MAURY USCG vessel records Sign in
← All vessels

KRITI CHAMPION

KRITI CHAMPION is a 1987 tank ship. The Coast Guard has recorded 38 inspections since 1987, most recently in May 2008, along with 20 deficiencies — 2 with no resolution recorded — and 8 operational controls.

Records from 1987 to 2008. Most recent: operational control imposed, 22 May 2008.

Built
1987
Last inspected
17 May 2008
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

8420270 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
288347
Flag
GREECE
—
Maury page id
psix-288347

Inspections, by type

…with no type recorded21
Years with a record 16 calendar years (1987–2008)
The 38 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 18 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it26874 - Convention (Subpart B), Gross Ton
14904 - Convention (Subpart B), Net Ton
47618 - Dead Weight, Ton
58205 - Displacement, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 38

17 May 2008 Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 3209816
14 February 2008 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3147659
13 February 2008 MARPOL Annex I Examination · PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3146745
23 November 2007 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3103056
7 November 2007 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3088314
5 November 2007 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3093014
27 September 2007 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3067735
14 July 2007 COC-TVE Renew · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2991518
28 July 2006 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 2728413
15 October 2005 Ballast Water Examination · MARPOL Annex I Examination · ISPS III Exam · MARPOL Annex V Examination · COC-TVE Renew
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2515008
15 October 2005 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 2515267
21 January 2005 Random ISPS/MTSA/PSC
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 2279703
19 December 2004 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2268508
5 October 2004 Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 2214546
30 September 2004 Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2209958
4 September 2004 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 2186154
1 September 2004 ISPS II Exam
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 2182999
30 August 2004 COC-TVE Annual
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2180802
27 December 2003 Security Inspection
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 1984324
24 June 2003 Deficiency Check
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1825442
12 June 2003 Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1831447
8 June 2003 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1812139
8 June 2003 Certificate of Compliance
Administrative · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1813786
25 October 1996 Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 396721
14 October 1995 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 384880
9 November 1994 Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 372175
9 November 1994 Tank Vessel Examination · MARPOL Annex I Examination · MARPOL Annex V Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1177955
13 June 1994 Type not recorded
No type recorded · COTP LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 527437
4 March 1994 Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 442568
30 August 1993 MARPOL Annex I Examination · Certificate of Compliance
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1146210
7 April 1992 Certificate of Compliance
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1268496
9 April 1991 Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 343080
7 April 1991 Certificate of Compliance
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 933887
27 June 1990 Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 467042
7 December 1989 Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 334077
7 December 1989 Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1227711
30 April 1988 Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 452056
20 August 1987 Certificate of Compliance
Administrative · MIO HOUSTON · USCG Heartland District (CGD-H) · Activity 1005255

Deficiency record · 20

Navigation › Collision/Grounding Avoidance › Radar
Issued 17 May 2008 No resolution recorded
Vessels Primary Radar System is inoperative. 74 SOLAS V/19.2.7.1 / 33 CFR 164.35(a)
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Engineering › Steam Boiler (auxiliary/waste heat) › Pump
Issued 13 February 2008 Resolved
The main boiler is leaking fuel oil excessively. The vessel is required to repair fuel oil leaks to the satisfaction of the certificate issuing authority.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 16 February 2008
Resolution: See attached Class Report for details.
Engineering › Diesel Engine (propulsion-direct drive) › Injector (fuel injection)
Issued 13 February 2008 Resolved
Main Engine high pressure fuel injectors lines are leaking fuel oil excessively. The vessel is required to make repairs to the satisfaction of certificate issuing authority.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 16 February 2008
Resolution: See attached Class Report for details.
Engineering › Steam Boiler (auxiliary/waste heat) › Piping
Issued 13 February 2008 Resolved
The auxiliary boiler is leaking fuel oil excessively. The vessel is required to repair fuel oil leaks to the satisfaction of certificate issuing authority.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 16 February 2008
Resolution: See attached Class Report for details.
Engineering › Steam Boiler (auxiliary/waste heat) › Feed pipe
Issued 13 February 2008 Resolved
The auxiliary boiler hot water feed tank is leaking steam excessively into the engine room. The vessel is required to make repairs to steam leaking tank to the satisfaction of the certificate issuing authority.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 16 February 2008
Resolution: See attached Class Report for details.
Engineering › Diesel Engine (propulsion/auxiliary-electric) › Nozzle, Injection (fuel injection)
Issued 13 February 2008 Resolved
# 1 & 2 Main generators are leaking fuel from high pressure line to connection with injection nozzle. Vessel shall submit class report from certificate issuing authority.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 16 February 2008
Resolution: See attached Class Report for details.
Stability › Watertight Integrity › General
Issued 13 February 2008 Resolved
The stern water tank near the shaft seal has two pin size holes in the upper stbd. side that were leaking water into the bilge. Vessel shall submit class report from certificate issuing authority.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 16 February 2008
Resolution: See attached Class Report for details.
Engineering › Steam System (auxiliary) › Piping
Issued 13 February 2008 Resolved
Hot water is leaking from the steam pipe near the heavy fuel oil tank for the main engine, the water is leaking near an electrical panel. Vessel shall submit class report from certificate issuing authority.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 16 February 2008
Resolution: See attached Class Report for details.
Engineering › Steam System (auxiliary) › Piping
Issued 13 February 2008 Resolved
A rubber hose is connected to the main boilers hot water tank and to a pipe causing it to leak hot water. Vessel shall submit class report from certificate issuing authority.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 16 February 2008
Resolution: See attached Class Report for details.
Navigation › Collision/Grounding Avoidance › Echo-sounding Device
Issued 13 February 2008 Resolved
The vessels echo depth sounder is inoperable. Vessel is to submit a technician report attesting the complete operation of the echo depth sounder
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 February 2008
Resolution: Item repaired to satisfaction of attending USCG Examiner.
Engineering › Diesel Engine (auxiliary) › Valve
Issued 13 February 2008 Resolved
The emergency generators fuel tank is leaking fuel at the bottom sight glass valve, Vessel shall submit class report from certificate issuing authority.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 16 February 2008
Resolution: See attached Class Report for details.
Navigation › Collision/Grounding Avoidance › Radar
Issued 7 November 2007 Resolved
Vessel requested a deviation from the rules to enter the COTP zone of New Orleans with an inoperative Radar.
Action required: 17 - Rectify deficiencies prior to departure
Due 7 November 2007
Resolved 7 November 2007
Resolution: Received tech report from [name withheld] LTD satisfying requirement.
Engineering › Compressed Air System (control) › Valve
Issued 27 September 2007 No resolution recorded
Vessels regulator valve of the pneumatic main engine control system was leaking.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolution: The leaking regulator was renewed in port.
Engineering › Diesel Engine (propulsion-direct drive) › Cylinder
Issued 4 September 2004 Resolved
VSL SUSTAINED AN ENGINE CASUALTY DURING ITS DEPARTURE FROM PORT APPROXIMATELY 10 NM OFFSHORE OF CAPE HENRY. VSL CONTINUED ON ITS VOYAGE PAST CG JURISDICTION. ISSUED A DEFICIENCY REQUIRING VESSEL TO SUBMIT A CLASS SURVEYORS REPORT ATTESTING TO THE PROPER OPERATION OF THE MAIN ENGINE AND THE REPAIRS TO THE #5 CYLINDER EXHAUST VALVE TO THE SATISFACTION OF CLASS SOCIETY SURVEYOR.
Condition: Unknown
Action required: 15 - Rectify deficiencies by next port
Resolved 17 September 2004
Resolution: Cleared by Class Report
Pollution Prevention/Response › Prevention Equipment › Sewage System Valve
Issued 30 August 2004 Resolved
MSD found lined up for overboard discharge of raw untreated sewerage while within the port of NY. Master given a a written letter of warning for violation of 33CFR159 this date.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 30 August 2004
Resolved 1 September 2004
Fire Fighting › Fixed Fire Detection System › Smoke Detectors
Issued 30 August 2004 Resolved
Engine room smoke detectors inoperative and to be repaired to satisfaction of Lloyds.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 August 2004
Resolved 31 August 2004
Resolution: Done this date
Engineering › Diesel Engine (auxiliary) › Valve
Issued 30 August 2004 Resolved
Emergency fuel oil shutoff valve frozen and inoperative.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 August 2004
Resolved 31 August 2004
Resolution: Done this date
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Cargo Pump
Issued 30 August 2004 Resolved
Gas free certificate for cargo pump room missing. Supply this prior to next US port and prior to commercial operations in US waters.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 August 2004
Resolved 1 September 2004
Navigation › Collision/Grounding Avoidance
Issued 8 June 2003 Resolved
LOD granted for having one of two radars inop. for inbound transit only on June 8, 2003, in Port Everglades, Florida. Vessel shall provide proof of repairs prior to departure or request another LOD. LEGACY COMPONENT DESC: Radar Plotting Facilities
Action required: 17 - Rectify deficiencies prior to departure
Resolved 9 June 2003
Resolution: Received report from technician attesting staisfactory repairs to inop radar.
Construction/Loadline › Markings
Issued 8 June 2003 Resolved
Load line marking not permanently affixed to hull IAW ICLL 73/78 / Annex I / Reg. 8. LEGACY COMPONENT DESC: Load Line Mark
Action required: 705 - Other - as specified
Due 8 July 2003
Resolved 24 June 2003
Resolution: Loadline has been stamped in permanently and Master states the loadline will be welded in permanently at a future date, cleared deficiency.

Ownership record