Records from 2001 to 2017. Most recent: inspection, 16 November 2017.
Inspection history · 38
16 November 2017
Deficiency Check
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 6307963
24 June 2017
ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 6180730
13 October 2016
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6021485
2 August 2016
Type not recorded
No type recorded · Station Alexandria Bay · USCG Great Lakes District (CGD-GL) · Activity 5961489
2 August 2016
Type not recorded
No type recorded · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 5968252
1 August 2016
ISPS II Exam · Enhanced Seaway Inspection (Massena only) · Ballast Water Examination · Joint Vessel Security Verification (Massena only) · PII Safety Exam
Physical examination · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 5959609
7 March 2016
COE-Dockside
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 5826225
3 March 2016
Type not recorded
No type recorded · Sector North Carolina · USCG East District (CGD-E) · Activity 5826464
8 August 2015
Type not recorded
No type recorded · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 5209410
21 July 2015
ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 5191602
27 June 2014
ISPS II Exam · COE-Dockside · Ballast Water Examination · PII Safety Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4901293
3 June 2012
Joint Vessel Security Verification (Massena only) · Administrative Inspection · ISPS II Exam · Ballast Water Examination
Physical examination · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 4327140
7 September 2010
ISPS III Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3839894
17 December 2009
ISPS I Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3652116
15 December 2009
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3648662
11 October 2008
ISPS I Exam
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 3342634
11 October 2008
Type not recorded
No type recorded · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 3342637
9 October 2008
Type not recorded
No type recorded · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 3341490
19 February 2008
Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 3150019
8 December 2007
Type not recorded
No type recorded · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 3112793
28 October 2007
Ballast Water Examination
Physical examination · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 3089611
17 May 2007
Type not recorded
No type recorded · Marine Safety Unit Wilmington · USCG East District (CGD-E) · Activity 2937072
15 January 2007
MARPOL Annex V Examination · Ballast Water Examination · MARPOL Annex I Examination · Random ISPS/MTSA/PSC
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2856001
6 September 2006
Administrative Inspection
Administrative · Marine Safety Unit Duluth · USCG Great Lakes District (CGD-GL) · Activity 2770579
2 September 2006
Ballast Water Examination
Physical examination · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 2763090
1 September 2006
Enhanced Seaway Inspection (Massena only)
Physical examination · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 2770417
5 July 2006
PII Safety Exam · ISPS II Exam
Physical examination · Sector Lake Michigan · USCG Great Lakes District (CGD-GL) · Activity 2701956
1 July 2006
Enhanced Seaway Inspection (Massena only) · Ballast Water Examination
Physical examination · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 2693392
1 July 2006
Joint Vessel Security Verification (Massena only)
Physical examination · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 2693394
8 November 2005
Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2530722
23 April 2004
Administrative Inspection
Administrative · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 2050722
25 August 2003
Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1886930
3 December 2002
Ballast Water Examination · Administrative Inspection
Physical examination · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 1713691
26 September 2002
Ballast Water Examination · Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1680394
28 May 2002
MARPOL Annex I Examination
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1622539
24 May 2002
Administrative Inspection
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1620429
24 April 2002
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1624250
13 September 2001
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 293648
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 24 June 2017
No resolution recorded
1730 - Any ship of 10,000 gross tonnage and above shall be fitted with oil filtering equipment complying with paragraph 7 of this regulation. PSCO noted an entry in the Oil Record Book dated June 16, 2017 that exceeded the maximum throughput of the Oily Water Seperator. MARPOL(2011 C.E. Annex I/14.2 40AC
Condition: Invalid
Action required: 705 - Other - as specified
Due 20 January 2018 — due date passed with no resolution recorded
Navigation › Collision/Grounding Avoidance › Danger Messages
Issued 24 June 2017
Resolved
1699 - A receiver capable of receiving international NAVTEX service broadcasts if the ship is engaged in any area in which an international NAVTEX service is provided. PSCO observed that the NAVTEX print out was not legible. SOLAS2014 CH.IV/Reg.7.4 40AC
Condition: Invalid
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 1 July 2017
Resolved 21 November 2017
Resolution: PSCO's observed legible NAVTEX printout and received Class Report attesting to proper operation/installation of new NAVTEX receiver/printer.
Electrical › Electric Generation Source (emergency) › Power Requirement
Issued 7 September 2010
Resolved
0950-Electric equipment in general- The battery charger for the brigde emergency battery bank is not operating. It was observed by the PSCO that the breaker for the starboard side search light has been tagged out of service. The breaker panel was tied into at the search light breaker to pick up an emergency electrical line to power the GPS and NAVTEX. SOLAS 2009
Action required: 17 - Rectify deficiencies prior to departure
Due 9 September 2010
Resolved 9 September 2010
Resolution: Received, reviewed and accepted Class report from [name withheld] stating all outstanding deficiency has been rectified.
Fire Fighting › Fire Pumps › Casing
Issued 19 February 2008
Resolved
PSCOs found the vessel's emergency fire pump to be inoperable. The Chief Engineer (C/E) stated the emergency fire pump froze/ceased in December 2007, and damaged the casing and drive lantern; therefore rendering the emergency fire pump inoperable. The C/E submitted a requisition order 28DEC07 and the company confirmed purchase of the damaged parts on 28JAN08. As of 19FEB08 the parts were not on
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Resolved 22 February 2008
Resolution: 22 FEB 08: Received class report stating the fire pump casing and drive lantern have been replaced with factory spare parts. The pump has been examined and found to be in good working order.
Documentation › Logs/Records › Oil Record Book
Issued 19 February 2008
Resolved
PSCOs found entries in the Oil Record Book (ORB) for the incinerator to exceed its rated capacity as listed on vessel's IOPP Form A. The IOPP Form A rates the maximum capacity of the incinerator at 20l/h. The operating instruction for the incinerator in the ORB exceed 20l/h. The operating instruction for the incinerator list the maximum capacity for the incinerator at 37.5kg/h for waste oil,
Action required: 17 - Rectify deficiencies prior to departure
Resolved 22 February 2008
Resolution: 22 FEB 08: Attending class surveyor has tested and confirmed the burn rate of waste oil is 37.5kg/h, and solid waste is 20 kg/h.
Engineering › Bilge Water Management System › Piping
Issued 19 February 2008
Resolved
PSCOs observed a flexible hose attached to the bilge suction manifold. C/E stated the hose was used to remove bilge water from areas that does not have fixed piping. Have class address proper piping arrangements for the bilge suction manifold.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 22 February 2008
Resolution: 22 FEB 08: Received class report stating the flex hose has been considered acceptable, and no further action is required.
Engineering › Fuel Oil Service System › Pump
Issued 19 February 2008
Resolved
PSCOs found the thermal oil pump, used for transferring thermal oil from thermal oil storage tank to the thermal oil expansion tank inoperable. Fixed piping was removed & a portable pump & flexible hose was installed to provide a means of transferring thermal oil from the storage tank to the expansion tank. Have class address proper repair & operation of the thermal oil pump.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 22 February 2008
Resolution: 22 FEB 08: Received class report stating the thermal oil pump has been dismantled and restored to normal operating condition. Pump has been tested to undersigned surveyors satisfaction.
Personnel › Certificates/Documents/Licenses
Issued 26 September 2002
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 17 - Rectify deficiencies prior to departure
Due 26 September 2002
Resolved 27 September 2002
Resolution: Received faxed copy of letter of application endorsements..
Documentation › Certificates/Documents
Issued 26 September 2002
Resolved
Have agent fax copy of the following certificates to U.S. Coast Guard: Certificate of Registry, Cargo Ship Safety Certificate, International Load Line, and International Tonnage Certificate. LEGACY COMPONENT DESC: Cargo Ship Safety Certificate
Action required: 705 - Other - as specified
Due 26 September 2002
Resolved 27 September 2002
Pollution Prevention/Response › Prevention Equipment
Issued 28 May 2002
Resolved
Oily water seperator inoperable. Has been inoperable since 15MAR02. Vsl personnel ordered a replacement part which was not the proper part. See activity 1622539 narrative for details. LEGACY COMPONENT DESC: Oily Water Separator (15 ppm)
Action required: 17 - Rectify deficiencies prior to departure
Due 30 May 2002
Resolved 26 September 2002
Resolution: Reviewed class report.