← All vessels
MARIVIA
MARIVIA is a 2001 freight ship. The Coast Guard has recorded 29 inspections since 2001, most recently in October 2017, along with 17 deficiencies and 6 operational controls.
Records from 2001 to 2017. Most recent: inspection, 16 October 2017.
- Built
- 2001
- Last inspected
- 16 October 2017
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 17 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
9228576 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
ELZC6
28891
Flag
LIBERIA
—
Maury page id
psix-28891
Inspections, by type
…with no type recorded16
Years with a record
7 calendar years (2001–2017)
The 29 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
This record may be incomplete: the most recent inspection recorded for this vessel was 9 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 1980.
Documentation record
Tonnage as PSIX records it23652 - Convention (Subpart B), Gross Ton
10807 - Convention (Subpart B), Net Ton
30369 - Dead Weight, Ton
41412 - Displacement, Ton
10807 - Convention (Subpart B), Net Ton
30369 - Dead Weight, Ton
41412 - Displacement, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 29
16 October 2017
PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6288251
14 October 2017
Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6287418
13 October 2017
Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6287109
10 October 2017
Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6284519
2 August 2016
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 5961250
1 August 2016
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 5959236
30 July 2016
Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 5957875
13 July 2016
NPV Safety Exam · ISPS III Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 5939101
12 July 2016
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 5938493
12 July 2016
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 5940287
11 July 2016
ISPS I Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 5937248
20 June 2016
Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 5913609
18 June 2016
Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 5911183
27 March 2016
Ballast Water Examination · PII Safety Exam · ISPS II Exam · Deficiency Check
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 5841346
17 February 2016
Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 5816462
21 January 2016
Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 5801249
8 January 2016
Deficiency Check
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 5793794
16 December 2015
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 5782645
16 December 2015
NPV Safety Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 5782745
15 December 2015
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 5784077
28 October 2015
Deficiency Check
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 5752979
27 August 2015
PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 5227515
24 May 2006
PII Safety Exam · Ballast Water Examination · MARPOL Annex I Examination · ISPS II Exam · MARPOL Annex V Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2657422
2 February 2003
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1738651
17 December 2002
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1720079
17 December 2002
Ballast Water Examination · Annual Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1720541
29 July 2002
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1654056
21 May 2002
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1618786
4 October 2001
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 294212
Deficiency record · 17
Construction/Loadline › Structures › Door
Issued 16 October 2017
Resolved
Found failure of watertight door on main deck aft passageway #700 door. Heavily corroded. Make repairs in accordance with SOLAS 2004 A-1, Reg. 3-1.
Engineering › Fuel Oil Storage/Transfer System › Tank
Issued 16 October 2017
Resolved
Vessel experienced oil discharge from sludge tanks 16, 19, and 21, where sludge oil discharged through the overfill vents into the engine room. Vessel must offload sludge from tanks 16, 18, 19, 21, and 22 to ensure no further discharges will occur from overfill. SOLAS (2001) II-2/15.2.7.
Lifesaving › Lifeboat Equipment › Food Ration
Issued 16 October 2017
Resolved
Found lifeboat with where food rations were compromised, lacking airtight packagaing. Provide food rations I.A.W SOLAS (2014) III/13.1.4 LSA Code 4.4.8.12
Engineering › Feedwater/Condensate Water System › Pump
Issued 16 October 2017
Resolved
Vessel reported main air compressor, steam boiler feed water pump and #2 fuel oil purifier pump not working. The equipment must be in good working order I.A.W. SOLAS 2004/ II-1/26
Engineering › Freshwater System (jacketwater cooling) › Valve
Issued 28 March 2016
Resolved
1499-The condition of the ship and its equipment shall be mantained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed without danger to the ship or persons on board. The regulating valve for the main engine jacket water system was found leaking excessively. 74SOLAS(01)I/11(a)
Operations/Management › Vessel Safety Management › Maintenance of Ship/Equipment
Issued 28 March 2016
Resolved
0740-The company should establish procedures to ensure that the ship is mantained in conformity with the provisions of the relevant rules and regulations and with any additional requirements which may be established by the company. Due to the above noted deficiencies, an external ISM audit is recommended. 74SOLAS(14)IX/3.1 & ISM Code 2010/10.1
Fire Fighting › Fire Pumps › Arrangement
Issued 27 March 2016
Resolved
2550-Ships shall be provided with independently driven fire pumps at least 2 for cargo ships of 1000 gross tons and upward. The ships number 1 fire pump is inoperable. 74SOLAS(01)II-2/4.3.1.2
Engineering › Fuel Oil Service System › Piping
Issued 27 March 2016
Resolved
See narrative for full description. Text will not fit.
Engineering › Steering Gear System › Rudder Stock
Issued 27 March 2016
Resolved
0936-Hydraulic power-operated steering gear shall be provided with arrangements to maintain the cleanliness of the hydraulic fluid . Approximately a half inch of hydraulic oil was found under steering gear next to rudder stock accumulating on deck. 74SOLAS(01)II-1/29.12
Engineering › Diesel Engine (propulsion-reduction gear) › Injector (fuel injection)
Issued 17 February 2016
Resolved
Vessel experianced low lube oil pressure while transiting outbound. 74SOLAS (14)I/11
Engineering › Diesel Engine (propulsion-direct drive) › Valve
Issued 16 December 2015
Resolved
Sufficient power for going astern shall be provided to secure proper control of the ship in all normal circumstances. During Arrival vessel reported inability of vessel to maneuver astern. Classification Society to attend vessel and provide report.
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 27 August 2015
Resolved
Oil filtering equipment shall be of a design and approved by the administration and be such as will ensure that any oily mixture discharged into the sea after passing through the system has an oil content not exceeding 15ppm. The oil content meter on the oil water separator is inoperable and giving incorrect readings. MARPOL 73/78 Annex I/14.6
Engineering › Diesel Engine (propulsion-direct drive) › Turbocharger
Issued 27 August 2015
Resolved
The machinery and fittings shall be of a design and construction and be so installed and protected as to reduce minimum danger to any person on board due regard paid to moving parts, hot surfaces and other hazards. The insulation on the main engine turbo is missing an approx. 1 ft by 1ft piece. SOLAS 74CONSII-1/26.1
Fire Fighting › Miscellaneous Items › Insulation (Penetration of Oil/Oil Vapors)
Issued 27 August 2015
Resolved
In spaces where penetration of oil products is possible, the surface of insulation shall be impervious to oil or oil vapors. Protective insulation surrounding the piping at the base and of the main engine is saturated with oil creating a potential fire hazard 74SOLAS(01Cons)II-2/18.6
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 27 August 2015
Resolved
Satisfactory means in the form of gurard rails shall be provided for the protection of the crew in getting to and from the machinery spaces. Safety railings surrounding the main engine have been removed in multiple locations creating a hazardous condtion for the crew.
Electrical › Lighting (service) › Lighting Fixture
Issued 27 August 2015
Resolved
The main electric lighting system shall provide illumination throughout those parts used by the crew shall be supplied from the main source of electrical power. Multiple lights in the machinery spaces are not adequately illuminating. 74SOLAS(04Cons)II-1/14.2.1
Engineering › Steam System (auxiliary) › Valve
Issued 27 August 2015
Resolved
Main and auxiliary machinery essential for the propulsion and safety of the ship shall be provided with effective3 means for its operation and control. The auxiliary oil fired boiler's high steam pressure automatic stopping device is inoperable. 74SOLAS(04Cons)II-1/31.1
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.