Records from 1987 to 2026. Most recent: inspection, 18 March 2026.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 76
18 March 2026
COI Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8317704
8 December 2025
Drydock Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8266599
6 May 2025
Damage Survey · Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8129321
26 March 2025
Administrative Inspection · Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8100216
9 April 2024
Annual Inspection · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7894162
28 November 2023
Administrative Inspection · Drydock Exam · In-Service Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7830611
27 February 2023
Administrative Inspection · Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7634802
25 January 2022
Administrative Inspection · Annual Inspection · Examination of Repairs
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7385353
7 July 2021
Drydock Exam · Hull Examination · In-Service Inspection · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7251064
3 May 2021
Administrative Inspection · Simplified Stability Test
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7188074
23 March 2021
COI Inspection · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7161174
9 April 2020
Administrative Inspection · Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6937437
26 February 2020
Administrative Inspection · Deficiency Check · Drydock Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6916336
17 September 2019
In-Service Inspection · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6814196
25 February 2019
DAPI Audit · Annual Inspection · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6631860
23 July 2018
Deficiency Check · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6489705
3 April 2018
Administrative Inspection · DAPI Audit · Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6384104
23 February 2018
Hull Examination · Internal Structural Exam · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6360590
2 May 2017
Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6137604
8 March 2017
Administrative Inspection · Annual Inspection · DAPI Audit
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6101101
8 June 2016
Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5900927
14 April 2016
Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5854494
18 February 2016
Administrative Inspection · COI Inspection · DAPI Audit
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5817825
18 February 2016
Administrative Inspection · Internal Structural Exam · Hull Examination
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5817837
19 May 2014
Simplified Stability Test
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 4848891
5 March 2014
Internal Structural Exam · Hull Examination
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 4793476
8 February 2011
Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3937644
9 March 2010
Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3688429
11 February 2010
Hull Examination
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3672099
7 May 2009
Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3467406
18 March 2009
Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3420563
28 March 2008
Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3173260
13 March 2008
Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3139750
13 February 2008
Internal Structural Exam · Hull Examination
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3139830
8 March 2007
Examination of Repairs · COI Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 2883982
7 February 2006
Annual Inspection · Hull Examination
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 2594467
9 June 2005
Re-Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 2384495
7 July 2004
Plan Review "T" Boat
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 2124564
21 April 2004
Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 2048685
18 February 2004
Hull Examination
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 2008341
14 May 2003
Deficiency Check
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 1819914
21 April 2003
Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 1776119
8 April 2002
COI Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 1603593
21 February 2002
Hull Examination
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 1488424
10 April 2001
Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1066451
3 April 2001
Deficiency Check · Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1061520
26 May 2000
Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 822574
7 March 2000
Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1427838
27 June 1999
Administrative
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1078728
15 May 1999
Deficiency Check · COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1471560
4 November 1998
Plan Review "T" Boat
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1034674
19 May 1998
Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1473272
24 February 1998
Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1404525
22 April 1997
Re-Inspection · Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1446569
30 July 1996
Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1089525
7 May 1996
COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1442392
7 March 1996
Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1360436
27 June 1995
Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1424126
17 May 1994
Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 866067
28 April 1994
Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 866200
23 June 1993
Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 842806
16 June 1993
Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 962861
9 June 1993
COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1144096
20 April 1993
Administrative
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1150276
3 June 1992
Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 958692
13 May 1992
Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1270623
12 May 1992
Administrative
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1265233
24 September 1991
Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1248974
18 July 1991
Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1245959
6 June 1990
COI Inspection · Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 903841
30 May 1990
Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 906943
30 May 1989
Re-Inspection · Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1206347
15 December 1988
Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1340505
14 June 1988
Deficiency Check · Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1204803
4 November 1987
Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1334441
22 June 1987
Hull Examination · Initial Certification
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1002052
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 27 February 2023
Resolved
Every vessel subject to Part III of Title III of the Communications Act must have a detailed inspection of the radio installation by an FCC-licensed technician in accordance with § 80.59 once every five years. The vessel's Radiotelephony Safety Certificate expired in April 2022. Limited to operations within 1000' from shore.
Action required: 705 - Other - as specified
Resolved 10 March 2023
Resolution: Received picture of Radio Safety Certificate from vessel rep.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 23 February 2022
Resolved
Vessel must comply with structural design requirements of the standard for fiber reinforced plastic vessels. Fore-peak had vertical stringers that had become delaminated from each other and need to be affixed to the upper decking.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 9 March 2022
Resolved 7 March 2022
Resolution: Photographic evidence provided of repairs, all sat.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 25 January 2022
Resolved
Vessel must comply with structural design requirements of the standard for fiber reinforced plastic vessels. Two cleats were missing.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 9 March 2022
Resolved 7 March 2022
Resolution: Cleats were reinstalled.
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 23 April 2018
Resolved
Provide proof of DAPI enrollment and supervisor training.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 May 2018
Resolved 23 July 2018
Resolution: Master provided proof of DAPI enrollment and supervisor training.
Lifesaving › Buoyant Apparatus › Floating Electric Waterlight
Issued 23 April 2018
Resolved
Replace batteries in 03 floating lights.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 May 2018
Resolved 23 July 2018
Resolution: Batteries replaced in 03 floating lights.
Communications › Radio Communications › VHF Radiotelephone
Issued 23 April 2018
Resolved
Install GPS to DSC.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 May 2018
Resolved 23 July 2018
Resolution: GPS installed to DSC.
Operations/Management › Equipment Service/Testing › EPIRB
Issued 26 April 2017
Resolved
EPIRB registration sticker not provided.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 24 May 2017
Resolved 2 May 2017
Resolution: Provided proof of registration for EPIRB
Communications › Radio Communications › VHF Radiotelephone
Issued 26 April 2017
Resolved
VHF/DSC radio not connected to GPS.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 24 May 2017
Resolved 2 May 2017
Resolution: Provided proof of GPS connection to VHF/DSC, new radio installed on vessel
Operations/Management › Drug and Alcohol Testing › EAP Training Requirements
Issued 29 March 2016
Resolved
46 CFR 16.401: The EAP training program must include documentation of training given to crew members and the employers supervisory personnel. Provide documentation of required training program.
Condition: Invalid
Action required: 705 - Other - as specified
Due 26 April 2016
Resolved 8 June 2016
Resolution: EAP Supervisor training completion certificate provided.
Fire Fighting › Fixed Fire Detection System › Smoke Detectors
Issued 29 March 2016
Resolved
46 CFR 181.450: Each overnight accommodation space on a vessel must be fitted with an independent modular smoke detecting alarm that meets UL217 or "suitable for uses in Recreational Vehicles". Provide proof smoke detectors meet the required standard.
Condition: Invalid
Action required: 705 - Other - as specified
Due 12 April 2016
Resolved 14 April 2016
Resolution: Installed RV approved smoke detector.
Electrical › Lighting (emergency) › Lighting Fixture
Issued 29 March 2016
Resolved
Emergency lighting in accommodation space was inop. Make emergency lighting operable IAW 46 CFR 183.432.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 12 April 2016
Resolved 14 April 2016
Resolution: INstalled and tested emergency lighting.
Documentation › Certificates/Documents › FCC SSL
Issued 2 May 2011
Resolved
Provide a valid Radio Safety Certificate.
Action required: 705 - Other - as specified
Resolved 16 June 2011
Operations/Management › Drills/Instruction › Not Conducted
Issued 2 May 2011
Resolved
Provide a training log as per 46 CFR 185.420
Action required: 705 - Other - as specified
Resolved 16 June 2011
Accommodation/Occupational Safety › Refrigeration (air conditioning) › General
Issued 2 May 2011
Resolved
Properly install a/c duct in fed berthing and install a diffuser.
Action required: 705 - Other - as specified
Resolved 16 June 2011
Electrical › Lighting (emergency) › Lighting Fixture
Issued 2 May 2011
Resolved
Prove proper operation of emergency light in berthing area.
Action required: 705 - Other - as specified
Resolved 16 June 2011
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 2 May 2011
Resolved
Replace deteriorated /broken water light on ring buoy.
Action required: 705 - Other - as specified
Resolved 16 June 2011
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 2 May 2011
Resolved
Properly label the life jacket stowage in berthing area.
Action required: 705 - Other - as specified
Resolved 16 June 2011
Lifesaving › Buoyant Apparatus › Pendant
Issued 2 May 2011
Resolved
Properly attach the paddles to the life floats.
Action required: 705 - Other - as specified
Resolved 16 June 2011
Construction/Loadline › Structures › Scuttle
Issued 2 May 2011
Resolved
Provide and install a cap for the hawser pipe on bow.
Action required: 705 - Other - as specified
Resolved 16 June 2011
Electrical › Electric Generation Source (service) › Metallic Enclosure/Frame
Issued 2 May 2011
Resolved
Provide and install guard over rotating machinery on generator.
Action required: 705 - Other - as specified
Resolved 16 June 2011
Electrical › Electric Generation Source (service) › Overcurrent Device
Issued 2 May 2011
Resolved
Provide and post a derating placard on ship service generator.
Action required: 705 - Other - as specified
Resolved 16 June 2011
Engineering › Fuel Oil Service System › Valve, Control
Issued 9 March 2010
Resolved
Provide and install fuel shut-off valvess at both main engines and generator.
Action required: 705 - Other - as specified
Due 9 April 2010
Resolved 15 April 2010
Resolution: Shut off valves were installed at both main engines and generator as required.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 9 March 2010
Resolved
Provide 3rd party service report for fixed fire system.
Action required: 705 - Other - as specified
Due 9 April 2010
Resolved 15 April 2010
Resolution: Vessel owner provided satisfactory 3rd party servicing report.
Deck/Cargo › Holds/Tanks › Hatch
Issued 11 February 2010
Resolved
Prove operation of all hatches.
Action required: 705 - Other - as specified
Due 11 March 2010
Resolved 9 March 2010
Resolution: Proved operation of all hatches.
Construction/Loadline › Hull › Side Shell
Issued 11 February 2010
Resolved
Make repairs to fracture in FRP IWO cap rail on starboard side.
Action required: 705 - Other - as specified
Due 11 March 2010
Resolved 9 March 2010
Resolution: Made repairs to FRP IWO cap rail on starboard side.
Construction/Loadline › Penetrations › Valve Flange
Issued 11 February 2010
Resolved
Provide and install a valve at through-hull penatrations throughtout the vessel.
Action required: 705 - Other - as specified
Due 11 March 2010
Resolved 9 March 2010
Resolution: Installed valve at through-hull pendatrations.
Stability › Weathertight Integrity › General
Issued 11 February 2010
Resolved
Replace missing window on starboard side of super structure.
Action required: 705 - Other - as specified
Due 11 March 2010
Resolved 9 March 2010
Resolution: Replaced missing window on starboard side of super structure.
Lifesaving › Lifejacket/PFD (General) › Condition
Issued 31 March 2009
Resolved
Replace rejected lifejackets per 46 CFR 180.71. Vessel shall operate with no more than 44 adults on board until cleared.
Action required: 705 - Other - as specified
Due 1 May 2009
Resolved 7 May 2009
Resolution: Lifejackets were replaced.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 31 March 2009
Resolved
Replace expired burn gel packs in first aid kit per 46 CFR 184.710.
Action required: 705 - Other - as specified
Due 1 May 2009
Resolved 7 May 2009
Resolution: Replaced burn gel packages.
Electrical › Lighting (service) › Lighting Fixture
Issued 31 March 2009
Resolved
Provide bulbs and cover for light fixture in engine room per 46 CFR 176.800.
Action required: 705 - Other - as specified
Due 1 May 2009
Resolved 7 May 2009
Resolution: Replaced complete lighting fixture
Engineering › Freshwater System (jacketwater cooling) › Hose
Issued 31 March 2009
Resolved
Replace deteriorated cooling water hose on port main engine per 46 CFR 182.20-10.
Action required: 705 - Other - as specified
Due 1 May 2009
Resolved 7 May 2009
Resolution: Replaced hose
Engineering › Lubricating Oil Service System › Valve
Issued 31 March 2009
Resolved
Make repairs to both the port and stbd main engines to secure lube oil leaks per 46 CFR 182.01-5.
Action required: 705 - Other - as specified
Due 1 May 2009
Resolved 7 May 2009
Resolution: Installed new gasket material to alleviate leaks
Engineering › Fuel Oil Service System › Filter
Issued 31 March 2009
Resolved
Replace plastic plug in bottom of fuel filter on port main engine per 46 CFR 182.01-5.
Action required: 705 - Other - as specified
Due 1 May 2009
Resolved 7 May 2009
Resolution: Replaced plug with steel bolt
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 31 March 2009
Resolved
Properly support inboard exhaust for stbd main engine per 46 CFR 182.20-20.
Action required: 705 - Other - as specified
Due 1 May 2009
Resolved 7 May 2009
Resolution: Exhaust supported by wooden boards. Boards have been fastened to hull and will be fiber glassed in at a later date.
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 31 March 2009
Resolved
Prove proper operation of override switch for the fixed fire extinguishing system in engine room per 46 CFR 181.04-20.
Action required: 705 - Other - as specified
Due 1 May 2009
Resolved 7 May 2009
Resolution: Override switch worked properly.
Operations/Management › Vessel Safety Management › Emergency Preparedness
Issued 31 March 2009
Resolved
Post emergency broadcast placard at radio installations per 46 CFR 184.506.
Action required: 705 - Other - as specified
Due 1 May 2009
Resolved 7 May 2009
Resolution: New emergency broadcast placard provided and installed
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 31 March 2009
Resolved
Replace expired battery in both lifefloat waterlights per 46 CFR 180.175.
Action required: 705 - Other - as specified
Due 1 May 2009
Resolved 7 May 2009
Resolution: Batteries were replaced.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 31 March 2009
Resolved
Replace expired battery on lifebuoy waterlight per 46 CFR 180.70.
Action required: 705 - Other - as specified
Due 1 May 2009
Resolved 7 May 2009
Resolution: Batteries were replaced
Engineering › Bilge Water Management System › Piping
Issued 31 March 2009
Resolved
Secure flange on fixed bilge piping in way of bulkhead penetration per 46 CFR 176.800.
Action required: 705 - Other - as specified
Due 1 May 2009
Resolved 7 May 2009
Resolution: Flange has been properly secured.
Lifesaving › Lifefloat › Painter
Issued 31 March 2009
Resolved
Provide and install painter lines on lifefloats per 46 CFR 180.175.
Action required: 705 - Other - as specified
Due 1 May 2009
Resolved 7 May 2009
Resolution: Sea painter lines have been installed and spliced properly.
Stability › Watertight Integrity › General
Issued 18 March 2009
Resolved
Replace gasket on window on port side of bridge per 46 CFR 176.800.
Action required: 705 - Other - as specified
Due 1 May 2009
Resolved 7 May 2009
Resolution: Window gasket has been replaced.
Navigation › Piloting/Steering › Tide/Tidal Current Tables
Issued 13 March 2008
Resolved
Provide up to date Coast Pilot [name withheld], and Current Tables as per 46 CFR 184.420.
Due 13 April 2008
Resolved 26 March 2008
Resolution: All navigation pubs are up to date.
Documentation › Certificates/Documents › FCC SSL
Issued 13 March 2008
Resolved
Provide an FCC Station License as per 47 CFR 80.13.
Due 13 April 2008
Resolved 26 March 2008
Resolution: A valid Station License has been provided.
Documentation › Certificates/Documents › FCC SSL
Issued 13 March 2008
Resolved
Provide an FCC Marine Radio Operator Permit as per 47 CFR 80.159.
Due 13 April 2008
Resolved 29 April 2008
Resolution: Master provided a valid Radio Operator Permit.
Lifesaving › Lifefloat › Painter
Issued 13 March 2008
Resolved
Replace the line on the bottom life float as per 46 CFR 180.175.
Due 13 April 2008
Resolved 29 April 2008
Resolution: The line on the life float has been properly replaced.
Accommodation/Occupational Safety › Other Accommodation Spaces › Open Deck Space
Issued 13 March 2008
Resolved
Replace the broken glass on the door for the pilot house as per 46 CFR 176.830.
Due 13 April 2008
Resolved 26 March 2008
Resolution: The broken glass has been repaired.
Navigation › Piloting/Steering › Deviation Table/Graph
Issued 13 March 2008
Resolved
Provide compass deviation tables for the magnetic compass as per 46 CFR 184.402.
Due 13 April 2008
Resolved 26 March 2008
Resolution: Deviation tables have been provided.
Engineering › Shafting/Propeller Arrangements › Propeller Shaft
Issued 13 February 2008
Resolved
Grind out existing welds in way of the port and starboard shaft struts supports and reweld with new weld metal
Action required: 705 - Other - as specified
Due 14 February 2008
Resolved 14 February 2008
Construction/Loadline › Structures › Manhole
Issued 13 February 2008
Resolved
Provide and attach a lanyard to the forepeak and steering compartment watertight hatch covers.
Action required: 705 - Other - as specified
Due 14 February 2008
Resolved 14 February 2008
Engineering › Shafting/Propeller Arrangements › Bearing
Issued 13 February 2008
Resolved
Renew the forward and aft shaft cutlass bearings on the starboard shaft.
Action required: 705 - Other - as specified
Due 14 February 2008
Resolved 14 February 2008
Construction/Loadline › Structures › Transverse Bulkhead
Issued 13 February 2008
Resolved
Properly seal up all bulkhead penertrations in the forward and aft bulkheads in the fuel oil tank space.
Action required: 705 - Other - as specified
Due 14 February 2008
Resolved 14 February 2008
Engineering › Fuel Oil Storage/Transfer System › Piping
Issued 29 March 2007
Resolved
Make all piping penetrations on fuel oil tank tight and leak free. Protect fuel piping on top of tank from mechanical injury and secure effectively against excessive movement and vibration. (46 CFR 182.455) (Temporary repairs effected on 29 MAR 2007. Permanent repair to be made to the satisfaction of an attending marine inspector not later than 29 APRIL 2007).
Condition: Unknown
Action required: 705 - Other - as specified
Due 27 April 2007
Resolved 18 May 2007
Resolution: Made piping penetrations on fuel oil tank tight and leak free. Properly protected and secured fuel piping on top of tank from mechanical injury.
Engineering › Lubricating Oil Service System › Hose
Issued 8 March 2007
Resolved
Replace port engine lube oil filter inlet/outlet hoses and properly mount lube oil filter. (46 CFR 182.720)
Condition: Unknown
Action required: 705 - Other - as specified
Due 6 April 2007
Resolved 29 March 2007
Engineering › Diesel Engine (propulsion-reduction gear) › Air Cleaner
Issued 8 March 2007
Resolved
Route port/stbd engine crankcase breather vent pipes to air intakes. (46 CFR 176.800)
Action required: 705 - Other - as specified
Due 6 April 2007
Resolved 29 March 2007
Engineering › Sea-water System (primary cooling) › Piping
Issued 8 March 2007
Resolved
Repair auxiliary generator seawater cooling inlet piping in way of hull penetration. (46 CFR 176.800)
Condition: Unknown
Action required: 705 - Other - as specified
Due 6 April 2007
Resolved 29 March 2007
Engineering › Bilge Water Management System › Piping
Issued 8 March 2007
Resolved
Tighten and secure loose pipe fittings on vessel's fixed bilge piping systems and demonstrate proper system operation in the presence of a marine inspector. (46 CFR 182.510)
Condition: Unknown
Action required: 705 - Other - as specified
Due 6 April 2007
Resolved 29 March 2007
Fire Fighting › Fire Pumps › Arrangement
Issued 8 March 2007
Resolved
Conduct operational test of fixed power fire pump and pressure test hose in the presence of a marine inspector. (46 CFR 181.300)
Action required: 705 - Other - as specified
Due 6 April 2007
Resolved 29 March 2007
Engineering › Fuel Oil Storage/Transfer System › Valve
Issued 8 March 2007
Resolved
[name withheld] Fuel Oil shut off valve as required by 46 CFR 185.608.
Action required: 705 - Other - as specified
Due 6 April 2007
Resolved 29 March 2007
Engineering › Fuel Oil Storage/Transfer System › Hose
Issued 8 March 2007
Resolved
Replace fuel oil tank fill flex hose assemblies and install bonding cables as required by 46 CFR 182.445.
Action required: 705 - Other - as specified
Due 6 April 2007
Resolved 29 March 2007
Engineering › Fuel Oil Storage/Transfer System › Filter/Strainer
Issued 8 March 2007
Resolved
Clean/servcie propulsion engine fuel oil strainers. (46 CFR 176.800)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 6 April 2007
Resolved 29 March 2007
Electrical › Electrical Distribution System (service) › Conductor
Issued 8 March 2007
Resolved
Terminate conductor butt connections for electric submersible pumps and high bilge level alarms to suitable enclosure in accordance with 46 CFR 183.340.
Action required: 705 - Other - as specified
Due 6 April 2007
Resolved 29 March 2007
Operations/Management › Drills/Instruction › Fire
Issued 8 March 2007
Resolved
Perform satisfactory Fire, Man Overboard and Abandon Ship drills as required by 46 CFR Part 176, Subpart H in the presence of the attending Marine Inspector.
Action required: 705 - Other - as specified
Due 6 April 2007
Resolved 29 March 2007
Lifesaving › Lifejacket/PFD (General) › Quantity
Issued 8 March 2007
Resolved
Provide 02 Adult Type I PFDs in serviceable condition approved under 46 CFR 160.055 in accordance with 46 CFR 180.71 and marked in accordance with 46 CFR 185.604
Action required: 705 - Other - as specified
Due 6 April 2007
Resolved 29 March 2007
Documentation › Logs/Records › Logbook/Record (unofficial)
Issued 8 March 2007
Resolved
Record general description of training completed for crew familiarization, fire, man overboard and abandon ship drills as required be 46 CFR 185.402.
Action required: 705 - Other - as specified
Due 6 April 2007
Resolved 29 March 2007
Navigation › Piloting/Steering › Coast Guard Light List
Issued 8 March 2007
Resolved
Provide current copies or excerpts from navigation safety publications and a navigational chart for area of intended operations required by 46 CFR 184.420
Action required: 705 - Other - as specified
Due 6 April 2007
Resolved 29 March 2007
Construction/Loadline › Structures › Superstructure
Issued 8 March 2007
Resolved
Repair broken safety glass in pilot house. (46 CFR 176.800)
Action required: 705 - Other - as specified
Due 6 April 2007
Resolved 29 March 2007
Lifesaving › Lifefloat › Serviceable
Issued 8 March 2007
Resolved
Service lifefloat and stow in accordance with 46 CFR 180.130.
Action required: 705 - Other - as specified
Due 6 April 2007
Resolved 29 March 2007
Lifesaving › Lifejacket/PFD (Type I) › Lights
Issued 8 March 2007
Resolved
Replace expired chemical lights on 20 adult TYPE 1 PFDs as required by 46 CFR 180.75.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 6 April 2007
Resolved 29 March 2007
Lifesaving › Lifebuoys › Stowage
Issued 8 March 2007
Resolved
Provide a 3 foot lanyard and corrosion resistant clip for life ring buoy as required by 46 CFR 180.70.
Action required: 705 - Other - as specified
Due 6 April 2007
Resolved 29 March 2007
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 8 March 2007
Resolved
Demonstrate proper operation of machinery space pre-engineered fixed gas fire fighting system automatic shut down device for the starboard diesel engine as required by 46 CFR 181.420.
Action required: 705 - Other - as specified
Due 6 April 2007
Resolved 29 March 2007
Engineering › Lubricating Oil Service System › Hose
Issued 8 March 2007
Resolved
Replace starboard propulsion engine lube oil cooler flex hose. (46 CFR 182.720)
Action required: 705 - Other - as specified
Due 6 April 2007
Resolved 29 March 2007
Operations/Management › Drills/Instruction › Fire
Issued 7 February 2006
Resolved
Conduct crew proficiency drills as required by 46 CFR 185.520
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 7 March 2006
Resolved 9 March 2006
Documentation › Manifests/Lists › Muster List/Emergency Instructions
Issued 9 June 2005
Resolved
Post Station Bill as required by 46 CFR 185.514.
Action required: 705 - Other - as specified
Due 9 August 2005
Resolved 15 August 2005
Operations/Management › Pollution › Control of Garbage
Issued 9 June 2005
Resolved
Post waste management plan as required by 33 CFR 151.57.
Action required: 705 - Other - as specified
Due 9 July 2005
Resolved 16 June 2005
Operations/Management › Drills/Instruction › Not Conducted
Issued 9 June 2005
Resolved
Conduct crew training and drills as required by 46 CFR Part 185 and log as required by 185.420
Action required: 701 - Prior to carriage of passengers/cargo
Due 15 June 2005
Resolved 15 June 2005
Navigation › Piloting/Steering › Coast Guard Light List
Issued 9 June 2005
Resolved
Provide current copies or excerpts from navigation safety publications required by 46 CFR 184.420
Action required: 705 - Other - as specified
Due 9 July 2005
Resolved 15 July 2005
Communications › Radio Communications › EPIRB
Issued 9 June 2005
Resolved
Provide a serviceable 406 mhz CAT I EPIRB installed in a suitable float free arrangement. (46 CFR 180.15)
Action required: 701 - Prior to carriage of passengers/cargo
Due 9 July 2005
Resolved 15 June 2005
Construction/Loadline › Structures › Scuttle
Issued 9 June 2005
Resolved
Make steering compartment and peak tank hatches operable and watertight as required by 46 CFR 179.340
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 9 June 2005
Resolved 15 June 2005
Lifesaving › Lifefloat › Markings
Issued 9 June 2005
Resolved
Mark life floats with vessel name, replace water light lanyards on both floats and rig pendants as required by 46 CFR 160.010.
Action required: 701 - Prior to carriage of passengers/cargo
Due 9 June 2005
Resolved 15 June 2005
Lifesaving › Lifejacket/PFD (General) › Condition
Issued 9 June 2005
Resolved
Clean all PFD and lubricate all straps, d-rings and clips. (46 CFR 176.800).
Action required: 701 - Prior to carriage of passengers/cargo
Due 9 June 2005
Resolved 15 June 2005
Fire Fighting › Portable CO2 Fire Extinguisher › Mounting Bracket
Issued 9 June 2005
Resolved
Replace wasted mounting bracket in passenger accommodation. (46 CFR 162.028)
Action required: 701 - Prior to carriage of passengers/cargo
Due 9 June 2005
Resolved 15 June 2005
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 9 June 2005
Resolved
Install guard over auxiliary generator belt drive. (46 CFR 177.960)
Action required: 705 - Other - as specified
Due 9 July 2005
Resolved 15 June 2005
Engineering › Fuel Oil Service System › Piping
Issued 9 June 2005
Resolved
Repair leaks on generator fuel pump. (46 CFR 176.800)
Action required: 701 - Prior to carriage of passengers/cargo
Due 9 June 2005
Resolved 15 June 2005
Engineering › Freshwater System (cylinder head cooling) › Pump
Issued 9 June 2005
Resolved
Repair cooling water leaks on aux generator pump housing. (46 CFR 176.800).
Action required: 701 - Prior to carriage of passengers/cargo
Due 9 June 2005
Resolved 15 June 2005
Electrical › Electric Generation Source (service) › Conductor
Issued 9 June 2005
Resolved
Remove all dead-ended, frayed/open wire, and conductors with improper splices from auxiliary generator wiring harness. (46 CFR 183.340)
Action required: 701 - Prior to carriage of passengers/cargo
Due 9 June 2005
Resolved 15 June 2005
Communications › Alarms/Indicators › Bilge Alarm
Issued 9 June 2005
Resolved
Demonstrate proper operation of all required bilge high level alarms. (46 CFR 185.530).
Action required: 701 - Prior to carriage of passengers/cargo
Due 9 June 2005
Resolved 15 June 2005
Electrical › Lighting (emergency) › Lighting Fixture
Issued 9 June 2005
Resolved
Install emergency lighting in all passenger accommodation space located below the main deck in accordance with 46 CFR 183.432.
Action required: 705 - Other - as specified
Due 9 July 2005
Resolved 2 March 2006
Electrical › Electric Supply System (service) › Cable
Issued 21 April 2004
Resolved
Provide approved electrical plans for vessel rewire. LEGACY COMPONENT DESC: Plans
Action required: 705 - Other - as specified
Due 23 May 2004
Resolved 9 June 2005
Operations/Management › Equipment Service/Testing
Issued 21 April 2004
Resolved
Make vessel ready for inspection. LEGACY COMPONENT DESC: Overall
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 23 April 2004
Resolution: Completed.
Engineering › Bilge Water Management System
Issued 21 April 2004
Resolved
Repair fixed Bilge System and Demonstrate IAW 46 CFR 182.520. LEGACY COMPONENT DESC: Manifold
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 23 April 2004
Resolution: 835 issued under activity 2008341.
Fire Fighting › Fixed Gas Fire Extinguishing System
Issued 21 April 2004
Resolved
Demonstrate fixed fire suppression system IAW 46CFR182.465. LEGACY COMPONENT DESC: Operating Controls
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 23 April 2004
Resolution: Completed.
Construction/Loadline › Penetrations
Issued 21 April 2004
Resolved
Cap old unused overboard discharge through hull penetrations. LEGACY COMPONENT DESC: Valve Flange
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 23 April 2004
Resolution: Completed.
Engineering › Generator (propulsion/auxiliary-electric)
Issued 21 April 2004
Resolved
Demonstrate ship service diesel generator and load test. LEGACY COMPONENT DESC: Wiring
Action required: 705 - Other - as specified
Resolved 23 April 2004
Resolution: Completed.
Construction/Loadline › Structures
Issued 21 April 2004
Resolved
Repair fiberglass port side bulkhead aft accommodations area delamination. LEGACY COMPONENT DESC: Transverse Bulkhead
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 23 April 2004
Resolution: Completed.
Construction/Loadline › Structures › Transverse Bulkhead
Issued 21 April 2004
Resolved
Repair delamination of glass forward port accommodation area. LEGACY COMPONENT DESC: Superstructure
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 23 May 2004
Resolved 9 June 2005
Accommodation/Occupational Safety › Other Accommodation Spaces
Issued 21 April 2004
Resolved
Label emergency escape P & S main salon area. LEGACY COMPONENT DESC: labeling
Action required: 705 - Other - as specified
Resolved 23 April 2004
Resolution: Completed.
Engineering › Bilge Water Management System
Issued 21 April 2004
Resolved
Repair and demonstrate bilge high level alarms. LEGACY COMPONENT DESC: Interface Detector
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 23 April 2004
Resolution: Completed.
Engineering › Diesel Engine (propulsion-reduction gear)
Issued 21 April 2004
Resolved
Demonstrate main engine and generator guages. LEGACY COMPONENT DESC: Guages
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 23 April 2004
Resolution: Completed.
Accommodation/Occupational Safety › Occupational Safety
Issued 21 April 2004
Resolved
Clean debis from vessel, remove trash, and flammables. LEGACY COMPONENT DESC: Trash
Action required: 705 - Other - as specified
Resolved 23 April 2004
Resolution: Completed.
Engineering › Fuel Oil Storage/Transfer System
Issued 21 April 2004
Resolved
Label fuel emergency shut off valves. LEGACY COMPONENT DESC: Piping
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 23 April 2004
Resolution: Completed.
Fire Fighting › Fire Pumps › Arrangement
Issued 21 April 2004
Resolved
Demonstrate fire pump meets or exceeds 60 PSI at the pump. Vessel not to carry more than 49 PAX until cleared. LEGACY COMPONENT DESC: Pressure
Action required: 705 - Other - as specified
Due 23 May 2004
Resolved 9 June 2005
Electrical › Electric Supply System (service)
Issued 21 April 2004
Resolved
Strap all wire in pilot house and throught out vessel. LEGACY COMPONENT DESC: Cable
Action required: 705 - Other - as specified
Resolved 23 April 2004
Resolution: Completed.
Construction/Loadline › Hull
Issued 18 February 2004
Resolved
Repair 2nd frame located in forepeak and remove shoring bracket for sampson post where pressing on collision bulkhead. LEGACY COMPONENT DESC: Transverse Frame
Action required: 705 - Other - as specified
Resolved 23 April 2004
Resolution: Repaired frame.
Stability › Watertight Integrity
Issued 18 February 2004
Resolved
Repair forepeak hatch gasket. LEGACY COMPONENT DESC: Hatch Gasket
Action required: 705 - Other - as specified
Resolved 23 April 2004
Resolution: Renewed gasket.
Engineering › Bilge Water Management System › Piping
Issued 18 February 2004
Resolved
Replace fixed bilge piping throughout vessel where wasted and provide proper support brackets for same. Vessel not to carry more than 49 PAX until cleared. LEGACY COMPONENT DESC: Piping
Action required: 705 - Other - as specified
Due 23 May 2004
Resolved 9 June 2005
Construction/Loadline › Hull
Issued 18 February 2004
Resolved
Remove angel hair from bilge stringers in E/R overhead and treat with wood preservative and replace missing stringers. LEGACY COMPONENT DESC: Stringer
Action required: 705 - Other - as specified
Resolved 23 April 2004
Resolution: Completed.
Engineering › Diesel Engine (propulsion-reduction gear)
Issued 18 February 2004
Resolved
Repair exhaust system both main diesel engines where leaking, I.E., hose connections, E/R, fuel tank space and transom connections. LEGACY COMPONENT DESC: Piping (exhaust)
Action required: 705 - Other - as specified
Resolved 23 April 2004
Resolution: Repairs made to P & S MDE exhaust.
Engineering › Fuel Oil Service System
Issued 18 February 2004
Resolved
Repair fuel leaks on engine connections and fuel tank valves. LEGACY COMPONENT DESC: Valve
Action required: 705 - Other - as specified
Resolved 23 April 2004
Resolution: Repaired.
Engineering › Fuel Oil Service System
Issued 18 February 2004
Resolved
Provide flame screen on port main diesel engine fuel filter. LEGACY COMPONENT DESC: Flame Screen
Action required: 705 - Other - as specified
Resolved 23 April 2004
Resolution: Renewed flame screen.
Documentation › Logs/Records
Issued 21 April 2003
Resolved
Provide on board, Log Book(s) containing Lifesaving records and bridge log data IAW 46 CFR 185.702, 520 and 524. LEGACY COMPONENT DESC: Logbook (official)
Action required: 705 - Other - as specified
Due 21 May 2003
Resolved 14 May 2003
Resolution: Owner provided log books.
Navigation › Piloting/Steering
Issued 21 April 2003
Resolved
Provide on board Navigation Pubs IAW 46 CFR 184.420. LEGACY COMPONENT DESC: Inland Navigation Rules
Action required: 705 - Other - as specified
Due 21 May 2003
Resolved 14 May 2003
Resolution: Owner provided navigation publications.
Lifesaving › Rigid Liferafts
Issued 21 April 2003
Resolved
Vessel is prohibited from operation beyond 3 NM from shore after 01 May 03, or until EPIRB hydrostatic release is renewed. LEGACY COMPONENT DESC: Hydrostatic Release Unit
Action required: 705 - Other - as specified
Due 21 May 2003
Resolved 14 May 2003
Resolution: Owner renewed hydrostatic release on EPIRB.
Engineering › Bilge Water Management System
Issued 21 April 2003
Resolved
Place on each fixed bilge suction, a strainer having an open area of not less than three times the area of the bilge pipe IAW 46 CFR 182.510(b). LEGACY COMPONENT DESC: Strainer
Action required: 705 - Other - as specified
Due 21 May 2003
Resolved 14 May 2003
Resolution: Owner installed proper strainers on fixed bilge suction pipes.
Electrical › Electric Supply System (service)
Issued 21 April 2003
Resolved
Properly support all cable runs with metallic straps every two feet IAW 46 CFR 183.340(b)(4). LEGACY COMPONENT DESC: Cable
Action required: 705 - Other - as specified
Due 21 May 2003
Resolved 14 May 2003
Resolution: Owner properly supported all cable runs with metallic straps.
Engineering › Fuel Oil Storage/Transfer System
Issued 21 April 2003
Resolved
Renew bonding straps on fuel tank fills IAW 46 CFR 182.440. LEGACY COMPONENT DESC: Piping
Action required: 705 - Other - as specified
Due 21 May 2003
Resolved 14 May 2003
Resolution: Owner renewed bonding straps on fuel tank fills.
Engineering › Steering Gear System
Issued 21 April 2003
Resolved
Double nut or cotter pin steering tiller arms port and starboard IAW MSM Chapter 4. LEGACY COMPONENT DESC: Pin
Action required: 705 - Other - as specified
Due 21 May 2003
Resolved 14 May 2003
Resolution: Owner double nutted steering tiller arms, port and stbd.
Construction/Loadline › Hull
Issued 21 February 2002
Resolved
Repair blister as identified: Port 3 each 20ft aft of stem, 8 each 30 ft aft of stem, 7 each 40 ft aft of the stem, 1 each at 47ft aft of stem and 2 onkeel 60 ft aft of stem. Stbd side 8 each 15 ft aft of stem, 9 each 20 ft aft of stem, 1 on chine 28 ft aft of stem.
Action required: 705 - Other - as specified
Due 21 March 2002
Resolved 25 February 2002
Resolution: Owner/operator made repairs to identified blisters.
Construction/Loadline › Structures › Transverse Bulkhead
Issued 21 February 2002
Resolved
Remove bondo from aft berth compt. under ladder.
Action required: 705 - Other - as specified
Due 21 March 2002
Resolved 25 February 2002
Resolution: Owner operator removed bondo from bulkhead, it had been applied to cover paint cracking.
Engineering › Bilge Water Management System
Issued 21 February 2002
Resolved
renew bilge strainer in aft berthing compt. LEGACY COMPONENT DESC: Strainer
Condition: Unknown
Action required: 705 - Other - as specified
Due 21 March 2002
Resolved 25 February 2002
Resolution: Owner operator renewed bilge strainer in fixed system located in the aft berthing compt.
Electrical › Electrical Distribution System (service)
Issued 21 February 2002
Resolved
Remove wire nuts from aft berthing compt bilge system.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 21 March 2002
Resolved 25 February 2002
Resolution: Owner operator removed wire nuts and properly wired bilge pump.
Engineering › Shafting/Propeller Arrangements › Bearing
Issued 21 February 2002
Resolved
Renew port strut bearing and reglass shaftlog delamination.
Action required: 705 - Other - as specified
Due 21 March 2002
Resolved 25 February 2002
Resolution: Verifed satisfactory repairs.
Lifesaving
Issued 3 April 2001
Resolved
PRIOR TO THE VESSELS OPERATION ON AN OCEANS OR COASTWISE ROUTE, ENSURE THE THE CREW SHALL MEET THE REQUIREMENTS OF NAVIGATION CIRCULAR 1-91, i.e., 50%SHALL BE CPR AND FIRST AID QUALIFIED.
Condition: Unknown
Due 3 April 2001
Resolved 3 April 2001
Engineering
Issued 3 April 2001
Resolved
REPAIR STBD PROPULSION ENGINE EXHAUST SYSTEM RISER, LOCATED ON OUTBOARD BANK TO RISER CONNECTION. CURRENT ATTACHMENT IS CRACKED AND LEAKING BOTH WATER AND EXHAUST INTO MACHINERY SPACE.
Condition: Unknown
Due 3 April 2001
Resolved 3 April 2001
Lifesaving
Issued 3 April 2001
Resolved
PRIOR TO 30 APRIL 2001, RENEW THE EMERGENCY POSITION INDICATING RADIO BEACON HYDRO STATIC RELEASE, AFTER 30 APRIL THE VESSELS ROUTE WILL BE RETRICRED TO NOT MORE THAN 3 NAUTICAL MILES FROM SHORE.
Condition: Unknown
Due 5 April 2001
Resolved 5 April 2001
Construction/Loadline
Issued 3 April 2001
Resolved
REPAIR TO ORIGINAL CONFIGURATION, THE WATERTIGHT/VAPOR TIGHT BULKHEAD BETWEEN THE FUEL TANK VOID AND THE ENGINEROOM. CURRENTLY VSL HAS HOLES DRILLED BETWEEN COMPARTMENTS TO ALLOW DRAINAGE BETWEEN SUBDIVISION BULKHEADS.
Condition: Unknown
Due 3 April 2001
Resolved 3 April 2001
Construction/Loadline
Issued 3 April 2001
Resolved
CAULK PENETRATIONS OF THE FOLLOWING WATERTIGHT BULKHEADS, FWD E/R CABLE PENETRATION ON CENTERLINE ABOUT MID-HEIGHT OF BHD. ALSO LOCATED BOTH THE PORT AND STBD SIDE OF THE BHD BETWEEN E/R AND FUEL TANK VOID APPROX. MID- HEIGHT (2 DRILLED HOLES EACH SIDE).
Condition: Unknown
Due 3 April 2001
Resolved 3 April 2001
Fire Fighting
Issued 3 April 2001
Resolved
REPLACE LEAKING PVC BUSHINGS/FITTNGS WITH METALLIC FITTINGS ON THE OUTLET SIDE OF THE FIRE PUMP SEA STRAINER.
Condition: Unknown
Due 3 April 2001
Resolved 3 April 2001
Navigation
Issued 3 April 2001
Resolved
PROVIDE A COMPASS DEVIATION CARD FOR THE MAGNETIC COMPASS.
Condition: Unknown
Due 3 April 2001
Resolved 3 April 2001
Fire Fighting
Issued 3 April 2001
Resolved
PRIOR TO THE CARRIAGE OF PASSENGERS, PROVIDE DOCUMENTATION THAT THE FIXED FIRE EXTINGUISHING SYSTEM HAS BEEN PROPERLY SERVICED AS PER 46 CFR 176.810(b)(2).
Condition: Unknown
Due 4 May 2001
Resolved 6 April 2001
Fire Fighting
Issued 19 May 1998
Resolved
PROVE PROPER OPERATION OF SMOKE DETECTION SYSTEM AS PER 46 CFR 181.400.
Condition: Unknown
Due 19 May 1998
Resolved 19 May 1998
Engineering
Issued 19 May 1998
Resolved
PROVE PROPER OPERATION OF PORT RPM GUAGE AS PER 46 CFR 182.15-5.
Condition: Unknown
Due 19 May 1998
Resolved 19 May 1998
Lifesaving
Issued 19 May 1998
Resolved
PROVIDE VALID RED CROSS FIRST AID AND CPR CARDS FOR 50% OF DECKHANDS AS PERNVIC 1-91.
Condition: Unknown
Due 19 May 1998
Resolved 19 May 1998
Documentation
Issued 19 May 1998
Resolved
POST STABILITY LETTER AT OPERATING STATION AS PER 46 CFR 176.306.
Condition: Unknown
Due 19 May 1998
Resolved 19 May 1998
Electrical
Issued 19 May 1998
Resolved
REMOVE ALL UNUSED SECTIONS OF ELECTRICAL WIRING AS PER 46 CFR 183.05.
Condition: Unknown
Due 19 May 1998
Resolved 19 May 1998
Lifesaving
Issued 19 May 1998
Resolved
PROVIDE FIRST AID KIT MEETING REQUIREMENTS OF 46 CFR 160.041.
Condition: Unknown
Due 19 May 1998
Resolved 19 May 1998
Fire Fighting
Issued 19 May 1998
Resolved
PROPERLY INSTALL B-I FIRE EXTINGUISHER HOLDER AS PER 46 CFR 176.
Condition: Unknown
Due 19 May 1998
Resolved 19 May 1998
Navigation
Issued 19 May 1998
Resolved
TIGHTEN PORT RUDDER PACKING AS PER 46 CFR 176.814.
Condition: Unknown
Due 19 May 1998
Resolved 19 May 1998
Construction/Loadline
Issued 22 April 1997
Resolved
ATTACH A RETENSION LANYARD AS PER 46 CFR 179.360(a)(2) TO ALL HATCH COVERS.
Condition: Unknown
Due 22 May 1997
Resolved 8 December 1997
Navigation
Issued 22 April 1997
Resolved
REPAIR STBD RUDDER INTERIOR BARREL (RUDDER HOUSING) DUE TO FOUNDATION CRACK.
Condition: Unknown
Due 22 May 1997
Resolved 8 December 1997
Engineering
Issued 22 April 1997
Resolved
REPLACE FUEL TANK RETURN LINE FLEXIBLE HOSE, INSURE THIS HOSE MEETS SAE STANDARD J-1942 AS PER 46 CFR 182.720(E).
Condition: Unknown
Due 22 May 1997
Resolved 8 December 1997
Fire Fighting
Issued 7 May 1996
Resolved
PROVIDE ONE B-1 FIRE EXTINGUISHER WITH APPROVED BRACKET FOR PILOT HOUSE.
Condition: Unknown
Due 7 May 1996
Resolved 7 May 1996
Navigation
Issued 7 May 1996
Resolved
TIGHTEN/REPACK PORT AND STBD RUDDER STUFFING BOXES.
Condition: Unknown
Due 7 May 1996
Resolved 7 May 1996
Electrical
Issued 7 May 1996
Resolved
PROVE PROPER OPERATION OF GENERATOR INDICATOR METERS UNDER FULL LOAD.
Condition: Unknown
Due 7 May 1996
Resolved 7 May 1996
Engineering
Issued 7 May 1996
Resolved
TIGHTEN/REPACK PORT AND STBD PROPULSION SHAFT STUFFING BOX PACKING TO REDUCE LEAKAGE.
Condition: Unknown
Due 7 May 1996
Resolved 7 May 1996
Engineering
Issued 7 May 1996
Resolved
REPAIR COOLING WATER LEAK TO LOWER ELBOW ON STBD ENGINE.
Condition: Unknown
Due 7 May 1996
Resolved 7 May 1996
Navigation
Issued 7 May 1996
Resolved
REPAIR BOW LIGHT AND PROVE PROPER OPERATION IAW COLREGS 72 REQUIREMENTS FORVSL'S LESS THAT 20 METERS.
Condition: Unknown
Due 7 May 1996
Resolved 7 May 1996
Lifesaving
Issued 7 May 1996
Resolved
REPLACE RETROREFLECTIVE TAPE FOR 27 ADULT LIFE JACKETS.
Condition: Unknown
Due 7 May 1996
Resolved 7 May 1996
Documentation
Issued 7 May 1996
Resolved
PROVIDE ON BOARD VSL COPY OF NAVIGATION RULES (72 COLREGS) AND 46 CFR SUBCHAPTER "T" REGULATIONS.
Condition: Unknown
Due 7 May 1996
Resolved 7 May 1996
Engineering
Issued 7 May 1996
Resolved
REPLACE/TIGHTEN ALL HOSE CLAMPS ON EXHAUST MUFFLERS IN AFT COMPARTMENT TO STOP LEAKAGE.
Condition: Unknown
Due 7 May 1996
Resolved 7 May 1996
Lifesaving
Issued 7 March 1996
Resolved
MAKE PROPER REPAIRS IAW MANUFACTURES INSTRUCTIONS TO BOTH LIFE FLOATS, REPAINT AND RE-STENCIL.
Condition: Unknown
Due 7 March 1996
Resolved 7 March 1996
Construction/Loadline
Issued 7 March 1996
Resolved
CLEAN AND PROPERLY DISPOSE OF ALL WATER/OIL FROM ENGINE ROOM BILGE AND CLEAN ALL BILGES THROUGHOUT VESSEL.
Condition: Unknown
Due 7 March 1996
Resolved 7 March 1996
Engineering
Issued 17 May 1994
Resolved
REPAIR AND DEMONSTRATE OPERATION OF TNE PORT PROPULSION ENGINE TACHOMETER.
Condition: Unknown
Due 17 May 1994
Resolved 17 May 1994
Engineering
Issued 17 May 1994
Resolved
RENEW PORT ENGINE FUEL SUPPLY HOSE WITH APPROVED SAE STANDARD J-1942, EQUIPED WITH FACTORY INSTALLED FITTINGS AS PER 46CFR182.40.
Condition: Unknown
Due 17 May 1994
Resolved 17 May 1994
Accommodation/Occupational Safety
Issued 17 May 1994
Resolved
PROVIDE VESSELS MSD HOLDING TANK WITH A LEVEL INDICATING DEVICE AS REQUIREDBY 33 CFR 159.83. (MUST INDICATE WHEN TANK IS 3/4 FULL)
Condition: Unknown
Due 17 May 1994
Resolved 17 May 1994
Engineering
Issued 17 May 1994
Resolved
REPAIR AND DEMONSTRATE OPERATION OF THE PORT ENGINE EXHAUST HIGH TEMPERATURE ALARM.
Condition: Unknown
Due 17 May 1994
Resolved 17 May 1994
Lifesaving
Issued 17 May 1994
Resolved
PROVIDE EIGHT (8) ADDITIONAL PFD'S TO REPLACE UNSERVICABLE ONES REMOVED FORM VESSEL. THE NUMBER OF PASSENGERS IS REDUCED TO -48-, TOTAL NUMBER OF PERSONS REDUCED TO -52- ON A COASTWISE VOYAGE UNTIL PROVIDED.
Condition: Unknown
Due 17 May 1994
Resolved 17 May 1994
Engineering
Issued 17 May 1994
Resolved
FABRICATE AND INSTALL MACHINERY GUARDS FOR THE STBD ENGINE ALTERNATOR AND BILGE DRIVE PULLEYS TO PREVENT ACCIDENTAL CATCHING OF ARTICALS IN THE SYSTEMS.
Condition: Unknown
Due 17 May 1994
Resolved 17 May 1994
Engineering
Issued 17 May 1994
Resolved
PROVIDE PROPER SUPPORT BRACKETS FOR THE COOLING WATER SYSTEMS TO PREVENT SAGGING/VIBRATION CASUALTIES.
Condition: Unknown
Due 17 May 1994
Resolved 17 May 1994
Lifesaving
Issued 17 May 1994
Resolved
RENEW EPIRB BATTERY WITH A CURRENT, DATED BATTERY. CURRENT BATTERY DATED 4/94 BUT EPIRB TESTED SAISFACTORILY.
Condition: Unknown
Due 17 May 1994
Resolved 17 May 1994
Electrical
Issued 17 May 1994
Resolved
REPLACE INOPERABLE GENERATOR ALT. CURRENT AMP GUAGE FOR INDICATING PANEL LOCATED ON VSLS BRIDGE.
Condition: Unknown
Due 17 May 1994
Resolved 17 May 1994
Navigation
Issued 17 May 1994
Resolved
REPLACE BOTH PORT/STBD RUNNING LIGHTS WITH UL1104 APPROVED LIGHTS FOR VESSELS OF 20 METERS OR GREATER IN LENGTH (2 MILE RANGE) AS PER RULE 23 OF 72 COLREGS.
Condition: Unknown
Due 17 May 1994
Resolved 17 May 1994
Navigation
Issued 17 May 1994
Resolved
REPLACE ANCHOR LIGHT WITH UL 1104 APPROVED LIGHT, INSLUDING PROPER MOUNT._x001C_ CURRENT LIGHT STANDARD 12VDC 1157 AUTOMOTIVE FIXTURE.
Condition: Unknown
Due 17 May 1994
Resolved 17 May 1994
Construction/Loadline
Issued 17 May 1994
Resolved
REPAIR UPPER PASSENGER LEVEL HAND RAIL STANSION, LOCATED ON CENTERLINE AT AFT DECK AREA.
Condition: Unknown
Due 17 May 1994
Resolved 17 May 1994
Electrical
Issued 9 June 1993
Resolved
INSTALL COVERS ON ALL EELECTRICAL DISTRIBUTION AND DISCONNECTS BOXES.
Condition: Unknown
Due 9 June 1993
Resolved 9 June 1993
Engineering
Issued 9 June 1993
Resolved
INSTALL FACTORY TYPE END FITTINGS TO ALL FUEL OIL NON-METALLIC FUEL HOSES.
Condition: Unknown
Due 9 June 1993
Resolved 9 June 1993
Electrical
Issued 9 June 1993
Resolved
RENEW A/C/HEAT PUMP WIRING WITH CG ACCEPTED ELECTRICAL CABLE.
Condition: Unknown
Due 9 June 1993
Resolved 9 June 1993
Electrical
Issued 9 June 1993
Resolved
PROVE OPERATION OF GENERATOR AMMETER.
Condition: Unknown
Due 9 June 1993
Resolved 9 June 1993
Engineering
Issued 9 June 1993
Resolved
INSTALL PROTECTIVE BLANKETS ON EXHAUST PIPING FORWARD OF RAW WATER INJECTION.
Condition: Unknown
Due 9 June 1993
Resolved 9 June 1993
Electrical
Issued 9 June 1993
Resolved
PROPERLY LABEL PURPOSE OF ALL ELECTRICAL DISTRIBUTION CIRCUIT DISCONNECTS IN ENGINE ROOM.
Condition: Unknown
Due 30 June 1993
Resolved 30 June 1993
Construction/Loadline
Issued 9 June 1993
Resolved
INSTALL CHECK VALVES IN BILGE MANIFOLD PIPING SYSTEM.
Condition: Unknown
Due 9 June 1993
Resolved 9 June 1993
Electrical
Issued 9 June 1993
Resolved
PROVIDE DIRECTORY OF CIRCUITS FOR 12 VDC DISTRIBUTION PANEL.
Condition: Unknown
Due 9 June 1993
Resolved 9 June 1993
Navigation
Issued 9 June 1993
Resolved
PROVE OPERATION OF COMPASS LIGHT.
Condition: Unknown
Due 9 June 1993
Resolved 9 June 1993
Construction/Loadline
Issued 18 July 1991
Resolved
ATTACH WATERTIGHT DECK HATCHES TO HULL._x001C_
Condition: Unknown
Due 18 July 1991
Resolved 18 July 1991
Engineering
Issued 18 July 1991
Resolved
REPLACE FUEL HOSE TO INDEPENDENT GENERATOR WITH APPROVED FUEL HOSE._x001C_
Condition: Unknown
Due 18 July 1991
Resolved 18 July 1991
Lifesaving
Issued 18 July 1991
Resolved
ATTACH LINE BETWEEN LIFE FLOATS OR PROVIDE -1- MORE PAINTER LINE AND WEAK LINK._x001C_
Condition: Unknown
Due 18 July 1991
Resolved 18 July 1991
Navigation
Issued 18 July 1991
Resolved
PROVE PROPER OPERATION OF SINGLE SIDEBAND RADIO._x001C_
Condition: Unknown
Due 18 July 1991
Resolved 18 July 1991
Construction/Loadline
Issued 18 July 1991
Resolved
PROVE PROPER OPERATION OF INSTALLED BILGE SYSTEM._x001C_
Condition: Unknown
Due 18 July 1991
Resolved 18 July 1991
Unknown
Issued 6 June 1990
Resolved
PROVIDE PADDLES WITH VESSEL'S NAME MARKED FOR BOTH LIFE FLOATS.
Condition: Unknown
Due 6 June 1990
Resolved 6 June 1990
Unknown
Issued 6 June 1990
Resolved
PROVIDE ONE(1) PFD WATER LIGHT.
Condition: Unknown
Due 6 June 1990
Resolved 6 June 1990
Unknown
Issued 6 June 1990
Resolved
PROVE PROPER OPERATION OF LOWER BERTHING AREA EMERGENCY LIGHT.
Condition: Unknown
Due 6 June 1990
Resolved 6 June 1990
Unknown
Issued 6 June 1990
Resolved
MARK FIRE STATION AND PROVIDE PROPER BRACKET FOR HOSE.
Condition: Unknown
Due 6 June 1990
Resolved 6 June 1990
Unknown
Issued 6 June 1990
Resolved
PROVIDE EVIDENCE OF OPERATORS FCC MARINE OPERATORS PERMIT RENEWAL.
Condition: Unknown
Due 6 June 1990
Resolved 6 June 1990
Unknown
Issued 6 June 1990
Resolved
PROVE PROPER OPERATION OF OR REPLACE VESSELS E.P.I.R.B.
Condition: Unknown
Due 6 June 1990
Resolved 6 June 1990
Unknown
Issued 14 June 1988
Resolved
PROVE PROPER OPERATION OF BELOW DECK AUTOMATIC EMERGENCY LIGHTS.
Condition: Unknown
Due 14 June 1988
Resolved 14 June 1988
Unknown
Issued 14 June 1988
Resolved
PROPERLY INSTALL WIRING ON STBD BATTERY.
Condition: Unknown
Due 14 June 1988
Resolved 14 June 1988
Unknown
Issued 14 June 1988
Resolved
POST ALL CERTIFICATES UNDER GLASS.
Condition: Unknown
Due 14 June 1988
Resolved 14 June 1988
Unknown
Issued 14 June 1988
Resolved
PROPERLY SPLICE ALL 12V ELECTRIC BILGE PUMP WIRING.
Condition: Unknown
Due 14 June 1988
Resolved 14 June 1988
Unknown
Issued 14 June 1988
Resolved
PROVE PROPER OPERATION OF ENTIRE FIXED BILGE PUMP SYSTEM.
Condition: Unknown
Due 14 June 1988
Resolved 14 June 1988
Unknown
Issued 14 June 1988
Resolved
PROVIDE VALID FCC SAFETY RADIO TELEPHONY CERTIFICATE.
Condition: Unknown
Due 14 June 1988
Resolved 14 June 1988
Accommodation/Occupational Safety
Issued 22 June 1987
Resolved
REROUTE MSD HOLDING TANK VENT TO AS NEAR MAIN DECK LEVEL AS POSSIBLE AND CAP OR REMOVE EXISTING THROUGH HULL FITTING
Condition: Unknown
Due 22 June 1987
Resolved 22 June 1987
Electrical
Issued 22 June 1987
Resolved
INSTALL FREQUENCY METER FOR AC GENERATOR
Condition: Unknown
Due 22 June 1987
Resolved 22 June 1987