CALYPSO

CALYPSO is a 1995 passenger vessel (inspected). The Coast Guard has recorded 21 inspections since 2016, most recently in April 2026, along with 40 deficiencies.

Records from 2016 to 2026. Most recent: inspection, 8 April 2026.

Built
1995
Last inspected
8 April 2026
Documentation
Expired · documentation file of 10 August 2026
Controls
None recorded without a removal date

Everything above is free. The detail below — the inspection history, the deficiency record and the documentation record — is Professional, $39 a month. Sign in.

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 8 April 2026
Operational controls None recorded without a removal date
Years with a record 11 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDG9557
286002
Flag
UNITED STATES
Maury page id
psix-286002

Documentation record

Registered dimensions (L × B × D)50.0 ft × 14.0 ft × 3.0 ft
Registered tonnagegross 14 / net 11
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderWILLARD MARINE INCORPORATED · ANAHEIM, CA, UNITED STATES · built 1995
Hull materialFRP (Fiberglass)
PropulsionDiesel Direct
Hull shapeShip
Hull configurationMonohull
Hailing portROCKY MOUNT, MO
Trade endorsementsCoastwise, unrestricted, Recreational
DocumentationExpired · issued 6 December 2012
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it14 - Simplified, Gross Ton
11 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
Detail on this page

21 inspections, each with its date, unit and type; 40 deficiencies with the resolution recorded against each; the documentation record: dimensions, tonnage, builder, hailing port, endorsements, dates. The counts in the summary above are the same counts, and they are free.

$39 a month or $299 a year, every vessel page, cancel any time. Founding rate $19.99 a month for life, for the first 200 subscribers. Plans Sign in

Maury does not score, rate or grade vessels, at any price.

Vessel history report

A report is not offered for this hull. Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 21

8 April 2026 Deficiency Check · Administrative Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 8320943
30 October 2025 DAPI Audit · Annual Inspection · Administrative Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 8178516
30 October 2025 DAPI Audit
Administrative · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 8268265
23 April 2025 Deficiency Check
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 8256789
17 October 2024 Annual Inspection · Administrative Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 8020844
2 August 2023 Drydock Extension · Hull Examination · Deficiency Check · Internal Structural Exam · COI Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 7758678
28 September 2022 Annual Inspection · Deficiency Check
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 7568732
23 September 2021 Deficiency Check · Annual Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 7318367
22 April 2021 Deficiency Check
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 7188203
29 October 2020 Annual Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 7084517
21 October 2019 Administrative Inspection · Annual Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 6838633
17 October 2018 Hull Examination · Deficiency Check · Administrative Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 6566005
27 August 2018 Deficiency Check · COI Inspection · Administrative Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 6524419
10 April 2018 Drydock Extension · Administrative Inspection
Administrative · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 6390261
30 March 2018 Deficiency Check · Administrative Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 6388286
12 October 2017 Annual Inspection · Administrative Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 6286196
6 June 2017 Administrative Inspection · Deficiency Check
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 6167811
23 November 2016 Administrative Inspection · Deficiency Check
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 6047432
17 October 2016 Annual Inspection · Administrative Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 6023932
4 June 2016 Special · Administrative Inspection
Administrative · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 5898723
18 April 2016 Deficiency Check · Administrative Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 5857966

Deficiency record · 40

13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 30 October 2025 Resolved
Vessel required to have gauges to indicate engine revolutions per minute (RPM), jacket water discharge temperature, and lubricating oil pressure must be provided for all propulsion engines installed in the vessel. Both RPM gauges, both lube oil gauges, and starboard water temp gauge inoperable.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 5 May 2026
Resolution: Vessel rep proved proper operation of vessel gauges located at operatoring station.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 30 October 2025 Resolved
The owner or managing operator shall submit drawings, sketches, or written specifications describing the details of any proposed alterations to the cognizant [name withheld] to fuel supply system for main diesel engines were made without submitting a proposal for the fuel system alterations to the OCMI.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 5 May 2026
Resolution: Electrical plan modification submitted for USCG/OCMI/MSC review.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 17 October 2024 Resolved
All machinery and equipment must be installed and maintained in such a manner as to afford adequate protection from causing fire. Fuel leak found on port engine.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 23 April 2025
Resolution: Fuel lines visually inspected by attendng Marine Inspector.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 17 October 2024 Resolved
All machinery and equipment must be installed and maintained in such a manner as to afford adequate protection from causing machinery failure. Tighten all engine mount bolts to manufacturer specs.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 23 April 2025
Resolution: Engine mounts visually inspected by attending Marine Inspector.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 11 September 2023 Resolved
Remote fuel shutoff stations must be marked in clearly legible letters at least 1 inch high indicating purpose of the valve and direction of operation. Station was not clearly marked.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 October 2023
Resolved 31 October 2023
Resolution: Cleared with pics
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 11 September 2023 Resolved
The installation and location must be to the satisfaction of the Officer In Charge, Marine Inspector. FWD Fire extinguisher did not fit in installed bracket.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 October 2023
Resolved 31 October 2023
Resolution: Cleared with pics
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 28 September 2022 Resolved
All machinery must be maintained to afford adequate protection from causing fire, explosion, machinery failure, and personnel injury. 04 fuel return fittings on MDEs weren't installed as designed.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 October 2022
Resolved 31 October 2022
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 28 September 2022 Resolved
A vessel must be operated in such a manner as to afford adequate protection against hazards that might endager the vessel. Port lower toggle on foremast is sprung.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 October 2022
Resolved 31 October 2022
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 23 September 2021 Resolved
Inspection found high pressure fuel lines on PORT engine were not properly secured within manufacture bracket supports. Flexible hose fuel lines on STBD engine showing signs of deterioration. Prove to the satisfaction of the Coast Guard marine inspector that both engines fuel lines are properly supported within brackets and flexible hoses are corrected.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 October 2021
Resolved 26 October 2021
Resolution: Cleared to the satisfaction of the Coast Guard marine inspector.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 23 September 2021 Resolved
A vessel on a lakes, bays, and sounds, or rivers route must carry: three hand red flare distress signals and three hand orange smoke distress signals. Inspection found zero distress signals onboard the vessel. Prove to the satisfaction of the Coast Guard marine inspector that flare distress signals are onboard the vessel.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 October 2021
Resolved 26 October 2021
Resolution: Cleared to the satisfaction of the Coast Guard marine inspector.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 29 October 2020 Resolved
The owner or managing operator must provide satisfactory evidence of the required servicing of the pre-enginered system to the marine inspector.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 22 April 2021
Resolution: Cleared to the satisfaction of the Coast Guard marine inspector.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 29 October 2020 Resolved
Ensure child size life jackets equal number of onboard child passengers.
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Resolved 22 April 2021
Resolution: Cleared to the satisfaction of the Coast Guard marine inspector.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 29 October 2020 Resolved
Make passenger count placard for upper bow deck legible.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 29 October 2020
Resolved 29 October 2020
Resolution: The deficiency was cleared to the satisfaction of the USCG Marine Inspector.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 12 November 2019 Resolved
During operational testing of PORT engine marine inspector discovered jacket water (coolant) leak on the pipping system located on top on the engine. Owner/operator make repairs to stop leak to the satisfaction of the attending marine inspector.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 December 2019
Resolved 12 November 2019
Resolution: The deficiency was cleared to the satisfaction of the attending USCG Marine Inspector.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 12 November 2019 Resolved
Starboard engine lube oil hose located on the reduction gear was deteriorated. Owner/operator replace flexible nonmetallic hose to meet SAE J-1942. Flexible nonmetallic hose must be complete with factory-assembled end fittings requiring no further adjustment of the fittings on the hose, or field attachable type fittings may be used. Hose end fittings must comply with SAE J-1475. Installation must be to the satisfaction of the attending marine inspector.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 December 2019
Resolved 27 December 2019
Resolution: The deficiency was cleared to the satisfaction of a USCG Marine Inspector.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 12 November 2019 Resolved
A vessel must carry a first-aid kit. Marine inspector discussed first-aid kit to have expired items. Owner/operator replace expired items to the satisfaction of the attending marine inspector.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 December 2019
Resolved 27 December 2019
Resolution: The deficiency was cleared to the satisfaction of a USCG Marine Inspector.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 12 November 2019 Resolved
During operation testing of electric bilge pump, marine inspector found system inoperable. Owner/operator corrected issues on the spot with marine inspector and found correction satisfactory.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 12 November 2019
Resolved 27 December 2019
Resolution: The deficiency was cleared to the satisfaction of the attending USCG Marine Inspector.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 17 October 2018 Resolved
Remove propane tank used for cannon prop from vessel.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 18 October 2018
Resolved 18 October 2018
Resolution: Propane was removed from vessel.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 17 October 2018 Resolved
Vessels forward and aft mast rigging shroud toggles were missing cotter pins and/or utilizing cotter pins of dissimiliar metals. Survey vessels rigging and verify all shroud toggles and any additional components are in accordance with the approved plans. Although not a traditional sailing vessel it's recommended that the owner/operator adopt NVIC 02-16 as guidance to proactively maintain, survey, and record keep maintenance on both masts, rigging and associated equipment.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 17 November 2018
Resolved 23 January 2019
Resolution: Deficiencies have been corrected to the satisfaction of the attending Marine Inspector.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 17 October 2018 Resolved
Provide plan to replace improperlly installed back stay chain plate.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 17 November 2018
Resolved 8 January 2019
Resolution: Back stay chain plate was reinforced with through nut and bolts.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 17 October 2018 Resolved
Repair bow gate latch to prevent accidental opening and to strengthen railing.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 November 2018
Resolved 8 January 2019
Resolution: Bow gate latch was replaced and one additional latch was added for additional security.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 6 September 2018 Resolved
Prove proper operation of pre-engineered fire suppression system override.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 7 September 2018
Resolution: Pre-engineered fire suppression system override functions as required.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 6 September 2018 Resolved
Provide fire suppression servicing report.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 7 September 2018
Resolution: Fire suppression servicing report provided.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 6 September 2018 Resolved
Prove proper operation of propulsion engines. Rectify starboard engine fuel issue.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 7 September 2018
Resolution: Starboard engine operated properly
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 6 September 2018 Resolved
Secure propulsion engine fuel hoses.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 September 2018
Resolved 7 September 2018
Resolution: Fuel hoses were secured.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 6 September 2018 Resolved
Make permanent repairs to port engine inboard leaking jacket water manifold.
Condition: Design Flaw
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 September 2018
Resolved 17 October 2018
Resolution: O/O replaced leaking manifold with new.
01 - Certificates & Documentation › 013 - Documents › Signs, indications
Issued 6 September 2018 Resolved
Renew upper deck passenger count placard.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 September 2018
Resolved 7 September 2018
Resolution: Placards were renewed.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 6 September 2018 Resolved
Provide documentation for EAP supervisor training.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 October 2018
Resolved 17 October 2018
Resolution: Owner provided evidence of EAP training.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 6 September 2018 Resolved
Prove proper operation of bilge pump indicator lights at operating station.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 September 2018
Resolved 17 October 2018
Resolution: Witnessed proper operation of bilge audible and visual alarms
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 6 September 2018 Resolved
Unstep and make mast hinge plates and fittings ready for inspection at next hull exam prior to 31OCT2018.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 31 October 2018
Resolved 17 October 2018
Resolution: Owner/operator un-stepped mast for inspection during hull exam.
Engineering › Bilge Water Management System › Pump
Issued 17 October 2017 Resolved
Ensure amidships submersible bilge pump and high water alarm are operational.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 October 2017
Resolved 30 March 2018
Resolution: Submersible bilge pump replaced.
Lifesaving › Lifebuoys › Serviceable
Issued 17 October 2017 Resolved
Replace weathered ring buoy and lifeline. Also ensure waterlight is configured IAW 46 CFR 180.70.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 October 2017
Resolved 30 March 2018
Resolution: Ring buoy replaced.
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 17 October 2017 Resolved
Properly secure the aft deck attachment plate for the faux aft mast to the deck.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 October 2017
Resolved 30 March 2018
Resolution: Mast mounting plate secured to deck.
Fire Fighting › Portable CO2 Fire Extinguisher › Number
Issued 17 October 2017 Resolved
Properly install a B-II fire extinguisher.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 31 October 2017
Resolved 30 March 2018
Resolution: B-II extinguisher mounted.
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 25 October 2016 Resolved
It was discovered that wood planking in way of the operating station on upper deck which is accessible to passengers was dry rotted and holed.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 25 December 2016
Resolved 6 June 2017
Resolution: Received email verification and photos of wood planking.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 25 October 2016 Resolved
While conducting an operational test of the water light attached to the life ring buoy, it was discovered that the water light was inoperable.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 25 November 2016
Resolved 23 November 2016
Resolution: Received email verification of deficiency correction.
Electrical › Electric Supply System (service) › Cable
Issued 25 October 2016 Resolved
While conducting a general housekeeping inspection of the main deck, forward hold compartment, an unused (dead) electrical fixture was hanging from the overhead. A second unused (dead) wiring circuit was also discovered in this same compartment.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 25 November 2016
Resolved 23 November 2016
Resolution: Received email verification of deficiency correction.
Documentation › Markings/Placards › Warning Signs
Issued 25 October 2016 Resolved
It was discovered that signage indicating the number of passengers allowed on upper deck (port and starboard sides) was faded and illegible.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 25 November 2016
Resolved 23 November 2016
Resolution: Received email verification of deficiency correction.
Fire Fighting › Fixed Gas Fire Extinguishing System › Quantity of Gas
Issued 25 October 2016 Resolved
While conducting the inspection of the pre-engineered fixed system in the engine compartment, the O/O could not present documentation attesting to specific servicing details (inspection tag on system was not past due).
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 25 November 2016
Resolved 23 November 2016
Resolution: Received email verification of deficiency correction.
Documentation › Manuals/Policy Documentation › Stability Instructions
Issued 4 June 2016 Resolved
1) Remove all added lateral surface (sail area) that was installed since the completion of the simplified stability test (SST) conducted on 29AUG13. These items include,but are not limited to, the retractable canopy, the company banner, and the sails strung between the fore and aft yardarms.
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Due 4 June 2016
Resolved 4 June 2016
Resolution: Equipment removed and/or stowed.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.