Records from 1989 to 2017. Most recent: inspection, 24 May 2017.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 42
24 May 2017
Administrative Inspection
Administrative · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 6154339
23 February 2011
Deficiency Check
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3951185
23 October 2007
Re-Inspection · Ballast Water Examination · Deficiency Check · MTSA Verification
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3085656
23 November 2005
Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2539830
11 August 2005
COI Inspection · Examination of Repairs · Hull Examination
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2530965
14 December 2004
Administrative Inspection
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2259060
21 October 2004
Re-Inspection · MTSA Verification
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2235336
22 December 2003
Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 1972238
7 October 2003
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1933806
28 May 2003
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1804682
21 November 2002
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1708751
20 September 2001
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1074225
5 September 2001
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1384868
31 July 2000
Hull Examination · COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1445652
12 May 2000
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 164536
31 August 1999
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1461197
15 July 1998
Hull Examination · COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1402678
16 January 1998
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1414919
13 January 1998
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 786273
26 June 1997
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1117775
26 March 1997
Deficiency Check
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1092341
14 March 1997
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 95823
20 October 1996
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1158150
16 October 1996
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1424292
30 June 1995
COI Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1355310
16 March 1995
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 869018
3 August 1994
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1457195
4 October 1993
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 847036
3 June 1993
Hull Examination · COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1376974
8 October 1992
Examination of Repairs
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1458041
1 September 1992
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 85725
8 July 1992
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1397818
14 May 1992
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 956940
3 September 1991
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 939742
29 August 1991
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 644258
29 August 1991
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 938288
10 June 1991
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1243919
17 April 1991
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 909129
10 April 1991
Damage Survey · Examination of Repairs
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 899366
22 August 1990
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 923197
10 July 1990
Initial Certification
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 922401
23 September 1989
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 455873
Operations/Management › Navigation Safety › Navigation Underway, General
Issued 23 October 2007
Resolved
Provide updated approved operations manual
Due 25 December 2007
Resolved 23 February 2011
Construction/Loadline › Hull
Issued 7 October 2003
Resolved
Prior deficiency cleared in error.
Provide visual and NDT testing for installation of newly constructed leg pads. LEGACY COMPONENT DESC: Leg Pads
Action required: 705 - Other - as specified
Due 1 November 2003
Resolved 21 October 2003
Resolution: Provided
Lifesaving
Issued 5 September 2001
Resolved
PROVIDE VISUAL INDICATORS AT SOUND POWERED PHONE STATIONS AT ALL MACHINERY SPACE LOCATIONS.
Condition: Unknown
Due 20 September 2001
Resolved 20 September 2001
Documentation
Issued 5 September 2001
Resolved
UPDATE OPERATIONS MANUAL TO INCLUDE HURRICANE ACTION PLANS AND PROCEDURES FOR LOSS OF PILOTHOUSE CONTROL.
Condition: Unknown
Due 20 September 2001
Resolved 20 September 2001
Documentation
Issued 5 September 2001
Resolved
ANNUAL REVIEW OF SOPEP NOT SUBMITTED AS REQUIRED.
Condition: Unknown
Due 20 September 2001
Resolved 20 September 2001
Construction/Loadline
Issued 5 September 2001
Resolved
MAKE OILY WATER SEPARATOR OPERATIONAL.
Condition: Unknown
Due 20 September 2001
Resolved 20 September 2001
Lifesaving
Issued 31 July 2000
Resolved
Install a loud hailer speaker on the main deck aft.
Condition: Unknown
Due 31 July 2000
Resolved 31 July 2000
Engineering
Issued 31 July 2000
Resolved
Install shaft tachometers on the bridge control as required by 46 CFR 113.37.
Condition: Unknown
Due 31 July 2000
Resolved 31 July 2000
Engineering
Issued 31 July 2000
Resolved
Install local control for both outboard main diesel engines as part of the engine room automation and as required by 46 CFR 130.120(a)(2).
Condition: Unknown
Due 31 July 2000
Resolved 31 July 2000
Documentation
Issued 31 July 2000
Resolved
Submit for approval to G-MSC the Engine Room Automation Test Procedures asrequired by 46 CFR 130.480.
Condition: Unknown
Due 31 July 2000
Resolved 31 July 2000
Lifesaving
Issued 31 August 1999
Resolved
DEMONSTRATE COMPLIANCE WITH D8 POLICY LETTER DATED 12NOV98 "RESCUE BOAT REQUIREMENTS ON OFFSHORE SUPPLY VESSELS" TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR.
Condition: Unknown
Due 31 August 1999
Resolved 31 August 1999
Engineering
Issued 31 August 1999
Resolved
DEMONSTRATE COMPLIANCE WITH NVIC 1-78 CH1. "AUTOMATION OF OFFSHORE SUPPLY VESSELS OF 100GT AND OVER" TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR, OR PROVIDE TWO (2) ADDITIONAL DDE'S/ OILERS FOR ENGINEERING WATCHES.
Condition: Unknown
Due 31 August 1999
Resolved 31 August 1999
Documentation
Issued 16 January 1998
Resolved
COMPLY WITH THE PROVISIONS SET FORTH IN 46 CFR 67.7 (VESSELS REQUIRING DOCUMENTATON) AND 46 CFR 67.323 (COASTWISE OR GREAT LAKES ENDORSEMENTS) _x001C_ FOR TRADE IN U.S. TERRITORIAL WATERS.
Condition: Unknown
Due 16 February 1998
Resolved 26 March 1998
Unknown
Issued 16 January 1998
Resolved
Unknown Component - Unknown Cause/Condition
Condition: Unknown
Due 25 February 1998
Resolved 25 February 1998
Construction/Loadline
Issued 26 March 1997
Resolved
VSL IS TO OPERATE OWS WITH BILGE ALARM SET AT 15 PPM, HOWEVER THE ALARM MAYBE INCREASED TO NOT MORE THAN 100 PPM FOR INITIAL START-UP FLUSHING ONLY. OWS IS TO BE FIXED TO OPERATE IAW MANUFACTURER'S CRITERIA AND USCG APPROVALSTANDARDS TO THE SATISFACTION OF COGNIZANT OCMI.
Condition: Unknown
Due 26 March 1997
Resolved 26 March 1997
Engineering
Issued 16 October 1996
Resolved
PROVIDE ONBOARD AN OILY WATER SEPARATOR AS IAW 33 CFR 155.360
Condition: Unknown
Due 16 October 1996
Resolved 16 October 1996
Navigation
Issued 16 October 1996
Resolved
PROVIDE ONBOARD A NAVTEX RECEIVER AS REQUIRED FOR AN OSV OVER 300 GT.
Condition: Unknown
Due 16 October 1996
Resolved 16 October 1996
Construction/Loadline
Issued 8 October 1992
Resolved
SUBMIT PLANS TO MARINE SAFETY CENTER FOR MODIFICATIONS TO LEG HOUSING SUPPORTS.
Condition: Unknown
Due 8 October 1992
Resolved 8 October 1992
Unknown
Issued 17 April 1991
Resolved
SUBMIT HULL AND STRUCTURAL PLANS AS PER MSC-1 LTR SERIAL H1-10107 DATED_x001C_ 31JAN91
Condition: Unknown
Due 17 April 1991
Resolved 17 April 1991
Unknown
Issued 10 July 1990
Resolved
PRESENT OPERATIONS MANUAL FOR COAST GUARD APPROVAL.
Condition: Unknown
Due 10 July 1990
Resolved 10 July 1990
Unknown
Issued 10 July 1990
Resolved
PRESENT VESSEL FOR COAST GUARD DRYDOCK INSPECTION.
Condition: Unknown
Due 10 July 1990
Resolved 10 July 1990
Unknown
Issued 10 July 1990
Resolved
CONDUCT NON-DESTRUCTIVE TESTING OF ALL FOUR JACKING LEGS ON OPPOSITE SIDE OF JACKING GEAR AND WELD BUTTS.
Condition: Unknown
Due 10 July 1990
Resolved 10 July 1990
Unknown
Issued 10 July 1990
Resolved
PRESENT FIRE CONTROL PLAN FOR COAST GUARD APPROVAL.
Condition: Unknown
Due 10 July 1990
Resolved 10 July 1990
Unknown
Issued 10 July 1990
Resolved
PRESENT VESSEL FOR STABILITY INCLINING TEST WITNESSED BY COAST GUARD.
Condition: Unknown
Due 10 July 1990
Resolved 10 July 1990
Unknown
Issued 10 July 1990
Resolved
REPAIR BOTH ANCHORS FOR IMMEDIATE USE WITHOUT ASSISTANCE FROM VESSEL CRANE,ONE ANCHOR MUST BE ABLE TO BE IMMEDIATLY DROPPED WITHOUT VESSEL POWER.
Condition: Unknown
Due 10 July 1990
Resolved 10 July 1990
Unknown
Issued 10 July 1990
Resolved
REPLACE TWO FRACTURED WASH BASINS IN ACCOMMODATION SPACES.
Condition: Unknown
Due 10 July 1990
Resolved 10 July 1990