Records from 1987 to 2025. Most recent: inspection, 26 September 2025.
Inspection history · 151
26 September 2025
Deficiency Check
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 8242089
22 June 2024
Examination of Repairs
Physical examination · Detached Duty Office Seward · USCG Arctic District (CGD-A) · Activity 7951181
21 June 2024
Type not recorded
No type recorded · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 7973084
19 June 2024
Administrative Inspection
Administrative · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 7962360
19 June 2024
Type not recorded
No type recorded · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 7973058
9 May 2024
Deficiency Check · Administrative Inspection
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 7909699
23 April 2024
Annual Inspection
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 7889530
17 August 2023
Administrative Inspection · In-Service Inspection
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 7776045
31 July 2023
Administrative Inspection · Deficiency Check · Damage Survey
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 7757269
25 May 2023
Deficiency Check · Administrative Inspection · Damage Survey
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 7701815
25 May 2023
Type not recorded
No type recorded · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 7942518
1 May 2023
Annual Inspection · Deficiency Check · Administrative Inspection
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 7679487
22 September 2022
Hull Examination · Internal Structural Exam · Administrative Inspection · Drydock Exam
Physical examination · Detached Duty Office Seward · USCG Arctic District (CGD-A) · Activity 7548282
18 August 2022
In-Service Inspection
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 7538319
29 June 2022
Deficiency Check · Damage Survey
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 7490709
12 April 2022
COI Inspection · Administrative Inspection
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 7429856
27 May 2021
Annual Inspection · Deficiency Check · Administrative Inspection
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 7206924
30 March 2021
Examination of Repairs · Drydock Exam · Administrative Inspection · Internal Structural Exam
Physical examination · Detached Duty Office Seward · USCG Arctic District (CGD-A) · Activity 7188671
4 March 2020
Administrative Inspection
Administrative · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 6920644
25 September 2019
Administrative Inspection · Examination of Repairs · Internal Structural Exam · Drydock Exam
Physical examination · Detached Duty Office Seward · USCG Arctic District (CGD-A) · Activity 6821788
24 April 2019
DAPI Audit · Deficiency Check · Administrative Inspection · Annual Inspection
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 6673854
12 March 2019
Deficiency Check · Examination of Repairs
Physical examination · Detached Duty Office Seward · USCG Arctic District (CGD-A) · Activity 6641470
12 September 2018
Damage Survey
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 6538928
11 September 2018
Type not recorded
No type recorded · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 6540732
18 June 2018
Type not recorded
No type recorded · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 6456103
18 April 2018
Annual Inspection
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 6395179
21 September 2017
Deficiency Check · Internal Structural Exam · Administrative Inspection · Drydock Exam
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 6281483
4 July 2017
Administrative Inspection
Administrative · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 6223701
31 March 2017
COI Inspection · Administrative Inspection · Deficiency Check
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 6115463
7 June 2016
Administrative Inspection · Examination of Repairs
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 5930993
2 May 2016
Deficiency Check · Annual Inspection
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 5874869
13 October 2015
Hull Examination · Internal Structural Exam · Deficiency Check
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 5742884
3 September 2015
Administrative Inspection
Administrative · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 5234201
24 June 2014
Administrative Inspection · Examination of Repairs
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 4898529
23 June 2014
Type not recorded
No type recorded · USCG Arctic District (dp) · USCG Arctic District (CGD-A) · Activity 4898465
10 May 2012
Internal Structural Exam · Initial Certification · Deficiency Check
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 4304917
1 December 2011
Plan Review "T" Boat · Deadweight Survey · Construction Oversight · COI Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4295369
26 July 2011
Hull Examination
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 4095289
6 March 2007
Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2882867
4 May 2006
COI Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2604354
13 April 2006
Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2622607
7 April 2006
Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2619756
8 October 2005
Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2509938
6 October 2005
Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2509461
9 October 2004
Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 2217247
18 September 2004
Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 2198872
13 September 2004
Annual Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 2182074
12 March 2004
Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 2023413
16 December 2003
Internal Structural Exam
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1964949
30 October 2003
Drydock Extension
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1925066
18 April 2003
COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1775769
27 August 2002
Damage Survey
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1667925
27 August 2002
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1670394
26 August 2002
Administrative Inspection
Administrative · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1666719
12 June 2002
Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1629862
22 April 2002
Annual Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1601579
31 October 2001
Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1391710
18 October 2001
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1481192
28 September 2001
Deficiency Check · Damage Survey · Hull Examination
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1445879
21 September 2001
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 147244
29 August 2001
Examination of Repairs
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1444596
28 July 2001
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 85593
26 July 2001
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 141602
23 July 2001
Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1071016
20 July 2001
Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1069800
9 July 2001
Damage Survey
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1384817
7 July 2001
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 57312
15 June 2001
COI Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1417346
20 April 2001
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1362255
7 June 2000
Administrative
Administrative · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1395462
31 May 2000
Hull Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1433656
10 September 1999
Administrative
Administrative · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 783537
3 December 1998
Type not recorded
No type recorded · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 664039
30 September 1998
Damage Survey
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 802641
16 May 1998
Type not recorded
No type recorded · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 125780
15 May 1998
COI Inspection
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1126280
12 May 1998
Examination of Repairs
Physical examination · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 790433
14 April 1998
Hull Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1434768
8 April 1998
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1126941
23 September 1997
Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1431852
2 August 1997
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 41718
2 August 1997
Damage Survey
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1422892
1 August 1997
Damage Survey
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1407935
31 July 1997
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 42625
16 June 1997
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 178572
15 June 1997
Damage Survey · Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1434578
2 June 1997
Re-Inspection · Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1111983
17 May 1997
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 92550
27 January 1997
Administrative
Administrative · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1100760
6 December 1996
Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1445138
2 November 1996
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 30383
2 November 1996
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 218839
1 November 1996
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1405991
25 October 1996
Examination of Repairs
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1396611
3 October 1996
Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1435815
28 September 1996
Damage Survey
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1418028
27 September 1996
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 115532
18 September 1996
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 28738
18 September 1996
Examination of Repairs
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 831218
18 September 1996
Damage Survey
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1371540
9 September 1996
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 53732
15 July 1996
Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1087824
5 June 1996
COI Inspection · Hull Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1363634
8 February 1996
Administrative
Administrative · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 875279
9 September 1995
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 74062
7 July 1995
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 108778
27 June 1995
Examination of Repairs · Damage Survey
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1190848
24 June 1995
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 212064
24 June 1995
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1191734
23 June 1995
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 212580
26 May 1995
Examination of Repairs
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1464591
24 May 1995
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 157374
23 May 1995
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 47924
20 May 1995
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 228770
15 May 1995
Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1374285
14 May 1995
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 221010
6 April 1995
COI Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1356980
16 November 1994
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1176383
13 October 1994
Administrative
Administrative · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1176178
18 September 1994
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 24539
6 September 1994
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 49217
14 August 1994
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 187947
27 July 1994
Plan Review "T" Boat · Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 869901
5 July 1994
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 10689
27 June 1994
Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1030003
2 June 1994
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1014555
28 May 1994
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 77741
7 May 1994
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 184841
22 April 1994
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1167831
13 January 1994
COI Inspection · Hull Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1409063
9 June 1993
Administrative
Administrative · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1379830
14 April 1993
COI Inspection · Drydock Extension
Physical examination · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 1358092
16 September 1992
Type not recorded
No type recorded · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 44888
16 June 1992
Type not recorded
No type recorded · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 23025
20 May 1992
COI Inspection
Physical examination · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 949969
7 May 1992
COI Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1264296
1 May 1992
Hull Examination · Plan Review "T" Boat
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 953247
10 December 1991
Deficiency Check
Physical examination · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 1261612
3 December 1991
Administrative
Administrative · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 942161
8 November 1991
Deficiency Check
Physical examination · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 940161
20 September 1991
Deficiency Check
Physical examination · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 1247661
26 May 1991
Deficiency Check · Examination of Repairs
Physical examination · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 1234324
4 April 1991
Hull Examination
Physical examination · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 912746
21 March 1991
COI Inspection
Physical examination · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 1242637
15 March 1991
Type not recorded
No type recorded · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 1227700
26 April 1990
COI Inspection
Physical examination · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 910960
28 November 1989
Type not recorded
No type recorded · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 1238205
25 May 1989
Hull Examination
Physical examination · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 1042996
11 May 1989
COI Inspection
Physical examination · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 1208657
19 May 1988
COI Inspection
Physical examination · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 1200708
30 May 1987
Initial Certification
Physical examination · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 1324422
01 - Certificates & Documentation › 011 - Ships Certificates › USCG Certificate of Documentation (COD)
Issued 23 April 2024
Resolved
Any vessel of at least five net tons which engages in the fisheries on the navigable waters of the United States or in the Exclusive Economic Zone, or coastwise trade, unless exempt under § 67.9(c), must have a Certificate of Documentation bearing a valid endorsement appropriate for the activity in which engaged. Vessel's COD is expired. Provide proof of current COD.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 June 2024
Resolved 26 September 2025
Resolution: COD renewed.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 23 April 2024
Resolved
An adult life jacket must be provided for each person carried on board a vessel. Vessel had thirty two (32) lifejackets that were not fit for service. Replace non-compliant lifejackets with approved lifejackets fit for service. Vessel's max passenger count reduced to 118 passengers.
Action required: 705 - Other - as specified
Resolved 15 May 2024
Resolution: Received email with pictures of new lifejackets.
09 - Working and Living Conditions › 092 - Working Conditions › Guards - fencing around dangerous machinery parts
Issued 23 April 2024
Resolved
An exposed hazard, such as gears or rotating machinery, must be properly protected by a cover, guard, or rail. There was no guard on the STBD MDE's flywheel and the guard on the PORT MDE's flywheel was held in place with a plastic wire tie. Install guard on STBD MDE Flywheel and attach guard on PORT MDE with metallic means.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 9 May 2024
Resolution: Recieved email with picutres of new guards.
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 1 May 2023
Resolved
Shutoff valves shall be installed to stop the flow of fuel. The port side fuel shut off handle does not stop perpendicular to piping and may not be capable of stopping the flow.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 31 May 2023
Resolved 22 May 2023
Resolution: all sat
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 1 May 2023
Resolved
Each hatch used as a means of escape must be capable of being opened by one person from either side. Hatch for the port side engine room is blocked by debris and cannot be opened from the engine room.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 31 May 2023
Resolved 22 May 2023
Resolution: all sat
09 - Working and Living Conditions › 091 - Living Conditions › Electrical devices
Issued 1 May 2023
Resolved
Cables and wires must be installed on metal supports not more that 24 inches in such a manner to avoid chafing and other damage. Wiring in the #2 port side hold is supported with zip ties.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 31 May 2023
Resolved 22 May 2023
Resolution: all sat
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 1 May 2023
Resolved
Vessel must have a stern light visible up to 2 miles. Stern light was not capable of turning on during inspection. Vessel is limited to daytime operations only.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 31 May 2023
Resolved 22 May 2023
Resolution: all sat
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 29 June 2022
Resolved
prove proper operation of port main engine pior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Due 29 June 2022
Resolved 1 July 2022
Resolution: all sat
01 - Certificates & Documentation › 011 - Ships Certificates › Cargo Ship Safety Radio (including exemption)
Issued 20 April 2022
Resolved
Vsl must have valid FCC bridge to bridge certifiacte. Certificate expired.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 May 2022
Resolved 9 May 2022
Resolution: Rcvd new Bridge to bridge cert.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 20 April 2022
Resolved
VSl must carry an approved First Aid kit or equivilant. Vsls first aid kit has expired meds.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 May 2022
Resolved 23 April 2022
Resolution: Bought new First aid kits
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 20 April 2022
Resolved
Each survival craft must be secured in a float free arrangement. 2 of the 4 HRUs were expired.
Action required: 701 - Prior to carriage of passengers/cargo
Due 29 June 2022
Resolved 23 April 2022
Resolution: New HRU's arrived and installed.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 27 May 2021
Resolved
Electrical equipment on a vessel must be installed and maintained to protect passengers, crew, other persons, and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment and elecctrical shock. 2 blanks at wheelhouse breaker box and 1 blank at starboard aft main deck breaker box missing.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 June 2021
Resolved 3 June 2021
Resolution: Rcvd email w/ pics indicating installation of blanks.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 17 June 2020
Resolved
Vessel rep stated that the vessel will be on drydock indefinately. Vessel must complete satisfactory drydock and internal structural exam prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 13 May 2021
Resolution: Completed satisfactory drydock
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 24 April 2019
Resolved
Provide operable waterlight attached to lifebuoy. Current waterlight is extinguished.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 May 2019
Resolved 3 May 2019
Resolution: Observed operable waterlight properly attached to ringe life buoy.
11 - Life Saving Appliances › N/A - No Subsystem › Stowage and provision of liferafts
Issued 24 April 2019
Resolved
Provide 03 hydrostatic release units for proper liferaft arrangement. 03 out of 04 hydrostatic release units attached to liferafts are expired as of April 2019.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 May 2019
Resolved 3 May 2019
Resolution: Observed proper installation of 03 hydrostatic release units attached to liferafts.
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 24 April 2019
Resolved
Provide liferaft servicing certificates onboard with vessel documentation. Liferafts are properly labeled and within inspection/servicing timeframe, but documentation is missing.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 May 2019
Resolved 24 April 2019
Resolution: Observed liferaft servicing certificates onboard the vessel.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 24 April 2019
Resolved
Provide documentation of company enrollment in drug testing program onboard vessel. Documentation shall show individual employees enrollment in pre-employment and random drug testing. Documentation not onboard.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 May 2019
Resolved 24 April 2019
Resolution: Observed documentation of enrollment in drug testing program. Crew enrolled in pre-employment and random drug testing.
Lifesaving › Hand Flares › Not on Board
Issued 18 April 2018
Resolved
Provide 6 total red hand flares prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Due 21 May 2018
Resolved 12 March 2019
Resolution: Cleared per attending annual inspector.
Lifesaving › Lifejacket/PFD (General) › Quantity
Issued 18 April 2018
Resolved
Provide one additional lifejacket to meet minimum requirement per COI. Vessel restricted to 154 passengers until deficiency is cleared.
Action required: 705 - Other - as specified
Due 21 May 2018
Resolved 12 March 2019
Resolution: Cleared per attending annual inspector.
Operations/Management › Drills/Instruction › Not Conducted
Issued 18 April 2018
Resolved
Conduct satisfactory drills in the presence of an attending CG Marine Inspector.
Action required: 705 - Other - as specified
Due 21 May 2018
Resolved 12 March 2019
Resolution: Cleared per attending annual inspector.
Construction/Loadline › Structures › Deck Plating
Issued 18 April 2018
Resolved
Repair crack in stbd engineroom ceiling underneath restroom. Remove dd insert, crop and renew insert extending beyond existing repair. Conduct repairs prior to next operating season.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 18 April 2019
Resolved 10 April 2019
Resolution: Sat repair
Personnel › Training › Familiarization Training
Issued 20 April 2017
Resolved
Provide regular vessel crew to conduct fire, abandon ship and man overboard drills.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 2 May 2017
Navigation › Piloting/Steering › Marine Charts
Issued 2 May 2016
Resolved
Provide current Light List, Coast Pilot, Tides, Tidal Currents, & navigation charts (46CFR185.20-35).
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 13 May 2016
Resolved 6 May 2016
Resolution: Observed new nav pubs @ wheelhouse.
Communications › Audible Communications › Bell
Issued 2 May 2016
Resolved
Install 300 mm (11.8") bell (NAVRULE 35/Annex III).
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 13 May 2016
Resolved 6 May 2016
Resolution: Observed newly installed bell.
Lifesaving › Lifejacket/PFD (Type I) › Retroreflective Material
Issued 2 May 2016
Resolved
Add vessel name &/or replace retro to 10 adult & 2 child lifejackets (46CFR180.25-25).
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 13 May 2016
Resolved 2 May 2016
Resolution: Observed properly marked/retro'd lifejackets.
Electrical › Electrical Distribution System (service) › Panelboard
Issued 2 May 2016
Resolved
Install 3 blanks to stbd E/R distribution panel (46CFR183.10-10).
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 13 May 2016
Resolved 2 May 2016
Resolution: Observed newly installed blanks.
Communications › Alarms/Indicators › Bilge Alarm
Issued 2 May 2016
Resolved
Prove proper operation of port forepeak bilge high level alarm.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 13 May 2016
Resolved 2 May 2016
Resolution: Witnessed sat audible/visual alarm.
Electrical › Electric Supply System (service) › Battery Installation
Issued 2 May 2016
Resolved
Install corrosion resistant tray/box for batteries btwn E/Rs.
Condition: Invalid
Action required: 705 - Other - as specified
Due 13 May 2016
Resolved 6 May 2016
Resolution: Deleted this requirement. AGM battery maintenance free.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 2 May 2016
Resolved
Raise anchor light so that it can be seen all around (NAVRULE 30).
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 2 June 2016
Resolved 31 May 2016
Resolution: Administratively cleared following receipt of email w/ photo of repositioned anchor light.
Engineering › Shafting/Propeller Arrangements › Strut Bearing
Issued 13 October 2015
Resolved
Replace both port and STBD strut bearing.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 13 November 2015
Resolved 28 October 2015
Resolution: Bearings replaced with new.
Engineering › Steering Gear System › Rudder
Issued 13 October 2015
Resolved
Make proper repair crack on weld center of STBD rudder
Condition: Damaged By Earlier Event
Due 13 November 2015
Resolved 22 October 2015
Resolution: The crack was gouge out and a proper weld was installed.
Construction/Loadline › Hull › Stiffener
Issued 13 October 2015
Resolved
Make proper repair to STBD stern platform
Condition: Damaged By Earlier Event
Due 13 November 2015
Resolved 28 October 2015
Resolution: Replacement of metal and welding repair appeared satisfactory.
Construction/Loadline › Structures › Transverse Bulkhead
Issued 13 October 2015
Resolved
Make proper repair to crack centerline frame #1
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 13 November 2015
Resolved 22 October 2015
Resolution: Crack has been gouge out and a proper weld was installed.
Construction/Loadline › Hull › Side Shell
Issued 13 October 2015
Resolved
Make proper repair to port hull between frame 3-4
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 13 November 2015
Resolved 28 October 2015
Resolution: Insert appeared satisfactory.
Engineering › Sea-water System (primary cooling) › Valve
Issued 13 October 2015
Resolved
Replace port MDE inboard sea chest valve
Condition: Improper/Lack of Maintenance
Due 13 November 2015
Resolved 22 October 2015
Resolution: Replaced port MDE inboard sea chest valve with new in-kind valve.
Engineering › Sea-water System (primary cooling) › Valve
Issued 13 October 2015
Resolved
Replace STBD MDE outboard sea chest valve.
Condition: Improper/Lack of Maintenance
Due 13 November 2015
Resolved 22 October 2015
Resolution: Replaced STBD MDE inboard sea chest valve with new in-kind valve.
Engineering › Bilge Water Management System › Hose
Issued 13 October 2015
Resolved
Properly install port and STBD electric bilge pump discharge line, install overboard valve in port aft compartment.
Condition: Improper Installation
Due 13 November 2015
Resolved 22 October 2015
Resolution: New overboard discharge valve was installed on the inboard side of the port hull.
Pollution Prevention/Response › Prevention Equipment › Sewage System Piping
Issued 13 October 2015
Resolved
Submit drawings to this office to install sea chest in port aft compartment.
Condition: Improper Installation
Due 13 November 2015
Resolved 22 October 2015
Resolution: Drawings were submitted and approved to install sea chest in port aft compartment. All welds and dye pin test to both sides of the hull were inspected and witnessed by cg inspector.
Engineering › Diesel Engine (propulsion-reduction gear) › Valve Actuating Gear
Issued 24 June 2014
Resolved
Satisfactorily repair or replace shifting actuator mechanism on port main engine. Provide technician's report, conduct sea trials, and send emailed report of results to attending marine inspectors.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 24 June 2014
Resolved 25 June 2014
Resolution: Confirmed satisfactory operation of port main engine following tech repair. Tech report to follow, attached to this case.
Documentation › Certificates/Documents › Stability Letter
Issued 10 May 2012
Resolved
Total persons is reduced to 132, of which 127 may be passengers, utilizing the weight ratio method to comply with the Final Rule on passenger weight standards, effective Dec, 1, 2011. Upper deck capacity is reduced to 20 passengers. This shall remain in effect until new Stability Letter Issued by MSC.
Action required: 705 - Other - as specified
Resolved 29 June 2012
Resolution: MSC issued new stability letter permitting 149 passengers and 4 crew.
Fire Fighting › Fixed Fire Detection System › Arrangement
Issued 10 May 2012
Resolved
Provide fire detection for machinery space & generator space. Must be installed IAW approved plans & 46 CFR 76.27. Machinery space & generator space must be visually inspected every hour when underway w/ passengers.
Action required: 705 - Other - as specified
Due 11 June 2012
Resolved 19 June 2012
Resolution: Operator installed approved fire detection system in machinery and generator space. Witnessed satisfactory test of system.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Controls
Issued 10 May 2012
Resolved
Provide access to time delay bypass valve in CO2 storage.
Action required: 705 - Other - as specified
Due 17 May 2012
Resolved 16 May 2012
Resolution: Examined new access & cleared.
Fire Fighting › Portable CO2 Fire Extinguisher › Number
Issued 10 May 2012
Resolved
Install CO2 B-II or C-II portable fire ext. w/ proper bracket outside of P/S generator space and P/S machinery space.
Action required: 705 - Other - as specified
Due 17 May 2012
Resolved 17 May 2012
Resolution: Operator installed appropriate extinguishers, verified via photo.
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 10 May 2012
Resolved
Make accurate all lifejacket stowage markings.
Action required: 705 - Other - as specified
Due 17 May 2012
Resolved 17 May 2012
Resolution: Operator stenciled proper stowage markings, verified via photo.
Documentation › Markings/Placards › Lifejacket Placard
Issued 10 May 2012
Resolved
Provide lifejacket donning placards on main deck & upper deck.
Action required: 705 - Other - as specified
Due 17 May 2012
Resolved 17 May 2012
Resolution: Operator provided required placards. Verified via photo.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 10 May 2012
Resolved
Provide rail course of 4" or equivalent on upper most deck.
Action required: 705 - Other - as specified
Due 11 June 2012
Resolved 19 June 2012
Resolution: Operator installed proper rail courses on upper deck.
Documentation › Markings/Placards › Warning Signs
Issued 10 May 2012
Resolved
Provide signs designating aft main deck "crew only".
Action required: 705 - Other - as specified
Due 17 May 2012
Resolved 16 May 2012
Resolution: Examined/cleared.
Documentation › Markings/Placards › Capacity Marking
Issued 10 May 2012
Resolved
Provide marking indicating pax limit on upper most deck IAW stability letter.
Action required: 705 - Other - as specified
Resolved 17 May 2012
Resolution: Operator labeled current max capacity based on weight reduction & old stability letter, will update new capacity when final stability letter arrives.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 10 May 2012
Resolved
Provide guards for rotating flywheels on both main engines.
Action required: 705 - Other - as specified
Due 11 June 2012
Resolved 19 June 2012
Resolution: Operator provided guards for rotating flywheels on both main engines.
Accommodation/Occupational Safety › Occupational Safety › Portable Electric Equipment/Appliances
Issued 10 May 2012
Resolved
Remove portable power strip permanently wired in fidley space.
Action required: 705 - Other - as specified
Due 17 May 2012
Resolved 16 May 2012
Resolution: Examined/cleared.
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 10 May 2012
Resolved
Secure tool chest in fidley space from movement.
Action required: 705 - Other - as specified
Due 17 May 2012
Resolved 16 May 2012
Resolution: Examined/cleared.
Electrical › Electric Supply System (service) › Battery Installation
Issued 10 May 2012
Resolved
Provide cover for aft battery box in STBD engine space.
Action required: 705 - Other - as specified
Due 17 May 2012
Resolved 16 May 2012
Resolution: Examined/cleared.
Engineering › Bilge Water Management System › Valve
Issued 10 May 2012
Resolved
Replace STBD collision bulkhead ball valve w/ screw down type valve & make void #2 readily accessible.
Action required: 705 - Other - as specified
Due 31 May 2012
Resolved 19 June 2012
Resolution: Operator installed screw down type valve at stbd collision bulkhead.
Documentation › Safety/Response Plans/Programs › Waste Management Plan
Issued 10 May 2012
Resolved
Provide waste management plan.
Action required: 705 - Other - as specified
Due 17 May 2012
Resolved 17 May 2012
Resolution: Operator provided waste management plan, verified via photo.
Documentation › Certificates/Documents › Stability Letter
Issued 18 April 2012
Resolved
Provide proof of updated stability letter IAW 46 CFR 176.306.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 May 2012
Resolution: Issued new requirement for reduction in passengers using weight ratio based on previous stability letter, to remain in effect until new stability letter issued by MSC.
Operations/Management › Drills/Instruction › Not Conducted
Issued 18 April 2012
Resolved
Conduct required fire, man overboard, and abandonship drills IAW 46 CFR 185.520.
Action required: 701 - Prior to carriage of passengers/cargo
Due 10 May 2012
Resolved 2 May 2016
Resolution: Witnessed sat drills.
Documentation › Logs/Records › Logbook/Record (unofficial)
Issued 18 April 2012
Resolved
Provide all training logs and records onboard IAW 46 CFR 185420 & 185.524.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 May 2012
Resolution: Operator provided training records and log aboard vessel.
Construction/Loadline › Hull › Longitudinal Frame
Issued 12 April 2012
Resolved
Vee and reweld 6 weldments in forepeak from longitudinals to 1st and 2nd transverse frames.
Due 18 April 2012
Resolved 18 April 2012
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 12 April 2012
Resolved
Attach chain rail at stem by ladders to swimsteps.
Due 18 April 2012
Resolved 18 April 2012
Lifesaving › Buoyant Smoke Signals › General
Issued 12 April 2012
Resolved
Missing one orange smoke signal from signaling device.
Due 18 April 2012
Resolved 18 April 2012
Engineering › Bilge Water Management System › Pump
Issued 12 April 2012
Resolved
Repair bilge suction staboard pump that is inoperable.
Due 18 April 2012
Resolved 18 April 2012
Stability › Intact Stability (when using lifting gear) › General
Issued 12 April 2012
Resolved
Properly label max passengers on upper deck IAW 46 CFR 185.602(g).
Action required: 705 - Other - as specified
Resolved 10 May 2012
Resolution: Issued new requirement for marking of max capacity.
Communications › Internal Communications System › Voice Tube
Issued 4 May 2006
Resolved
Public address system was not working. Provide functioning PA system to the satisfaction of an attending Marine Inspector NLT 04JUN06.
Condition: Unknown
Action required: 705 - Other - as specified
Due 4 June 2006
Resolved 15 June 2006
Documentation › Logs/Records › Drug Test Records
Issued 4 May 2006
Resolved
Drug and Alcohol Program paperwork was not present onboard. Provide Compliance documentation of participation in a certified and current Drug and Alcohol testing program NLT 18MAY06.
Condition: Unknown
Action required: 705 - Other - as specified
Due 18 May 2006
Resolved 5 May 2006
Resolution: Paperwork was faxed to Sector officer. Paperwork was reviewed and to the satisfaction of the Coast Guard Inspector.
Fire Fighting › Portable CO2 Fire Extinguisher › Service
Issued 8 October 2005
Resolved
Provide annual servicing to all portable fire extinguishers.
Action required: 701 - Prior to carriage of passengers/cargo
Due 15 October 2005
Resolved 12 October 2005
Resolution: Provided servicing.
Lifesaving › Inflatable Liferafts › Painter
Issued 8 October 2005
Resolved
Properly attach sea painter to weak link on vessel for both inflatable liferafts.
Action required: 701 - Prior to carriage of passengers/cargo
Due 15 October 2005
Resolved 12 October 2005
Resolution: Cleared.
Lifesaving › Lifefloat › Float-free Link
Issued 8 October 2005
Resolved
Attach weak link to vessel.
Action required: 705 - Other - as specified
Due 8 October 2005
Resolved 8 October 2005
Resolution: Corrected during exam.
Operations/Management › Equipment Service/Testing › EPIRB
Issued 8 October 2005
Resolved
Replace expired hydrostatic release.
Action required: 701 - Prior to carriage of passengers/cargo
Due 15 October 2005
Resolved 12 October 2005
Resolution: Cleared.
Documentation › Certificates/Documents › Stability Letter
Issued 8 October 2005
Resolved
Attain copy of vessel's stability letter and properly display under glass with all pages visible.
Action required: 705 - Other - as specified
Due 15 October 2005
Resolved 12 October 2005
Resolution: Inspector provided copy and witnessed it being posted.
Lifesaving › Visual Distress Signals (General) › Storage
Issued 8 October 2005
Resolved
Properly stow visual distress signals.
Action required: 705 - Other - as specified
Due 15 October 2005
Resolved 12 October 2005
Resolution: Cleared.
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type III
Issued 8 October 2005
Resolved
Lock overboard discharge valve.
Action required: 705 - Other - as specified
Due 15 October 2005
Resolved 12 October 2005
Resolution: Locked.
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 8 October 2005
Resolved
Conduct man overboard drill under supervision of marine inspector.
Action required: 705 - Other - as specified
Due 15 October 2005
Resolved 12 October 2005
Resolution: Conducted drill with satisfactory results.
Operations/Management › Drills/Instruction › Fire
Issued 8 October 2005
Resolved
Conduct fire drill under supervision of marine inspector.
Action required: 705 - Other - as specified
Due 15 October 2005
Resolved 12 October 2005
Resolution: Conducted drill with satisfactory results.
Personnel › Manning/Qualifications › Minimum Safe Manning
Issued 8 October 2005
Resolved
Conduct drills with the manning level required on COI.
Action required: 705 - Other - as specified
Due 15 October 2005
Resolved 12 October 2005
Resolution: Conducted drills with required manning.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 6 October 2005
Resolved
Complete satisfactory annual exam IAW 46CFR176.500(b) Annual exam to be completed prior to carrying passengers and by 06NOV2005.
Action required: 701 - Prior to carriage of passengers/cargo
Due 7 November 2005
Resolved 12 October 2005
Resolution: Completed satisfactory annual exam.
Lifesaving › Buoyant Apparatus › Floating Electric Waterlight
Issued 13 September 2004
Resolved
Provide 2 paddles and a waterlight for 15 person buoyant apparatus I.A.W. 46 CFR 180.175(e) and 46 CFR 180.175(f)(1) & (4).
Action required: 705 - Other - as specified
Due 27 September 2004
Resolved 8 October 2004
Resolution: Two paddles and a waterlight provided.
Electrical › Electric Supply System (service) › Battery Installation
Issued 13 September 2004
Resolved
Secure and cover batteries located in starboard side engine room I.A.W. 46 CFR 183.350(b).
Action required: 705 - Other - as specified
Due 27 September 2004
Resolved 8 October 2004
Resolution: Batteries covered and secured.
Electrical › Electrical Distribution System (service) › Switchboard
Issued 13 September 2004
Resolved
Bland off empty spaces in port side laz and galley fuse boxes I.A.W. 46 CFR 183.330(b).
Action required: 705 - Other - as specified
Due 27 September 2004
Resolved 8 October 2004
Resolution: Empty spaces in fuse boxes blanked off.
Engineering › Diesel Engine (propulsion-direct drive) › Piping (exhaust)
Issued 13 September 2004
Resolved
Provide lagging on port and starboard engine exhaust pipes.
Action required: 705 - Other - as specified
Due 27 September 2004
Resolved 8 October 2004
Resolution: Lagging on port and starboard engine exhaust pipes provided.
Engineering › Fuel Oil Service System › Valve
Issued 13 September 2004
Resolved
Mark fuel shutoff valves I.A.W. 46 CFR 185.608.
Action required: 705 - Other - as specified
Due 27 September 2004
Resolved 8 October 2004
Resolution: Fuel shutoff valves marked.
Documentation › Certificates/Documents › FCC SSL
Issued 13 September 2004
Resolved
Provide current FCC Station License and Safety Radio Telephony Certificate with correct vessel name, official number, and radio call sign.
Action required: 705 - Other - as specified
Due 27 September 2004
Resolved 8 October 2005
Engineering › Fuel Oil Storage/Transfer System
Issued 18 December 2003
Resolved
Regarding fuel storage tank in center void: Empty and gas-free "safe for hot work", then remove both ends of the tank to prevent its future use and to facilitate natural ventilation in the tank. Obtain "safe for workers" certificate for compartment, to clear this requirement. LEGACY COMPONENT DESC: Tank
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 18 January 2004
Resolved 17 March 2004
Resolution: Observed gas-free certification, hole cut in fwd end of tank, and all associated piping removed.
Engineering › Fuel Oil Service System
Issued 16 December 2003
Resolved
In both enginerooms, repair or replace both emergency fuel tank shut-off valve cable assemblies. The existing assemblies have rusted and inoperable cable pulleys, improper cable size, improper size wire rope clips, splices and kinks. Port engineroom assembly must not be in way of emergency escape. LEGACY COMPONENT DESC: Valve, Control
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 25 December 2003
Resolved 17 March 2004
Resolution: New cabling installed. Conducted satisfactory test.
Electrical › Electric Supply System (service)
Issued 16 December 2003
Resolved
In both enginerooms, repair or replace both battery shelves. Existing shelves are in disrepair with fractured welds, leaning, and propped up with 2 x 4" lumber. LEGACY COMPONENT DESC: Battery Installation
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Due 25 December 2003
Resolved 17 March 2004
Resolution: Shelves repaired.
Engineering › Fuel Oil Storage/Transfer System
Issued 16 December 2003
Resolved
In stbd engineroom, install missing brackets for fuel piping on center of outboard bulkhead. This requirement can be alleviated by removing the piping all together, which may happen as the fuel tank supplying the pipes, may be removed. LEGACY COMPONENT DESC: Piping
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 25 December 2003
Resolved 17 March 2004
Resolution: Brackets installed.
Engineering › Fuel Oil Service System
Issued 16 December 2003
Resolved
On STBD generator fuel supply pipe, install a pipe cap on the dead end tee, just after the ball valve. LEGACY COMPONENT DESC: Piping
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 25 December 2003
Resolved 17 March 2004
Resolution: Pipe cap installed.
Electrical › Lighting (service)
Issued 16 December 2003
Resolved
Above STBD main engine, repair interior wiring connections to light ballast with proper connectors and IAW 46 CFR 183.340. LEGACY COMPONENT DESC: Lighting Fixture
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 25 December 2003
Resolved 17 March 2004
Resolution: Corrected.
Documentation › Certificates/Documents
Issued 16 December 2003
Resolved
Provide valid Certificate of Documentation and NOAA EPIRB registration, reflecting name change to "Catalina Explorer" LEGACY COMPONENT DESC: Certificate of Documentation (CG-1270)
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Due 25 December 2003
Resolved 22 March 2004
Resolution: Verified registration (name change) with NOAA.
Documentation › Certificates/Documents
Issued 9 October 2003
Resolved
Complete Internal Structural Examination as per 46 CFR 176.600. LEGACY COMPONENT DESC: Certificate of Inspection
Action required: 701 - Prior to carriage of passengers/cargo
Due 9 November 2003
Resolved 17 March 2004
Resolution: ISE complete, but letter of drydock extension not issued based upon verified hull exam scheduled on or about 19 Mar 04.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 9 October 2003
Resolved
Receive from OCMI extension of drydock examination as per 46 CFR 176.675.
Action required: 701 - Prior to carriage of passengers/cargo
Due 9 November 2003
Resolved 19 March 2004
Engineering › Shafting/Propeller Arrangements
Issued 27 August 2002
Resolved
Make perm rep to propulsion sys(suspected damage to port prop). Until repairs have been corrected, the vsl is limited to 1 voyage w/ passengers. This voyage is auth. to take place between the hrs of 1800 & 2300 on 27AUG02. During this voyage, both MDE's are limited to NMT 1500 RPMs. LEGACY COMPONENT DESC: Propeller (fixed pitch)
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Due 27 September 2002
Resolved 28 August 2002
Lifesaving › Lifebuoys
Issued 22 April 2002
Resolved
Unknown Component - Wasted
Due 22 April 2002
Resolved 26 April 2002
Navigation
Issued 22 April 2002
Resolved
Not working. LEGACY COMPONENT DESC: lights
Due 22 April 2002
Resolved 26 April 2002
Construction/Loadline
Issued 22 April 2002
Resolved
Unknown Component - Loose
Due 22 April 2002
Resolved 26 April 2002
Electrical › Lighting (service)
Issued 22 April 2002
Resolved
Unknown Component - Missing
Due 22 April 2002
Resolved 26 April 2002
Accommodation/Occupational Safety › Other Accommodation Spaces
Issued 22 April 2002
Resolved
Inadequate galley sanitation.
Due 22 April 2002
Resolved 26 April 2002
Accommodation/Occupational Safety › Medical/First Aid
Issued 22 April 2002
Resolved
Replace expired items in first aid kit. LEGACY COMPONENT DESC: Medicine Chest
Due 22 April 2002
Resolved 26 April 2002
Engineering › Bilge Water Management System
Issued 22 April 2002
Resolved
Pump out and clean fuel/oil from p/s engine room and p/s generator spaces.
Due 22 April 2002
Resolved 26 April 2002
Electrical › Electric Supply System (service)
Issued 22 April 2002
Resolved
Remove all dead-end cable. LEGACY COMPONENT DESC: Cable
Due 22 April 2002
Resolved 26 April 2002
Engineering › Fuel Oil Service System
Issued 22 April 2002
Resolved
Repair all fuel leaks from joints in f/o supply piping. LEGACY COMPONENT DESC: Piping
Due 22 April 2002
Resolved 26 April 2002
Construction/Loadline › Penetrations
Issued 22 April 2002
Resolved
Clean gasket and lip for watertight hatch to stbd generator space. LEGACY COMPONENT DESC: Gasket
Due 22 April 2002
Resolved 26 April 2002
Electrical › Electric Supply System (service)
Issued 22 April 2002
Resolved
Replace missing clip for cover of shore tie connection. LEGACY COMPONENT DESC: Cable
Due 22 April 2002
Resolved 26 April 2002
Accommodation/Occupational Safety › Occupational Safety
Issued 22 April 2002
Resolved
Install hand grab for port engine room access and fix missing rung on ladder for port generator space. LEGACY COMPONENT DESC: Hand Grab
Due 22 April 2002
Resolved 26 April 2002
Operations/Management › Lifesaving
Issued 22 April 2002
Resolved
Provide adequate recovery method from stern for persons in water. Current method requires deckhand to pull person up over 2' of freeboard. LEGACY COMPONENT DESC: PIW recovery
Due 22 April 2002
Resolved 26 April 2002
Lifesaving › Lifejacket/PFD (General)
Issued 22 April 2002
Resolved
Install lifejacket donning and lifejacket storage count placards. LEGACY COMPONENT DESC: Storage
Due 22 April 2002
Resolved 26 April 2002
Stability › Incline Test
Issued 22 April 2002
Resolved
Submit required stability calculations for passengers on uppermost deck to MSC for evaluation and issuance of new stability letter.
Due 22 June 2002
Resolved 12 June 2002
Lifesaving
Issued 31 October 2001
Resolved
Vessel may not embark passengers until all outstanding CG-835 requirements are corrected to the satisfaction of the [name withheld].
Condition: Unknown
Due 26 November 2001
Resolved 26 November 2001
Navigation
Issued 28 September 2001
Resolved
Repair or remove the inoperative searchlight prior to vessel operation at night. 46 CFR 184.100
Condition: Unknown
Due 2 October 2001
Resolved 2 October 2001
Construction/Loadline
Issued 28 September 2001
Resolved
Drydock the vessel and conduct an underbody survey for damage caused by grounding. 46 CFR 176.600(d)
Condition: Unknown
Due 2 October 2001
Resolved 2 October 2001
Electrical
Issued 28 September 2001
Resolved
Provide a dripproof enclosure for the distribution panel located on the aftbulkhead stbd side engine room. 46 CFR 183.210
Condition: Unknown
Due 28 September 2001
Resolved 28 September 2001
Electrical
Issued 28 September 2001
Resolved
Provide compression fittings for globe lights on aft engine room bulkheads to ensure dripproof operation. 46 CFR 183.210
Condition: Unknown
Due 28 September 2001
Resolved 28 September 2001
Electrical
Issued 28 September 2001
Resolved
Remove battery and portable battery charger from port side generator space.Battery appears old and requires replacement. 46 CFR 183.200
Condition: Unknown
Due 2 October 2001
Resolved 2 October 2001
Engineering
Issued 28 September 2001
Resolved
Conduct operational tests of both main engines in the presence of a USCG Inpspector.46 CFR 176.840
Condition: Unknown
Due 2 October 2001
Resolved 2 October 2001
Lifesaving
Issued 28 September 2001
Resolved
Remove all paint and flammable material from stbd side generator space. 46 CFR 147.45
Condition: Unknown
Due 2 October 2001
Resolved 2 October 2001
Engineering
Issued 28 September 2001
Resolved
Aerate and remove vapors from #2 port side void containing "old" fuel tank.46 CFR 176.830
Condition: Unknown
Due 2 October 2001
Resolved 2 October 2001
Electrical
Issued 28 September 2001
Resolved
Renew broken guards on overhead light fixtures in stbd generator room and stbd side engine room. 46 CFR 183.410
Condition: Unknown
Due 29 October 2001
Resolved 29 October 2001
Lifesaving
Issued 28 September 2001
Resolved
Check all lifejackets for retroreflectiv tape. Two jackets found w/no tape and one removed from vessel due to wear. 46 CFR 185.604
Condition: Unknown
Due 2 October 2001
Resolved 2 October 2001
Electrical
Issued 28 September 2001
Resolved
Provide a cap/plug for missing blank in stbd side main engin gauge panel. 46 CFR 183.210
Condition: Unknown
Due 28 September 2001
Resolved 28 September 2001
Construction/Loadline
Issued 29 August 2001
Resolved
Ensure that all PVC pipe penetrations of subdivision bulkheads are metallicwith valves on each side of the bulkhead in accordance with your repair proposal dated August 28, 2001. 46 CFR 182.720
Condition: Unknown
Due 29 August 2001
Resolved 29 August 2001
Electrical
Issued 29 August 2001
Resolved
Remove the dead end cable located centerline in the port generator space. 46 CFR 183.340
Condition: Unknown
Due 17 September 2001
Resolved 17 September 2001
Engineering
Issued 29 August 2001
Resolved
Prove proper operation of new port engine and port generator installations to the satisfaction of the attending marine inspector prior to embarking passengers. 46 CFR 182
Condition: Unknown
Due 31 August 2001
Resolved 31 August 2001
Electrical
Issued 29 August 2001
Resolved
Clearly mark and identify the switches on the dual switch switchboard in the stbd generator space. 46 CFR 183.220
Condition: Unknown
Due 4 September 2001
Resolved 4 September 2001
Construction/Loadline
Issued 29 August 2001
Resolved
Provide guards for the rotating parts of bilge pumps located in the generator spaces. 46 CFR 177.960
Condition: Unknown
Due 17 September 2001
Resolved 17 September 2001
Electrical
Issued 29 August 2001
Resolved
Provide metal cable hangers for wire runs throughout the vessel. 46 CFR 183.340
Condition: Unknown
Due 29 August 2001
Resolved 29 August 2001
Electrical
Issued 29 August 2001
Resolved
Repair electrical connection to the overhead light in the stbd generator room to remove exposed wiring. 46 CFR 183.340
Condition: Unknown
Due 4 September 2001
Resolved 4 September 2001
Navigation
Issued 23 July 2001
Resolved
PROVIDE MEANS TO LOCK OUT WING CONTROL STATIONS TO PROTECT INADVERTENT OPERATION BY PASSENGERS.
Condition: Unknown
Due 31 August 2001
Resolved 31 August 2001
Unknown
Issued 9 July 2001
Resolved
Conduct operational test and provide a copy of the report to the attending Coast Guard Marine inspector.
Condition: Unknown
Due 16 July 2001
Resolved 16 July 2001
Engineering
Issued 9 July 2001
Resolved
Provide a copy of all work conducted on the vessels starboard shaft. Provide a copy of all test conducted on new starboard shaft to include alignment and run out test.
Condition: Unknown
Due 16 July 2001
Resolved 16 July 2001
Lifesaving
Issued 15 June 2001
Resolved
PROVIDE FIRST AID EMERGENCY EYEWASH IN VICINITY OF DISINFECTANT TANK FOR MSD.
Condition: Unknown
Due 2 July 2001
Resolved 20 July 2001
Accommodation/Occupational Safety
Issued 15 June 2001
Resolved
INSTALL FLAME SCREEN IN MSD VENT LINE.
Condition: Unknown
Due 2 July 2001
Resolved 20 July 2001
Accommodation/Occupational Safety
Issued 15 June 2001
Resolved
INSTALL CHECK VALVE IN TREATED EFFLUENT DISCHARGE PIPING FOR MSD.
Condition: Unknown
Due 28 June 2001
Resolved 20 July 2001
Engineering
Issued 15 June 2001
Resolved
REPAIR EXHAUST LEAK ON PORT MAIN ENGINE.
Condition: Unknown
Due 28 June 2001
Resolved 20 July 2001
Lifesaving
Issued 15 June 2001
Resolved
PROVIDE FIRST AID KIT THAT CONTAINS ALL OF THE EQUIPMENT REQUIRED BY 46 CFR164.041.
Condition: Unknown
Due 28 June 2001
Resolved 20 July 2001
Construction/Loadline
Issued 15 June 2001
Resolved
MAKE OVERHEAD VAPOR TIGHT IN ALL MACHINERY AND FUAL TANK SPACES.
Condition: Unknown
Due 28 June 2001
Resolved 20 July 2001
Construction/Loadline
Issued 15 June 2001
Resolved
MAKE PERMANENT REPAIRS TO HOLE IN SIDESHELL, PORT HULL WHERE OLD FUEL TANK VENT EXITED HULL. TEMPORARY REPAIRS, I.E. PIPE PLUG, MUST BE COMPLETED PRIOR TO CFARRIAGE OF PASSENGERS.
Condition: Unknown
Due 28 June 2001
Resolved 20 July 2001
Engineering
Issued 15 June 2001
Resolved
RENDER FUEL TANK INOPERABLE AS DISCUSSED WITH COAST GUARD INSPECTOR.
Condition: Unknown
Due 28 June 2001
Resolved 20 July 2001
Electrical
Issued 15 June 2001
Resolved
PROVIDE BLANK FOR DISTRIBUTION PANEL IN STARBOARD ENGINE ROOM.
Condition: Unknown
Due 28 June 2001
Resolved 20 July 2001
Construction/Loadline
Issued 15 June 2001
Resolved
SUBMIT REPAIR PROPOSAL FOR REVIEW AND APPROVAL FOR ALL PVC PIPE PENETRATIONS THROUGH SUBDIVISION BULKHEADS. ALL PENETRATIONS MUST BE METALLIC WITH VALVES ON EACH SIDE OF THE BULKHEAD.
Condition: Unknown
Due 20 July 2001
Resolved 20 July 2001
Lifesaving
Issued 15 June 2001
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 12 July 2001
Resolved 30 July 2001
Accommodation/Occupational Safety
Issued 15 June 2001
Resolved
REPAIR FRESH WATER SYSTEM LEAKS IN STARBOARD GENERATOR ROOM (FORWARD BULKHEAD INBOARD).
Condition: Unknown
Due 20 July 2001
Resolved 20 July 2001
Electrical
Issued 15 June 2001
Resolved
PROVIDE EMERGENCY LIGHTING (FLASHLIGHTS) PRIOR TO NIGHT TIME OPERATION BUT IN NO CASE LATER THAN COMPLIANCE DATE.
Condition: Unknown
Due 28 June 2001
Resolved 20 July 2001
Lifesaving
Issued 15 June 2001
Resolved
PROPERLY LABEL PFD STOWAGE PRIOR TO CARRIAGE OF PASSENGERS BUT IN NO CASE LATER THAN COMPLIANCE DATE.
Condition: Unknown
Due 28 June 2001
Resolved 20 July 2001
Engineering
Issued 15 June 2001
Resolved
RE-LAG BOTH MAIN ENGINE EXHAUST LINES.
Condition: Unknown
Due 12 July 2001
Resolved 30 July 2001
Unknown
Issued 23 September 1997
Resolved
Remove fuel transfer lines running from aft fuel tanks to forward fuel tanks.
Condition: Unknown
Due 26 September 1997
Resolved 26 September 1997
Unknown
Issued 2 August 1997
Resolved
DEWATER AND CLEAN ALL ENGINE ROOM BILGES.
Condition: Unknown
Due 11 August 1997
Resolved 11 August 1997
Unknown
Issued 2 August 1997
Resolved
REPAIR FUEL LEAK IN STARBOARD DETROIT DIESEL ENGINE ROOM, INBOARD OF ENGINE.
Condition: Unknown
Due 5 August 1997
Resolved 5 August 1997
Unknown
Issued 2 August 1997
Resolved
MAKE PERMANENT REPAIR TO PORT DETROIT DIESEL EXHAUST SYSTEM PRIOR TO OPERATION.
Condition: Unknown
Due 11 August 1997
Resolved 11 August 1997
Unknown
Issued 2 August 1997
Resolved
CLEAN PORT DETROIT DIESEL ENGINE ROOM FROM SMOKE DAMAGE.
Condition: Unknown
Due 11 August 1997
Resolved 11 August 1997
Unknown
Issued 2 August 1997
Resolved
RENEW PORT JET-INTAKE PRESSURE SWITCH.
Condition: Unknown
Due 5 August 1997
Resolved 5 August 1997
Unknown
Issued 2 August 1997
Resolved
RENEW OUTBOARD AFT ENGINE MOUNT FOR STARBOARD 'MAN' ENGINE.
Condition: Unknown
Due 2 August 1997
Resolved 2 August 1997
Unknown
Issued 2 August 1997
Resolved
DETERMINE IF WATER WEEPAGE FROM TOP OF JETS AT RAM FOR BUCKET CONTROL IS NORMAL, PER MANUFACTURER.
Condition: Unknown
Due 2 August 1997
Resolved 2 August 1997
Unknown
Issued 2 August 1997
Resolved
PROVIDE STUDS OF PROPER LENGTH FOR PORT SHAFT PACKING GLAND, PRIOR TO OPERATION.
Condition: Unknown
Due 11 August 1997
Resolved 11 August 1997
Unknown
Issued 2 August 1997
Resolved
ADJUST PORT AND STARBOARD PACKING GLANDS FOR NORMAL RUNNING TEMPERATURE, PRIOR TO OPERATION.
Condition: Unknown
Due 11 August 1997
Resolved 11 August 1997
Unknown
Issued 2 August 1997
Resolved
DETERMINE SOURCE OF WATER IN FORWARD ENGINE ROOMS AND PROPERLY CORRECT.
Condition: Unknown
Due 5 August 1997
Resolved 5 August 1997
Unknown
Issued 2 August 1997
Resolved
TRIM AND REFASTEN STARBOARD SHAFT PACKING GLAND WATER INJECTION HOSE, PRIORTO OPERATION.
Condition: Unknown
Due 11 August 1997
Resolved 11 August 1997
Unknown
Issued 2 August 1997
Resolved
MAKE PROPER REPAIR TO CRACK ON STARBOARD MSD TANK.
Condition: Unknown
Due 11 August 1997
Resolved 11 August 1997
Unknown
Issued 2 August 1997
Resolved
PROVIDE SCHEMATIC PLAN OF FUEL SYSTEM AND EXPLANATION FOR OVERFLOW OF FORWARD FUEL TANK WHEN AFT EMERGENCY SHUTOFF IS OPEN.
Condition: Unknown
Due 2 August 1997
Resolved 2 August 1997
Unknown
Issued 1 August 1997
Resolved
GRIND OUT SCARRED AREAS OF BOTTOM LONGITUDINALS PRIOR TO REINSTALLING DRIVESHAFT.
Condition: Unknown
Due 5 August 1997
Resolved 5 August 1997
Unknown
Issued 1 August 1997
Resolved
PROVE PROPER OPERATION OF STARBOARD DETROIT DIESEL DRIVE TRAIN, PRIOR TO OPERATION OF ENGINE.
Condition: Unknown
Due 5 August 1997
Resolved 5 August 1997
Unknown
Issued 1 August 1997
Resolved
MAKE PROPER REPAIRS TO STARBOARD RUDDER ASSEMBLY PACKING GLAND, PRIOR TO OPERATION OF VESSEL.
Condition: Unknown
Due 5 August 1997
Resolved 5 August 1997
Unknown
Issued 1 August 1997
Resolved
PERMANENTLY REPAIR EXHAUST LEAK FROM STARBOARD DETROIT DIESEL ENGINE, PRIORTO OPERATING THAT ENGINE.
Condition: Unknown
Due 11 August 1997
Resolved 11 August 1997
Unknown
Issued 15 June 1997
Resolved
PRIOR TO OPERATION, PROVIDE DIVERS REPORT OF CONDITION OF ALL UNDERBODY STRUCTURES, OR DRYDOCK VESSEL WITH USCG ATTENDANCE.
Condition: Unknown
Due 18 June 1997
Resolved 18 June 1997
Unknown
Issued 15 June 1997
Resolved
PRIOR TO OPERATING STARBOARD 'MAN' ENGINE, DETERMINE CAUSE OF HEAVY VIBRATION AND MAKE REPAIRS TO SATISFACTION OF ATTENDING MARINE INSPECTOR.
Condition: Unknown
Due 18 June 1997
Resolved 18 June 1997
Unknown
Issued 15 June 1997
Resolved
PRIOR TO OPERATING STARBOARD 'MAN' ENGINE, REMOVE EXHAUST EXPANSION JOINT AND EXAMINE FOR CRACKING, RENEWING IF NECESSARY.
Condition: Unknown
Due 18 June 1997
Resolved 18 June 1997
Electrical
Issued 2 June 1997
Resolved
REMOVE VISE-GRIPS HOLDING BATTERY WIRE TO BATTERY TERMINAL AND REPLACE WITHPROPER TERMINAL CONNECTOR.
Condition: Unknown
Due 25 June 1997
Resolved 25 June 1997
Electrical
Issued 2 June 1997
Resolved
PROPERLY RUN ELECTRICAL CABLE IN MACHINERY SPACE TO BRING OUT OF BILGES ANDADD CHAFING GEAR WHERE NEEDED.
Condition: Unknown
Due 25 June 1997
Resolved 25 June 1997
Lifesaving
Issued 2 June 1997
Resolved
PROVIDE FIRST AID KIT IAW 46CFR160.041, OR EQUIVALENT.
Condition: Unknown
Due 25 June 1997
Resolved 25 June 1997
Accommodation/Occupational Safety
Issued 2 June 1997
Resolved
CLEAN BILGES OF FUEL AND DEBRIS, IN ALL MACHINERY SPACES.
Condition: Unknown
Due 25 June 1997
Resolved 25 June 1997
Electrical
Issued 2 June 1997
Resolved
REPAIR FUEL LINES ON GENERATOR AND STBD CROSS-OVER LINE FROM GENERATOR FUELTANK TO FWD FUEL TANK.
Condition: Unknown
Due 25 June 1997
Resolved 25 June 1997
Documentation
Issued 2 June 1997
Resolved
PROVIDE PROOF OF RANDOM DRUG TESTING POLICY AND PARTICIPATION IN EAP.
Condition: Unknown
Due 2 July 1997
Resolved 2 July 1997
Accommodation/Occupational Safety
Issued 2 June 1997
Resolved
REPLACE WASTE RECEPTICLES WITH ALL METAL CANS IAW 46CFR177.405(f).
Condition: Unknown
Due 25 June 1997
Resolved 25 June 1997
Engineering
Issued 2 June 1997
Resolved
INSTALL INSULATION ON DETROIT MAIN ENGINES EXHAUST PORT AND STARBOARD SIDES.
Condition: Unknown
Due 25 June 1997
Resolved 25 June 1997
Lifesaving
Issued 2 June 1997
Resolved
MODIFY MAN-OVERBOARD RESCUE PROCEDURES TO INCLUDE SECURING PROPELLORS DURING STERN PICK-UP.
Condition: Unknown
Due 25 June 1997
Resolved 25 June 1997
Engineering
Issued 2 June 1997
Resolved
DETERMINE CAUSE OF VIBRATION IN STBD SHAFT AND MAKE NECESSARY REPAIRS.
Condition: Unknown
Due 25 June 1997
Resolved 25 June 1997
Documentation
Issued 2 June 1997
Resolved
PROVIDE ORIGINAL CERTIFICATE OF INSPECTION ONBOARD THE VESSEL.
Condition: Unknown
Due 25 June 1997
Resolved 25 June 1997
Engineering
Issued 2 June 1997
Resolved
REPAIR/REPLACE EMERGENCY FUEL SHUTOFFS FOR ALL ENGINES, TO ALLOW SMOOTH ANDCOMPLETE OPERATION.
Condition: Unknown
Due 25 June 1997
Resolved 25 June 1997
Accommodation/Occupational Safety
Issued 2 June 1997
Resolved
INSTALL SIGN REQUIRING BOTH HATCHES FOR DETROIT MACHINERY SPACE TO BE DOGGED OPEN WHILE SPACE IS OCCUPIED.
Condition: Unknown
Due 25 June 1997
Resolved 25 June 1997
Accommodation/Occupational Safety
Issued 2 June 1997
Resolved
CLEAR OBSTRUCTIONS FROM AND PROPERLY MARK EMERGENCY ESCAPE ROUTES FROM DETROIT MACHINERY SPACE.
Condition: Unknown
Due 25 June 1997
Resolved 25 June 1997
Engineering
Issued 2 June 1997
Resolved
INSTALL GUARDS AROUND ROTATING MACHINERY IN ALL FOUR MACHINERY SPACES._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 25 June 1997
Resolved 25 June 1997
Accommodation/Occupational Safety
Issued 2 June 1997
Resolved
INSTALL RAILS/NETTING AT PORT AND STARBOARD MID-SHIPS DOORS TO PREVENT FALLING OVERBOARD.
Condition: Unknown
Due 25 June 1997
Resolved 25 June 1997
Fire Fighting
Issued 2 June 1997
Resolved
REPLACE OR PROVE THROUGH HYDRO THAT AFT FIREHOSE IS SATISFACTORY FOR SERVICE.
Condition: Unknown
Due 25 June 1997
Resolved 25 June 1997
Electrical
Issued 2 June 1997
Resolved
PROVIDE DRIPPROOF RECEPTICLES AND ELECTRICAL BOXES FOR ALL MACHINERY SPACES.
Condition: Unknown
Due 25 June 1997
Resolved 25 June 1997
Unknown
Issued 1 November 1996
Resolved
DOUBLE NUT PACKING GLANDS FOR PROPELLOR SHAFTS FROM MAN ENGINES, PRIOR TO OPERATING.
Condition: Unknown
Due 1 November 1996
Resolved 1 November 1996
Unknown
Issued 1 November 1996
Resolved
REMOVE EXCESS OIL AND WATER FROM BILGES OF ALL ENGINE ROOMS._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 1 November 1996
Resolved 1 November 1996
Unknown
Issued 1 November 1996
Resolved
DETERMINE IF VIBRATION OF STARBOARD MAN DIESEL ENGINE IS WITHIN OPERATING NORMS OF MANUFACTURER, AND IF NOT, DETERMINE CAUSE OF EXCESSIVE VIBRATION AND MAKE PERMANENT REPAIR. PRIOR TO ANY REPAIR, A WRITTEN REPORT SHALL BE SUBMITTED TO THE COGNIZANT OCMI WITH FINDINGS AND PROPOSALS FOR REPAIR.
Condition: Unknown
Due 1 November 1996
Resolved 1 November 1996
Unknown
Issued 25 October 1996
Resolved
MAKE PERMANENT REPAIR TO CRACKS AT RUDDER INSERTS IN BOTTOM SHELL, PORT ANDSTARBOARD. THIS TO BE COMPLETED PRIOR TO REFLOATING VESSEL.
Condition: Unknown
Due 1 November 1996
Resolved 1 November 1996
Unknown
Issued 3 October 1996
Resolved
MAKE PERMANENT REPAIR TO CRACK IN STARBOARD HULL, INBOARD CHINE OF MAIN ENGINE ROOM, APPROXIMATELY 1 FOOT AFT OF RACOR FILTERS._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 3 October 1996
Resolved 3 October 1996
Unknown
Issued 3 October 1996
Resolved
MAKE PERMANENT REPAIR TO CORRODED WELDS AT JUNCTURE OF HULLS TO WING, MANY LOCATIONS IN MAIN ENGINE ROOMS.
Condition: Unknown
Due 3 October 1996
Resolved 3 October 1996
Unknown
Issued 3 October 1996
Resolved
PERMANENTLY REPAIR EXHAUST LEAKS FROM BOTH DETROIT DIESEL ENGINES IN LAZARETTE SPACES.
Condition: Unknown
Due 3 October 1996
Resolved 3 October 1996
Unknown
Issued 3 October 1996
Resolved
MAKE PERMANENT REPAIR TO BOTH BENT RUDDERS.
Condition: Unknown
Due 3 October 1996
Resolved 3 October 1996
Engineering
Issued 18 September 1996
Resolved
DETERMINE THE CAUSE OF THE UNUSUAL VIBRATION IN THE STBD MAIN ENGINE SHAFTING. SUBMIT A WRITTEN REPORT TO THE COGNIZANT [name withheld] OF THE VIBRATION ALONG WITH A PROPOSAL FOR REPAIR.
Condition: Unknown
Due 18 September 1996
Resolved 18 September 1996
Navigation
Issued 18 September 1996
Resolved
ISSUED VERBAL REQUIREMENT TO REPAIR STEERING SYSTEM HYDRAULIC PIPING TO THESATISFACTION OF ATTENDING MARINE INSPECTOR PRIOR TO CARRYING PASSENGERS.
Condition: Unknown
Due 20 September 1996
Resolved 20 September 1996
Accommodation/Occupational Safety
Issued 5 June 1996
Resolved
LABEL LIFE PRESERVER STOWAGE PRIOR TO TAKING PSGRS.
Condition: Unknown
Due 5 June 1996
Resolved 5 June 1996
Electrical
Issued 5 June 1996
Resolved
PROVIDE INTERLOCK BAR FOR GENERATOR/SHORE POWER.
Condition: Unknown
Due 5 June 1996
Resolved 5 June 1996
Electrical
Issued 5 June 1996
Resolved
PROVIDE PROPER WIRE SUPPORTS/STRAPS.
Condition: Unknown
Due 5 June 1996
Resolved 5 June 1996
Accommodation/Occupational Safety
Issued 5 June 1996
Resolved
SECURE TABLES AND CHAIRS THROUGHOUT VSL PRIOR TO TAKING PSGRS.
Condition: Unknown
Due 5 June 1996
Resolved 5 June 1996
Construction/Loadline
Issued 5 June 1996
Resolved
SECURE BI8LGE PIPING AND FIRE MAIN PIPE.
Condition: Unknown
Due 5 June 1996
Resolved 5 June 1996
Engineering
Issued 26 May 1995
Resolved
PRIOR TO CARRIAGE OF PASSENGERS FOR HIRE, PROVE PROPER OPERATION OF PORT AND STARBOARD MAIN ENGINES.
Condition: Unknown
Due 2 June 1995
Resolved 30 May 1995
Navigation
Issued 6 April 1995
Resolved
Provide drawing of mechanical/hydraulic steering system.
Condition: Unknown
Due 6 April 1995
Resolved 6 April 1995
Engineering
Issued 6 April 1995
Resolved
Permanently mount hot water heater system and prove operation to attending marine inspector.
Condition: Unknown
Due 6 April 1995
Resolved 6 April 1995
Documentation
Issued 6 April 1995
Resolved
Provide proper waste management log.
Condition: Unknown
Due 30 April 1995
Resolved 11 April 1995
Navigation
Issued 6 April 1995
Resolved
Provide a 11.8 inch or larger bell.
Condition: Unknown
Due 30 April 1995
Resolved 11 April 1995
Lifesaving
Issued 6 April 1995
Resolved
Provide proper emergency checkoff list on each passenger deck.
Condition: Unknown
Due 30 April 1995
Resolved 11 April 1995
Electrical
Issued 6 April 1995
Resolved
Remove lights fixed under fwd main engines.
Condition: Unknown
Due 30 April 1995
Resolved 11 April 1995
Accommodation/Occupational Safety
Issued 6 April 1995
Resolved
Replace rung on ladder to stbd aft engineroom.
Condition: Unknown
Due 30 April 1995
Resolved 11 April 1995
Electrical
Issued 6 April 1995
Resolved
Properly line and cover all battery boxes.
Condition: Unknown
Due 30 April 1995
Resolved 11 April 1995
Fire Fighting
Issued 6 April 1995
Resolved
Prove proper operation of fire pump (adequate pressure).
Condition: Unknown
Due 30 April 1995
Resolved 11 April 1995
Lifesaving
Issued 6 April 1995
Resolved
Repaint vsl name and capacity on all life floats.
Condition: Unknown
Due 30 April 1995
Resolved 11 April 1995
Navigation
Issued 6 April 1995
Resolved
Provide charts for Willamette River up to Willamette River Dam.
Condition: Unknown
Due 30 April 1995
Resolved 11 April 1995
Navigation
Issued 6 April 1995
Resolved
Provide proper relief valve for air receiver for air horn, with demonstration.
Condition: Unknown
Due 30 April 1995
Resolved 11 April 1995
Lifesaving
Issued 6 April 1995
Resolved
Repaint vsl name on lifering on upperdeck.
Condition: Unknown
Due 30 April 1995
Resolved 11 April 1995
Lifesaving
Issued 6 April 1995
Resolved
Provide one additional child PFD.
Condition: Unknown
Due 30 April 1995
Resolved 11 April 1995
Lifesaving
Issued 6 April 1995
Resolved
Provide proper sign for donning on PFDs at storage stations.
Condition: Unknown
Due 30 April 1995
Resolved 11 April 1995
Lifesaving
Issued 6 April 1995
Resolved
Properly replace sign for child PFDs.
Condition: Unknown
Due 30 April 1995
Resolved 11 April 1995
Documentation
Issued 6 April 1995
Resolved
Provide proper waste management plan.
Condition: Unknown
Due 30 April 1995
Resolved 11 April 1995
Accommodation/Occupational Safety
Issued 6 April 1995
Resolved
Remove heating system from fwd void, stbd side.
Condition: Unknown
Due 30 April 1995
Resolved 11 April 1995
Documentation
Issued 6 April 1995
Resolved
Provide current FCC operators license.
Condition: Unknown
Due 30 April 1995
Resolved 11 April 1995
Accommodation/Occupational Safety
Issued 2 June 1994
Resolved
SUBMIT THREE COPIES OF THE PLANS FOR THE TYPE II MSD SYSTEM INSTALLED ON THE VESSEL TO THE [name withheld], OREGON.
Condition: Unknown
Due 2 June 1994
Resolved 2 June 1994
Lifesaving
Issued 14 April 1993
Resolved
Repair or replace the two top buoyant apparatus.
Condition: Unknown
Due 4 June 1993
Resolved 4 June 1993
Lifesaving
Issued 14 April 1993
Resolved
Make the four buoyant apparatus so that they will float free.
Condition: Unknown
Due 14 May 1993
Resolved 4 June 1993
Lifesaving
Issued 14 April 1993
Resolved
Revise the emergency check list to reflect the systems on board.
Condition: Unknown
Due 14 May 1993
Resolved 4 June 1993
Lifesaving
Issued 14 April 1993
Resolved
Replace the ring buoy on the port side on the aft deck.
Condition: Unknown
Due 14 May 1993
Resolved 4 June 1993
Lifesaving
Issued 14 April 1993
Resolved
Repair or replace the ring buoy on the starboard side on the aft deck.
Condition: Unknown
Due 14 May 1993
Resolved 4 June 1993
Fire Fighting
Issued 14 April 1993
Resolved
Replace the fire hose on the upper deck fire station.
Condition: Unknown
Due 14 May 1993
Resolved 4 June 1993
Accommodation/Occupational Safety
Issued 14 April 1993
Resolved
Install locks on two Marine Sanitation holding tanks overboard discharge valves.
Condition: Unknown
Due 14 May 1993
Resolved 4 June 1993
Construction/Loadline
Issued 20 May 1992
Resolved
REPLACE WINDOW ON BRIDGE STARBOARD FORWARD WINDOW.
Condition: Unknown
Due 5 June 1992
Resolved 5 June 1992
Documentation
Issued 20 May 1992
Resolved
PROVIDE PROOF OF A RANDOM DRUG TESTING PROGRAM.
Condition: Unknown
Due 20 May 1992
Resolved 20 May 1992
Electrical
Issued 20 May 1992
Resolved
REWIRE THE ELECTRICAL BILGE PUMPS IN THE AFTER PORT AND STARBOARD ENGINE ROOMS.
Condition: Unknown
Due 20 May 1992
Resolved 20 May 1992
Lifesaving
Issued 20 May 1992
Resolved
HOLD A FIRE AND MANOVERBOARD DRILL WITH THE OPERATING CREW.
Condition: Unknown
Due 20 May 1992
Resolved 20 May 1992
Construction/Loadline
Issued 8 November 1991
Resolved
Replace broken window in piolt house froward center.
Condition: Unknown
Due 8 November 1991
Resolved 8 November 1991
Construction/Loadline
Issued 8 November 1991
Resolved
Make permanent repairs to the upper rubrail on the port side and the cracked wild forward on the same rubrail.
Condition: Unknown
Due 8 November 1991
Resolved 8 November 1991
Construction/Loadline
Issued 8 November 1991
Resolved
make permenant repairs to the window frame starboard side forward main salon.
Condition: Unknown
Due 8 November 1991
Resolved 8 November 1991
Electrical
Issued 8 November 1991
Resolved
Replace household electrical wire whith approved boat wire in the followinglocations; light in storeage space under stairs, outlets forward port and starboard , and fans port and starboard forward on the main deck in main salon.
Condition: Unknown
Due 8 November 1991
Resolved 8 November 1991
Construction/Loadline
Issued 20 September 1991
Resolved
Unknown Component - Unknown Cause/Condition
Condition: Unknown
Due 20 September 1991
Resolved 20 September 1991
Construction/Loadline
Issued 20 September 1991
Resolved
Unknown Component - Unknown Cause/Condition
Condition: Unknown
Due 20 September 1991
Resolved 20 September 1991
Engineering
Issued 20 September 1991
Resolved
Unknown Component - Unknown Cause/Condition
Condition: Unknown
Due 20 September 1991
Resolved 20 September 1991
Construction/Loadline
Issued 20 September 1991
Resolved
Unknown Component - Unknown Cause/Condition
Condition: Unknown
Due 20 September 1991
Resolved 20 September 1991
Construction/Loadline
Issued 20 September 1991
Resolved
Unknown Component - Unknown Cause/Condition
Condition: Unknown
Due 20 September 1991
Resolved 20 September 1991
Construction/Loadline
Issued 20 September 1991
Resolved
Unknown Component - Unknown Cause/Condition
Condition: Unknown
Due 20 September 1991
Resolved 9 October 1991
Construction/Loadline
Issued 4 April 1991
Resolved
Replace all broken or cracked windows on the vessel.
Condition: Unknown
Due 4 April 1991
Resolved 4 April 1991
Construction/Loadline
Issued 15 March 1991
Resolved
Make all heater hose penetrations through the deck or bulkheads are to be changed to a metallic fitting with valves in the ten deck penetrations and the six bulkhead penetrations as per 46 CFR 182.40-1(a)(i),and the deck penetrations inthe two heads.
Condition: Unknown
Due 15 March 1991
Resolved 15 March 1991
Electrical
Issued 11 May 1989
Resolved
PROPERLY SECURE SERV GENERATOR FUEL LINE IN THE ENGINEROOM.
Condition: Unknown
Due 11 May 1989
Resolved 11 May 1989
Engineering
Issued 11 May 1989
Resolved
PLACE GUARDS OVER SHAFT COUPLINGS ON BOTH PORT AND STBD ENGINES
Condition: Unknown
Due 11 May 1989
Resolved 11 May 1989
Electrical
Issued 19 May 1988
Resolved
INSTALL COVERS ON BATTERY BOXS IN BOTH ENGINE ROOMS.
Condition: Unknown
Due 19 May 1988
Resolved 19 May 1988
Navigation
Issued 19 May 1988
Resolved
PLACE NUT ON AND SECURE STEERING ARM ON STARBOARD JET DRIVE UNIT.
Condition: Unknown
Due 19 May 1988
Resolved 19 May 1988
Construction/Loadline
Issued 19 May 1988
Resolved
INSTALL 2 SEA VALVES ON ELECTRIC BILGE PUMPS IN PORT AND STARBOARD ENGINE ROOMS.
Condition: Unknown
Due 19 May 1988
Resolved 19 May 1988
Engineering
Issued 19 May 1988
Resolved
INSTALL PERMANENT EXHAUST SYSTEM MOUNTING BRACKETS.
Condition: Unknown
Due 19 May 1988
Resolved 19 May 1988
Engineering
Issued 19 May 1988
Resolved
REPAIR EXHAUST PIPING AT STARBOARD MAIN ENGINE AND INSULATE.
Condition: Unknown
Due 19 May 1988
Resolved 19 May 1988
Electrical
Issued 19 May 1988
Resolved
INSTALL WATER TEMPERATURE AND OIL PRESSURE GAUGES TO AUX DIESEL GENERATOR.
Condition: Unknown
Due 19 May 1988
Resolved 19 May 1988
Construction/Loadline
Issued 19 May 1988
Resolved
COMPLETE WELDING IN BOTTOM PLATE, PORT FUEL TANK COMPT.
Condition: Unknown
Due 19 May 1988
Resolved 19 May 1988