboard the vessel must be posted in conspicuous places that are regularly accessible and visible to the crew and passengers. Vessel did not have the correct life jacket model placard. Correct placard was given to the vessel and put on board prior to completion of inspection. 46 CFR 185.516(a)
Action required: 10 - Deficiency Rectified
Due 15 August 2023
Resolved 15 August 2023
Resolution: Corrected on the spot.
04 - Emergency Systems › N/A - No Subsystem › Functionality of Safety Systems
Issued 12 July 2022 Resolved
Connection and operation of fan to intake air to engine room.
Action required: 705 - Other - as specified
Resolved 20 August 2022
Resolution: Installed fyre boy switch and connection of fan in system test sat.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 12 July 2022 Resolved
Fyre boy switch light inop, system is still operational.
Action required: 705 - Other - as specified
Resolved 20 August 2022
Resolution: New indicator and switch installed test sat.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance and inspections
Issued 12 July 2022 Resolved
Found e-pirb battery expired. Limited route to LBS not more than 1 mile from shore.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 August 2022
Resolved 3 August 2022
Resolution: E-pirb battery replaced and test sat. Battery replacement in 2028.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 20 August 2021 Resolved
Found steering bilge pump inop, repair replace pump.
Action required: 10 - Deficiency Rectified
Resolved 20 August 2021
Resolution: Repaired, found bad switch connection.
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 20 August 2021 Resolved
Found DSC location inop, NEMA not working, repair replace.
Action required: 10 - Deficiency Rectified
Resolved 20 August 2021
Resolution: NEMA connection was found and connected, test sat.
05 - Radio Communications › N/A - No Subsystem › VHF EPIRB
Issued 22 August 2020 Resolved
Hydrostatic release for EPIRB was found expired. Replace hydrostatic release with non-expired HRU.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 May 2021
Resolved 20 August 2021
Resolution: New HRU installed.
14 - Pollution Prevention › 144 - MARPOL Annex IV (Not Applicable to PSC Exams conducted in the U.S.) › Sewage treatment plant
Issued 22 August 2020 Resolved
Vessel is not equipped with an installed type I, II, or III MSD and routinely operates with in 3NM from shore. Install a type III holding tank to prevent the discharge of sewage overboard.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 1 May 2021
Resolved 20 August 2021
Resolution: Installed a self contained porta john.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 21 August 2019 Resolved
Indicator light to show operation of bilge pump located in aft compartment fails to indicate when pump is in operation. Prove operation of indicator light.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 September 2019
Resolved 4 September 2019
Resolution: Corrected wireing to light, tested sat.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 21 August 2019 Resolved
Batteries for life float (02) and ring buoy (01) float lights were expired. Provide non expired batteries for life floats and ring buoy.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 September 2019
Resolved 4 September 2019
Resolution: Replaced batteries.
11 - Life Saving Appliances › N/A - No Subsystem › Rigid liferafts
Issued 21 August 2019 Resolved
Type II retroreflective tape on life floats (02) is worn and unserviceable. Replace type II retroreflective tape (all) on both life floats.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 September 2019
Resolved 16 September 2019
Resolution: Replaced with new.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 21 August 2019 Resolved
Running lights (port/stbd) failed to ilumaniate when energised. Prove operation of running lights.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 21 August 2019
Resolved 21 August 2019
Resolution: Corrected on the spot.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 27 June 2018 Resolved
Main engine turbocharger (stbd) side) as an oil leak causing excessive oil to accumulate on the engine and hot surfaces. Repair leak and clean oil from engine and bilge prior to carrying passengers for hire.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 June 2018
Resolution: Pier Pressure fixed leak on turbo of engine to satisfaction of attending Coast Guard Marine Inspector.
05 - Radio Communications › N/A - No Subsystem › VHF EPIRB
Issued 27 June 2018 Resolved
Hydrostatic release on EPIRB is expired. Failure of unit may cause EPIRB to not float free in the event of sinking. Provide non-expired hydrostatic release.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 July 2018
Resolved 10 July 2018
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 27 June 2018 Resolved
Batteries for life-floats and ring buoy were found expired. Expired batteries may prevent units from operating for an extended period of time. Replace batteries.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 July 2018
Resolved 10 July 2018
Resolution: Batteries replaced with new.
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 22 May 2017 Resolved
Attach waterlight to buoy with detachable clip.
Action required: 705 - Other - as specified
Due 22 June 2017
Resolved 17 July 2017
Resolution: An approved buoy was provided
Lifesaving › Lifebuoys › Approval
Issued 22 May 2017 Resolved
Provide a USCG approved ring buoy with light & line attached.
Condition: Invalid
Action required: 705 - Other - as specified
Due 22 June 2017
Resolved 30 May 2017
Resolution: corrected
Stability › Unintentional Flooding › General
Issued 22 May 2017 Resolved
Repair the lazerette high water alarm indicator on the pilothouse console.
Action required: 705 - Other - as specified
Due 22 June 2017
Resolved 17 July 2017
Resolution: bilge alarm sat
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 22 May 2017 Resolved
Provide asprin in the first aid kit
Action required: 705 - Other - as specified
Due 22 June 2017
Resolved 30 May 2017
Resolution: corrected.
Lifesaving › Lifefloat › Float Free
Issued 22 May 2017 Resolved
Provide wooden slats between life floats for stowage, & trice up the basket in the center of the life floats.
Action required: 705 - Other - as specified
Due 22 June 2017
Resolved 30 May 2017
Resolution: Rcvd documentation of correction.
Personnel › Training › First Aid/CPR
Issued 22 May 2017 Resolved
Provide a valid First Aid/CPR training cert.
Action required: 705 - Other - as specified
Due 22 June 2017
Resolved 30 May 2017
Resolution: First Aid/ CPR certification was provided
Operations/Management › Drills/Instruction › Not Conducted
Issued 22 May 2017 Resolved
Provide documentation that drills were being logged and recorded during last 3 months of 2016.
Action required: 705 - Other - as specified
Due 22 June 2017
Resolved 30 May 2017
Resolution: Documentation received.
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 22 May 2017 Resolved
Provide a valid COD.
Action required: 705 - Other - as specified
Due 22 June 2017
Resolved 30 May 2017
Resolution: A valid COD was provided.
Fire Fighting › Fire Bucket › Quantity
Issued 22 May 2017 Resolved
Provide 3 fire buckets onboard vsl.
Action required: 705 - Other - as specified
Due 22 June 2017
Resolved 30 May 2017
Resolution: 03 fire buckets were provided.
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (air intake)
Issued 22 May 2017 Resolved
Provide a means to close the E/R intake ventalation opeaning.
Action required: 705 - Other - as specified
Due 22 June 2017
Resolved 30 May 2017
Resolution: A new fire closure lid was fabricated and installed.
Documentation › Certificates/Documents › FCC Safety Radiotelephony Certificate
Issued 22 May 2017 Resolved
Provide valid FCC SL, Radio Telephony, & Marine Ops Permit.
Action required: 705 - Other - as specified
Due 22 June 2017
Resolved 17 July 2017
Resolution: FCC docs were sat
Lifesaving › Lifefloat › Serviceable
Issued 29 June 2016 Resolved
Make repairs to lifefloat. Vessel restricted to LBS not more than 1 mile from shore until corrected.
Due 29 August 2016
Resolved 31 January 2017
Resolution: Attended vessel. Repairs completed.
Communications › Alarms/Indicators › Bilge Alarm
Issued 29 June 2016 Resolved
Replace bilge alarm for lazaret.
Due 6 July 2016
Resolved 12 July 2016
Resolution: O/O advised that alarm is installed.
Lifesaving › Hand Flares › Quantity
Issued 29 June 2016 Resolved
Provide 1 additional flare. Vessel restricted to LBS until corrected.
Due 29 July 2016
Resolved 29 June 2016
Resolution: Addional flare purchased.
Navigation › Piloting/Steering › Tide/Tidal Current Tables
Issued 29 June 2016 Resolved
Provide tide tables.
Due 29 July 2016
Resolved 29 June 2016
Resolution: Tide tables onboard.
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 29 June 2016 Resolved
Label normal/override switch for fireboy.
Due 6 July 2016
Resolved 31 January 2017
Resolution: Attended vessel. Switch labeled.
Communications › Radio Communications › EPIRB
Issued 29 June 2016 Resolved
Update EPIRB registration. Vessel restricted to not more than 3 miles until corrected.
Due 12 July 2016
Resolved 31 January 2017
Resolution: Attended vessel. Registration is valid.
Electrical › Electrical Distribution System (service) › Cable
Issued 29 June 2016 Resolved
Remove dead-end cables.
Due 6 July 2016
Resolved 11 July 2016
Resolution: Wires have been removed.
Communications › Alarms/Indicators › Bilge Alarm
Issued 29 June 2016 Resolved
Label engine room and lazaret bilge alarms.
Due 6 August 2016
Resolved 31 January 2017
Resolution: Attended vessel. Alarms labeled.
Fire Fighting › Portable CO2 Fire Extinguisher › Number
Issued 8 April 2009 Resolved
Provide (01) BI fire extinquisher for the operating station.
Due 10 April 2009
Resolved 10 April 2009
Documentation › Markings/Placards › Warning Signs
Issued 8 April 2009 Resolved
Provide emergency exit sign.
Due 10 April 2009
Resolved 10 April 2009
Documentation › Certificates/Documents › FCC SSL
Issued 23 April 2008 Resolved
Provide FCC station license.
Condition: Unknown
Action required: 705 - Other - as specified
Resolved 18 May 2008
Resolution: Received Document
Engineering › Bilge Water Management System › Hose
Issued 23 April 2008 Resolved
Replace Rule Pump discharge hose with SAE OR CG approved petroleum (petro and heat resistant) hose IAW 46 CFR Subpart G Piping Systems.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 23 May 2008
Resolved 25 April 2008
Resolution: Proper hoses on main pumps.
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 7 April 2005 Resolved
Attach waterlight around body of lifefloat.
Action required: 705 - Other - as specified
Due 30 April 2005
Resolved 15 April 2005
Lifesaving › Lifejacket/PFD (General) › Condition
Issued 7 April 2005 Resolved
Provide one child lifejacket. Child passenger count reduced to five.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 April 2005
Resolved 15 April 2005
Lifesaving › Lifebuoys › Serviceable
Issued 7 April 2005 Resolved
Repair replace lifering.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 April 2005
Resolved 15 April 2005
Resolution: Renewed.
Communications › Radio Communications › EPIRB
Issued 7 April 2005 Resolved
Renew Hydro release.
Action required: 705 - Other - as specified
Due 30 May 2005
Resolved 15 April 2005
Resolution: Renewed.
Lifesaving › Hand Flares › Quantity
Issued 27 April 2004 Resolved
Provide three each day and night flares.
Condition: Unknown
Action required: 705 - Other - as specified
Due 4 May 2004
Resolved 28 May 2004
Resolution: Provided required flares.
Documentation › Certificates/Documents
Issued 27 April 2004 Resolved
Post stability letter issued APR 2, 2003. LEGACY COMPONENT DESC: Stability Letter
Condition: Unknown
Action required: 705 - Other - as specified
Due 10 May 2004
Resolved 28 April 2004
Resolution: PROVIDED AND POSTED.
Engineering › Fuel Oil Service System › Piping
Issued 20 December 2001 Resolved
MAKE PROPER REPAIRS TO EMERGENCY FUEL SHUT OFF HANDLE
Condition: Unknown
Due 25 April 2002
Resolved 15 May 2002
Resolution: REPLACED
Lifesaving › Buoyant Apparatus
Issued 20 December 2001 Resolved
PROVIDE TWO MARKED PADDLES FOR EA LIFE FLOAT LEGACY COMPONENT DESC: PADDLES
Condition: Unknown
Due 24 April 2002
Resolved 15 May 2002
Resolution: PROVIDED
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 20 December 2001 Resolved
REPLACE TWO ADULT AND ONE CHILD PFD W/ RETRO TAPE
Condition: Unknown
Due 24 April 2002
Resolved 15 May 2002
Resolution: REPLACED
Lifesaving
Issued 4 June 2001 Resolved
REPLACE 3 DAY FLARES PRIOR TO DEPARTURE.
Condition: Unknown
Due 5 June 2001
Resolved 11 June 2001
Lifesaving
Issued 4 June 2001 Resolved
REPLACE 19 CONDEMNED PFD'S PRIOR TO TAKING PASSENGERS.
Condition: Unknown
Due 5 June 2001
Resolved 11 June 2001
Lifesaving
Issued 4 June 2001 Resolved
REPLACE HYDROSTATIC RELEASE FOR EPIRB PRIOR TO TAKING ON PASSENGERS.
Condition: Unknown
Due 5 June 2001
Resolved 11 June 2001
Fire Fighting
Issued 4 June 2001 Resolved
SHOW PROOF OF ANNUAL SERVICE FOR ALL PORTABLE FIRE EXTINGUISHERS
Condition: Unknown
Due 5 June 2001
Resolved 11 June 2001
Navigation
Issued 27 March 2000 Resolved
PROVIDE TIDE TABLE
Condition: Unknown
Due 15 April 2000
Resolved 18 April 2000
Navigation
Issued 27 March 2000 Resolved
PROVIDE LIGHT LIST
Condition: Unknown
Due 15 April 2000
Resolved 18 April 2000
Navigation
Issued 27 March 2000 Resolved
POST EMERG BCST INSTRUCTION
Condition: Unknown
Due 15 April 2000
Resolved 18 April 2000
Lifesaving
Issued 27 March 2000 Resolved
PROVIDE 3 RED FLARES
Condition: Unknown
Due 27 March 2000
Resolved 18 April 2000
Navigation
Issued 27 March 2000 Resolved
PROVIDE CURRENT TABLE
Condition: Unknown
Due 27 March 2000
Resolved 18 April 2000
Unknown
Issued 27 March 2000 Resolved
PROVIDE WASTE MANAGEMENT PLAN
Condition: Unknown
Due 15 April 2000
Resolved 18 April 2000
Fire Fighting
Issued 27 March 2000 Resolved
PROVIDE THREE 2.5GAL BUCKET WITH LANYARD
Condition: Unknown
Due 18 April 2000
Resolved 18 April 2000
Navigation
Issued 27 March 2000 Resolved
POST DEVATION TABLE
Condition: Unknown
Due 15 April 2000
Resolved 18 April 2000
Navigation
Issued 17 June 1999 Resolved
RELOCATE NAVIGATION SIDELIGHTS TO PROVIDE UNOBSTRUCTED VIEW.
Condition: Unknown
Due 17 June 1999
Resolved 23 June 1999
Navigation
Issued 17 June 1999 Resolved
PROPERLY MOUNT MASTHEAD NAVIGATION LIGHT.
Condition: Unknown
Due 17 June 1999
Resolved 23 June 1999
Documentation
Issued 17 June 1999 Resolved
PROVIDE VALID FCC RADIO TELEPHONY CERTIFICATE.
Condition: Unknown
Due 17 June 1999
Resolved 23 June 1999
Documentation
Issued 17 June 1999 Resolved
CONDUCT SIMPLIFIED STABILITY TEST TO PROVE VESSEL STABILITY DUE TO MDE CHANGE. CURRENT MDE IS 1000 POUNDS LIGHTER THAN PREVIOUS MDE.
Condition: Unknown
Due 17 June 1999
Resolved 23 June 1999
Construction/Loadline
Issued 17 June 1999 Resolved
INSTALL SECOND HOSE CLAMP ON RAW WATER SUCTION LINE ON INLET SIDE OF SEA STRAINER.
Condition: Unknown
Due 17 June 1999
Resolved 23 June 1999
Engineering
Issued 17 June 1999 Resolved
RELOCATE EMERGENCY FUEL OIL SHUT-OFF VALVE TO LABELED ACCESS PLATE.
Condition: Unknown
Due 23 June 1999
Resolved 23 June 1999
Lifesaving
Issued 17 June 1999 Resolved
MAKE PERMANENT REPAIRS TO LIFE FLOAT NETTING AND LASH PADDLES TO LIFE FLOAT.
Condition: Unknown
Due 23 June 1999
Resolved 23 June 1999
Lifesaving
Issued 17 June 1999 Resolved
REPLACE LIFE FLOAT RETRO-REFLECTIVE TAPE.
Condition: Unknown
Due 17 June 1999
Resolved 23 June 1999
Construction/Loadline
Issued 17 June 1999 Resolved
PROVIDE SPECIFICATIONS FOR NEW ENGINE ROOM COMPARTMENT INSULATION.
Condition: Unknown
Due 24 August 1999
Resolved 25 August 1999
Construction/Loadline
Issued 17 June 1999 Resolved
PERMANENTLY REPAIR PORT TRANSOM EXHAUST PATCH WHERE DELAMINATED.
Condition: Unknown
Due 23 June 1999
Resolved 23 June 1999
Electrical
Issued 17 June 1999 Resolved
PROPERLY DEAD END OR REMOVE UNUSED ELECTRICAL CABLES IN THE LAZARETTE.
Condition: Unknown
Due 17 June 1999
Resolved 23 June 1999
Lifesaving
Issued 17 June 1999 Resolved
REPLACE 20" RING LIFE BUOY WITH 24" RING LIFE BUOY.
Condition: Unknown
Due 17 June 1999
Resolved 23 June 1999
Navigation
Issued 17 June 1999 Resolved
PROVE PROPER OPERATION OF EMERGENCY TILLER.
Condition: Unknown
Due 17 June 1999
Resolved 23 June 1999
Lifesaving
Issued 17 June 1999 Resolved
PROPERLY LABEL CHILDRENS LIFEJACKET STOWAGE LOCATION.
Condition: Unknown
Due 23 June 1999
Resolved 23 June 1999
Fire Fighting
Issued 21 April 1998 Resolved
PROPERLY MOUNT THE FIRE EXTINGUISHER PROVIDED IN THE GALLEY AREA WITH AN APPROVED BRACKET.
Condition: Unknown
Due 1 June 1998
Resolved 21 May 1998
Lifesaving
Issued 21 April 1998 Resolved
PROVE PROPER OPERATION OF THE INSTALLED WATERLIGHT FOR LIFERING.
Condition: Unknown
Due 1 June 1998
Resolved 21 May 1998
Documentation
Issued 21 April 1998 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 1 June 1998
Resolved 21 May 1998
Documentation
Issued 21 April 1998 Resolved
PROVIDE VALID MARINE RADIO OPERATOR'S LICENSE.
Condition: Unknown
Due 1 June 1998
Resolved 21 May 1998
Lifesaving
Issued 21 April 1998 Resolved
PROVIDE PADDLES MARKED WITH THE VESSEL'S NAME FOR THE VESSEL'S BUOYANT APPARATUS.
Condition: Unknown
Due 1 June 1998
Resolved 21 May 1998
Deck/Cargo
Issued 21 April 1998 Resolved
INSTALL VESSEL ANCHOR AND ANCHOR LINE.
Condition: Unknown
Due 1 June 1998
Resolved 21 May 1998
Electrical
Issued 21 April 1998 Resolved
PROPERLY MOUNT AND SECURE ELECTRICAL LINES FOR INSTALLED LIGHT IN FORWARD ACCOMADATION AREA OR REMOVE.
Condition: Unknown
Due 1 June 1998
Resolved 21 May 1998
Documentation
Issued 10 June 1997 Resolved
OBTAIN VALID FCC MARINE OPERATORS PERMIT.
Condition: Unknown
Due 21 July 1997
Resolved 21 July 1997
Lifesaving
Issued 10 June 1997 Resolved
PROVIDE NEW RING LIFE BUOY.
Condition: Unknown
Due 21 July 1997
Resolved 21 July 1997
Lifesaving
Issued 10 June 1997 Resolved
PROVIDE 3 ADDITIONAL SMOKE FLARES.
Condition: Unknown
Due 21 July 1997
Resolved 21 July 1997
Fire Fighting
Issued 10 June 1997 Resolved
WEIGH ENGINE ROOM HALON BOTTLE.
Condition: Unknown
Due 21 July 1997
Resolved 21 July 1997
Construction/Loadline
Issued 10 June 1997 Resolved
VESSEL IS NOT TO OPERATE UNTIL PERMANENT REPAIRS ARE MADE TO THE SHAFT TUBE.
Condition: Unknown
Due 21 July 1997
Resolved 21 July 1997
Documentation
Issued 10 June 1997 Resolved
OBTAIN VALID FCC RADIOTELEPHONE CERTICATE.
Condition: Unknown
Due 21 July 1997
Resolved 21 July 1997
Lifesaving
Issued 5 June 1996 Resolved
PROVIDE FOR THE VESSEL (11) ELEVEN ADDITIONAL, TYPE I, USCG APPROVED, LIFEJACKETS. VESSEL IS LIMITED TO CARRYING (40) FORTY ADULTS UNTIL THIS REQUIREMENT HAS BEEN CLEARED BY A USCG MARINE INSPECTOR.
Condition: Unknown
Due 5 July 1996
Resolved 20 July 1996
Lifesaving
Issued 16 June 1994 Resolved
PROVIDE NEW BATTERY FOR WATER LIGHT ON LIFE FLOAT.
Condition: Unknown
Due 17 June 1994
Resolved 17 June 1994
Documentation
Issued 7 June 1993 Resolved
PROVIDE DOCUMENTATION ON CHEMICAL TESTING AS PER 46 CFR PART 16.
Condition: Unknown
Due 12 August 1993
Resolved 12 August 1993
Lifesaving
Issued 7 June 1993 Resolved
CONDUCT UNDERWAY EMERGENCY DRILLS IN THE PRESENCE OF A CG MARINE INSPECTOR.
Condition: Unknown
Due 12 August 1993
Resolved 12 August 1993
Lifesaving
Issued 19 June 1990 Resolved
PROVIDE THREE (3) APPROVED RED DISTRESS FLARES.
Condition: Unknown
Due 19 June 1990
Resolved 19 June 1990
Engineering
Issued 19 June 1990 Resolved
PROPERLY RE-STENCIL EMERGENCY FUEL OIL SHUT OFF VALVE.
Condition: Unknown
Due 19 June 1990
Resolved 19 June 1990
Lifesaving
Issued 19 June 1990 Resolved
PROPERLY STENCIL NUMBER OF PERSONS CAPACTIY ON BOTH LIFE FLOATS.
Condition: Unknown
Due 19 June 1990
Resolved 19 June 1990
Lifesaving
Issued 19 June 1990 Resolved
PROVIDE FOUR (4) ADDITIONAL ADULT TYPE I LIFE JACKETS. VESSEL IS LIMITED TO 47 TOTAL PERSONS ON BOARD UNTIL THIS REQUIREMENT IS COMPLETED.
Condition: Unknown
Due 19 June 1990
Resolved 19 June 1990
Fire Fighting
Issued 30 June 1989 Resolved
SERVICE AND HYDRO BOTH PORTABLE FIRE EXTINGUISHERS PRIOR TO CARRIAGE OF PASSENGERS.
Condition: Unknown
Due 30 June 1989
Resolved 30 June 1989
Construction/Loadline
Issued 30 June 1989 Resolved
STENCIL ESCAPE HATCH FOR FORWARD ACCOMMODATION AREA IAW 46 CFR 185-30.15. TO BE COMPLETED PRIOR TO CARRIAGE OF PASSENGERS.
Condition: Unknown
Due 30 June 1989
Resolved 30 June 1989
Fire Fighting
Issued 8 May 1989 Resolved
INSTALL APPROVED FIXED FIRE FIGHTING IN ACCOMMODATION SPACE OR REMOVE CARPET TILE FROM BULKHEAD PRIOR TO 30 JUNE 1989.
Condition: Unknown
Due 8 May 1989
Resolved 8 May 1989
Accommodation/Occupational Safety
Issued 6 April 1989 Resolved
IN ACCORDANCE WITH NVIC 8-87 REMOVE CARPET PANELS FROM INTERIOR OF CABIN.
Condition: Unknown
Due 6 April 1989
Resolved 6 April 1989
Accommodation/Occupational Safety
Issued 6 April 1989 Resolved
IN ACCORDANCE WITH 46 CFR 182.40-1 REMOVE PLASTIC ELBOW IN THROUGH HULL FITTING FOR SINK IN HEAD AND REPLACE WITH A METAL FITTING.
Condition: Unknown
Due 6 April 1989
Resolved 6 April 1989
Navigation
Issued 26 July 1988 Resolved
IN ACCORDANCE WITH 46 CFR 184.25-1, REPAIR RADIO OUTPUT METER.
Condition: Unknown
Due 26 July 1988
Resolved 26 July 1988
Lifesaving
Issued 26 July 1988 Resolved
IN ACCORDANCE WITH 46 CFR 180.20-5, MARK THE TWO LIFEFLOATS IN AT LEAST 1 1/2 INCH LETTERS, WITH THE CAPACITY OF THE DEVICE.
Condition: Unknown
Due 26 July 1988
Resolved 26 July 1988
Engineering
Issued 28 July 1987 Resolved
MARK THE EMERGENCY FUEL SHUT OFF IN ACCORDANCE WITH 46 CFR 185.30-20.
Condition: Unknown
Due 28 July 1987
Resolved 28 July 1987
Fire Fighting
Issued 28 July 1987 Resolved
PROVIDE AN APPROVED MOUNTING BRACKET FOR THE BI FIRE EXTINGUISHER.
Condition: Unknown
Due 28 July 1987
Resolved 28 July 1987
Lifesaving
Issued 28 July 1987 Resolved
VESSEL IS RESTRICTED TO THE CARRIAGE OF NOT MORE THAN 46 PERSONS TOTAL INCLUDING CREW UNTIL 5 ADDITIONAL TYPE I PFD'S ARE PROVIDED IN ACCORDANCE WITH 46 CFR 180.20-5.
Condition: Unknown
Due 28 July 1987
Resolved 28 July 1987
Fire Fighting
Issued 28 July 1987 Resolved
VESSEL IS REQUIRED TO CARRY ONE ADDITIONAL BII FIRE EXTINGUISHER UNTIL THE FIXED HALON SYSTEM IS EQUIPPED WITH A MANUAL RELEASE.
Condition: Unknown
Due 28 July 1987
Resolved 28 July 1987
Lifesaving
Issued 28 July 1987 Resolved
VESSEL IS RESTRICTED FROM OPERATING UNTIL 6 ORANGE PYROTECHNIC DEVICES ARE PLACED ABOARD IN ACCORDANCE WITH 46 CFR 180.35-5.
Condition: Unknown
Due 28 July 1987
Resolved 28 July 1987
Documentation
Issued 28 July 1987 Resolved
VESSEL IS RESTRICTED FROM OPERATING UNTIL THE CERTIFICATE OF DOCUMENTATION IS PLACED ABOARD IN ACCORDANCE WITH 46 CFR 67.45-5.
Condition: Unknown
Due 28 July 1987
Resolved 28 July 1987

Casualty record · 1

29 June 2009Routine · role: Involved in a Marine Casualty · activity 3534534
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Recorded names · 1

LADY PATRICIA (2009). Names as the Coast Guard recorded them in incident records, with the years they appear; some are renames and some are spelling variants.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.