MAKANI OLU

MAKANI OLU is a 1998 school ship. The Coast Guard has recorded 19 inspections since 2016, most recently in July 2026, along with 75 deficiencies — 1 with no resolution recorded — and 2 casualty investigations between 2011 and 2023.

Records from 2011 to 2026. Most recent: inspection, 17 July 2026.

Built
1998
Last inspected
17 July 2026
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Everything above is free. The detail below — the inspection history, the deficiency record, the casualty record and the documentation record — is Professional, $39 a month. Sign in.

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the School Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 17 July 2026
…with no type recorded1
Operational controls None recorded without a removal date
Years with a record 11 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDA6945
Flag
UNITED STATES
Maury page id
psix-28868

Documentation record

Registered dimensions (L × B × D)76.5 ft × 20.0 ft × 9.0 ft
Registered tonnagegross 68 / net 61
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderDENNIS SCHREIBER · ST AUGUSTINE, FL, UNITED STATES · built 1998
Hull materialSteel
PropulsionAuxiliary Sail
Hull shapeSail (Distinct Keel)
Hull configurationMonohull
Hailing portKANEOHE, HI
Trade endorsementsCoastwise, unrestricted, Recreational, Registry
DocumentationValid · issued 4 February 2026 · expires 28 February 2027
Service, as the file records itSchool Ship
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it68 - Simplified, Gross Ton
59 - Displacement, Gross Ton
61 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
Detail on this page

19 inspections, each with its date, unit and type; 75 deficiencies with the resolution recorded against each; 2 casualty investigations, with date and classification; the documentation record: dimensions, tonnage, builder, hailing port, endorsements, dates. The counts in the summary above are the same counts, and they are free.

$39 a month or $299 a year, every vessel page, cancel any time. Founding rate $19.99 a month for life, for the first 200 subscribers. Plans Sign in

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 19

17 July 2026 Administrative Inspection
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 8440909
15 December 2025 Deficiency Check · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 8283942
2 December 2024 Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 8042035
21 December 2023 Deficiency Check · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7839118
7 November 2023 Internal Structural Exam · Drydock Exam · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7800117
26 August 2023 Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7777230
27 September 2022 COI Inspection · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7548443
1 December 2021 Excursion Permit
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7360762
30 September 2021 Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7324350
6 July 2021 Administrative Inspection
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7247607
3 March 2021 Examination of Repairs
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7147793
9 October 2020 Examination of Repairs · Drydock Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7074393
12 August 2020 Annual Inspection · Administrative Inspection · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7031508
8 November 2019 Deficiency Check · In-Service Inspection · Administrative Inspection · Internal Structural Exam · Drydock Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6852445
15 August 2019 Administrative Inspection · Examination of Repairs · Periodic Inspection · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6769080
14 August 2018 DAPI Audit · Annual Inspection · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6511297
12 September 2017 Drydock Exam · Administrative Inspection · Internal Structural Exam · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6265497
21 August 2017 COI Inspection · DAPI Audit · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6248986
10 June 2016 Deficiency Check · Administrative Inspection · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 5902879

Deficiency record · 75

01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 17 July 2026 No resolution recorded
Except as provided for in paragraphs (b) through (e) of this section, each vessel must undergo drydock and internal structural examinations as follows: (1) If your vessel operates in saltwater, it must undergo two drydock examinations and two internal structural examinations within any 5-year period unless it has been approved to undergo an underwater survey (UWILD) under § 169.230 of this part. No more than 3 years may elapse between any two examinations.Vessel lapsed on drydock due date of 31MAY2026. Vessel cannot carry persons in addtion crew until complition of dry dock to the satisfaction of the atttending USCG marine inspector.
Action required: 705 - Other - as specified
07 - Fire Safety › N/A - No Subsystem › Operation of Fire protection systems
Issued 22 December 2025 Resolved
At each inspection for certification, periodic inspection, annual inspection, and at every other vessel inspection all observed unsafe practices and hazardous situations must be corrected. Generator does not shut down with the main engine upon activation of Fireboy system.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 January 2026
Resolution: Tested fireboy, all sat.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 22 December 2025 Resolved
Each vessel of less than 100 gross tons that has accommodation spaces located below the main deck must have permanently installed lighting which is connected to a single emergency power source or permanently installed, relay controlled, battery operated lanterns. The lighting or lanterns must be fitted along the avenues of escape, in the wheelhouse, and in the engine compartment. Emergency lighting was not operational.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 January 2026
Resolution: Emergency lighting was operational.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 22 December 2025 Resolved
Except as otherwise provided in this section, each vessel must carry the following pyrotechnic distress signals: 6 hand red flare distress signals and 6 orange smoke distress signals, OR 12 hand rocket propelled parachute red flare distress signals. 46 CFR 169.553(c)(1)(2)
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 January 2026
Resolution: All flares were onboard.
09 - Working and Living Conditions › 091 - Living Conditions › Lighting (Accommodation)
Issued 22 December 2025 Resolved
All quarters, including washrooms, toilet rooms, and hospital spaces must be adequately lighted. Rack lighting in berthing and engine room light was not operable.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 January 2026
Resolved 28 January 2026
Resolution: Rack lighting was repaired.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 22 December 2025 Resolved
Each fire hydrant must be identified in red letters and figures at least two inches high “FIRE STATION NO. 1,” “2,” “3,” etc. Fire station not marked on fire hydrant near pilothouse. Add identification marking to fire hydrant.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 January 2026
Resolved 21 January 2026
Resolution: Showed proof via photograph showing "FIRE STATION"
09 - Working and Living Conditions › 092 - Working Conditions › Warning notices
Issued 22 December 2025 Resolved
Each escape hatch and other emergency exit must be marked on both sides using at least 1-inch letters: “EMERGENCY EXIT, KEEP CLEAR”, unless the markings are deemed unnecessary by the Officer in Charge, Marine Inspection. No markings on interior sides of egress ladder wells in forward crew and passenger spaces and captain's cabin. Add required markings to ladder wells.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 January 2026
Resolved 28 January 2026
Resolution: Markings were on both sides of ladderwells.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 22 December 2025 Resolved
Each carbon dioxide or clean agent fire extinguishing alarm must be conspicuously marked: “WHEN ALARM SOUNDS VACATE AT ONCE. CARBON DIOXIDE OR CLEAN AGENT BEING RELEASED.” Missing signage in the engine room for alerting crew of alarm and vacating space. Signage must be conspicuously marked in space, ie bulkhead near entrance, back of door, etc.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 January 2026
Resolved 27 January 2026
Resolution: Two new signs were affixed in the engine room.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 22 December 2025 Resolved
Each vessel must meet the applicable requirements in Subchapter S, parts 170-174, of this chapter. 46 CFR 171.125 (b)(2) Watertight integrity above the margin line in a vessel less than 100 gross tons. (b) Each hatch cover must—(2) Be attached to the hatch frame or coaming by hinges, captive chains, or to other devices to prevent its loss. Hatch leash, line or chain was not attached to the vessel to prevent loss.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 January 2026
Resolved 27 January 2026
Resolution: Hatch laynards were attached.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 24 January 2024 Resolved
Fixed carbon dioxide or halogenated extinguishing systems must be installed to protect the enclosed engine room space. Demonstrate proper operation of the installed pre-engineered fixed gas fire extinguishing system (fireboy). Demonstrate shutdown and override abilities and be familiar with testing and operations. 46 CFR 169.564(a)(1)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 30 January 2024
Resolution: Fixed gas extinguishing system was tested satisfactory.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 24 January 2024 Resolved
All vessels must be provided with a satisfactory arrangement for draining any compartment, other than small buoyancy compartments, under all practical conditions. Main cabin bilge alarm is inoperable. 46 CFR 169.650
Action required: 17 - Rectify deficiencies prior to departure
Resolved 30 January 2024
Resolution: Main cabin bilge alarm is operational.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 24 January 2024 Resolved
Repairs or alterations to the hull, machinery, or equipment that affects the safety of the vessel may not be made without the knowledge and approval of the officer in Charge, Marine Inspections. Third party survey report is required. The following areas of concerns must be addressed; a) Foremast goose neck is attached to the bottom threaded area of the turnbuckle causing stress and possibly damaging the turnbuckle threads, b) that same turnbuckle that connects the stay to the forward mast tang has a wasted cotter pin at the connection point, c) mouse or install cotter pins missing on all turnbuckles, shackles and toggles that require this, ensure no meat hooking after install, d)Rustbust or replace turnbuckles for bobstay and whisker stays, e) Gooseneck for the mizzen mast has an undersized bolt and nut installed, ensure proper hardware is in place with locknut. 46 CFR 169.235(a)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 30 January 2024
Resolution: All rigging deficiencies have been corrected. Captain discussed with 3rd party surveyor prior to making repairs.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 24 January 2024 Resolved
One lifebuoy on each side of the vessel must have an attached line at least 15 fathoms in length. Replace worn polypropylene line for stbd side life buoy. 46 CFR 169.549(a)(2)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 30 January 2024
Resolution: Line was replaced.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 24 January 2024 Resolved
Each personal floatation device must have at least 200 sq. cm. of retroreflective material attached on its front side and at least 200 sq. cm. on its back side. Replace worn retro tape for 05 adult PFD's. 46 CFR 169.545(d)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 30 January 2024
Resolution: Retro tape was replaced.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 24 January 2024 Resolved
All connections must be made to battery terminals with permanent type connectors. Spring clips or other temporary type clamps may not be used. Replace wingnut on house battery and replace house battery posts where nuts cannot fully thread on the terminal to hold larger cables. 46 CFR 169.668(e)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 30 January 2024
Resolution: Corrected.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 24 January 2024 Resolved
Wiring, where subject to mechanical damage, must be protected. Remove blue wire nuts near engine room inverter and replace with pressure type connectors if in use; or electrically insulate with tape, or remove, if dead end wires. 46 CFR 169.673(b)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 30 January 2024
Resolution: Corrected.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 24 January 2024 Resolved
The employer shall provide an Employee Assistance Program for all crew member that includes both education and training on the effects and consequences of drug and alcohol use. Employee assistance information and hotline number must be posted for crew members awareness. 46 CFR 16.401
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 30 January 2024
Resolution: EAP information was posted.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 24 January 2024 Resolved
No marine employer shall engage or employ any individual to serve as a crew member unless the individual passes a chemical test for dangerous drugs for that employer. Provide proof pre-employment and random drug testing of crew members has been completed this past year. 46 CFR 16.201(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 30 January 2024
Resolution: Spoke to DER to confirm DAPI requirements.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 27 September 2022 Resolved
Vessels are inspected for compliance with the standards required by this subchapter. Items not covered by standards in this subchapter must be in accordance with good marine practice and acceptable to the Officer in Charge, Marine Inspection. Vessel did not maintain an equipment record, monthly checklist, or replacement schedule within their PMP in accordance with NVIC 02-16. Include items listed in NVIC 02-16 in the vessel's PMP. 46 CFR 169.237
Action required: 17 - Rectify deficiencies prior to departure
Resolved 25 October 2022
Resolution: Vessel rep produced an equipment record, monthly checklist, and replacement schedule within their PMP in accordance with NVIC 02-16.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 27 September 2022 Resolved
The OCMI may require that a vessel and its equipment meet any test or inspection deemed necessary to determine that they are suitable for the service in which they are to be employed. Operator shall schedule a 3rd party rigging survey, to include rigging inspection aloft, and provide the survey report prior to operating. 46 CFR 169.259
Action required: 17 - Rectify deficiencies prior to departure
Resolved 25 October 2022
Resolution: Third party rigging survey conducted satisfactorily.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 27 September 2022 Resolved
Where PFDs are stowed so that they are not readily visible to persons onboard, the containers in which they are stowed must be marked “adult personal flotation devices” or “child personal flotation devices”, as appropriate, and with the number contained therein, in at least 1-inch letters and figures. Stowage containers for PFDs were unmarked. Mark stowage containers. 46 CFR 169.545
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 October 2022
Resolved 25 October 2022
Resolution: Stowage container relabeled.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 27 September 2022 Resolved
Each personal flotation device and ring life buoy must be marked with the vessel’s name. Vessel's name on the stbd ring life buoy is faded. Repair or replace. 46 CFR 169.741
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 October 2022
Resolved 25 October 2022
Resolution: Ring life buoy replaced.
09 - Working and Living Conditions › 092 - Working Conditions › Guards - fencing around dangerous machinery parts
Issued 30 September 2021 Resolved
Each exposed hazard, such as gears or machinery, must be properly protected with covers, guards, or rails. Accessory side of Main engine not protected. 46 CFR 169.331
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 18 October 2021
Resolution: Guard covering the accessory side of the main engine installed.
09 - Working and Living Conditions › 091 - Living Conditions › Electrical devices
Issued 30 September 2021 Resolved
At each inspection for certification, periodic inspection, annual inspection, and at every other vessel inspection all observed unsafe practices and hazardous situations must be corrected. Electrical outlet cover missing and dead-end wires in STBD crew cabin. 46 CFR 169.257
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 18 October 2021
Resolution: Dead-end wires covered and electrical outlet faceplate was installed.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 30 September 2021 Resolved
Unless a splice is made by an insulated pressure wire connector, it must be thoroughly soldered and taped with electrical insulating tape or the soldered joint must be otherwise protected to provide insulation equivalent to that of the conductors joined. Dead-end wires on 50 amp fuse breaker in Engine room. 46 CFR 169.673(d)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 18 October 2021
Resolution: Dead-end wire covered.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 30 September 2021 Resolved
The lighting or lanterns must be fitted along the avenues of escape, in the wheelhouse, and in the engine compartment. Inadequate emergency lighting in cadet cabin. 46 CFR 169.711(c)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 18 October 2021
Resolution: Emergency light provided by the cadet cabin emergency escape.
11 - Life Saving Appliances › N/A - No Subsystem › Stowage and provision of liferafts
Issued 30 September 2021 Resolved
Each lifeboat, inflatable liferaft, and lifefloat must be stowed so that it is capable of being put in the water safely and rapidly even under unfavorable conditions of list and trim. Manual release pelican hooks are seize and corroded on both liferafts. 46 CFR 169.521(a)(1)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 18 October 2021
Resolution: Liferaft hydrostatic release pelican hooks replaced with new stainless steel type pelican hooks.
10 - Safety of Navigation › N/A - No Subsystem › Magnetic compass
Issued 30 September 2021 Resolved
Each vessel must be fitted with a magnetic steering compass. Compass light is extinguished. Vessel restricted to daytime operations only. 46 CFR 169.709(a)
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 18 October 2021
Resolution: Magnetic compass light repaired and proved operational.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 30 September 2021 Resolved
Each bilge suction must be fitted with a suitable strainer having an open area not less than three times the area of the bilge pipe. Suction pick-ups not fitted strainer attachment. 46 CFR 169.652(c)
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 18 October 2021
Resolution: Bilge pump strainers installed.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 30 September 2021 Resolved
All connections must be made to battery terminals with permanent type connectors. Spring clips or other temporary type clamps may not be used. Battery charger connected to E-battery with spring type clips. 46 CFR 169.668(e)
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 18 October 2021
Resolution: Battery charger connections changed to a bolted terminal connector.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 30 September 2021 Resolved
All portable fire extinguishers installed on vessels must be of an approved type. Incorrect securing brackets on fire extinguisher in the Engine room and galley. 46 CFR 169.567(c)
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 18 October 2021
Resolution: Fire extinguisher brackets were provided and installed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 28 May 2021 Resolved
All vessels of 26 feet in length and over must be provided with individual bilge lines and suction for each compartment except that the space forward of the collision bulkhead may be serviced by a sluice valve or portable bilge pump if the arrangement of the vessel is such that ordinary leakage can be removed this way. During operational test, bilge piping system unable to take suction. Repair and demonstrate operation to Marine Inspector. 46CFR169.652
Action required: 17 - Rectify deficiencies prior to departure
Resolved 1 June 2021
Resolution: [name withheld] witnessed satisfactory test of bilge system.
09 - Working and Living Conditions › 092 - Working Conditions › Warning notices
Issued 28 May 2021 Resolved
Each exposed hazard, such as gears or machinery, must be properly protected with covers, guards, or rails. Engine belt covers missing. 46CFR169.331
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 6 July 2021
Resolution: Installed belt cover.
09 - Working and Living Conditions › 091 - Living Conditions › Pipes, wires (insulation)
Issued 12 August 2020 Resolved
Wiring, where subject to mechanical damage, must be protected. Electrical outlet cover and attached wires in Captain's cabin are unsecured and protruding from bulkhead. Secure outlet cover and wiring.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 9 September 2020
Resolution: Repaired outlet cover.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 12 August 2020 Resolved
Repairs or alterations to the hull, machinery, or equipment which affects the safety of the vessel may not be made without the knowledge and approval of the Officer in Charge, Marine Inspection. Holes exist in the bottom of the aft bulkhead of the steering gear compartment. Vessel created temporary repair out of plywood, and did not inform [name withheld] a repair proposal to the satisfaction of attending inspector.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 September 2020
Resolved 14 December 2020
Resolution: Repaired satisfactory.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 12 August 2020 Resolved
The master or person in charge shall ensure that the vessel's firefighting equipment is at all times ready for use and that all firefighting equipment required by the regulations in this subchapter is provided, maintained, and replaced as indicated. Master and crew were not aware of testing or maintenance requirements for the heat detector. Create and adhere to maintenance plan based on manufacturer's instructions.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 9 September 2020
Resolution: Contacted Oahu Fire Protection Agency for guidance and discovered alarm could be tested by heating it up. Conducted test utilizing heat gun and added E/R fire alarm check to monthly checksheet.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 12 August 2020 Resolved
The OCMI may require that a vessel and its equipment meet any test or inspection deemed necessary to determine that they are suitable for the service in which they are to be employed. Vessel identifies monthly examinations of ground level rigging equipment in PMP, however did not have a means to record what was checked, on what date, by whom. Identify monthly maintenance checklist in accordance with NVIC 02-16.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 8 September 2020
Resolution: Vessel provided updated monthly check sheet which included date, item, condition, comments, maintenance, and person completing checks.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 15 August 2019 Resolved
The vessel must have on board a valid FCC Safety Certificate. FCC Safety Certificate found expired.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 September 2019
Resolved 27 September 2019
Resolution: The FCC Radio Certificate was issued by the competent authority.
09 - Working and Living Conditions › 092 - Working Conditions › Structural features (ship)
Issued 15 August 2019 Resolved
The basis for any preventative maintenance plan is a robust examination regime to determine, with some level of confidence, component service life and replacement intervals in order to prevent equipment failures and related marine casualties. The licensed master and licensed mate provided evidence of a preventative maintenance plan that is currently in use but does not provide a level of confidence for preventing equipment failure. USCG inspector discovered that the majority of cotter pins, at deck level, used to secure the u-bolts on the galvanized steel wire fittings for all standing rigging were corroded and easily broken when the crew attempted to remove them. The licensed officers in charge of the maintenance plan noted this equipment as sufficient on the most recent monthly inspection and failed to remove them from service. Most notable were the corroded and fractured cotter pins used as the single prevention point to keep the head stay and bobstay u-bolts from backing out. Remove all wasted/corroded cotter pins from service and replace in kind.
Action required: 17 - Rectify deficiencies prior to departure
Due 15 September 2019
Resolved 30 September 2019
Resolution: All standing rigging cotter pins for U-bolt attachments were renewed in kind at deck level.
09 - Working and Living Conditions › 092 - Working Conditions › Structural features (ship)
Issued 15 August 2019 Resolved
When the Coast Guard requires a third party rigging survey for cause under the authority of 46 CFR 169.259, it is for the purpose of determining that the vessel and its equipment are suitable for the service in which it is employed. Referenced sail plan terminology per MSC approved sail plan dated May 7, 2002. USCG discovered two 5 inch long fractures on the upper and lower base of the fore sail boom. USCG also discovered a corroded turn buckle on the fore mast port side upper shroud. The corrosion deteriorated the original thickness of the turnbuckle by an estimated 20%, weakening the original designed strength of the turnbuckle under tension. The turn buckle corrosion was caused by a stainless steel mousing wire contacting a galvanized steel fitting, creating galvanic corrosion. Fore sail boom must be replaced prior to using in a aux sail capacity and fore mast port side upper shroud must be replaced prior to carrying passengers. The licensed mariners failed to follow the Preventative Maintenance Plan. The rigging aloft cannot be verified by a USCG inspector. Complete a third party rigging survey in the presence of the Coast Guard inspector, to include a rigging survey aloft, prior to carrying passengers. Contact USCG Officer in Charge of Marine Inspections at [phone withheld] to schedule a USCG inspector to be present for the rigging survey.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 September 2019
Resolved 30 September 2019
Resolution: A third party survey was conducted. The Coast Guard was not present for the survey. The operator appealed the CG-835 for a marine inspector to be present for the survey and it was granted.
09 - Working and Living Conditions › 092 - Working Conditions › Structural features (ship)
Issued 15 August 2019 Resolved
Inspector is unable to visually verify condition of main mast step structural support below the main deck at frame 14. Steel base structural plate found corroded with scale at frame 14. Remove surrounding wood and scale for further visual inspection prior to carrying passengers. Provide steel gauge report for main mast structural support plating at frame 14 prior to credit dry dock.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 September 2019
Resolved 26 September 2019
Resolution: The operator removed teh panels surrounding the mast at frame 14. The structural support steel frames visually appeared to be in excellent condition and no further gauging reports are needed at this time.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 15 August 2019 Resolved
Vessels greater than 65 feet but less than 120 feet in length must be installed with bilge piping not less than one and one-half inches. Inspector identified bilge piping in the engine room on the suction side of the bilge pump wrapped in duct tape. The master removed the duct tape and revealed a hole in the piping. Replace the wasted bilge piping in kind.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 September 2019
Resolved 30 September 2019
Resolution: New steel piping was installed and tested for the engine room bilge piping. A 12 inch section of bilge piping was renewed with approved flexible hose. The hose is double clamped on both ends.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 15 August 2019 Resolved
Each bilge suction must be fitted with a suitable strainer. Inspector found the engine room bilge suction installed without a strainer. Install a strainer and remove all sorbent pads from the bilge prior to carrying passengers.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 August 2019
Resolved 30 September 2019
Resolution: The operator purchased and installed a new strainer at the bilge suction in the engine room.
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 15 August 2019 Resolved
All enclosed spaces within a vessel must be properly ventilated and must have a means to close off all vents and ventilators. Port side vent for accommodation space found holed. Vent cap installation is located above the hole. Crop and renew the wasted vent.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 September 2019
Resolved 30 September 2019
Resolution: The exhaust ventilation was cropped and renewed using welding material.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 15 August 2019 Resolved
The sidelights of vessels of 65 feet or more in length shall be fitted with matt black inboard screens. The inboard screens were found to be white. Paint the sidelight inboard screens matt black.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 August 2019
Resolved 26 September 2019
Resolution: The port and starboard side light screens were painted matte black.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 15 August 2019 Resolved
Rails or lifelines must consist of evenly spaced courses. The spacing between courses must not be greater than 12 inches. The opening below the lowest course must not be more than 9 inches. Spacing between courses on all rails aft of the pilot house are greater than 12 inches.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 September 2019
Resolved 26 September 2019
Resolution: New lifelines were installed on all rails aft of the pilot house. Measurements between rail spacing measured 10 inches.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 15 August 2019 Resolved
Engine exhaust systems must be built in accordance with ABYC P-1 standard. Metallic connections shall be flanged, threaded, or welded. Materials for dry exhaust must be from table I of the ABYC P-1 standard. Found generator dry exhaust missing flanged, threaded, or welded connection. Operator placed an unknown putty on piping to secure. It is unknown if putty is rated to temperatures exceeding dry exhaust values provided in ABYC standard. Remove putty and exhaust piping above main deck. Replace exhaust piping with metallic connections that is flanged, threaded, or welded. Use specific materials listed in ABYC P-1 for construction of generator exhaust piping.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 September 2019
Resolved 26 September 2019
Resolution: The putty was removed from the generator dry exhaust piping. It was determined that the putty was not for construction use but was installed to prevent water from downflooding the piping since a smaller pipe exits a larger pipe to deck.
09 - Working and Living Conditions › 092 - Working Conditions › Structural features (ship)
Issued 15 August 2019 Resolved
The head stay is secured to the bow sprit using a u-bolt and cotter pin. The u-bolt is not secured with a locking nut and relies on the cotter pin to prevent the bolt from backing out. Provide a more dependent means to secure the head stay u-bolt and prevent the bolt from backing out.
Action required: 17 - Rectify deficiencies prior to departure
Due 15 September 2019
Resolved 30 September 2019
Resolution: The head stay is now secured with a threaded bolt with nut in the U-bolt and a cotter pin at the end of the threads.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 15 August 2019 Resolved
The minimum number of Ring lifebuoys for a vessel under 100 feet in length is 2. Vessel currently has 03 lifebuoys onboard however 02 are missing plugs that no render them not in compliance with the manufactures specifications. Remove the two lifebuoys without a plug and replace at least one of them ring lifebuoy that meets specifications in 46 CFR 160.050 making sure the vessel as at least one on each side of the vessel with minimum 15 fathoms of attached line.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 August 2019
Resolved 26 September 2019
Resolution: Two new 24" USCG approved ring life buoys were purchased and placed into service.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 15 August 2019 Resolved
Each vessel must provide a personal flotation device of appropriate size for each person carried. The vessel is missing 01 adult size life jacket due to it being in non-serviceable condition. Add an additional adult personal flotation device to match total persons identified on COI.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 September 2019
Resolved 26 September 2019
Resolution: One new CG approved offshore Type I lifejacket was purchased and placed into service.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 15 August 2019 Resolved
Each personal flotation device carried on vessel must have a light approved under subpart 160.012 of 46 CFR. Flotation device lights were found to be missing locking pins, cracked, or not having replaced batteries as per manufacture. Verify all batteries are labeled with insert date and replaced every year for alkaline batteries or every 5 years for lithium ion batteries in accordance with manufacture. Further verify all orange cased flotation lights are not missing locking pin or cracked.
Action required: 17 - Rectify deficiencies prior to departure
Due 15 September 2019
Resolved 26 September 2019
Resolution: All lifejacket lights were replaced with new CG approved lights.
05 - Radio Communications › N/A - No Subsystem › MF Radio installation
Issued 15 August 2019 Resolved
Vessel must comply with the regulations of the Federal Communications Commission (FCC) in Title 47 Code of Federal Regulations. The vessel’s two VHF radios are not programmed with the vessel’s MMSI number found on the FCC ship station license. Program the vessel’s VHF radios with the MMSI number.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 September 2019
Resolved 26 September 2019
Resolution: Two VHF radios were programmed with the vessel's MMSI number.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 15 August 2019 Resolved
Vessel with fixed extinguishing system for propulsion machinery must also have a 40-B:C portable fire extinguisher in the vicinity of the exit to that space. Vessel had on board a 10-B:C portable fire extinguisher in the vicinity of the engine room exit. Replace the 10-B:C with a 40-B:C portable fire extinguisher or provide proof of one on the inside of the space.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 August 2019
Resolved 26 September 2019
Resolution: A 40 B:C portable fire extinguisher was placed into service in the vicinity of the engine room exit.
Construction/Loadline › Hull › Bottom Plating
Issued 14 September 2017 Resolved
Submit plans for approval to renew the following; a) wasted transverse hull plate framing in way of aft accomidation. b) Port side aft hull plating identified as .172 think during ultra-sonic testing conducted on 09/13/2017. Upon approval of repair plans, crop and renew in accordance with NVIC 6-68 to the satisfaction of an attending USCG Marine Inspector prior to receiving credit dry dock.
Condition: Improper/Lack of Maintenance
Due 13 October 2017
Resolved 9 October 2017
Resolution: Hull replaced in accordance with approved plans and witnessed satisfactory final testing
Stability › Unintentional Flooding › General
Issued 14 September 2017 Resolved
Prove proper operation of bilge overboard valve located starboard side engine room.
Condition: Improper/Lack of Maintenance
Due 13 October 2017
Resolved 27 September 2017
Resolution: Valve was replaced in kind and witnessed proper operation.
Sail Rigging › Spars › Tangs
Issued 12 September 2017 Resolved
Conduct and provide 3rd party survey report of vessel's rigging system and components. Survey to include on deck and aloft components. Survey and report to be completed to the satisfaction of an attending marine inspector.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 October 2017
Resolved 8 November 2017
Resolution: 3rd party rigging survey completed by Tradewind Marine Services.
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 12 September 2017 Resolved
Crop and renew wooden decking in way of port side forward crew accomidation space.
Condition: Improper/Lack of Maintenance
Due 13 October 2017
Resolved 9 October 2017
Resolution: Deck area satisfactory renewed in kind.
Accommodation/Occupational Safety › Ventilation › General
Issued 30 August 2017 Resolved
Provide vent covers for all vents on main deck in accordance with 46 CFR 169.315.
Due 14 September 2017
Resolved 14 September 2017
Resolution: Vent covers provided.
Communications › Alarms/Indicators › Bilge Alarm
Issued 30 August 2017 Resolved
Lable high water visual/audible alarms at the operating station.
Due 14 September 2017
Resolved 14 September 2017
Resolution: Bilge high water alarms labled for applicable spaces labled at the operating station.
Stability › Watertight Integrity › General
Issued 30 August 2017 Resolved
Install captive chains for forward and aft watertight hatches.
Due 14 September 2017
Resolved 14 September 2017
Resolution: Captive chains for watertight hatches installed.
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 30 August 2017 Resolved
Renew/replace frayed lifeline on ring lifebuoy in accordance with 46 CFR 169.549.
Due 14 September 2017
Resolved 14 September 2017
Resolution: New buoyant lifeline installed on ring buoy.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 30 August 2017 Resolved
Attach floating waterlight to ring lifebuoy in accordance with 46 CFR 169.549.
Due 14 September 2017
Resolved 14 September 2017
Resolution: Floating waterlight attached to ringbuoy.
Lifesaving › Lifebuoys › Serviceable
Issued 30 August 2017 Resolved
Renew worn ring lifebuoy retro-relective tape in accordance with 46 CFR 169.549.
Due 14 September 2017
Resolved 14 September 2017
Resolution: New retro-reflective tape installed on ring lifebuoy.
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 30 August 2017 Resolved
Mark name of vessel on port lifebuoy.
Action required: 705 - Other - as specified
Due 14 September 2017
Resolved 30 August 2017
Resolution: Corrected on the spot. Name of vessel marked on lifebuoy.
Electrical › Lighting (service) › Lighting Fixture
Issued 30 August 2017 Resolved
Provide lighting fixture covers to exposed lights in forward crew accomidations.
Due 14 September 2017
Resolved 30 August 2017
Resolution: Corrected on the spot. Exposed light fixture covered.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 10 June 2016 Resolved
Provide an all around anchor light 46 CFR 169.691
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 2 September 2016
Resolved 26 January 2017
Accommodation/Occupational Safety › Cooking Systems › LPG System Requirements
Issued 10 June 2016 Resolved
Provide a CO detector in the galley 46 CFR 169.703(c)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 2 September 2016
Resolved 27 September 2016
Fire Fighting › Means of Escape › Escape Route Signs
Issued 10 June 2016 Resolved
Mark aft escape hatch “Emergency exit – keep clear” 46 CFR 169.745
Action required: 705 - Other - as specified
Due 2 September 2016
Resolved 5 December 2016
Resolution: Received photo evidence of hatch marked "emergency exit, keep clear"
Stability › Watertight Integrity › General
Issued 10 June 2016 Resolved
Mark watertight hatches “watertight hatch – close in an emergency" 46 CFR 169.747.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 2 September 2016
Resolved 27 September 2016
Operations/Management › Navigation Safety › Carriage of Charts and Publications
Issued 10 June 2016 Resolved
Provide adequate and up-to-date charts for vessel’s operating area 46 CFR 169.809.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 2 September 2016
Resolved 27 September 2016
Deck/Cargo › Mooring/Anchoring › Brake
Issued 10 June 2016 Resolved
Make repairs to deteriorated/missing brake for the capstan and windlass 46 CFR 169.705
Action required: 705 - Other - as specified
Due 2 September 2016
Resolved 27 September 2016
Fire Fighting › Fixed Gas Fire Extinguishing System › Control Valve
Issued 10 June 2016 Resolved
A pre-engineered fixed fire extinguishing system must automatically shut down all engines that intake air within the protected space. Ensure the newly installed generator is secured upon activation of the installed fire extinguishing system 46 CFR 169.564.
Action required: 701 - Prior to carriage of passengers/cargo
Due 2 September 2016
Resolved 15 June 2016
Fire Fighting › Fire Main › Material
Issued 10 June 2016 Resolved
Provide/install piping material meeting the requirements in Subchapter F in way of the flexible non-metallic hose installed on the fire and bilge system 46 CFR 169.642.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 2 September 2016
Resolved 15 June 2016
Fire Fighting › Fire Pumps › Pistons
Issued 10 June 2016 Resolved
Provide a hand operated fire pump with a 5 gpm capacity and a suction and discharge hose 46 CFR 169.559(d).
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 2 September 2016
Resolved 5 December 2016
Resolution: O/O emailed video of pump operating
Sail Rigging › Running Rigging › Halyards
Issued 10 June 2016 Resolved
Provide a parts list, maintenance plan, copy of last rigging survey, and inspection routine to comply with the USCG guidance for sail rigging and mast inspections NVIC 02-16. Make repairs/replace items that are found worn or broken as discussed.
Action required: 705 - Other - as specified
Due 2 September 2016
Resolved 5 December 2016
Resolution: Comprehensive parts list, maintenance plan and inspection regime emailed. Reviewed plan and meets NVIC 02-16

Casualty record · 2

23 September 2011Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 4156614
26 August 2023Routine · role: Involved in a Marine Casualty · activity 7777230
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.