Records from 2016 to 2026. Most recent: inspection, 8 April 2026.
Inspection history · 20
8 April 2026
COI Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 8344939
15 January 2026
Administrative Inspection
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 8296827
19 May 2025
Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 8139206
2 April 2025
Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 8103936
26 March 2025
Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 8100000
10 April 2024
Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7892865
27 March 2024
Drydock Exam · Internal Structural Exam
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7886465
22 March 2023
Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7657757
20 April 2022
Annual Inspection · Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7435288
15 March 2022
In-Service Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7416240
16 March 2021
Administrative Inspection
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7157394
22 February 2021
Drydock Exam · Internal Structural Exam
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7144249
15 January 2021
COI Inspection · Deficiency Check · Administrative Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7125070
17 September 2019
Damage Survey · Administrative Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6814385
14 September 2019
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6828295
10 April 2019
DAPI Audit · Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6673476
11 April 2018
Annual Inspection · DAPI Audit
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6397406
20 February 2018
Internal Structural Exam · Drydock Exam
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6360425
30 March 2017
Annual Inspection · DAPI Audit · Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6138266
31 March 2016
DAPI Audit · COI Inspection · Internal Structural Exam
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 5812067
11 - Life Saving Appliances › N/A - No Subsystem › On board training and instructions
Issued 8 April 2026
Resolved
At each initial and subsequent inspection for certification, the marine inspector may require that an abandon ship or man overboard drill be held under simulated emergency conditions specified by the inspector. The Master onboard the vessel during the inspection did not have a valid MMC and not listed on the drug and alcohol program. Vessel restricted to carrying passengers until emergency drills are conducted and witnessed by the attending Marine Inspector.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 22 April 2026
Resolution: MI verified masters license and endorsement.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 8 April 2026
Resolved
Each life jacket must be marked with Type I retroreflective material approved in 46 CFR 164.018 or other standard specified by the Commandant. The arrangement of the retroreflective material applied after March 11, 1996, must be as specified by IMO Resolution A.658(16) (incorporated by reference; see 46 CFR 175.600). The retroreflective material on 11 of the 30 adult sized lifejackets was found wasted. Vessel restricted to 19 total persons.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 22 April 2026
Resolution: MI verified 30 adult and 3 child lifejackets with proper reflective material.
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 8 April 2026
Resolved
The life float painter must: Have a breaking strength of at least 680 kilograms (1,500 pounds). The life float painter was found deteriorated and unserviceable.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 22 April 2026
Resolution: MI verified new life float installation arrangement.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 8 April 2026
Resolved
The float-free link required by § 180.130(a)(1) must be:
(1) Certified to meet § 160.073 in subchapter Q of this chapter, or other standard specified by the Commandant;
(2) Of proper strength for the size of the life float or buoyant apparatus as indicated on its identification tag; and
(3) Secured to the painter at one end and to the vessel on the other end. The CG approval for the life float weak link could not be verfied because the tag was missing. Additionally the weak link was not properly secured to the vessel. Vessel operations restricted to within 1 mile of shore.
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 22 April 2026
Resolution: MI verified new life float installation.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 8 April 2026
Resolved
Each small battery installation must be located in a well ventilated space and protected from falling objects. Generator starting battery is not in a battery box or terminals were not protected.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 May 2026
Resolved 22 April 2026
Resolution: MI verified battery installation.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 26 March 2025
Resolved
11116 - A vessel on a lakes, bays, and sounds, or rivers route must carry: Three hand orange smoke distress signals. The vessel only had two orange smoke distress signals on board.
46 CFR 180.68(b)(2)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 March 2025
Resolution: Vessel operator purchased new flares.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 26 March 2025
Resolved
11117 - The ring life buoy grab line shall be 3/8-inch diameter polyethylene, polypropylene, or other suitable buoyant type synthetic material having a minimum breaking strength of 1,350 pounds. The grab line disintegrated when touched by the Marine Inspector.
46 CFR 180.70(b)
46 CFR 160.050-3
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 2 April 2025
Resolution: Recieved photo evidence for replaced life bouy
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Other (Conditions of employment)
Issued 26 March 2025
Resolved
18299 - The marine employer must have a sufficient number of alcohol testing devices readily accessible on board the vessel to determine the presence of alcohol in the system of each individual who was directly involved in the SMI. No alcohol testing devices maintained onboard vessel. The vessel did not have any approved alcohol testing devices on board.
46 CFR 185.212
46 CFR 4.06-15
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 28 March 2025
Resolution: Vessel operator purchased new alcohol test swabs.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 26 March 2025
Resolved
11118 - 11118 - An adult life jacket must be provided for each person carried on board a vessel. The vessel was missing 01 adult life jacket. The maximum number of passengers is reduced to 27 until the life jacket is replaced.
46 CFR 180.71(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 28 March 2025
Resolution: Vessel operator provided evidence of a sufficient number of life jackets on board.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 26 March 2025
Resolved
10109 - 10109 - A power-driven vessel underway shall exhibit sidelights. The port sidelight was inoperable.
33 CFR 83.23(a)(iii)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 28 March 2025
Resolution: Received photographic evidence the port light was fixed.
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 26 March 2025
Resolved
11127 - Each item of survival craft equipment must be of good quality, and efficient for the purpose it is intended to serve. Life Float needs re-coating or replaced.
46 CFR 180.175(a)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 March 2025
Resolved 12 May 2025
Resolution: Received photographic evidence the life float was replaced.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 20 April 2022
Resolved
On a vessel of at least 7.9 meters (26 feet) in length, a visual and audible alarm must be provided at the operating station to indicate a high water level in space with a through-hull fitting below the deepest load waterline. Visual indicator for battery space inoperable.
46CFR182.530(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 May 2022
Resolved 26 April 2022
Resolution: visual indicator for high water alarm operable.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 20 April 2022
Resolved
A hatch exposed to the weather must be watertight, except that a hatch on a watertight trunk that extends at least 12 inches above the weather deck may be weathertight. Local OCMI policy ACIDNOTE SPV 99-08 authorizes reduction of engine hatch coaming to 6 inches. Port and starboard hatch coamings were modified to accommodate new exhaust piping, reducing coaming height to 0 inches in way of exhaust piping.
46CFR179.360(a)(1)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 May 2022
Resolved 26 April 2022
Resolution: Engine compartment coamings modified to wrap around new exhaust piping. May require further review at next annual.
11 - Life Saving Appliances › N/A - No Subsystem › Rigid liferafts
Issued 20 April 2022
Resolved
Each battery used in an item of lifesaving equipment, except inflatable survival craft equipment, must be replaced during the annual inspection if the expiration date of the battery has passed. Battery for floating waterlight attached to starboard ring buoy found expired. Passenger operations limited to daylight hours only.
46 CFR 176.808(b)
Action required: 705 - Other - as specified
Resolved 26 April 2022
Resolution: Floatinging waterlights for life float and life ring renewed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 21 April 2021
Resolved
The engine head, block, and exhaust manifold must be water jacketed and cooled by water from a pump that operates whenever the engine is operating. Port engine raw water suction hose chaffed, cracked and weeping thru hose jacket. Repair as original.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 May 2021
Resolved 30 April 2021
Resolution: Received correspondence with vessel rep [name withheld] confirming new raw water suction hose installed.
01 - Certificates & Documentation › 011 - Ships Certificates › USCG Certificate of Documentation (COD)
Issued 16 March 2021
Resolved
Any vessel of at least five net tons which engages in the fisheries on the navigable waters of the United States or in the Exclusive Economic Zone, or coastwise trade, unless exempt under §67.9(c), must have a Certificate of Documentation bearing a valid endorsement appropriate for the activity in which engaged. Vessel's COD is expired.
46CFR67.7
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 April 2021
Resolution: New COD received reflecting new ownership/management.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 22 February 2021
Resolved
The owner or managing operator shall make a vessel available for drydock examinations and internal structural examinations required by this section. O/Op failed to make vessel available for drydock and internal structural examination by the date required on the vessel's Certificate of Inspection.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 March 2021
Resolution: DDX and ISE was conducted.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 15 January 2021
Resolved
Battery Connections must be made to battery cable and battery terminals with permanent type connectors. Battery cable connector to battery cable for starting batteries are corroded and wire between and protective coating is corroded. Repair as original.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 May 2021
Resolved 30 April 2021
Resolution: Received correspondence with vessel rep [name withheld] confirming new battery cable connectors installed.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 15 January 2021
Resolved
Portable fire extinguishers must be located so that they are clearly visible, and readily accessible from the space being protected. Installation and location must be to the satisfaction of the Officer in Charge Marine Inspection (OCMI). Fire extinguisher bracketsdo not have suitable marine type bracket to hold extinguisher properly for underway operation. Provide applicable brackets or secure extinguishers appropriately to satisfaction of OCMI.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 May 2021
Resolved 30 April 2021
Resolution: Received correspondence with vessel rep [name withheld] confirming suitable fire extinguisher mount installed.
Lifesaving › Lifejacket/PFD (General) › Condition
Issued 30 March 2017
Resolved
Replace 01 adult life jacket.
Action required: 705 - Other - as specified
Due 6 April 2017
Resolved 2 April 2017
Resolution: Replaced adult life jacket.
Documentation › Certificates/Documents › FCC SSL
Issued 30 March 2017
Resolved
Obtain copy of FCC Station Authorization Certificate
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 6 April 2017
Resolved 5 April 2017
Resolution: Provided copy of Station Authorization Certificate