MAURY USCG vessel records Sign in
← All vessels

ARCTIC WOLF

ARCTIC WOLF is a 1985 industrial vessel. The Coast Guard has recorded 58 inspections since 1989, most recently in August 2020, along with 134 deficiencies — 3 with no resolution recorded — and 1 operational control.

Records from 1989 to 2020. Most recent: inspection, 13 August 2020.

Built
1985
Last inspected
13 August 2020
Documentation
Expired · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDI2939
289438
Flag
UNITED STATES
367056962, 367481710, 367683310, 367704000 (licence lapsed)
Maury page id
psix-289438

Inspections, by type

…with no type recorded15
…past their stated due date3
Years with a record 24 calendar years (1989–2020)
The 58 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 6 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Miscellaneous Vessel class in Maury's sources begin in 1979.

Documentation record

Registered dimensions (L × B × D)123.4 ft × 38.0 ft × 7.0 ft
Registered tonnagegross 295 / net 254
ITC dimensions (L × B × D)123.4 ft × 38.0 ft × 7.0 ft
ITC tonnagegross 322 / net 96
BuilderALASKA SHIPBLDG INC · PRUDHOE BAY, AK, UNITED STATES · built 1985
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portPRUDHOE BAY, AK
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationExpired · issued 30 June 2004
Service, as the file records itIndustrial Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it295 - Regulatory (Subpart C or D), Gross Ton
322 - Convention (Subpart B), Gross Ton
254 - Regulatory (Subpart C or D), Net Ton
96 - Convention (Subpart B), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDI2939MMSI 367683310 · expired · compulsorily equipped · granted 11 July 2015, cancelled 16 August 2025
WDF7161MMSI 367481710 · expired · compulsorily equipped · granted 10 March 2011, cancelled 15 May 2021
WDC6481MMSI 367056962 · expired · compulsorily equipped · granted 20 July 2005, cancelled 19 September 2015
WTY6407MMSI 367704000 · expired · voluntarily equipped · granted 8 September 1995, cancelled 7 January 2006
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 58

13 August 2020 Administrative Inspection · Drydock Exam · Internal Structural Exam
Physical examination · Detached Duty Office Seward · USCG Arctic District (CGD-A) · Activity 7032374
27 July 2020 Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7036368
13 July 2020 Administrative Inspection
Administrative · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 7012079
3 March 2020 Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 6919371
22 February 2019 COI Inspection · Deficiency Check
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 6632701
11 February 2019 Re-Inspection · Administrative Inspection · Deficiency Check
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 6624837
2 August 2018 Deficiency Check · Administrative Inspection · Annual Inspection
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 6498373
27 March 2018 Deficiency Check · Administrative Inspection
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 6380444
15 February 2018 Deficiency Check
Physical examination · Marine Safety Detachment Homer · USCG Arctic District (CGD-A) · Activity 6358108
15 February 2018 Type not recorded
No type recorded · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 6504065
27 December 2017 Administrative Inspection
Administrative · Navigation Center · Activity 6329317
9 October 2017 Drydock Exam · Internal Structural Exam · Annual Inspection
Physical examination · Marine Safety Detachment Homer · USCG Arctic District (CGD-A) · Activity 6274683
16 June 2016 MTSA Verification · COI Inspection · Deficiency Check
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 5907691
9 October 2015 Deficiency Check
Physical examination · Marine Safety Detachment Homer · USCG Arctic District (CGD-A) · Activity 5738024
16 July 2015 Annual Inspection · MTSA Verification
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 5143457
23 May 2014 Deficiency Check · Periodic Inspection
Physical examination · Marine Safety Detachment Homer · USCG Arctic District (CGD-A) · Activity 4872201
11 January 2010 COI Inspection
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 3660965
28 January 2009 Annual Inspection · MTSA Verification
Physical examination · Marine Safety Detachment Kenai · USCG Arctic District (CGD-A) · Activity 3402350
6 June 2008 Plan Review (Other than "T")
Administrative · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 3242664
17 March 2008 MTSA Verification · Annual Inspection
Physical examination · Marine Safety Detachment Kenai · USCG Arctic District (CGD-A) · Activity 3176476
29 January 2008 Plan Review (Other than "T") · Deficiency Check · Hull Examination · Internal Structural Exam
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 3139327
25 January 2008 Administrative Inspection
Administrative · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 3136602
27 September 2007 In-Service Inspection · Administrative Inspection
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 3077695
20 September 2007 Plan Review (Other than "T") · Administrative Inspection
Administrative · Marine Safety Detachment Kenai · USCG Arctic District (CGD-A) · Activity 3062222
23 March 2007 Administrative Inspection
Administrative · Marine Safety Detachment Kenai · USCG Arctic District (CGD-A) · Activity 2893919
13 March 2007 Type not recorded
No type recorded · Marine Safety Detachment Kenai · USCG Arctic District (CGD-A) · Activity 2887150
7 March 2007 Type not recorded
No type recorded · Marine Safety Detachment Kenai · USCG Arctic District (CGD-A) · Activity 2884257
22 June 2006 Type not recorded
No type recorded · Marine Safety Detachment Kenai · USCG Arctic District (CGD-A) · Activity 2688255
10 May 2006 Administrative Inspection
Administrative · Marine Safety Detachment Kenai · USCG Arctic District (CGD-A) · Activity 2647022
6 May 2006 Type not recorded
No type recorded · Marine Safety Detachment Kenai · USCG Arctic District (CGD-A) · Activity 2644071
28 September 2005 Type not recorded
No type recorded · Marine Safety Detachment Kenai · USCG Arctic District (CGD-A) · Activity 2522858
15 July 2005 Internal Structural Exam · Hull Examination · COI Inspection
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 2427881
18 May 2005 Type not recorded
No type recorded · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 2361801
16 May 2005 Type not recorded
No type recorded · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 2359384
21 April 2005 MTSA Verification · Annual Inspection
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 2343329
19 April 2005 Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2337710
29 January 2004 Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 1996963
23 January 2004 Internal Structural Exam · Annual Inspection · Hull Examination
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1991849
21 March 2003 Re-Inspection
Physical examination · Marine Safety Detachment Kenai · USCG Arctic District (CGD-A) · Activity 1762170
12 March 2003 Administrative Inspection
Administrative · Marine Safety Detachment Kenai · USCG Arctic District (CGD-A) · Activity 1756336
7 August 2002 Type not recorded
No type recorded · Marine Safety Detachment Kenai · USCG Arctic District (CGD-A) · Activity 1682943
15 March 2002 Re-Inspection
Physical examination · Marine Safety Detachment Kenai · USCG Arctic District (CGD-A) · Activity 1612640
22 June 2001 Type not recorded
No type recorded · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 166389
27 February 2001 Hull Examination · COI Inspection
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1376449
4 October 2000 Deficiency Check
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 823970
18 September 2000 Deficiency Check
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1053914
23 March 2000 Re-Inspection
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1413685
25 May 1999 Deficiency Check
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 801790
1 March 1999 COI Inspection · Deficiency Check · Hull Examination
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1372522
3 March 1998 Deficiency Check
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1119651
11 February 1998 Re-Inspection
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1111104
22 October 1997 Type not recorded
No type recorded · Marine Safety Detachment Kenai · USCG Arctic District (CGD-A) · Activity 761425
18 October 1997 Type not recorded
No type recorded · Marine Safety Detachment Kenai · USCG Arctic District (CGD-A) · Activity 25262
18 October 1997 Type not recorded
No type recorded · Marine Safety Detachment Kenai · USCG Arctic District (CGD-A) · Activity 209742
14 February 1997 Initial Certification
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1454413
30 April 1996 Hull Examination
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1385690
29 November 1995 Type not recorded
No type recorded · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1396431
23 August 1989 Type not recorded
No type recorded · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1037462

Deficiency record · 134

01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 3 March 2020 No resolution recorded
Vessel missed required drydocking in October 2019. Vessel is not authorized to operate until such time as all required inspections have been completed. Vessel may not move from Skagway Small Boat Harbor until a transit plan is agreed upon by SEAK OCMI and the receiving OCMI.
Action required: 60 - Rectify deficiencies prior to movement
Due 4 July 2020 — due date passed with no resolution recorded
01 - Certificates & Documentation › 011 - Ships Certificates › Load Lines (including Exemption)
Issued 3 March 2020 No resolution recorded
Vessel's ABS-issued Load Line has expired. Vessel is not authorized to proceed beyond the boundary line until a valid Load Line or Load Line exemption is obtained.
Action required: 705 - Other - as specified
Due 4 July 2020 — due date passed with no resolution recorded
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 22 February 2019 Resolved
Provide audiable alarm in the engine room space. There were visual but not audiable alarms in the ER space 46CFR58.25-25(e)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 February 2019
Resolved 25 February 2019
Resolution: Alarm installed
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 22 February 2019 Resolved
Missing Life rafts
Action required: 17 - Rectify deficiencies prior to departure
Due 1 March 2019
Resolved 25 February 2019
Resolution: Life raft returned to vessel from servicing company
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 11 February 2019 Resolved
Replaced wasted exhaust piping on the Starboard Generator prior to operation to the satisfaction of the CG Inspector attending.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 March 2019
Resolved 22 February 2019
Resolution: Corrected
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 11 February 2019 Resolved
Make repairs to all bilge piping in the engine room and prove proper operation of the system
Action required: 60 - Rectify deficiencies prior to movement
Resolved 15 February 2019
Resolution: Vessel has replaced all wasted piping all tested sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 11 February 2019 Resolved
Connect electric bilge discharge hose to overboard discharge
Action required: 60 - Rectify deficiencies prior to movement
Resolved 15 February 2019
Resolution: vessel has reconnected discharge hose to a overboard discharge.
09 - Working and Living Conditions › 092 - Working Conditions › Guards - fencing around dangerous machinery parts
Issued 11 February 2019 Resolved
Install guards over all rotating machinery for both generators to guard the fan belts.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 March 2019
Resolved 22 February 2019
Resolution: Corrected
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 11 February 2019 Resolved
Remove temp. Repair and make permanent repairs to the portable water fill piping on the port side.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 March 2019
Resolved 22 February 2019
Resolution: Corrected
11 - Life Saving Appliances › N/A - No Subsystem › Stowage and provision of liferafts
Issued 11 February 2019 Resolved
In the event the largest survival craft on either side is lost or rendered unserviceable, there must be the capacity sufficient to accommodate the total number of persons on board. Vessel is reduced to a total of 10 persons on board until larger life rafts are installed
Action required: 705 - Other - as specified
Resolved 25 February 2019
Resolution: Verified inflatable liferafts were onboard
10 - Safety of Navigation › N/A - No Subsystem › Rudder angle indicator
Issued 11 February 2019 Resolved
Rudder angle indicator must be provided in the steering gear compartment independent of the control systems for the steering gear
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 March 2019
Resolved 25 February 2019
Resolution: Verified rudder angle indicator was installed and functioning.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 11 February 2019 Resolved
Each opening in an electrical box or Panel boards not being used for wiring must be closed.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 March 2019
Resolved 22 February 2019
Resolution: Corrected
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 11 February 2019 Resolved
All twist-on type of connectors must be made with in an enclosure and the insulated cap of the connector must be secured to prevent loosing due to vibration
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 March 2019
Resolved 22 February 2019
Resolution: Corrected
08 - Alarms › N/A - No Subsystem › General alarm
Issued 2 August 2018 Resolved
General alarm inaudible in port 2nd Deck bunkroom. Make GA audible in the space.
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Resolved 11 February 2019
Resolution: Verified alarm was audible in the 2nd deck bunkroom.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 2 August 2018 Resolved
2nd means of escape from 2nd deck bunkrooms, port and starboard, obstructed on bridge by office furniture. Remove obstructions and label "Emergency Exit - Do Not Block".
Condition: Placed in Improper Service
Action required: 30 - Ship detained
Due 2 August 2018
Resolved 10 September 2018
Resolution: Obstructions removed and escapes labelled.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 2 August 2018 Resolved
Emergency lighting inoperable/improperly installed in engine room embarkation area. Provide required emergency lighting.
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Resolved 11 February 2019
Resolution: Verified operational emergency lighting installed throughout the vessel to include the engine room.
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 2 August 2018 Resolved
All remote fuel shut-off devices inoperable. Repair and proove proper operation.
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Resolved 11 February 2019
Resolution: Verified proper operation of all remote fuel shut-off devices.
07 - Fire Safety › N/A - No Subsystem › Fire-dampers
Issued 2 August 2018 Resolved
Starboard accommodation ventilation closure holed and others unable to be secured. Provide functional means of securing ventilation to affected spaces.
Action required: 30 - Ship detained
Resolved 11 February 2019
Resolution: Verified all ventilation closures were operable and in good condition.
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 2 August 2018 Resolved
Starboard steering pump inoperable. Repair starboard steering pump.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 10 September 2018
Resolution: Repairs effected and tested sat.
02 - Structural Conditions › N/A - No Subsystem › Closing devices/watertight doors
Issued 2 August 2018 Resolved
Watertight doors/hatches severely wasted and no longer watertight. Restore to watertight condition.
Action required: 30 - Ship detained
Resolved 11 February 2019
Resolution: Verified all main deck watertight doors and hatches were operating properly via chalk tests and visual inspection. Forward watertight doors were completely replaced.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 2 August 2018 Resolved
Cables running from port engine room to port 2nd deck bunkroom not protected by fire-resistant penetrations. Make cable penetrations fire-resistant.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 10 September 2018
Resolution: Fireproof penetrations installed.
11 - Life Saving Appliances › N/A - No Subsystem › Rescue boats
Issued 2 August 2018 Resolved
Rescue boat onboard is not CG-approved. Obtain CG approval or replace with CG-approved boat.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 11 February 2019
Resolution: Vessel will be switched to a Coastwise route and will utilize the work skiff alternative to the rescue boat.
11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for rescue boats
Issued 2 August 2018 Resolved
Launching arrangements for rescue boat is via the main deck crane and not via a CG-approved davit. Outfit rescue boat with CG-approved launching arrangement.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 11 February 2019
Resolution: Vessel will be switched to a Coastwise route and will utilize the work skiff alternative to the rescue boat.
11 - Life Saving Appliances › N/A - No Subsystem › Rescue boat inventory
Issued 2 August 2018 Resolved
Required equipment in rescue boat missing or expired. Provide full compliment of rescce boat equipment.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 10 September 2018
Resolution: Flares, first aid kit, and pump installed.
11 - Life Saving Appliances › N/A - No Subsystem › Embarkation arrangement survival craft
Issued 2 August 2018 Resolved
Embarkation ladder does not reach the water in no list condition. Provide embarkation ladders of sufficient length to reach the water at up to 15-degree opposite list.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 11 February 2019
Resolution: Vessel documented that the updated embarkation station is less than 3m from the water. Embarkation ladder is no longer required.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 2 August 2018 Resolved
No charts onboard for Southeast Alaska. Provide corrected charts for operating area.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 10 September 2018
Resolution: New charts for SE AK and W AK availble onboard.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 2 August 2018 Resolved
Paint locker appears too large for 10-lb extinguisher to provide coverage. Submit volume calculations to justify sizing.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 11 February 2019
Resolution: Former paint locker space redesignated to a standard storage room. Flammable goods may no longer be stored in the forward starboard storage space.
11 - Life Saving Appliances › N/A - No Subsystem › Line-throwing appliance
Issued 2 August 2018 Resolved
Rockets for line-throwing devices expired. Provide non-expired rockets.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 10 September 2018
Resolution: New non-expired rockets provided.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 2 August 2018 Resolved
Numerous ring life buoys are waterlogged. Replace with serviceable life buoys.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 10 September 2018
Resolution: New life buoys provided.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 2 August 2018 Resolved
Aspirin in first aid kit expired. Replace with non-expired aspirin.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 September 2018
Resolved 10 September 2018
Resolution: New first aid kits provided.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 2 August 2018 Resolved
Pilothouse electrical cable penetrations are not weathertight. Make penetrations weathertight.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 September 2018
Resolved 10 September 2018
Resolution: Penetrations sealed.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance and inspections
Issued 2 August 2018 Resolved
Objective evidence indicated that required inspections/maintenance of LSA equipment was not being performed. Provide a suitable plan to ensure required inspections/maintenance is being peformed at mandated intervals.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 September 2018
Resolved 11 February 2019
Resolution: Vessel operators produced a lifesaving inspection checklist to meet requirements in 46 CFR 199.190.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 2 August 2018 Resolved
Relief valves on pressure vessels not marked with set pressure or date of last test. Provide for testing of relief valves and mark appropriately.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 September 2018
Resolved 11 February 2019
Resolution: Verified relief valves were properly marked and tested.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › UMS - Ship
Issued 2 August 2018 Resolved
Vessel's periodic safety test procedures (PSTPs) have not been approved by the Coast Guard Marine Safety Center and do not satisfy the minimum requirements. Submit all required information for engine room automation to MSC.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 September 2018
Resolved 22 February 2019
Resolution: Conducted satisfactory PSTPs
07 - Fire Safety › N/A - No Subsystem › Fire control plan
Issued 2 August 2018 No resolution recorded
Current fire & safety plan does not match the vessel as outfitted. Outfit vessel IAW approved plan or submit a new plan to the OCMI for approval.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 September 2018 — due date passed with no resolution recorded
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 2 August 2018 Resolved
No means of voice communication provided between pilothouse and steering gear local control. Provide means of voice communication.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 11 February 2019
Resolution: Verified the proper operation of voice communications between the pilothouse and steering gear local control.
11 - Life Saving Appliances › N/A - No Subsystem › Rescue boats
Issued 2 August 2018 Resolved
Rescue boat collar under-inflated. Inflate rescue boat collar.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 10 September 2018
Resolution: Sponson inflated.
Engineering › Fuel Oil Service System › Valve
Issued 13 April 2018 Resolved
Repair fuel leak on center fuel filter of port generator
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 April 2018
Resolved 27 April 2018
Resolution: Four valves replaced on fuel filters
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 13 April 2018 Resolved
Correct hailing port on COD to match vessel markings "Prudhoe Bay"
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 May 2018
Resolved 11 February 2019
Resolution: COD and ring buoys updated to Prudhoe Bay.
Operations/Management › Drills/Instruction › Abandon Ship
Issued 15 February 2018 Resolved
Conduct fire, man overboard, and abandon ship drills.
Action required: 705 - Other - as specified
Due 15 April 2018
Resolved 13 April 2018
Resolution: drills sat
Personnel › Certificates/Documents/Licenses › License, Master
Issued 15 February 2018 Resolved
Provide evidence of MMC for crew.
Action required: 705 - Other - as specified
Due 15 April 2018
Resolved 13 April 2018
Resolution: MMDs sat
Electrical › Lighting (emergency) › Battery Operated Lantern
Issued 25 January 2018 Resolved
Conduct operational test of all E-lighting.
Action required: 705 - Other - as specified
Due 16 June 2018
Resolved 20 February 2018
Communications › Alarms/Indicators › Steering Failure Alarm System
Issued 25 January 2018 Resolved
Conduct operational test of steering alarms, verify on the bridge alarm panel.
Action required: 705 - Other - as specified
Due 16 June 2018
Resolved 15 February 2018
Engineering › Steering Gear System › Pump
Issued 25 January 2018 Resolved
Conduct operational test of steering pumps from the bridge.
Action required: 705 - Other - as specified
Due 16 June 2018
Resolved 15 February 2018
Engineering › Steering Gear System › Piping
Issued 25 January 2018 Resolved
Reinstall pipe clamps on hydraulic piping on steering system.
Action required: 705 - Other - as specified
Due 16 June 2018
Resolved 15 February 2018
Fire Fighting › Fire Pumps › Pressure
Issued 25 January 2018 Resolved
Conduct operational test of fire pump.
Action required: 705 - Other - as specified
Due 16 June 2018
Resolved 15 February 2018
Engineering › Bilge Water Management System › Pump
Issued 25 January 2018 Resolved
Conduct operational test of both bilge pumps. (1 electric, 1 PMDE mounted pump)
Action required: 705 - Other - as specified
Due 16 June 2018
Resolved 15 February 2018
Electrical › Lighting (service) › Outlet Box
Issued 25 January 2018 Resolved
Remove temp receptacle on aft portside along stairwell.
Action required: 705 - Other - as specified
Due 16 June 2018
Resolved 15 February 2018
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 25 January 2018 Resolved
Replace all expired items in first aid kits in galley and bridge.
Action required: 705 - Other - as specified
Due 16 June 2018
Resolved 15 February 2018
Documentation › Markings/Placards › Warning Signs
Issued 25 January 2018 Resolved
Remove placard for SART on stbdside.
Action required: 705 - Other - as specified
Due 16 June 2018
Resolved 15 February 2018
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 25 January 2018 Resolved
Replace expired eyewash in head.
Action required: 705 - Other - as specified
Due 16 June 2018
Resolved 15 February 2018
Lifesaving › Lifejacket/PFD (General) › Lights
Issued 25 January 2018 Resolved
Add lights to life jackets on bridge.
Action required: 17 - Rectify deficiencies prior to departure
Due 16 June 2018
Resolved 15 February 2018
Lifesaving › Lifejacket/PFD (General) › Lights
Issued 25 January 2018 Resolved
Replace all batteries in life jackets.
Action required: 17 - Rectify deficiencies prior to departure
Due 16 June 2018
Resolved 15 February 2018
Documentation › Safety Management System › Potential Emergency Situations ID Procedures
Issued 25 January 2018 Resolved
Update station bill in all locations.
Action required: 705 - Other - as specified
Due 16 June 2018
Resolved 15 February 2018
Fire Fighting › Firemans Outfit › Self-Contained Breathing Apparatus
Issued 25 January 2018 Resolved
Conduct annual inspection on SCBA's for oxygen analysis.
Action required: 17 - Rectify deficiencies prior to departure
Due 16 June 2018
Resolved 15 February 2018
Communications › Radio Communications › EPIRB
Issued 25 January 2018 Resolved
Correct registration for EPRIB and mark hydrostatic release.
Action required: 17 - Rectify deficiencies prior to departure
Due 16 June 2018
Resolved 15 February 2018
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 25 January 2018 Resolved
Mark all life buoys with name of Vessel and Homeport.
Action required: 705 - Other - as specified
Due 16 June 2018
Resolved 15 February 2018
Fire Fighting › Means of Escape › Blocked
Issued 25 January 2018 Resolved
Clear blocked emergency escape on stbdside 02 deck and submit plan for cables blocking egress.
Action required: 17 - Rectify deficiencies prior to departure
Due 16 June 2018
Resolved 15 February 2018
Communications › Alarms/Indicators › Fire Alarm
Issued 25 January 2018 Resolved
Conduct operational test of all fire detectors throughout vessel.
Action required: 17 - Rectify deficiencies prior to departure
Due 16 June 2018
Resolved 15 February 2018
Operations/Management › Drills/Instruction › Not Conducted
Issued 16 June 2016 Resolved
Provide crew onboard to conduct emergency drills in presence of CG marine inspector.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 22 July 2016
Resolution: Crew were on board and personnel required IAW COI were certified and verified licensing of required crew. Conducted fire drill on M/E and Abandon ship. Also, conducted man overboard. All sat.
Personnel › Certificates/Documents/Licenses › License, Master
Issued 16 June 2016 Resolved
Provide evidence of valid Officer's licenses.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 22 July 2016
Resolution: Verified crews license for all required IAW COI.
Navigation › Piloting/Steering › Magnetic Compass
Issued 16 June 2016 Resolved
Provide a magnetic compass with illuminated light on bridge
Action required: 17 - Rectify deficiencies prior to departure
Resolved 22 July 2016
Resolution: Verified Magnetic compass was installed properly with light on Nav Bridge.
Lifesaving › Inflatable Buoyant Apparatus › Servicing
Issued 16 June 2016 Resolved
Provide life raft servicing certificate
Action required: 17 - Rectify deficiencies prior to departure
Resolved 22 July 2016
Resolution: Verified Liferafts were serviced by certified facility and reviewed documentation and verified liferafts were installed correctly.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 16 June 2016 Resolved
Connect navigation lights to emergency power
Action required: 17 - Rectify deficiencies prior to departure
Resolved 22 July 2016
Resolution: Verified Nav lights were properly installed to backup power and worked properly with loss of main power.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 16 June 2016 Resolved
Remove expired medicines and provide required contents for first aid kit
Action required: 705 - Other - as specified
Due 16 July 2016
Resolved 22 July 2016
Resolution: Verified vessel had proper medicine and first aid equipment. Vesssel replaced expired kis with approved new kits.
Electrical › Lighting (service) › Lighting Fixture
Issued 16 June 2016 Resolved
Install proper light covers throughout vessel
Action required: 705 - Other - as specified
Due 16 July 2016
Resolved 22 July 2016
Resolution: Verified proper light covers were installed throughout vessel.
Electrical › Lighting (emergency) › Lighting Fixture
Issued 16 June 2016 Resolved
Provide emergency lighting in 01 deck portside stateroom at entrance/exit
Action required: 705 - Other - as specified
Due 16 July 2016
Resolved 22 July 2016
Resolution: Verified e-lighting was properly installed for entrance/exit of 01 stateroom portside.
Fire Fighting › Ventilation Systems › Ventilation Fire Dampers
Issued 16 June 2016 Resolved
Provide cover for paint locker vent
Action required: 705 - Other - as specified
Due 16 July 2016
Resolved 22 July 2016
Resolution: Verified vent cover for paint locker was provided.
Communications › Alarms/Indicators › Engineers' Assistance-needed Alarm
Issued 16 June 2016 Resolved
Prove proper operation of engineer's stateroom alarm
Action required: 705 - Other - as specified
Due 16 July 2016
Resolved 22 July 2016
Resolution: Verifed proper operation of engineer's alarm.
Electrical › Electric Supply System (service) › Cable
Issued 16 June 2016 Resolved
Install J-box for black water tank indicator switch wires in engineroom FWD bulkhead
Action required: 705 - Other - as specified
Due 16 July 2016
Resolved 22 July 2016
Resolution: Verified J-box was installed in black water tank in E/R FWD bulkhead.
Electrical › Electric Supply System (service) › Cable
Issued 16 June 2016 Resolved
Remove temp receptacle box on aft stbdside main deck
Action required: 705 - Other - as specified
Due 16 July 2016
Resolved 22 July 2016
Resolution: Verified removal of temp. receptacle box on stbd main deck.
Documentation › Certificates/Documents › International Load Line Certificate
Issued 16 July 2015 Resolved
Provide a valid Load Line Certificate
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 23 July 2015
Resolved 16 June 2016
Resolution: Provided ILL.
Lifesaving › Rocket Parachute Flares › General
Issued 16 July 2015 Resolved
Provide additional 4 red rocket parachute flares.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 23 July 2015
Resolved 17 July 2015
Resolution: Additional flares provided.
Lifesaving › Launching Appliances › Davit
Issued 16 July 2015 Resolved
Complete annual inspection of rescue boat crane. 46 CFR 199.190(f)(2)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 August 2015
Resolved 9 October 2015
Resolution: Annual inspection for rescue boat crane was conducted.
Documentation › Certificates/Documents › FCC Safety Radiotelephony Certificate
Issued 16 July 2015 Resolved
Provide Radio Telephony Certificate 47CFR 80.903
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 August 2015
Resolved 9 October 2015
Resolution: FCC cert was issued to vessel.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Location
Issued 16 July 2015 Resolved
Install fixed fire fighting for paint locker on deck.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 August 2015
Resolved 9 October 2015
Resolution: Fixed firefighting has been installed for paint locker.
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 16 July 2015 Resolved
Prove proper operation and testing of oily water separator.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 9 November 2015
Resolved 22 June 2016
Resolution: OWS is tagged out and will be removed in the winter of 2016.
Electrical › Electrical Distribution System (service) › Panelboard
Issued 16 July 2015 Resolved
Provide AMP rating for circuit breakers on directory for all panel boards.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 August 2015
Resolved 9 October 2015
Resolution: Amp rating was posted in panel boards.
Engineering › Fuel Oil Service System › Hose
Issued 16 July 2015 Resolved
Prove fuel hoses on machinery equipment is SAE-J1942 approved, or replace with approved hoses 46CFR56.50-25(b)
Condition: Invalid
Action required: 705 - Other - as specified
Due 16 August 2015
Resolved 9 October 2015
Resolution: Hoses were replaced with SAE-J1942 approved hoses.
Communications › Alarms/Indicators › Lube Oil Low Pressure Alarm
Issued 16 July 2015 Resolved
Repair electrical short in machinery alarm panel causing Stbd Gen to light when any other alarm activates.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 August 2015
Resolved 9 October 2015
Resolution: Repair was made.
Electrical › Electrical Distribution System (service) › Wiring
Issued 16 July 2015 Resolved
Remove dead end wires that were connected to old sea water pumps.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 August 2015
Resolved 9 October 2015
Resolution: Wires were removed.
Electrical › Electrical Distribution System (service) › Wiring
Issued 16 July 2015 Resolved
Remove dead end gray wire behind air receiver coming up from pipe in tool room
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 August 2015
Resolved 9 October 2015
Resolution: Wires were removed.
Engineering › Fuel Oil Service System › Tank
Issued 16 July 2015 Resolved
Repair sight glass on Port outboard fuel tank.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 August 2015
Resolved 9 October 2015
Resolution: Site glasses were installed.
Engineering › Fuel Oil Service System › Tank
Issued 16 July 2015 Resolved
Provide guards on sight glasses on the Starboard inboard and outboard fuel tanks.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 August 2015
Resolved 9 October 2015
Resolution: Sight glass was installed.
Electrical › Lighting (emergency) › Lighting Fixture
Issued 16 July 2015 Resolved
Provide adequate emergency lighting from Engine control station to emergency exits.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 9 November 2015
Resolved 16 June 2016
Resolution: Emergency lighting has been installed.
Stability › Watertight Integrity › General
Issued 16 July 2015 Resolved
Install Watertight door indicators in pilothouse (at next drydock).
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 30 November 2017
Resolved 15 February 2018
Engineering › Shafting/Propeller Arrangements › Propeller Shaft
Issued 16 July 2015 Resolved
Install shaft tachometers on bridge (at next drydock).
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 30 November 2017
Resolved 15 February 2018
Electrical › Lighting (service) › Switch
Issued 23 May 2014 Resolved
Replace navigation light indicator panel with one that visually and audibly signals the failure of required navigational lights.
Due 31 December 2014
Resolved 6 January 2015
Resolution: Tested new navigation lights panel on bridge for visual and audible signals. All sat.
Electrical › Lighting (emergency) › Lighting Fixture
Issued 23 May 2014 Resolved
Install emergency lighting in way of launching, recovery and water area where survival craft are located and embarked.
Due 31 December 2014
Resolved 6 January 2015
Resolution: Tested new emergency lighting installed on main deck and bridge wings. All sat.
Lifesaving › Lifebuoys › Stowage
Issued 23 May 2014 Resolved
Provide non-corrosive removable clip on all RLB's.
Due 31 May 2014
Resolved 23 May 2014
Resolution: Corrected on the spot.
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 23 May 2014 Resolved
Stencil name and hailing port on RLB.
Due 31 May 2014
Resolved 23 May 2014
Resolution: Corrected on the spot.
Lifesaving › Rescue Boat › Carriage Requirement
Issued 11 January 2010 Resolved
Provide rescue boat and equipment required by 46 CFR 199.262 that meets 46 CFR 156
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 1 April 2011
Resolution: Rescue boat is not approved under 199.262, but is MED approved. 46CFR Table199.610(c) exempts rescue boats from vessels under 500GT.
Stability › Incline Test › General
Issued 11 January 2010 Resolved
Provide updated stability calculations to Marine Safety Center to correct stability letter iaw 46 CFR 170.110
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Resolved 1 April 2011
Resolution: Approved letter and book on board
Electrical › Electric Generation Source (service) › Generator
Issued 17 March 2008 Resolved
SSDG ALARMS INOP, RELAY NEEDED REPLACED.
Condition: Unknown
Action required: 705 - Other - as specified
Due 31 May 2008
Resolved 5 May 2008
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 17 March 2008 Resolved
NEW RETRO TAPE ON LIFE RINGS
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 May 2008
Resolved 5 May 2008
Operations/Management › Drills/Instruction › Not Conducted
Issued 17 March 2008 Resolved
CONDUCT EMERGENCY DRILLS
Condition: Unknown
Action required: 705 - Other - as specified
Due 31 May 2008
Resolved 5 May 2008
Documentation › Certificates/Documents › International Load Line Certificate
Issued 25 January 2008 Resolved
Provide evidence of Annual Loadline Survey. Vessel restricted from voyages beyond the Boundary Line until corrected.
Due 25 January 2008
Resolved 26 January 2008
Documentation › Certificates/Documents › Certificate of Inspection
Issued 25 January 2008 Resolved
Vessel missed 2nd Annual or Periodic inspection. Vessel restricted from commercial operations until corrected.
Due 25 January 2008
Resolved 5 May 2008
Pollution Prevention/Response › Prevention Equipment › Sewage System Piping
Issued 27 September 2007 Resolved
Make proper piping arrangements from portable temporary quarters black water system to the vessel's marine sanitation system.
Action required: 705 - Other - as specified
Due 30 November 2007
Resolved 6 March 2008
Resolution: A branch line is connected to a deck fitting to meet with the protable quarters.
Electrical › Lighting (emergency) › Lighting Fixture
Issued 15 March 2002 Resolved
PROVE PROPER OPERATION OF ALL EMERGENCY LIGHTS THROUGHOUT VESSEL.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Due 20 March 2002
Resolved 19 March 2002
Resolution: ALL LIGHTS OPERATIONAL
Lifesaving › Inflatable Liferafts
Issued 15 March 2002 Resolved
RE-INSTALL LIFERAFTS WHEN SERVICING IS COMPLETE. PROVIDE COPY OF SERVICING CERTIFICATES.
Action required: 17 - Rectify deficiencies prior to departure
Due 20 March 2002
Resolved 19 March 2002
Engineering › Bilge Water Management System › Pump
Issued 15 March 2002 Resolved
REPLACE WORN BELT ON PORT MAIN BILGE PUMP AND PROVE PROPR OPERATION WHEN COMPLETE.
Action required: 17 - Rectify deficiencies prior to departure
Due 20 March 2002
Resolved 19 March 2002
Resolution: BELT REPLACED AND TESTED SAT.
Electrical
Issued 1 March 1999 Resolved
Provide protection from generator exhaust piping in stbd fidley iaw 46CFR56.50-1(k)
Condition: Unknown
Due 24 March 1999
Resolved 29 March 1999
Construction/Loadline
Issued 1 March 1999 Resolved
Adjust both watertight doors in machinery spaces iaw 46CFR91.25-25
Condition: Unknown
Due 24 March 1999
Resolved 29 March 1999
Engineering
Issued 1 March 1999 Resolved
Prove proper operation of stbd main engine overspeed device. 46CFR58.05-1
Condition: Unknown
Due 24 March 1999
Resolved 29 March 1999
Lifesaving
Issued 1 March 1999 Resolved
Conduct underway drills with full crew compliment iaw 46CFR199.180
Condition: Unknown
Due 1 March 1999
Resolved 1 March 1999
Documentation
Issued 1 March 1999 Resolved
Provide Periodic Test Procedures iaw NVIC 1-78 CH 1 and 46 CFR 61.40-10 tocognizant OCMI per ANCMS OCMI ltr dated 28FEB97 for approval. If unable to provide, carry Chief Engineer iaw 46 CFR 15.820
Condition: Unknown
Due 1 March 1999
Resolved 1 March 1999
Electrical
Issued 1 March 1999 Resolved
Remove improperly installed electrical plugs and wires from stbd deck paneliaw 46CFR111.60
Condition: Unknown
Due 24 March 1999
Resolved 29 March 1999
Deck/Cargo
Issued 1 March 1999 Resolved
Replace flexible hoses to rescue boat boom with lengths not to exceed 30 inches iaw 46CFR56.60-25(b)(4)
Condition: Unknown
Due 1 March 1999
Resolved 1 March 1999
Accommodation/Occupational Safety
Issued 1 March 1999 Resolved
Provide labels to all emergency escapes on both sides of fitting
Condition: Unknown
Due 24 March 1999
Resolved 29 March 1999
Engineering
Issued 1 March 1999 Resolved
Provide loss of lubricating oil shutdown alarms to main propulsion_x001C_ machinery iaw 46CFR58.05-10.
Condition: Unknown
Due 24 March 1999
Resolved 29 March 1999
Accommodation/Occupational Safety
Issued 11 February 1998 Resolved
Prove proper operation of Type II marine sanitation device.
Condition: Unknown
Due 11 February 1998
Resolved 11 February 1998
Engineering
Issued 11 February 1998 Resolved
Cap off valves on fuel oil tanks where gauge is missing.
Condition: Unknown
Due 11 February 1998
Resolved 11 February 1998
Navigation
Issued 11 February 1998 Resolved
Prove proper operation of restricted maneuvering light.
Condition: Unknown
Due 11 February 1998
Resolved 11 February 1998
Construction/Loadline
Issued 11 February 1998 Resolved
Adjust dogs on watertight door forward of engine room.
Condition: Unknown
Due 11 February 1998
Resolved 12 February 1998
Accommodation/Occupational Safety
Issued 11 February 1998 Resolved
Label engine room emergency exits.
Condition: Unknown
Due 11 February 1998
Resolved 11 February 1998
Accommodation/Occupational Safety
Issued 11 February 1998 Resolved
Label instructions on how to operate emergency escape hatch from engine room due to unique design.
Condition: Unknown
Due 11 February 1998
Resolved 11 February 1998
Lifesaving
Issued 14 February 1997 Resolved
PROVIDE 2 ADDITIONAL IMMERSION SUITS AND ADULT PFD'S. PERSONS IN ADDITION TO CREW REDUCED TO 14 WITH TOTAL PERSONS ALLOWED BEING 20 UNTIL THIS DEF CLEARED. PERSONS IN ADDITION TO CREW FURTHER REDUCED TO 13 UNTIL CG-835 #1CLEARED. THIS DEFICIENCY NEEDS TO BE CLEARED BY USCG MARINE INSPECTOR.
Condition: Unknown
Due 14 February 1997
Resolved 14 February 1997
Engineering
Issued 14 February 1997 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 14 February 1997
Resolved 14 February 1997
Construction/Loadline
Issued 30 April 1996 Resolved
PROPERLY REPAIR THE SKEGS PORT AND STARBOARD, AS MARKED, TO THE SATISFACTION OF THE ATTENDING MARINE ISNEPCTOR.
Condition: Unknown
Due 24 February 1997
Resolved 24 February 1997
Construction/Loadline
Issued 30 April 1996 Resolved
MAKE ALL COMPARTMENTS AVAILABLE FOR INSPECTION BY A MARINE INSPECTOR. ENSURE THAT ALL COMPARTMENTS ARE CONSTRUCTED IN ACCORDANCE WITH THE APPROVED PLANS.
Condition: Unknown
Due 30 April 1996
Resolved 30 April 1996
Construction/Loadline
Issued 30 April 1996 Resolved
CROP AND RENEW THE BULKHEAD, AS MARKED, BETWEEN THE SHOP AND THE POTABLE WATER TANK COMPARTMENT (FRAME 13), TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR.
Condition: Unknown
Due 30 April 1996
Resolved 30 April 1996
Navigation
Issued 30 April 1996 Resolved
MAKE PERMANENT REPAIRS TO THE STEERING GEAR TO THE SATISFACTION OF THE ATTEDNING MARINE INSPECTOR.
Condition: Unknown
Due 30 April 1996
Resolved 30 April 1996
Construction/Loadline
Issued 30 April 1996 Resolved
PROPERLY WELD THE SPOOL PIECE FOR THE VENT LINES ON THE AFT AND FWD/STBD SEA CHESTS IN ACCORDANCE WITH ABS STANDARDS.
Condition: Unknown
Due 24 February 1997
Resolved 24 February 1997
Construction/Loadline
Issued 30 April 1996 Resolved
PROPERLY WELD THE COVER ON THE FWD/PORT SEA CHEST IN ACCORDANCE WITH ABS STANDARDS.
Condition: Unknown
Due 24 February 1997
Resolved 24 February 1997
Construction/Loadline
Issued 30 April 1996 Resolved
OPEN ALL SEA VALVES AND OVERBOARD VALVES FOR INSPECITO BY A MARINE INSPECTOR.
Condition: Unknown
Due 24 February 1997
Resolved 24 February 1997
Navigation
Issued 30 April 1996 Resolved
MODIFY STEERING GEAR TO MEET APPROVED PLANS, OR SUBMIT AS BUILT DRAWINGS FOR APPROVAL TO THE MARINE SAFETY CENTER VIA MARINE SAFETY OFFICE ANCHORAGE.
Condition: Unknown
Due 30 April 1996
Resolved 30 April 1996
Construction/Loadline
Issued 30 April 1996 Resolved
PROPERLY REPAIR THE CENTER SHAFT TUBE, AS MARKED, TO THE SATISFACTION OF THE ATTEDNING MARINE INSPECTOR.
Condition: Unknown
Due 24 February 1997
Resolved 24 February 1997
Construction/Loadline
Issued 30 April 1996 Resolved
CROP AND RENEW THE BOTTOM PLATE, WHERE IT IS FRACTURED OUTBOARD OF THE STARBOARD SKEG, TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR.
Condition: Unknown
Due 24 February 1997
Resolved 24 February 1997
Engineering
Issued 30 April 1996 Resolved
PROVIDE THE WEARDOWN READINGS, AND THE READING TAKEN AS THE SHAFTS WERE TURNED TO THE ATTEDNING MARINE INSPECTOR.
Condition: Unknown
Due 24 February 1997
Resolved 24 February 1997
Engineering
Issued 30 April 1996 Resolved
DRAW THE STARBOARD AND CENTER SHAFTS AND MAKE AVAILABEL FOR INSPECTION AND TESTING IN ACCORDANCE WITH TITLE 46 CFR 61.20-18.
Condition: Unknown
Due 24 February 1997
Resolved 24 February 1997
Construction/Loadline
Issued 30 April 1996 Resolved
PROPERLY WELD THE FORWARD PORTION OF THE HULL, AS MARKED, TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR.
Condition: Unknown
Due 24 February 1997
Resolved 24 February 1997
Engineering
Issued 30 April 1996 Resolved
CONDUCT NON-DESTRUCTIVE TESTING OF ALL PROPELLERS WITH A MRINE INSPECTOR PRESENT.
Condition: Unknown
Due 24 February 1997
Resolved 24 February 1997
Documentation
Issued 29 November 1995 Resolved
Vessel was operated beyond the boundary line without an assigned load line;issued Coastwise Load Line Certificate to allow operations for 7 days.
Condition: Unknown
Due 29 November 1995
Resolved 29 November 1995

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.