Records from 1987 to 2017. Most recent: inspection, 7 February 2017.
Documentation record
Registered dimensions (L × B × D)46.0 ft × 13.0 ft × 3.8 ft
Registered tonnagegross 12 / net 10
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderROBERT S MEEKINS · CHURCH CREEK, MD, UNITED STATES · built 1986
Hull materialWood
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portSTEVENSVILLE, MD
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 5 August 2026 · expires 30 September 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it12 - Simplified, Gross Ton
10 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 43
7 February 2017
Administrative Inspection
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6084166
13 December 2016
Internal Structural Exam · Drydock Exam
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6081834
31 May 2016
Annual Inspection · DAPI Audit
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 5974721
11 March 2014
Hull Examination · Internal Structural Exam
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 4818151
3 August 2011
Administrative Inspection
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 4104102
12 March 2009
Annual Inspection · Hull Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 3432466
15 April 2008
Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 3185558
12 September 2007
Administrative Inspection
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 3056115
15 March 2007
Hull Examination · COI Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2886586
5 April 2006
Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2626295
6 April 2005
Periodic Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2337511
11 March 2005
Hull Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2307884
19 April 2004
Periodic Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2047641
18 April 2003
Re-Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1826608
21 March 2003
Hull Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1760594
8 April 2002
COI Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1601594
18 April 2001
Re-Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1366287
13 March 2001
Hull Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1458846
20 April 2000
Re-Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1464952
22 April 1999
Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1108908
20 April 1999
COI Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 798017
10 March 1999
Hull Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 807664
18 May 1998
Re-Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1406340
18 April 1997
Re-Inspection · Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1452308
21 March 1997
Hull Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1414765
18 April 1996
COI Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1445068
4 April 1995
Re-Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1159373
2 March 1995
Hull Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 834736
25 May 1994
Re-Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1174177
21 April 1993
Administrative
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1134398
21 April 1993
COI Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1134834
23 March 1992
Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1011420
11 February 1992
Re-Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1318756
24 January 1992
Hull Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1448391
6 March 1991
Re-Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 899328
30 November 1990
Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1212350
31 October 1990
Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 917615
17 April 1990
Drydock Extension · COI Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 912688
31 May 1989
Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1203342
27 April 1989
Drydock Extension
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1347406
8 March 1989
Re-Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1351057
31 March 1988
Re-Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1034839
23 April 1987
Initial Certification · Hull Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1310347
Documentation › Certificates/Documents › FCC SSL
Issued 12 March 2009
Resolved
Prove that vessel has a valid safety radiotelephony certificate for the VHF radio.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 April 2009
Resolution: Vessel owner produced a valid certificate.
Electrical › Electric Supply System (service) › Cable
Issued 5 April 2006
Resolved
Replace welding grade battery cable with approved marine grade battery cable.
Due 20 April 2006
Resolved 12 April 2006
Resolution: Purchased and installed new cable. O/op faxed purchase receipt to office, see vsl file.
Fire Fighting › Portable CO2 Fire Extinguisher › Service
Issued 6 April 2005
Resolved
Provide hydrostatic testing for two portable CO2 fire extinguishers.
Action required: 701 - Prior to carriage of passengers/cargo
Due 6 April 2005
Resolved 15 April 2005
Personnel › Training › First Aid/CPR
Issued 18 April 2003
Resolved
RENEW RED CROSS FIRST AID/CPR CERTIFICATION.
Action required: 705 - Other - as specified
Due 18 May 2003
Resolved 13 August 2004
Communications › Alarms/Indicators › High Water Alarm
Issued 8 April 2002
Resolved
PROVIDE VISUAL INDICATING LIGHT ON HIGH WATER ALARM. LEGACY COMPONENT DESC: High Water Alarm
Action required: 701 - Prior to carriage of passengers/cargo
Due 22 April 2002
Resolved 6 April 2006
Construction/Loadline
Issued 13 March 2001
Resolved
REPAIR OR REPLACE TWO INCH SEA SUCTION VALVE.
Condition: Unknown
Due 13 April 2001
Resolved 8 April 2002
Lifesaving
Issued 20 April 1999
Resolved
RENEW GRAB LINE ON RING BUOY WITH SUN RESISTANT LINE.
Condition: Unknown
Due 20 April 1999
Resolved 20 April 1999
Fire Fighting
Issued 10 March 1999
Resolved
INSTALL AN APPROVED FIXED FIRE FIGHTING SYSTEM IN ER.
Condition: Unknown
Due 10 March 1999
Resolved 10 March 1999
Construction/Loadline
Issued 10 March 1999
Resolved
REPAIR HIGH BILGE ALARM.
Condition: Unknown
Due 16 March 1999
Resolved 16 March 1999
Construction/Loadline
Issued 18 April 1997
Resolved
NO HIGH WATER BILGE ALARM INSTALLED._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 14 May 1997
Resolved 1 July 1997
Unknown
Issued 18 April 1997
Resolved
NO UNDERWAY EXAM CONDUCTED._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 14 May 1997
Resolved 1 July 1997
Lifesaving
Issued 18 April 1997
Resolved
FIRST AID KIT NOT IN ACCORDANCE WITH 46 CFR SECTION 160.041 SUBCHAPTER Q.
Condition: Unknown
Due 14 May 1997
Resolved 1 July 1997
Documentation
Issued 18 April 1996
Resolved
Provide a crew training logbook I.A.W 46 Code of Federal Regulations Part 185.420.
Condition: Unknown
Due 11 July 1996
Resolved 27 August 1996
Lifesaving
Issued 18 April 1996
Resolved
Properly renew deteriorated ring buoy grab lines or replace ring buoy priorto the carriage of passengers for hire.
Condition: Unknown
Due 11 July 1996
Resolved 27 August 1996
Electrical
Issued 18 April 1996
Resolved
Properly repair busted intake manifold and prove proper operation of the auxiliary generator.
Condition: Unknown
Due 11 July 1996
Resolved 27 August 1996
Engineering
Issued 6 March 1991
Resolved
has sflrxable fuel lines in excess of 30 inches.
Condition: Unknown
Due 6 March 1991
Resolved 6 March 1991
Fire Fighting
Issued 6 March 1991
Resolved
improper portable fire ext. brackets.
Condition: Unknown
Due 6 March 1991
Resolved 6 March 1991
Engineering
Issued 17 April 1990
Resolved
PROVIDE HEAT SHIELD FOR DAHLE F/O FILTER
Condition: Unknown
Due 17 April 1990
Resolved 17 April 1990
Navigation
Issued 17 April 1990
Resolved
PROVIDE THREE ORANGE DISTRESS FLARES
Condition: Unknown
Due 17 April 1990
Resolved 17 April 1990
Navigation
Issued 17 April 1990
Resolved
PROVIDE LETTER TO MSO BALTIMORE STATING DRUG TESTING PROGRAM HAS BEEN STARTED PRIOR TO 21DEC90
Condition: Unknown
Due 17 April 1990
Resolved 17 April 1990
Construction/Loadline
Issued 17 April 1990
Resolved
MARK EMERGENCY ESCAPE FROM CABIN
Condition: Unknown
Due 17 April 1990
Resolved 17 April 1990
Lifesaving
Issued 8 March 1989
Resolved
PUT RETROREFLECTIVE MATERIAL ON ALL REVERSIBLE PFD'S (42 ADULT & 10 10 CHILD'A) ACTUAL COMPLIANCE DATE FOR ABOVE REQUIREMENTS: 8APR89
Condition: Unknown
Due 8 March 1989
Resolved 8 March 1989
Electrical
Issued 8 March 1989
Resolved
PROVIDE VOLT METER FOR OMAR GENERATOR
Condition: Unknown
Due 8 March 1989
Resolved 8 March 1989
Fire Fighting
Issued 8 March 1989
Resolved
MARK LOCATION OF CO2 FIRE EXTINGUISHER
Condition: Unknown
Due 8 March 1989
Resolved 8 March 1989