MAURY USCG vessel records Sign in
← All vessels

LACONIA

LACONIA is a 1987 freight ship. The Coast Guard has recorded 29 inspections since 1987, most recently in May 2012, along with 15 deficiencies and 2 operational controls.

Records from 1987 to 2012. Most recent: inspection, 7 May 2012.

Built
1987
Last inspected
7 May 2012
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

8517578 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
289066
Flag
NORWAY
—
Maury page id
psix-289066

Inspections, by type

…with no type recorded20
Years with a record 19 calendar years (1987–2012)
The 29 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 14 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 1981.

Documentation record

Tonnage as PSIX records it37010 - Convention (Subpart B), Gross Ton
68283 - Dead Weight, Ton
78897 - Displacement, Ton
22442 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 29

7 May 2012 ISPS II Exam · PI Safety Exam · Ballast Water Examination · Deficiency Check
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 4293440
28 February 2012 Type not recorded
No type recorded · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 4251349
28 February 2012 Type not recorded
No type recorded · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 4253159
28 February 2012 Type not recorded
No type recorded · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 4259102
19 August 2011 Deficiency Check
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4114194
28 November 2010 ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3885700
13 May 2008 Deficiency Check
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 3205380
31 January 2008 PII Safety Exam · Ballast Water Examination · MARPOL Annex I Examination · MARPOL Annex V Examination · ISPS II Exam
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 3133953
28 February 2005 PII Safety Exam · ISPS II Exam
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 2294844
30 June 2004 PII Safety Exam · Random ISPS/MTSA/PSC · Ballast Water Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2116723
21 January 2004 Re-Inspection · Annual Inspection · Ballast Water Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1990143
26 March 2002 Ballast Water Examination · Annual Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1598105
2 April 2001 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 288601
13 March 2001 Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 288121
18 March 1999 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 426569
26 March 1998 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 414281
2 February 1997 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 399951
3 April 1996 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 389945
26 August 1995 Type not recorded
No type recorded · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 381934
6 November 1994 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 371801
6 November 1994 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 865303
19 January 1994 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 473915
3 March 1992 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 349176
5 November 1990 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 340115
18 February 1990 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 469428
22 September 1989 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 332731
26 August 1988 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 325247
20 March 1988 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 511044
16 September 1987 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 318524

Deficiency record · 15

Fire Fighting › Remote Fuel Shutoff › General
Issued 30 January 2008 Resolved
No means of securing fuel outside emergency generator room. Solas 74/78 (81 Amended) Reg 15/2.5
Action required: 705 - Other - as specified
Due 1 March 2008
Resolved 13 May 2008
Resolution: 13May08 Conducted a PSC administrative Deficiency Check. Received a class report satisfying the requirement. Cleared 1 deficiency from [Act#3133953, Sector Corpus Christi, 30Jan08]. 0 deficiencies remain outstanding.
Fire Fighting › Firemans Outfit › Protective Clothing
Issued 30 January 2008 Resolved
Fire Jacket cannot be fastened, replace or repair. Solas 74/78 (81 Amended) Reg 17/3. Rectify prior to departure to the satisfaction of the Coast Guard.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 3 February 2008
Resolution: Visually verified that vessel received brand new fire suit to replace wasted one.
Navigation › Piloting/Steering › Gryo Compass Repeater
Issued 30 January 2008 Resolved
Gyro repeater in steering gear room is missing from bracket, there are no other means to supply heading. Solas 74(2004 Cons. Ed) Chapter V Reg 2.5.3.
Condition: Unknown
Action required: 705 - Other - as specified
Due 1 March 2008
Resolved 1 February 2008
Resolution: This deficiency was incorrectly cited, therefore should not be considered a part of the vessel''s history.
Lifesaving › Inflatable Liferafts › Float Free
Issued 28 February 2005 Resolved
Make the two portside liferafts float free where the weak links are currently missing on the portside Viking 16's. SOLAS 74 III/15.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 1 March 2005
Resolution: Received fax verifying that two Hammer hydrostatic releases have been purchased and installed. Installation of entirely new hydrostatic releases was an option that the captain favored over replacing just the weak links.
Documentation › Certificates/Documents › IOPP Certificate
Issued 28 February 2005 Resolved
Update the IOPP certificate to include all sludge tanks in block 3 and to show that vessel has capacity to burn sludge in boiler. MARPOL 73/78 I. To the satisfaction of class prior to next US port after sailing foreign.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 31 January 2008
Resolution: Received class report attesting to the deficiency being rectified.
Documentation › Logs/Records › Oil Record Book
Issued 28 February 2005 Resolved
Commence making entries into the oil record book as per the instructions found in appendix III of Annex I of MARPOL 73/78 where the quantity of contents retained is missing under C-12-2&3 and each operation must be recorded separately.
Action required: 705 - Other - as specified
Due 1 March 2005
Resolved 31 January 2008
Resolution: Received class report attesting to the deficiency being rectified.
Engineering › Bilge Water Management System › Piping
Issued 28 February 2005 Resolved
Update the fire and bilge ballast piping plan to reflect the oily water separating equipment as built. MARPOL 73/78 I To the satisfaction of the US Coast Guard, Prior to next US Port after sailing foreign.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 31 January 2008
Resolution: Recieved class report attesting to the deficiency being rectified.
Engineering › Sea-water System (primary cooling) › Piping
Issued 21 January 2004 Resolved
Multiple soft patches and pin holes were found on the generator salt water cooling supply line on the starboard side lower level of the over head. Received Class Report, a new section of pipe was being fabricated. A Condition of Class was issued to make permanent repairs NLT 22FEBO4.
Action required: 705 - Other - as specified
Due 22 February 2004
Resolved 30 July 2004
Resolution: Verified repaired this date.
Engineering › Fuel Oil Service System
Issued 21 January 2004 Resolved
Number 2 fuel oil service pump has an excessive leak at the pump coupling. Fuel is pooling in the pump's containment. Pump is not the be operated until the leak has been repaired. LEGACY COMPONENT DESC: Pump
Action required: 705 - Other - as specified
Due 28 January 2004
Resolved 23 January 2004
Resolution: Received satisfactory Class Report.
Engineering › Compressed Air System (start air) › Compressor
Issued 21 January 2004 Resolved
Main air compressor salt water cooler has a band patch on the cooler end cap at the inlet. Received Class Report, the patch was removed and the hole was brazed. A Condition of Class was issued to make permanent repair NLT 22MAY2004. LEGACY COMPONENT DESC: salt water cooler
Action required: 705 - Other - as specified
Due 22 May 2004
Resolved 30 June 2004
Resolution: Verified repaired this date.
Engineering › Sea-water System (primary cooling)
Issued 21 January 2004 Resolved
The number one diesel generator salt water inlet piping to the inter cooler has a band patch. LEGACY COMPONENT DESC: diesel generator inlet piping
Action required: 705 - Other - as specified
Due 20 February 2004
Resolved 23 January 2004
Resolution: Received satisfactory class report.
Engineering › Diesel Engine (propulsion-direct drive)
Issued 21 January 2004 Resolved
The main engine number 2 cylinder high pressure fuel piping has a leak. Fuel has seeped through the braided jacketing. Make permanent repairs NLT 25JAN2004. LEGACY COMPONENT DESC: high pressure fuel pipe
Action required: 705 - Other - as specified
Due 25 January 2004
Resolved 23 January 2004
Resolution: Received satisfactory class report.
Lifesaving › Lifeboat Equipment
Issued 21 January 2004 Resolved
Starboard lifeboat engine would not start after numerous attempts over the span of one hour.
Action required: 705 - Other - as specified
Due 21 January 2004
Resolved 23 January 2004
Resolution: Received class report attesting to the repair and satisfactory testing of the boat engine.
Construction/Loadline
Issued 26 March 1998 Resolved
PAINT LOADLINE MARKING IN A CONTRASTING COLOR TO THE REST OF THE HULL._x001C_ _x001C_ ICLL 66
Condition: Unknown
Due 26 March 1998
Resolved 31 March 1998
Documentation
Issued 26 August 1988 Resolved
THE VESSEL FAILED TO RETAIN A COPY OF TE DECLARATION OF INSPECTION ON BOARDFROM MOST RECENT BUNKERING.
Condition: Unknown
Due 26 August 1988
Resolved 26 August 1988

Ownership record