MAURY USCG vessel records Sign in
← All vessels

ULTIMATE

ULTIMATE is a 1987 passenger vessel (inspected). The Coast Guard has recorded 66 inspections since 1987, most recently in March 2026, along with 82 deficiencies and 1 casualty investigation in 2005.

Records from 1987 to 2026. Most recent: inspection, 23 March 2026.

Built
1987
Last inspected
23 March 2026
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDP5515
288054
Flag
UNITED STATES
368364120
Maury page id
psix-288054

Inspections, by type

…with no type recorded6
Years with a record 37 calendar years (1987–2026)
The 66 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)55.8 ft × 17.0 ft × 6.6 ft
Registered tonnagegross 41 / net 33
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderWESTPORT SHIPYARD INC · WESTPORT, WA, UNITED STATES · built 1987
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portHOMER, AK
Trade endorsementsCoastwise, unrestricted, Fishery, Registry
DocumentationValid · issued 13 April 2026 · expires 31 March 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it41 - Simplified, Gross Ton
33 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDP5515MMSI 368364120 · active · compulsorily equipped · granted 25 April 2024, expires 25 April 2034
WDI2086MMSI 367674570 · expired · compulsorily equipped · granted 27 May 2015, cancelled 28 June 2025
WCZ7664MMSI not assigned · expired · voluntarily equipped · granted 20 April 2000, cancelled 26 June 2010
WCX4416MMSI not assigned · expired · voluntarily equipped · granted 1 May 1997, cancelled 1 July 2007
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspected as a tow unit · 1

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

BLUE FOX Passenger (Uninspected) · MISLE 780012 · 13 July 2005 · activity 2444463

Inspection history · 66

23 March 2026 Drydock Exam · Internal Structural Exam · Examination of Repairs · Administrative Inspection · COI Inspection
Physical examination · Marine Safety Detachment Homer · USCG Arctic District (CGD-A) · Activity 8330777
4 June 2025 Annual Inspection · Administrative Inspection · Damage Survey
Physical examination · Marine Safety Detachment Homer · USCG Arctic District (CGD-A) · Activity 8152438
15 May 2024 Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Detachment Homer · USCG Arctic District (CGD-A) · Activity 7912929
31 January 2024 Drydock Exam · Examination of Repairs · Internal Structural Exam
Physical examination · Marine Safety Detachment Homer · USCG Arctic District (CGD-A) · Activity 7858654
3 May 2023 Annual Inspection · Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Homer · USCG Arctic District (CGD-A) · Activity 7684717
18 August 2022 In-Service Inspection · Administrative Inspection
Physical examination · Marine Safety Detachment Homer · USCG Arctic District (CGD-A) · Activity 7537259
1 June 2022 Annual Inspection · Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Detachment Homer · USCG Arctic District (CGD-A) · Activity 7470976
13 April 2022 Examination of Repairs · Administrative Inspection
Physical examination · Marine Safety Detachment Homer · USCG Arctic District (CGD-A) · Activity 7429959
8 March 2022 Drydock Exam · Administrative Inspection · Internal Structural Exam
Physical examination · Marine Safety Detachment Homer · USCG Arctic District (CGD-A) · Activity 7408378
24 August 2021 Administrative Inspection · In-Service Inspection
Physical examination · Marine Safety Detachment Homer · USCG Arctic District (CGD-A) · Activity 7295384
14 August 2021 Type not recorded
No type recorded · Maritime Safety & Security Team San Francisco (91105) · Activity 7287981
29 May 2021 Type not recorded
No type recorded · USCGC CHANDELEUR (WPB 1319) · USCG Arctic District (CGD-A) · Activity 7219747
5 May 2021 COI Inspection · Administrative Inspection · DAPI Audit · Deficiency Check
Physical examination · Marine Safety Detachment Homer · USCG Arctic District (CGD-A) · Activity 7190039
30 April 2020 DAPI Audit · Deficiency Check · Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Detachment Homer · USCG Arctic District (CGD-A) · Activity 6946622
12 March 2020 Internal Structural Exam · Administrative Inspection · Drydock Exam
Physical examination · Marine Safety Detachment Homer · USCG Arctic District (CGD-A) · Activity 6925763
3 October 2019 In-Service Inspection · Administrative Inspection
Physical examination · Marine Safety Detachment Homer · USCG Arctic District (CGD-A) · Activity 6827438
10 May 2019 DAPI Audit · Deficiency Check · Annual Inspection
Physical examination · Marine Safety Detachment Homer · USCG Arctic District (CGD-A) · Activity 6699591
14 May 2018 Annual Inspection
Physical examination · Marine Safety Detachment Homer · USCG Arctic District (CGD-A) · Activity 6408589
6 April 2018 Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Detachment Homer · USCG Arctic District (CGD-A) · Activity 6386807
22 May 2017 Annual Inspection
Physical examination · Marine Safety Detachment Homer · USCG Arctic District (CGD-A) · Activity 6150312
30 January 2017 Deficiency Check
Physical examination · Marine Safety Detachment Homer · USCG Arctic District (CGD-A) · Activity 6080027
9 May 2016 COI Inspection
Physical examination · Marine Safety Detachment Homer · USCG Arctic District (CGD-A) · Activity 5873054
19 April 2016 Liferaft Servicing
Physical examination · Marine Safety Detachment Homer · USCG Arctic District (CGD-A) · Activity 5864712
23 February 2016 Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Detachment Homer · USCG Arctic District (CGD-A) · Activity 5820551
5 October 2015 Administrative Inspection
Administrative · Marine Safety Detachment Homer · USCG Arctic District (CGD-A) · Activity 5736175
16 May 2014 Annual Inspection
Physical examination · Marine Safety Detachment Homer · USCG Arctic District (CGD-A) · Activity 4877318
3 February 2012 Administrative Inspection
Administrative · Marine Safety Detachment Kenai · USCG Arctic District (CGD-A) · Activity 4238092
18 January 2012 Administrative Inspection
Administrative · Marine Safety Detachment Kenai · USCG Arctic District (CGD-A) · Activity 4227267
1 December 2011 Administrative Inspection
Administrative · Marine Safety Detachment Kenai · USCG Arctic District (CGD-A) · Activity 4200572
24 June 2008 Administrative Inspection
Administrative · Marine Safety Detachment Kenai · USCG Arctic District (CGD-A) · Activity 3246570
12 June 2008 DAPI Audit · Annual Inspection
Physical examination · Marine Safety Detachment Kenai · USCG Arctic District (CGD-A) · Activity 3241657
3 April 2008 Internal Structural Exam · Hull Examination
Physical examination · Marine Safety Detachment Kenai · USCG Arctic District (CGD-A) · Activity 3177235
22 May 2007 Annual Inspection
Physical examination · Marine Safety Detachment Kenai · USCG Arctic District (CGD-A) · Activity 2955629
22 April 2006 Hull Examination · COI Inspection
Physical examination · Marine Safety Detachment Kenai · USCG Arctic District (CGD-A) · Activity 2631258
13 July 2005 Type not recorded
No type recorded · Marine Safety Detachment Kenai · USCG Arctic District (CGD-A) · Activity 2444463
10 May 2005 Re-Inspection
Physical examination · Marine Safety Detachment Kenai · USCG Arctic District (CGD-A) · Activity 2382608
16 April 2004 Re-Inspection · Hull Examination
Physical examination · Marine Safety Detachment Kenai · USCG Arctic District (CGD-A) · Activity 2048443
2 May 2003 Re-Inspection
Physical examination · Marine Safety Detachment Kenai · USCG Arctic District (CGD-A) · Activity 1790204
29 April 2002 Re-Inspection · Hull Examination
Physical examination · Marine Safety Detachment Kenai · USCG Arctic District (CGD-A) · Activity 1632938
24 August 2001 Administrative
Administrative · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1073124
20 June 2001 Deficiency Check
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1067972
15 May 2001 COI Inspection
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1373488
24 July 2000 Deficiency Check
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1051735
24 May 2000 Re-Inspection
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1373045
6 April 2000 Hull Examination
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1379025
27 May 1999 Deficiency Check
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 802111
5 April 1999 COI Inspection
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1378633
13 April 1998 Hull Examination · Re-Inspection
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1125704
9 April 1997 Re-Inspection
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1094776
9 April 1996 COI Inspection · Hull Examination
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1078639
2 May 1995 MARPOL Annex V Examination · Re-Inspection
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1034332
11 April 1994 Hull Examination
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1423906
5 April 1994 Re-Inspection
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1423907
18 March 1993 COI Inspection
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1415810
12 May 1992 Type not recorded
No type recorded · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 955683
21 April 1992 Re-Inspection
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1262930
17 March 1992 Hull Examination
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 957515
23 May 1991 Re-Inspection
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1242175
21 March 1990 Hull Examination · COI Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 913084
19 April 1989 Re-Inspection · Hull Examination
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1203436
16 November 1988 Drydock Extension
Administrative · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1205011
8 September 1988 Administrative
Administrative · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1041193
5 May 1988 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1346330
21 April 1988 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1342008
7 March 1988 Re-Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1029843
23 June 1987 Initial Certification
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1329342

Deficiency record · 82

07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 1 June 2022 Resolved
All machinery in engine room is required to shut down with fire fighting activation. Generator did not shutdown. Ensure generator shuts down.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 July 2022
Resolved 30 June 2022
05 - Radio Communications › N/A - No Subsystem › Main installation
Issued 1 June 2022 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 July 2022
Resolved 30 June 2022
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Other (Conditions of employment)
Issued 1 June 2022 Resolved
Provide proof of enrollment in CG approved drug testing program for each of the crew.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 July 2022
Resolved 30 June 2022
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 5 May 2021 Resolved
The forward bilge pump visual indicator remains on in automatic mode. Re-wire so the indicator light only comes on when the pump is running.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 May 2021
Resolved 5 May 2021
Resolution: re-wired
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 5 May 2021 Resolved
Vessel needs to have the required amount of distress signals for its route and condition.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 May 2021
Resolved 5 May 2021
Resolution: corrected
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 5 May 2021 Resolved
Replace all expired medicines found in the first aid kit that is required to be onboard.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 May 2021
Resolved 5 May 2021
Resolution: replaced
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 5 May 2021 Resolved
Post all types of lifejacket donning placards that represent each type of lifejacket carried onboard.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 May 2021
Resolved 5 May 2021
Resolution: corrected
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 5 May 2021 Resolved
Replace all lights found extinguished in the accomodation space.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 May 2021
Resolved 5 May 2021
Resolution: replaced
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 5 May 2021 Resolved
Replace all fire detection monitors that were found inoperable.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 May 2021
Resolved 5 May 2021
Resolution: replaced
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 10 June 2020 Resolved
Vessel required to have liferaft capacity for 33 persons. Vessel restricted to carry a maximum of 25 passengers only.
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 5 May 2021
Resolution: corrected
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 10 June 2020 Resolved
EPIRB found out of service with expired battery and hydrostatic release unit.
Action required: 705 - Other - as specified
Resolved 16 June 2020
Resolution: Replaced hydrostatic unit and battery.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 10 June 2020 Resolved
Ring Buoy deemed un-serviceable due to its condition.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 June 2020
Resolved 11 June 2020
Resolution: Vessel replaced the ring buoy with one in serviceable condition.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 10 June 2020 Resolved
Loose rail base found on the aft/centerline deck rail where it meets the transom. Needs to be secure.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 June 2020
Resolved 11 June 2020
Resolution: Properly re-secured the deck rail to the transom.
09 - Working and Living Conditions › 091 - Living Conditions › Other (crew and accommodation)
Issued 10 June 2020 Resolved
Provide a waste management plan for the vessel.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 June 2020
Resolved 16 June 2020
Resolution: Proof of waste management plan provided.
04 - Emergency Systems › N/A - No Subsystem › Emergency towing arrangements and procedures
Issued 10 June 2020 Resolved
Emergency instruction list to be posted onboard the vessel.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 June 2020
Resolved 16 June 2020
Resolution: Vessel posted a copy of their emergency instruction list.
05 - Radio Communications › N/A - No Subsystem › Distress messages: obligations and procedures
Issued 10 June 2020 Resolved
Post the emergency broadcast placard near the helm station.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 June 2020
Resolved 11 June 2020
Resolution: The emergency broadcast placard is posted at the helm station.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 10 June 2020 Resolved
Forward bilge pump needs to have a visual indicator when the pump is running.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 June 2020
Resolved 16 June 2020
Resolution: The forward bilge pump indicator light was replaced.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 10 June 2020 Resolved
Emergency exits need to be clearly labeled at each point of entry/exit in the overnight accomodation space.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 June 2020
Resolved 16 June 2020
Resolution: Exits and entries clearly marked at all points of access within the overnight accomodation space.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 10 June 2020 Resolved
Replace all expired medicines.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 June 2020
Resolved 16 June 2020
Resolution: All expired medicines have been replaced.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 10 May 2019 Resolved
Retro on lifering was worn and needs to be replaced.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 11 May 2019
Resolution: Vessel placed new retro.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 10 May 2019 Resolved
Overhead in passenger accommodation space had water intrusion.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 29 April 2020
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 10 May 2019 Resolved
Vessels stern light was inoperable. Permitted to operate day time only until rectified.
Action required: 705 - Other - as specified
Resolved 29 April 2020
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 10 May 2019 Resolved
Vessels steering ram and components were worn and showing signs of corrosion. Must clean and determine condition.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 11 May 2019
Resolution: Vessel cleaned rust and ram and components are still acceptable in terms of use.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 10 May 2019 Resolved
Vessel was missing 2 red flares.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 29 April 2020
02 - Structural Conditions › N/A - No Subsystem › Hull - cracking
Issued 10 May 2019 Resolved
Vessel had minor delamination in hull in the overnight accommodation void.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 29 April 2020
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 10 May 2019 Resolved
Vessels ground was not properly connected to hull in Laz.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 29 April 2020
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 10 May 2019 Resolved
Vessels alcohol strips were expired.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 29 April 2020
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 10 May 2019 Resolved
Vessels engine room hatch is leaking.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 29 April 2020
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 10 May 2019 Resolved
Vessels IBA was improperly fastened.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 May 2019
Resolution: Vessel adjusted painter and hydro.
Lifesaving › Inflatable Liferafts › Hydrostatic Release Unit
Issued 22 May 2017 Resolved
8 person liferaft was found w/ HRU installed upside down, preventing automatic inflation. Corrected on the spot.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 23 May 2017
Resolution: Owner obtained new HRU
Lifesaving › Inflatable Liferafts › Hydrostatic Release Unit
Issued 22 May 2017 Resolved
25 person liferaft was found w/ sea painted disconnected from weak link, and expired HRU.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 May 2017
Resolution: Corrected on the spot. MI gave training on installation of HRUs
Communications › Radio Communications › EPIRB
Issued 22 May 2017 Resolved
EPIRB HRU Expired May2016
Action required: 701 - Prior to carriage of passengers/cargo
Due 22 May 2017
Resolved 23 May 2017
Lifesaving › Inflatable Liferafts › Approval
Issued 22 May 2017 Resolved
25 person liferaft was missing approval nummbers. Provide documentation showing that lifraft is approved.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 25 May 2017
Resolution: Owner provided copies of last inspection and Eagle Enterprise corrected error.
Lifesaving › Lifejacket/PFD (Type IV) › Retroreflective Material
Issued 22 May 2017 Resolved
01 lifejacket was found w/ severely deteriorated retro material. Replace retro as original or replace lifejacket.
Action required: 705 - Other - as specified
Resolved 22 May 2017
Resolution: Vessel purchased new lifejacket. Old lifejacket was destroyed in presence of MI.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 22 May 2017 Resolved
Medicine in first aid kit was expired.
Action required: 705 - Other - as specified
Resolved 25 May 2017
Resolution: Owner purchased new first aid kit.
Engineering › Bilge Water Management System › Valve
Issued 10 May 2016 Resolved
Replace engine room bilge valve.
Action required: 705 - Other - as specified
Due 1 May 2017
Resolved 30 January 2017
Communications › Alarms/Indicators › Bilge Alarm
Issued 10 May 2016 Resolved
Relocate forward bilge alarm. Float is getting stuck under shower piping.
Action required: 705 - Other - as specified
Due 1 May 2017
Resolved 30 January 2017
Engineering › Bilge Water Management System › Pump
Issued 10 May 2016 Resolved
Make repairs to lazarette bilge pump.
Action required: 705 - Other - as specified
Due 1 May 2017
Resolved 30 January 2017
Communications › Alarms/Indicators › Bilge Alarm
Issued 10 May 2016 Resolved
Make repairs to lazarette bilge high level alarm.
Action required: 705 - Other - as specified
Due 1 May 2017
Resolved 30 January 2017
Lifesaving › Lifejacket/PFD (Type I) › Quantity
Issued 10 May 2016 Resolved
Provide correct amount of adult life jackets IAW COI.
Action required: 705 - Other - as specified
Due 1 May 2017
Resolved 30 January 2017
Operations/Management › Pollution › Removal Methods/Procedures
Issued 10 May 2016 Resolved
Provide waste management plan.
Action required: 705 - Other - as specified
Due 1 May 2017
Resolved 30 January 2017
Documentation › Certificates/Documents › FCC SSL
Issued 10 May 2016 Resolved
Provide FCC Ship Radio Station Authorization Certificate. 47CFR80.13
Action required: 705 - Other - as specified
Due 1 May 2017
Resolved 19 May 2017
Documentation › Certificates/Documents › FCC Safety Radiotelephony Certificate
Issued 10 May 2016 Resolved
Provide FCC Safety Radiotelephony Certificate. 47CFR80.903
Action required: 705 - Other - as specified
Due 1 May 2017
Resolved 19 May 2017
Personnel › Certificates/Documents/Licenses › License, Radio Officer
Issued 10 May 2016 Resolved
Provide FCC Marine Radio Operators Permit for Master of vessel. 47CFR80.159
Action required: 705 - Other - as specified
Due 1 May 2017
Resolved 19 May 2017
Operations/Management › Navigation Safety › Carriage of Charts and Publications
Issued 10 May 2016 Resolved
Provide updated navigation pubs to include: Coast Pilot [name withheld], Current Tables, Tide Tables and updated local chart.
Action required: 705 - Other - as specified
Due 1 May 2017
Resolved 30 January 2017
Fire Fighting › Fixed Fire Detection System › Heat Detectors
Issued 19 June 2008 Resolved
engine room heat sensor missing.
Action required: 701 - Prior to carriage of passengers/cargo
Due 19 June 2008
Resolved 19 June 2008
Resolution: replaced engine room heat sensor.
Engineering › Bilge Water Management System › Interface Detector
Issued 19 June 2008 Resolved
bilge high level alarm inop in lazzertt.
Action required: 701 - Prior to carriage of passengers/cargo
Due 19 June 2008
Resolved 19 June 2008
Resolution: replaced battery in alarm circut.
Engineering › Shafting/Propeller Arrangements › Strut
Issued 29 April 2002 Resolved
Replace both electrolysis damaged struts.
Due 30 September 2002
Resolved 10 April 2003
Accommodation/Occupational Safety
Issued 15 May 2001 Resolved
Repair broken hand rail stancion STBD side forward.
Condition: Unknown
Due 15 May 2001
Resolved 15 May 2001
Construction/Loadline
Issued 15 May 2001 Resolved
Replace or repair missing/broken deck stancions in engine room.
Condition: Unknown
Due 15 May 2001
Resolved 15 May 2001
Construction/Loadline
Issued 15 May 2001 Resolved
Re-wire high water alarm in Lazarette to show audio/visual alarm at operators station.
Condition: Unknown
Due 15 May 2001
Resolved 15 May 2001
Construction/Loadline
Issued 15 May 2001 Resolved
Install visual indicator at operators station to show when all bilge pumps are operating. Must show seperately for each pump.
Condition: Unknown
Due 15 May 2001
Resolved 15 May 2001
Engineering
Issued 24 May 2000 Resolved
PROVE PROPER OPERATION ON STBD MDE.
Condition: Unknown
Due 24 May 2000
Resolved 24 May 2000
Electrical
Issued 24 May 2000 Resolved
PROVE PROPER OPERATION OF SSG.
Condition: Unknown
Due 24 May 2000
Resolved 24 May 2000
Electrical
Issued 24 May 2000 Resolved
COMPLETE 110V WIRING INSTALLATION INENGINE SPACE.
Condition: Unknown
Due 24 May 2000
Resolved 24 May 2000
Fire Fighting
Issued 5 April 1999 Resolved
Install a fixed firefighting system. Owner had ordered system but it is not in Homer yet.
Condition: Unknown
Due 5 April 1999
Resolved 5 April 1999
Electrical
Issued 13 April 1998 Resolved
PROVE PROPER OPERATION OF GENERATOR.
Condition: Unknown
Due 4 May 1998
Resolved 21 May 1998
Engineering
Issued 13 April 1998 Resolved
TIGHTEN PACKING ON STARBOARD SHAFT TO SLOW DOWN EXCESSIVE LEAK.
Condition: Unknown
Due 4 May 1998
Resolved 21 May 1998
Lifesaving
Issued 13 April 1998 Resolved
REPLACE 2 REJECTED CHILD PFD'S.
Condition: Unknown
Due 4 May 1998
Resolved 21 May 1998
Accommodation/Occupational Safety
Issued 13 April 1998 Resolved
PROVIDE GARBAGE POLLUTION PLACARD.
Condition: Unknown
Due 4 May 1998
Resolved 21 May 1998
Lifesaving
Issued 9 April 1997 Resolved
PROVIDE RECORD OF MONTHLY EPIRB TESTING.
Condition: Unknown
Due 21 April 1997
Resolved 25 April 1997
Electrical
Issued 9 April 1997 Resolved
PROVIDE LIGHT BULB AND COVER FOR FIXTURE FORWARD STARBOARD SIDE OF LOUNGE OVERHEAD.
Condition: Unknown
Due 21 April 1997
Resolved 25 April 1997
Electrical
Issued 9 April 1997 Resolved
PROVIDE ONE ADDITIONAL PORTABLE EMERGENCY LIGHT.
Condition: Unknown
Due 21 April 1997
Resolved 25 April 1997
Accommodation/Occupational Safety
Issued 9 April 1997 Resolved
PROVIDE COVERED METAL TRASH CONTAINER IN LOUNGE.
Condition: Unknown
Due 6 May 1997
Resolved 8 May 1997
Documentation
Issued 9 April 1997 Resolved
PROVIDE CURRENT CERTIFICATE OF DOCUMENTATION.
Condition: Unknown
Due 22 April 1997
Resolved 25 April 1997
Documentation
Issued 9 April 1997 Resolved
PROVIDE CURRENT FCC STATION LICENSE.
Condition: Unknown
Due 21 April 1997
Resolved 25 April 1997
Navigation
Issued 9 April 1997 Resolved
PROVIDE EMERGENCY BROADCAST PLACARD.
Condition: Unknown
Due 21 April 1997
Resolved 25 April 1997
Lifesaving
Issued 9 April 1997 Resolved
PROVIDE LIFE JACKET DONNING PLACARD.
Condition: Unknown
Due 21 April 1997
Resolved 25 April 1997
Lifesaving
Issued 9 April 1997 Resolved
PROVIDE RECORE OF DRILLS AND TRAINING.
Condition: Unknown
Due 21 April 1997
Resolved 25 April 1997
Construction/Loadline
Issued 9 April 1997 Resolved
PROVIDE LONGER HOSE FOR PORTABLE HAND BILGE PUMP SO EACH COMPARTMENT CAN BEDEWATERED.
Condition: Unknown
Due 21 April 1997
Resolved 25 April 1997
Deck/Cargo
Issued 9 April 1996 Resolved
COMPLETE INTALLATION AND PROVE PROPER OPERATION OF MOORING WINCH.
Condition: Unknown
Due 9 April 1996
Resolved 12 April 1996
Navigation
Issued 9 April 1996 Resolved
PROVE PROPER OPERATION OF SINGLE SIDE BAND RADIO.
Condition: Unknown
Due 9 April 1996
Resolved 12 April 1996
Electrical
Issued 9 April 1996 Resolved
PROVE PROPER OPERATION OF S/S GENERATOR.
Condition: Unknown
Due 9 April 1996
Resolved 12 April 1996
Navigation
Issued 9 April 1996 Resolved
CONDUCT UNDERWAY TESTS TO PROVE PROPER OPERATION OF BMDE'S AND STEERING.
Condition: Unknown
Due 9 April 1996
Resolved 12 April 1996
Lifesaving
Issued 9 April 1996 Resolved
REPLACE ROTTEN LINE ON RING BUOY.
Condition: Unknown
Due 9 April 1996
Resolved 12 April 1996
Lifesaving
Issued 9 April 1996 Resolved
PROVE PROPER OPERATION OF LIGHTS ON SIX ADULT AND FOUR CHILDRENS PFD'S THATDO NOT CURRENTLY WORK.
Condition: Unknown
Due 9 April 1996
Resolved 12 April 1996
Electrical
Issued 9 April 1996 Resolved
PROVIDE ONE ADDITIONAL FLASHLIGHT BY AND PLACE BY ACCESS TO ENGINE ROOM.
Condition: Unknown
Due 9 April 1996
Resolved 12 April 1996
Lifesaving
Issued 9 April 1996 Resolved
MARK IMMERSION SUITS WITH VESSEL OR OWNER'S NAME.
Condition: Unknown
Due 9 April 1996
Resolved 12 April 1996
Engineering
Issued 18 March 1993 Resolved
Repair/replace stbd engine tachometer to the satisfaction of the local OCMI.
Condition: Unknown
Due 1 April 1993
Resolved 8 June 1993
Lifesaving
Issued 18 March 1993 Resolved
Provide 05 additional adult PFDs. Passengers limited to 33 until corrected.
Condition: Unknown
Due 1 April 1993
Resolved 8 June 1993
Electrical
Issued 18 March 1993 Resolved
Repair/replace flourescent light in engine space.
Condition: Unknown
Due 1 April 1993
Resolved 8 June 1993
Construction/Loadline
Issued 5 May 1988 Resolved
PROVIDE APPROVED PLANS OR CALCULATIONS WHICH DEMONSTRATE THE VESSEL'S STRUCTURE MEETS AN ACCEPTABLE DESIGN STANDARD.
Condition: Unknown
Due 5 May 1988
Resolved 5 May 1988

Casualty record · 1

13 July 2005Routine · role: Moored/Anchored in Vicinity of Primary Subject · activity 2444463
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.