MAURY USCG vessel records Sign in
← All vessels

MANTA RAY

MANTA RAY is a 1987 industrial vessel. The Coast Guard has recorded 188 inspections since 1987, most recently in October 2025, along with 177 deficiencies, 3 operational controls and 14 casualty investigations between 2003 and 2023.

Records from 1987 to 2025. Most recent: inspection, 26 October 2025.

Built
1987
Last inspected
26 October 2025
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

8516079 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
J8B6754
289661
Flag
NIGERIA
303390000
Maury page id
psix-289661

Inspections, by type

…with no type recorded49
Years with a record 37 calendar years (1987–2025)
The 188 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Miscellaneous Vessel class in Maury's sources begin in 1979.

Documentation record

Tonnage as PSIX records it2727 - Regulatory (Subpart C or D), Gross Ton
3104 - Convention (Subpart B), Gross Ton
2224 - Regulatory (Subpart C or D), Net Ton
931 - Convention (Subpart B), Net Ton
5057 - Dead Weight, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

WBV3250MMSI 303390000 · active · compulsorily equipped · granted 12 June 2018, expires 23 June 2028 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspected as a tow unit · 1

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest. Towing vessels are barely present in the record before 1992, so tow-unit membership for activities older than that is recorded only partially.

KAREN ELIANNA Commercial Fishing Vessel · MISLE 107342 · 9 December 1991 · activity 178740

Inspection history · 188

26 October 2025 PSC A
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 8257090
5 March 2024 Administrative Inspection
Administrative · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7874389
30 January 2024 Administrative Inspection
Administrative · Sector North Carolina · USCG East District (CGD-E) · Activity 7857856
18 December 2023 Damage Survey · Deficiency Check · Permit to Proceed
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7840209
25 November 2023 Administrative Inspection · Damage Survey
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7829311
25 November 2023 Type not recorded
No type recorded · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7829942
12 November 2023 Damage Survey
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7823378
9 November 2023 Damage Survey
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 7822678
26 September 2023 Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7798706
26 July 2023 Deficiency Check
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 7752697
14 June 2023 Administrative Inspection · Plan Review (Other than "T")
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 7714807
20 May 2023 Administrative Inspection · Permit to Proceed
Administrative · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 7692764
8 March 2023 Examination of Repairs · In-Service Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7647547
8 March 2023 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 7659238
5 March 2023 Examination of Repairs
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7645719
14 February 2023 Examination of Repairs · Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7636779
6 February 2023 Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 7633029
3 February 2023 Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 7631477
2 February 2023 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 7633954
20 January 2023 Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7624770
18 January 2023 Type not recorded
No type recorded · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 7632650
22 August 2022 Examination of Repairs · Drydock Exam · Deficiency Check · COI Inspection · Administrative Inspection · Internal Structural Exam
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 7540285
31 March 2022 Damage Survey · Examination of Repairs · Administrative Inspection
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 7421938
26 February 2022 Damage Survey
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7402381
8 February 2022 Damage Survey
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 7392432
3 January 2022 Examination of Repairs
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 7374808
27 June 2021 Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7256920
27 June 2021 Damage Survey · Deficiency Check
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 7272879
16 April 2021 Drydock Exam
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 7176747
14 April 2021 Deficiency Check · Damage Survey · Annual Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 7180166
4 February 2021 Damage Survey
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7136028
3 February 2021 Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 7136042
20 January 2021 MARPOL Annex I Examination · Deficiency Check · Periodic Inspection · Damage Survey
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7128407
16 January 2021 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 7125552
4 January 2021 Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 7119279
9 July 2020 Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7005581
5 May 2020 Drydock Exam · Administrative Inspection · Examination of Repairs · Deficiency Check · Hull Examination · Internal Structural Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6949774
24 April 2020 Type not recorded
No type recorded · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6943704
9 April 2020 Deficiency Check
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 6937349
11 February 2020 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6906950
13 January 2020 Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6888809
14 November 2019 MTSA Verification · Deficiency Check · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6854528
19 September 2019 Deficiency Check
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 6815942
8 August 2019 Examination of Repairs
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6774297
17 December 2018 In-Service Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6599409
9 December 2018 Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6595845
29 November 2018 Deficiency Check · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6583493
27 August 2018 Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6524661
17 May 2018 Administrative Inspection · Deficiency Check
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6416601
10 May 2018 Damage Survey
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6416066
5 February 2018 Damage Survey · Administrative Inspection · Examination of Repairs
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 6349762
5 December 2017 Type not recorded
No type recorded · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 6322132
9 November 2017 Damage Survey
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6304374
2 November 2017 Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6330149
5 July 2017 Drydock Exam · Hull Examination · MARPOL Annex I Examination · Internal Structural Exam · Construction Oversight
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6198848
15 September 2016 Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6001903
3 August 2015 MARPOL Annex I Examination · Drydock Exam · Hull Examination · Internal Structural Exam · Inclining Experiment · Annual Inspection · Administrative Inspection · Construction Oversight · Examination of Repairs
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 5205262
9 October 2014 Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 5004562
2 October 2014 Annual Inspection · Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 4997476
30 May 2012 COI Inspection · MARPOL Annex I Examination
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 4328651
29 January 2012 Type not recorded
No type recorded · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 4234616
15 July 2011 Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 4085702
3 December 2010 Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3906849
24 September 2010 Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3859767
26 November 2008 Deficiency Check · Plan Review (Other than "T")
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3369983
13 November 2008 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3362178
14 October 2008 Deficiency Check
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3340319
2 October 2008 Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3332241
18 September 2008 Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3326226
29 May 2007 Administrative Inspection · Annual Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 2944839
14 August 2006 Internal Structural Exam · COI Inspection · Hull Examination
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2747254
30 October 2005 Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2546722
27 September 2005 Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2502115
16 January 2005 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 2277828
29 November 2004 Deficiency Check · Administrative Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 2249850
28 September 2004 Periodic Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 2207175
14 September 2004 Hull Examination · Internal Structural Exam · Deficiency Check
Physical examination · MIDET EAST BANK DETAIL · USCG Heartland District (CGD-H) · Activity 2133994
20 May 2004 Deficiency Check
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 2072816
12 April 2004 Administrative Inspection
Administrative · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 2042764
20 February 2004 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 2010175
18 February 2004 Security Plan Review - VSP
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 2008352
17 February 2004 Administrative Inspection
Administrative · Marine Safety Center (MSC) · Activity 2007882
13 February 2004 Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 2006231
3 January 2004 Examination of Repairs
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 1976647
31 December 2003 Type not recorded
No type recorded · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1976810
19 December 2003 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1967231
1 October 2003 Damage Survey
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1918562
22 September 2003 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1911849
3 September 2003 Annual Inspection · Deficiency Check
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1894949
15 April 2003 Deficiency Check
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1777748
6 February 2003 Examination of Repairs
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1740708
1 February 2003 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1739691
31 January 2003 Damage Survey
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1739784
29 January 2003 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1737844
20 September 2002 Administrative Inspection
Administrative · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1678171
5 July 2002 Annual Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1641499
31 August 2001 Deficiency Check
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1422128
30 August 2001 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 129844
6 July 2001 Hull Examination
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1397711
6 July 2001 COI Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1472639
7 August 2000 Re-Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1427879
3 August 2000 Damage Survey
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1452698
31 July 2000 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 70080
23 November 1999 Deficiency Check
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 810320
4 November 1999 Deficiency Check
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 800092
13 September 1999 Deficiency Check
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 783421
13 July 1999 COI Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1102337
3 July 1999 Type not recorded
No type recorded · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 445654
30 June 1999 Hull Examination
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1429187
24 May 1999 Hull Examination
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1095413
30 November 1998 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 121406
4 November 1998 Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 804883
29 October 1998 Deficiency Check
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 803159
10 September 1998 Re-Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1372354
23 December 1997 Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 282
29 August 1997 Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 773887
16 July 1997 Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 773886
15 July 1997 COI Inspection · MARPOL Annex V Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 774014
25 March 1997 Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 91393
10 March 1997 Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 181171
10 March 1997 Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1470694
27 January 1997 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 57629
3 September 1996 Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 938886
29 August 1996 Hull Examination · Deficiency Check · Re-Inspection · MARPOL Annex V Examination
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1355950
16 March 1996 Deficiency Check
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 884628
16 January 1996 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 184566
21 December 1995 Hull Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1404058
23 October 1995 Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 873561
20 July 1995 COI Inspection · MARPOL Annex V Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1192124
2 August 1994 Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 868758
6 July 1994 Re-Inspection · MARPOL Annex V Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1180650
30 March 1994 Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 673436
21 March 1994 Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 142734
9 October 1993 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 15806
27 July 1993 COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1447258
12 May 1993 Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1444712
18 March 1993 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 106571
14 March 1993 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 117157
18 February 1993 Administrative
Administrative · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1146377
25 January 1993 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 91192
16 December 1992 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 830174
12 August 1992 Deficiency Check
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1134155
20 July 1992 Deficiency Check
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1260773
25 June 1992 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 657408
24 June 1992 Re-Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 954607
2 June 1992 Deficiency Check
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 943351
14 April 1992 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 642857
30 March 1992 Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1263985
9 December 1991 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 178740
3 December 1991 Deficiency Check
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1255353
25 November 1991 Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1249694
18 September 1991 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 652102
24 August 1991 Hull Examination · COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 935908
12 August 1991 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 657407
9 August 1991 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 652101
25 October 1990 Administrative
Administrative · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 912091
29 August 1990 Deficiency Check
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1228295
13 August 1990 Re-Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 913844
31 January 1990 Deficiency Check
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 920318
6 December 1989 Deficiency Check
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1222752
8 September 1989 Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 891911
16 August 1989 Administrative
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1352545
18 July 1989 COI Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1351729
2 May 1989 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1209427
2 May 1989 Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1338172
2 March 1989 Drydock Extension · Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 889415
10 February 1989 Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1035367
17 January 1989 Deficiency Check
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1202843
29 December 1988 Deficiency Check
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1344708
4 November 1988 Deficiency Check
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 892373
2 November 1988 Re-Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1202796
11 October 1988 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1195106
23 September 1988 Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1352116
18 August 1988 Administrative
Administrative · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 889137
12 August 1988 Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1343930
12 July 1988 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1345065
29 April 1988 Deficiency Check
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1199749
21 April 1988 Deficiency Check
Physical examination · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 1039662
11 April 1988 Deficiency Check
Physical examination · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 993668
11 March 1988 Deficiency Check
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 992667
11 February 1988 Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1333562
5 February 1988 Deficiency Check
Physical examination · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 1018117
4 January 1988 Deficiency Check
Physical examination · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 1007688
6 August 1987 Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1029402
30 July 1987 Damage Survey
Physical examination · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 1337390
20 July 1987 Hull Examination · Initial Certification · Initial Construction-Excluding Oversight
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1021464
20 July 1987 Initial Construction-Excluding Oversight · Hull Examination · Initial Certification
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1337894
7 June 1987 Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1198471

Deficiency record · 177

02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 12 November 2023 Resolved
In general, compliance with the standards established by the American Bureau of Shipping, see subpart 90.35 of this subchapter, will be considered as satisfactory evidence of the structural efficiency of the vessel. This vessel has an unidentified leak causing the STBD void 5 to fill with water and potential dredge slurry. Vessel to make permanent repairs IAW ABS Steel Vessel Rules maintaining originally approved scantlings. 835V will be lifted upon satisfactory review by attending Class Surveyor and Marine Inspector.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 17 November 2023
Resolution: 835V lifted and transferred to a previous 835v.
01 - Certificates & Documentation › 013 - Documents › Stability Information Booklet
Issued 14 June 2023 Resolved
During an inspection on 15 March 2023 (act #7647547) it was discovered that there is a cradle to store a work boat on top of the Z-Drive spaces. It was uncertain, when asked, if this arrangement was included in calculations during the last stability test (Stability letter dated 09 November 2015). The plan “Foundation for Crew-boat on Aft Propulsion House” A 6065-2291-1 is dated 27 June 1986. The Fire & Safety Plan 0918-832-001 21 July 2015 shows a boat located on the starboard side main deck between frames 78-81, but nothing on top of the Z-Drive spaces. This was brought to the attention of the local ABS Survey who found that it was not included. As calculations must account for the weight of all loads carried aboard the vessel and being there is no proof that the location of the work boat can be verified, the work-boat may not be carried until a new stability test is conducted and the results allow for the carriage of the work-boat.
Action required: 705 - Other - as specified
Resolved 26 September 2023
Resolution: Work-boat may not be carried until a new stability test is conducted and the results allow for the carriage of the work-boat
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 20 May 2023 Resolved
All marine engineering details, such as main and auxiliary machinery, shall be designed, constructed, and installed iaw this subchapter. Port propulsion motor is inoperable. 705 a/c (prior to commercial operations) 46CFR50.01-10
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Resolved 31 July 2023
Resolution: Port motor and cooler replaced and tested sat
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 15 March 2023 Resolved
Fire hose shall be connected to the outlets at all times. Throughout the ship fire hoses have been disconnect from the hydrants/outlets. Prior to departure connect all fire hoses.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 17 March 2023
Resolution: MI Verified that all fire stations had fire hoses connected to their outlets.
11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for survival craft
Issued 15 March 2023 Resolved
A device must be provided that automatically cut off the power before to avoid over-stressing the falls or davits. Install limit switches for both the port rescue boat davit and the starboard davit launched raft, or provide proof of a installed system.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 24 April 2023
Resolution: Received copy of davit diagram and confirmation from manufacture that the limit switch is installed inside the gear box.
07 - Fire Safety › N/A - No Subsystem › Operation of Fire protection systems
Issued 15 March 2023 Resolved
Provided instructions for the operation of the CO2 systems in a conspicuous location.
Action required: 10 - Deficiency Rectified
Resolved 15 March 2023
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 15 March 2023 Resolved
The vessel’s firefighting equipment shall be ready for use and that all times connect the CO2 bottle for the flammable locker forward port side foc’sle deck IWO frame 20 approximate.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 17 March 2023
Resolution: MI verified that CO2 Bottle discharge hose has been permanently affixed to the Port forward flammable locker on the forecastle deck and is ready for operation.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 15 March 2023 Resolved
In the pump room bilge, starboard side outboard,IWO fire pump remove the blue 5 gallon jug (unknown use) as bilges in the machinery spaces shall not have items which might create a fire hazard.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 17 March 2023
Resolution: MI verified that the bucket found in the bilge has been removed.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 15 March 2023 Resolved
The ship has newly installed grating provide proof that the grating meets the guidance as set out in NVIC 9-97. The label may be molded into the grating, or included on a permanently attached label.
Action required: 705 - Other - as specified
Due 10 July 2023
Resolved 26 July 2023
Resolution: FRP Gratin replaced and cert uploaded; see activity 7752697
07 - Fire Safety › N/A - No Subsystem › International shore-connection
Issued 15 March 2023 Resolved
Properly install the international shore connections to the fire main with suitable connections for shore side fire fighters (stop valve should be before the flange)
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 17 April 2023
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 15 March 2023 Resolved
Fire hazards shall be keep to a minimum, remove all the gear/stores from the AC Space as it is not designed a store room (a sign is also posted "No storage")
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 17 April 2023
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 15 March 2023 Resolved
Each panel board must meet section 17.1 of IEEE 45-2002. Equipment for interior locations not requiring exceptional degrees of protection must be manufactured to at least NEMA 250 Type 1 with drip shield or IEC 60529 IP 11 as specified in IEC 60529. Each transformer winding must be resistant to moisture, sea atmosphere, and oil vapor, unless special precautions are taken, such as enclosing the winding in an enclosure with a high degree of ingress protection. 220/120V Breaker Panel and 440V Transformer in the Starboard Stern Store Room was observed to have severe water damage/corrosion, and the 440V transformer was not secured to the deck. Renew panel, wiring and inspect the internals of the transformer and secure it to the deck. Pictures of repairs can be accepted.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 24 April 2023
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Procedure for inspection, reporting and correcting unsafe conditions and for investigating a
Issued 15 March 2023 Resolved
On January 18, 2023, the vessel was underway off the coast of Cape Hatteras in the Atlantic Ocean when the vessel experienced a loss of electrical power. Provide proof of notification to ABS.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 21 March 2023
03 - Water/Weathertight Conditions › N/A - No Subsystem › Railing, gangway, walkway and means for safe passage
Issued 15 March 2023 Resolved
Suitable hand rails shall be installed above the starboard side Z-drive room provide safety rails to protect the crew when there is need to close the vent covers.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 17 April 2023
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 15 March 2023 Resolved
Drawing #0918-832-01 Fire/Safety Plan dated 7/21/2015 shows what to appears to be a crew boat on the main deck port side 78-81 QTRS 01 Deck. Presently the crew boat is stored across the Z-Drive Rooms. Provide documentation of the installation of the crew boat cradles and storage to this new location. Provide proof of this alteration as no or alterations shall be made without the knowledge OCMI.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 21 March 2023
Resolution: Forwarded to ABS
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 15 March 2023 Resolved
Vessels port fire pump automatic valves (discharge and suction side) are not operating as designed and installed preventing immediate use, must trouble shoot and repair as necessary to bring back into service
Action required: 60 - Rectify deficiencies prior to movement
Resolved 17 March 2023
Resolution: MI verified that the Port Side fire pump is operational and both discharge and suction valves were operating properly.
02 - Structural Conditions › N/A - No Subsystem › Decks - corrosion
Issued 5 March 2023 Resolved
A survey, either general or partial according to the circumstances, shall be made every time an accident; a defect is discovered which effect the safety of the vessel or the efficacy;...or whenever any important repairs or renewals are made. The survey shall be such to ensure that the necessary repairs or renewals have been effectively made, that the material and the workmanship of such repairs or renewals are in all respects satisfactory and that the vessel complies with in all respects with the regulations in this subchapter. Vessel's crew discovered water ingress through a hole in the overhead of the storage room starboard side aft compartment just below the main deck. Owner/operator to submit documentation attesting to temporary repairs and repair proposal for longterm repairs necessary to ensure renewal of the corrosion in the suspect plate within the next 7 days.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 12 March 2023
Resolved 15 March 2023
02 - Structural Conditions › N/A - No Subsystem › Decks - corrosion
Issued 5 March 2023 Resolved
A survey, either general or partial according to the circumstances, shall be made every time an accident; a defect is discovered which effect the safety of the vessel or the efficacy;...or whenever any important repairs or renewals are made. The survey shall be such to ensure that the necessary repairs or renewals have been effectively made, that the material and the workmanship of such repairs or renewals are in all respects satisfactory and that the vessel complies with in all respects with the regulations in this subchapter. Vessel's crew discovered water ingress through a hole in the overhead of the storage room starboard side aft compartment just below the main deck. Owner/operator to repair to like new condition as stated in repair proposal submitted dated March 08, 2023 with-in 30 days.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 13 April 2023
Resolution: Insert checks done (fit up, back gouge, final weld insp) with CGMI and ABS, all sat.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 22 August 2022 Resolved
Wire must be in an enclosure. Wire must be component insulated. Wire other than in switch boards must meet the requirements in sections 24.6.7 and 24.8 of IEEE 45-2002 or equivalent standard. The vessel has various electrical wires not properly secure, and with exposed electrical conductors.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 6 February 2023
Resolved 10 January 2023
Resolution: Vessel made repair to the lighting fixtures, and electrical runs that were unsat.
09 - Working and Living Conditions › 092 - Working Conditions › Safe means of access
Issued 22 August 2022 Resolved
There shall be be at least two means of escape from all general areas where the crew is normally employed. Vessel has 4 emergency hatches that are not functional.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 6 February 2023
Resolved 10 January 2023
Resolution: Vessel correct the hatches and made them operational by addusting the springs.
14 - Pollution Prevention › 141 - MARPOL Annex I › Oil discharge monitoring and control system
Issued 22 August 2022 Resolved
The ship has in operation oily water separating equipment, a bilge monitor, bilge alarm, or combination thereof as required by 155 subpart B of this chapter to meet the control of oil discharges. The ship has in operation oily water separating equipment, a bilge monitor, bilge alarm, or combination thereof as required by 155 subpart B of this chapter to meet the control of oil discharges. OWS devices are not currently operating as required by MEPC .107(49). The sample line to the bilge alarm did not provide a truly representative sample of the effluent with adequate pressure and flow. Additionally,ship staff not familiar with operation of retrieving recorded information. Provide tech report of proper operation, and data retrieval capability.
Condition: Placed in Improper Service
Action required: 17 - Rectify deficiencies prior to departure
Due 6 February 2023
Resolved 10 January 2023
Resolution: The vessel crew determined the reason for the sample line not working properly, and then demonstrated how to operated and retrieve data from the oil content meter.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 22 August 2022 Resolved
Nonmetallic expansion joints must be examined externally at watch inspection for certification and periodic inspection for signs of excessive wear,fatigue, deterioration and physical damage. Vessel had a non metallic expansion joint that need to be replaced for physical damage. Vessel shall not use the dredge system until expansion joint is repaired.
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 February 2023
Resolved 20 January 2023
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 22 August 2022 Resolved
The following emergency lighting and power loads must be arranged so that they can energize: Lighting for passageway, stair, and escape trunks in passenger quarters, crew quarters, public spaces, machinery spaces sufficient to allow passengers and crew to find their way to open decks. Vessel has two engine spaces that need emergency lighting. Vessel added lighting, but needs to prove that it can last for 18 hours in accordance with 46 CFR 112.05-5 (Old J.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 February 2023
Resolved 2 February 2023
Resolution: [withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
11 - Life Saving Appliances › N/A - No Subsystem › Rescue boats
Issued 22 August 2022 Resolved
Each cargo vessel must carry at least one rescue boast. Each rescue boat must be approved under approval series 160.156 Rescue boast had a silicone repair and needs to be repaired by a CG approved 3rd party facility.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 9 February 2023
Resolved 10 January 2023
Resolution: Vessel replaced the rescue boat with a recuse boat from another vessel. The replacement rescue boat has the same deminsions and specifications.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 31 March 2022 Resolved
46 CFR 91.45-1: No repairs or alterations affecting the safety of the vessel with regard to the hull, machinery, or equipment shall be made without the knowledge of the Officer in Charge, Marine Inspections. Vessel has crack in lube oil tank top/deck extending 24" transversely and into generator area.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 12 April 2022
Resolution: Repairs conducted satisfactory to ABS and USCG.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 8 February 2021 Resolved
46 CFR 91.45-5: Vessel is permitted to get underway from Norfolk, VA on or about 8 February 2021 and transit to Port Everglades, FL to complete dredging operations. The dredging operation will last approximately 15-20 days upon arrival to the area. The #5 port void must be inspected by ABS surveyor every 30 days to ensure the temporary patch is free of water. The inspection must continue until permanent repairs are completed. Once dredging operations have concluded, the vessel must proceed to Bollinger Shipyard located in Morgan City, LA to complete permanent repair of #5 port void by NLT 15 April 2021. You must contact MSU Morgan City when vessel arrives in area. **Immediate contact with Sector VA is required with any change of condition.**
Action required: 705 - Other - as specified
Due 15 April 2021
Resolved 2 June 2021
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 4 February 2021 Resolved
46CFR91.45-5:Provide permanent or temporary repair proposal for breach in hopper at #5 port void.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 6 February 2021
Resolution: Vessel completed repair of #5 port void to the satisfaction of ABS surveyor.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 20 January 2021 Resolved
46 CFR 92.01-10 - Crew member was needle gunning and created a hole above the waterline allowing flooding into space to occur.
Condition: Damaged By Earlier Event
Action required: 60 - Rectify deficiencies prior to movement
Resolved 20 January 2021
08 - Alarms › N/A - No Subsystem › General alarm
Issued 20 January 2021 Resolved
Each vessel must have a general emergency alarm system. Demonstrate the operation of the general alarm system prior to departure. Alarm system not working.
Action required: 17 - Rectify deficiencies prior to departure
Due 21 January 2021
Resolved 20 January 2021
Resolution: This was verbally cleared ([name withheld])
10 - Safety of Navigation › N/A - No Subsystem › Pilot ladders and hoist/pilot transfer arrangements
Issued 20 January 2021 Resolved
Pilot boarding areas must have adequate lighting. None of the pilot embarkation areas have lighting. Provide adequate lighting. Being the location of embarkation area is in way of dredging operations a portable light may be used.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 February 2021
Resolved 27 January 2021
Resolution: Received proof that that a portable light had been provided
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 20 January 2021 Resolved
During vessel's annual inspection it was discovered that the the vessel has no PSTP which are required by regulation. Vessel must submit to Marine Safety Center (MSC) for approval DVT/PSTP that meet all relevant parts of applicable regulations. 24Feb2021 submitted to MSC.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 February 2021
Resolved 19 April 2021
Resolution: Vessel has PSTP reviewed and just need to be conducted prior to final approval. Vessel is in DD in LA so test will be conducted by local unit.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 20 January 2021 Resolved
Temp pipe patch found on evaporator supply in port lower engine room. Make permanent and proper repairs.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 February 2021
Resolved 1 March 2021
Resolution: Pipe was replaced with new and all temp soft patches have been removed.
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Electrical
Issued 20 January 2021 Resolved
A total of 3 grounds were found and need to be address (2) on e-gen 120V (1) on 480
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 February 2021
Resolved 1 March 2021
Resolution: Vessel submitted video and email statements to clear this item.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 4 January 2021 Resolved
The RN Weeks is in Sector New York's fleet of responsibility and records indicated that the vessel is PAST DUE for the 3rd Annual/Periodic inspection (LAPSED(3rd inspection sub activity was not opened between 06/05/2020 and 12/05/2020.) Vessels must undergo a periodic inspection within 3 months before or after the second or third anniversary of the date of your vessel’s Certificate of Inspection. You must provide a date and location that the periodic will take place. Once a date is confirmed there will be no extensions made the inspection must take place by 22 January 2021
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 January 2021
Resolved 20 January 2021
Resolution: Completed Periodic Inspection
11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for survival craft
Issued 12 June 2020 Resolved
Vessels life raft launching appliance falls were last replaced in 06JUN15. Vessel is required to replace falls and conduct a weight test in the presence of a marine inspector.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 July 2020
Resolved 13 July 2020
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 12 June 2020 Resolved
Vessel was replacing one of the generators that broke on the vessels last voyage. Vessel was unable to finish the install prior to departure. Vessel is reguired to finish the install within 14 days and notify the nearest OCMI for inspection.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 June 2020
Resolved 16 June 2020
Resolution: Generator was repaired and tested in the presence of an ABS inspector.
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Hospital accommodation (Sickbay)
Issued 14 November 2019 Resolved
The hospital is being used as a accommodation space. The space in addition to normal hospital equipment has additional lockers, workstation, TV and the bed is being used. The hospital is to be used as a treatment space for the sick and no others.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 December 2019
Resolved 9 April 2020
Resolution: Attended by ABS Surveyor, cleared requirement.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 14 November 2019 Resolved
There shall be at least two means of escape for the crew. The starboard side storeroom aft emergency exit was not able to be opened.
Action required: 17 - Rectify deficiencies prior to departure
Due 14 November 2019
Resolved 18 November 2019
Resolution: Vessel demonstrated proper operation.
07 - Fire Safety › N/A - No Subsystem › Fire-dampers
Issued 14 November 2019 Resolved
Means shall be provided to secure all the ventilation from outside the space. The forward house ventilation fire dampener is not able to be closed.
Action required: 17 - Rectify deficiencies prior to departure
Due 14 November 2019
Resolved 15 November 2019
Resolution: The fire dampener is operating properly.
08 - Alarms › N/A - No Subsystem › Machinery controls alarm
Issued 14 November 2019 Resolved
Vessel #2 generator is not operational due to a faulty fuel oil pump and cannot demonstrate safety controls. Vessel must repair the engine and prove proper operation of the safety controls to a USCG Marine Inspector or request ABS verification.
Action required: 705 - Other - as specified
Resolved 13 June 2020
Resolution: Vessel repaired engine and op tested in the presence of ABS inspector and was found to be satisfactory.
08 - Alarms › N/A - No Subsystem › Machinery controls alarm
Issued 14 November 2019 Resolved
Vessel port Z-drive hydraulic sump low level alarm is not working. Vessel must demonstrate operation of the alarm.
Action required: 17 - Rectify deficiencies prior to departure
Due 14 November 2019
Resolved 18 November 2019
Resolution: Vessel demonstrated proper operation of low hydraulic sump alarm.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 14 November 2019 Resolved
There is armored cable throughout the machinery spaces as well as throughout the exterior of the vessel. Vessel must submit a plan for approval to repair or replace all armor cable that is not continuous and installed with Section 25 of IEEE.
Action required: 705 - Other - as specified
Resolved 13 July 2020
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 19 August 2019 Resolved
Conduct test of port and starboard fire main system repairs the satisfaction of a Coast Guard Marine Inspector.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 20 August 2019
Resolution: Observed satisfactory test of vessel port and starboard fire pumps to 140 PSI.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 19 August 2019 Resolved
Conduct pneumatic test of fuel transfer system piping repairs to the satisfaction of a Coast Guard Marine Inspector.
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Resolved 20 August 2019
Resolution: Observed satisfactory test of vessel fuel transfer piping system to 125 PSI.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 19 August 2019 Resolved
Conduct pneumatic test of repairs to start air piping system to the satisfaction of a Coast Guard Marine Inspector.
Condition: Placed in Improper Service
Action required: 17 - Rectify deficiencies prior to departure
Resolved 20 August 2019
Resolution: Observed satisfactory test of vessel start air piping system to 125 PSI.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 19 August 2019 Resolved
Conduct final weld test of insert plate on starboard chain locker to the satisfaction of a Coast Guard Marine Inspector.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 20 August 2019
Resolution: Observed satisfactory final weld water hose test of insert plate.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 19 August 2019 Resolved
Portable fire extinguishers on board were found to be outside of servicing window. Provide valid servicing report for outdated fire extinguishers.
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 August 2019
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 19 August 2019 Resolved
#3 Ship's Service Diesel Generator shall remain out of service until Coast Guard Marine Safety Center approves shrink wrap repairs to the cables external sheathing.
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 September 2019
Resolved 19 September 2019
Resolution: Port Engineer provided documentation clearing outstanding
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 8 August 2019 Resolved
Conduct test of vessel CO2 system and repairs to the satisfaction of a Coast Guard Marine Inspector.
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Resolved 20 August 2019
Resolution: Observed satisfactory test of vessel CO2 System.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 9 December 2018 Resolved
Vessel reported a small electrical fire on the unloading pump motor. Prove proper operation of the unloading pump motor and related safety shutdowns prior to putting the unloading motor back into service.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 January 2019
Resolved 17 December 2018
Resolution: Vessel submitted report attesting to the replacement and final tests of the #2 motor to the industrial dredge plant unloading pump.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 29 November 2018 Resolved
Machinery must be in satisfactory condition and fit for the service for which it is intended. Vessel's starboard emergency bilge pump is inoperable. Vessel must repair or replace.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 1 December 2018
Resolution: Item cleared See ABS Class Report Number NY3593098
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 29 November 2018 Resolved
Machinery must be in satisfactory condition and fit for the service for which it is intended. Vessel's port and starboard emergency remote bilge suction valves are inoperable. Vessel must repair or replace.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 1 December 2018
Resolution: Item cleared See ABS Class Report Number NY3593098
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 29 November 2018 Resolved
Fire extinguishing equipment must be in satisfactory condition and fit for the service intended. Vessel must have Coast Guard attend next CO2 service inspection for verification of compliance.
Action required: 705 - Other - as specified
Resolved 20 August 2019
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 29 November 2018 Resolved
Repair ventilation covers to port and starboard Z-drive rooms.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 December 2018
Resolved 1 December 2018
Resolution: Item cleared See ABS Class Report Number NY3593098
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 29 November 2018 Resolved
Repair wasted rung on radar maintenance ladder on flying bridge.
Action required: 10 - Deficiency Rectified
Due 29 December 2018
Resolved 29 November 2018
Resolution: Item cleared See ABS Class Report Number NY3593098
Lifesaving › Rescue Boat › Embarkation/Disembarkation Capabilities
Issued 10 May 2018 Resolved
Material Failure to parts of the Davit System. Rescure Boat is unable to launch or be recovered.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 May 2018
Resolved 17 May 2018
Resolution: Vessel ordered a new freewheel and installed it. Tested the rescue boat davit and it held the load securely.
Construction/Loadline › Structures › Transverse Bulkhead
Issued 7 February 2018 Resolved
Make permanent repairs by way of insert, approx 18" x 24" piece of collision bulkhead. Insert to run from side shell to 3" (minimum) inside switchboard space. Insert to pass the bottom of port day oil tank. Replace piece of deck in chain locker IWO wastage at existing seam.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 14 February 2018
Construction/Loadline › Structures › Transverse Bulkhead
Issued 7 February 2018 Resolved
Schedule 3rd party gauging to be conducted as discussed in port chain locker/ballast tank. Notify USCG for attendance.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 8 February 2018
Resolution: Third party gauginging conducted; repair proposal discussed.
Construction/Loadline › Structures › Transverse Bulkhead
Issued 5 February 2018 Resolved
Coast Guard Sector NC was notified by vsl rep that during maintenance to equipment in fwd ballast tank a minor fuel smell and sheen was noticed. Upon further examination it is reported that there appears to be some wastage of the bulkhead which is allowing fuel to seep into the ballast tank. Remove fuel from adjacent tank and schedule a marine chemist to certify both tanks safe for entry. Vessel to be attended by CG Marine Inspector prior to movement.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 7 February 2018
Resolution: Attended vsl and surveyed damage. Issued 2 additional requirements.
Construction/Loadline › Hull › Weld
Issued 9 November 2017 Resolved
Make permanent repairs to the hull breech, ivo frame 64 in the port side lower machinery space.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 November 2017
Resolution: Fractured weld was gouged from both sides and full penetration welds completed.
Lifesaving › Launching Appliances › Falls
Issued 15 September 2016 Resolved
Port side davit safety limit switch found inoperable. Renew switch and confirm proper operation to the satisfaction ABS or attending MI.
Action required: 705 - Other - as specified
Due 25 September 2016
Resolved 26 September 2016
Resolution: ABS attended the vessel and witnessed proper operation of the davit and limit switch, all sat.
Engineering › Steering Gear System › Power Unit
Issued 2 October 2014 Resolved
RN WEEKS was not able to demonstrate a steering test. Conduct steering test to the satisfaction of attending marine inspection prior to departure from port.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 10 October 2014
Resolution: Conducted steering tests satisfactorily, cleared CG-835.
Lifesaving › Inflatable Liferafts › Approval
Issued 30 May 2012 Resolved
Install davit launch capable life rafts in accordance with safety plan. 46 CFR 96.06-1.
Action required: 705 - Other - as specified
Resolved 28 September 2012
Resolution: Resolved to the satisfaction of the attending Marine Inspectors.
Fire Fighting › Miscellaneous Items › Paint/Flammable Liquid Lockers
Issued 30 May 2012 Resolved
Ensure all flammable material is stored in a proper location or locker. 46 CFR 147.45(b).
Action required: 705 - Other - as specified
Due 18 October 2012
Resolved 28 September 2012
Resolution: Resolved to the satisfaction of the attending Marine Inspectors.
Fire Fighting › Miscellaneous Items › Paint/Flammable Liquid Lockers
Issued 30 May 2012 Resolved
Ensure all paint and grease lockers have adequate fire suppression coverage. 46 CFR 95.15(d)(6).
Action required: 705 - Other - as specified
Due 18 October 2012
Resolved 28 September 2012
Resolution: Resolved to the satisfaction of the attending Marine Inspectors.
Electrical › Lighting (emergency) › Lighting Fixture
Issued 30 May 2012 Resolved
Ensure operation of port life raft emergency light when on emergency power. 46 CFR 199.153(f)(6); 46 CFR 111.75-16.
Action required: 705 - Other - as specified
Due 18 October 2012
Resolved 28 September 2012
Resolution: Resolved to the satisfaction of the attending Marine Inspectors.
Electrical › Lighting (emergency) › Lighting Fixture
Issued 30 May 2012 Resolved
Provied lens cover for emergency light in port machinery space. 46 CFR 111.75-20.
Action required: 705 - Other - as specified
Due 18 October 2012
Resolved 28 September 2012
Resolution: Resolved to the satisfaction of the attending Marine Inspectors.
Electrical › Lighting (emergency) › Lighting Fixture
Issued 30 May 2012 Resolved
Ensure proper labeling of all emergency lights. 46 CFR 97.37-25.
Action required: 705 - Other - as specified
Due 18 October 2012
Resolved 28 September 2012
Resolution: Resolved to the satisfaction of the attending Marine Inspectors.
Lifesaving › Inflatable Liferafts › Servicing
Issued 30 May 2012 Resolved
Ensure ID cards for all life rafts are properly filled out. 46 CFR 199.190.
Action required: 705 - Other - as specified
Due 18 October 2012
Resolved 28 September 2012
Resolution: Resolved to the satisfaction of the attending Marine Inspectors.
Navigation › Piloting/Steering › Marine Charts
Issued 30 May 2012 Resolved
Ensure steering block diagram is posted in pilot house. 33 CFR 164.35(k).
Action required: 705 - Other - as specified
Due 18 October 2012
Resolved 28 September 2012
Resolution: Resolved to the satisfaction of the attending Marine Inspectors.
Electrical › Electrical Distribution System (service) › Panelboard
Issued 30 May 2012 Resolved
Provide ratings of circuit overcurrent protection on panelboard directories. 46 CFR 111.40-11(b)(2)(iii).
Action required: 705 - Other - as specified
Due 18 October 2012
Resolved 28 September 2012
Resolution: Resolved to the satisfaction of the attending Marine Inspectors.
Documentation › Safety/Response Plans/Programs › Fire Control Plans
Issued 28 November 2008 Resolved
PROVIDE UPDATED FIRE CONTROL PLAN REFLECTING RECENTLY INSTALLED A-CLASS FIRE DOOR AT STAIRWELL TO THE WHEELHOUSE.
Action required: 705 - Other - as specified
Due 15 December 2008
Resolved 29 December 2008
Resolution: Vsl provided documentation showing update to the vsl''s fire control plan.
Lifesaving › Launching Appliances › Davit
Issued 2 October 2008 Resolved
End for end rescue boat davit wire and weight test to 110% full weight. Weight test to be completed prior to departing the Mississippi River.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 2 November 2008
Resolved 14 October 2008
Lifesaving › Launching Appliances › Davit
Issued 2 October 2008 Resolved
Weight test new life raft davit wires to 110% of full weight. Weight test to be completed prior to departing the Mississippi River.
Action required: 705 - Other - as specified
Due 2 November 2008
Resolved 14 October 2008
Fire Fighting › Structural - A Class Divisions › Doors
Issued 2 October 2008 Resolved
Install Class A fire door in stairwell to bridge.
Action required: 705 - Other - as specified
Due 13 December 2008
Resolved 28 November 2008
Resolution: Visited vsl and examined installation of A-Class door at the wheelhouse stairwell as meeting A-0 boundary specifications of 46 CFR 72.05-25 and NVIC 9-97.
Documentation › Logs/Records › Logbook/Record (unofficial)
Issued 2 October 2008 Resolved
Provide lifesaving equipment maintenance logs.
Action required: 705 - Other - as specified
Due 2 November 2008
Resolved 14 October 2008
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 2 October 2008 Resolved
Prove proper operation of port side OWS
Action required: 705 - Other - as specified
Due 2 November 2008
Resolved 16 October 2008
Resolution: Provided calibration report.
Fire Fighting › Fire Pumps › Gland Sealing
Issued 21 September 2006 Resolved
Repair shaft packing on starboard fire pump.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 21 October 2006
Resolved 22 September 2006
Construction/Loadline › Structures › Door
Issued 21 September 2006 Resolved
Repair all water tight doors and hatches to ensure correct dog adjustment and water tight seal.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 21 September 2006
Resolved 22 September 2006
Engineering › Fuel Oil Service System › Hose
Issued 21 September 2006 Resolved
Renew two fuel oil pressure gauge lines on #1 ship service generator with SAE-J-1942 standard hose assemblies.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 21 October 2006
Resolved 22 September 2006
Electrical › Electric Generation Source (emergency) › Generator Cable
Issued 21 September 2006 Resolved
Provide and install chaffing gear on emergency generator battery cables.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 21 October 2006
Resolved 22 September 2006
Engineering › Fuel Oil Service System › Hose
Issued 21 September 2006 Resolved
Renew one fuel oil flexible hose with SAE- J- 1942 standard assembly on the emergency generator.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 21 October 2006
Resolved 22 September 2006
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 21 September 2006 Resolved
Service all eye wash stations and ensure all bottles have current expiration dates.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 21 October 2006
Resolved 22 September 2006
Fire Fighting › Fixed Fire Detection System › Heat Detectors
Issued 21 September 2006 Resolved
Properly seal the heat detector junction box over #3 generator engine.
Condition: Unknown
Action required: 705 - Other - as specified
Due 21 October 2006
Resolved 22 September 2006
Engineering › Bilge Water Management System › Manifold
Issued 21 September 2006 Resolved
Repair or renew check valve from bilge manifold to dirty ol tank in starboard engine room.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 21 October 2006
Resolved 28 September 2006
Construction/Loadline › Structures › Door
Issued 21 September 2006 Resolved
Repair dog wedges on engine control room water tight door.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Due 21 October 2006
Resolved 28 September 2006
Electrical › Lighting (emergency) › Lighting Fixture
Issued 21 September 2006 Resolved
Repair or renew emergency lighting at life raft stations on the port and starboard sides.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 21 October 2006
Resolved 28 September 2006
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 21 September 2006 Resolved
Provide 3rd party service and operation reports for the oily water seperator.
Condition: Unknown
Action required: 705 - Other - as specified
Due 21 October 2006
Resolved 28 September 2006
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Service
Issued 21 September 2006 Resolved
Provide 3rd party service reports for all portable fire extinguishers.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Due 21 October 2006
Resolved 28 September 2006
Lifesaving › Immersion Suits › General
Issued 26 September 2005 Resolved
Provide immersion suit for the cook of adquate size as required by 46 CFR 199.273. To be completed prior to sailing in the Atlantic Ocean between 32 degrees north and 32 degrees south or any other waters between 35 degrees north and 35 degrees south.
Condition: Improper/Lack of Maintenance
Due 26 October 2005
Resolved 29 November 2005
Resolution: Company provided statement from doctor that the cook''s weight is 363 lbs and the immersion suit on board is go for 375 lbs.
Lifesaving › Lifejacket/PFD (General) › Size
Issued 26 September 2005 Resolved
Provide lifejacket of suitable size for the cook.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 26 October 2005
Resolved 26 October 2005
Resolution: Lifejacket was provided that fits the cook.
Communications › Alarms/Indicators › Rudder Angle Indicator
Issued 28 September 2004 Resolved
Replace missing Rudder Angle Indicator for ER Control room. (Note: 26Oct04- HMRMS extended compliance date from 30Oct04 to 31Dec04 due to unavailability of parts).
Condition: Unknown
Action required: 705 - Other - as specified
Due 31 December 2004
Resolved 29 November 2004
Resolution: Recieved tech report showing replacment of angle indacator.
Construction/Loadline › Hull › Bottom Plating
Issued 3 January 2004 Resolved
Vessel made contact with drag head on 31Dec03. Damage to bottom plating IVO #3 port ballast tank outermost longitudinal at frame 52. Temp repairs consisted of a steel enclosure fabricated from 3/4" plate and seal welded around the 8-inch puncture. LEGACY COMPONENT DESC: Bottom Plating
Condition: Damaged By Earlier Event
Due 15 June 2004
Resolved 15 July 2004
Deck/Cargo › Mooring/Anchoring
Issued 25 September 2003 Resolved
provide a temporary anchor and conduct operational test. To the satisfaction of the attending CG inspector. LEGACY COMPONENT DESC: Anchor
Due 9 October 2003
Resolved 7 October 2003
Deck/Cargo › Mooring/Anchoring
Issued 25 September 2003 Resolved
Install the required AC-14 anchor. Make available for inspection, and conduct operational test. To be completed to the satisfaction of the CG inspector. LEGACY COMPONENT DESC: Anchor
Due 16 February 2004
Resolved 17 February 2004
Resolution: WITNESSED SAT INSTALLATION OF NEW AC-14 ANCHOR.
Navigation › Piloting/Steering
Issued 3 September 2003 Resolved
Prove illumination of magnetic compass. LEGACY COMPONENT DESC: Magnetic Compass
Condition: Unknown
Due 3 October 2003
Resolved 11 September 2003
Engineering › Diesel Engine (propulsion-electric)
Issued 15 April 2003 Resolved
Provide CG approved drawings for generator Power Limit Control modifications prior to getting underway. Drawings stamped " ABS approved on the behalf of the CG" under NVIC 10-82 will satisfy this requirement.
Action required: 705 - Other - as specified
Due 15 May 2003
Resolved 30 April 2003
Resolution: Approved drawings for the generator Power Limit Control have been submitted.
Engineering › Diesel Engine (propulsion-electric)
Issued 15 April 2003 Resolved
Prove proper operation and testing of generator Power Limit Control system prior to getting underway.
Action required: 705 - Other - as specified
Due 15 May 2003
Resolved 30 April 2003
Resolution: Satisfactory testing of the Power Limit Control system has been proved.
Construction/Loadline › Structures
Issued 5 July 2002 Resolved
Install door of an A0 ratting at the top of the ladder way to the 02 deck accommodations in compliance with the approved fire and safety plan LEGACY COMPONENT DESC: Door
Condition: Unknown
Due 20 September 2002
Resolved 20 September 2002
Resolution: RCVD COPY OF RECIPTS AND ORDER FORM FOR DOOR ALONG W/INSTALLATION PHOTOS
Navigation › Piloting/Steering
Issued 5 July 2002 Resolved
Provide new compass deviation card. LEGACY COMPONENT DESC: Compass Deviation Table
Condition: Unknown
Due 20 September 2002
Resolved 20 September 2002
Resolution: Sighted copy of deviation card.
Lifesaving
Issued 6 July 2001 Resolved
RENEW FALLS ON RESCUE BOAT DAVIT AND CONDUCT WEIGHT TEST. TEST WEIGHT TO BEWEIGHT OF BOAT AND EQUIPMENT PLUS 10%. NOTE- PERSONNEL DO NOT RIDE IN THE BOAT WHEN ITS BEING RAISED OR LOWERED.
Condition: Unknown
Due 6 August 2001
Resolved 19 September 2001
Lifesaving
Issued 13 July 1999 Resolved
MODIFY RESCUE BOAT CRADLE AND MOUNT OUTBOARD ENGINE ON RESCUE BOAT. PROVIDE OPERATIONAL TEST OF RESCUE BOAT.
Condition: Unknown
Due 13 July 1999
Resolved 13 July 1999
Construction/Loadline
Issued 13 July 1999 Resolved
REMOUNT BILGE PUMP MACHINERY GUARD IN PORT ENGINE ROOM MACHINERY SPACE.
Condition: Unknown
Due 13 July 1999
Resolved 13 July 1999
Engineering
Issued 13 July 1999 Resolved
AMMEND ENGINE ROOM AUTOMATION PROCEDURE TO REFLECT AUTO CONTROL MODE (A.1-2OF AUTOMATION PROCEDURES) OR RESUBMIT PROCEDURES TO REFLECT EQUIPMENT AND OPERATIONS.
Condition: Unknown
Due 13 July 1999
Resolved 13 July 1999
Accommodation/Occupational Safety
Issued 13 July 1999 Resolved
SECURE DECK PLATES IN ALL MACHINERY SPACES._x001C_
Condition: Unknown
Due 13 July 1999
Resolved 13 July 1999
Electrical
Issued 13 July 1999 Resolved
OPERATIONALLY TEST ALL SAFETIES ON NUMBER SIX GENERATOR.
Condition: Unknown
Due 13 August 1999
Resolved 31 August 1999
Electrical
Issued 13 July 1999 Resolved
IDENTIFY ALL EMERGENCY LIGHTS WITH LABELS.
Condition: Unknown
Due 13 July 1999
Resolved 13 July 1999
Fire Fighting
Issued 13 July 1999 Resolved
PROVIDE TWO 12 FOOT APPLICATORS FOR USE WITH 2 1/2" FIRE NOZZLES. MOUNT APPLICATORS ON EXTERIOR OF VESSEL SUPERSTRUCTURE FORE AND AFT FOR USE WITH EXTERIOR FIRE STATIONS.
Condition: Unknown
Due 30 July 1999
Resolved 30 July 1999
Fire Fighting
Issued 13 July 1999 Resolved
PROVE OPERATION OF ALL GENERAL HIGH TEMPERATURE JACKET WATER ALARMS.
Condition: Unknown
Due 13 August 1999
Resolved 31 August 1999
Documentation
Issued 13 July 1999 Resolved
PROVIDE USCG APPROVED FIRE PLAN TO ENCOMPASS ALL CHANGES MADE TO CURRENT FIRE PLAN.
Condition: Unknown
Due 13 July 1999
Resolved 13 July 1999
Documentation
Issued 13 July 1999 Resolved
PROVIDE VALID FCC CARGO SHIP ARADIO SAFETY TELEPONE CERTIFICATE WITH PROPEREXPERATION DATES.
Condition: Unknown
Due 13 July 1999
Resolved 13 July 1999
Construction/Loadline
Issued 13 July 1999 Resolved
ADJUST WATERTIGHT DOORS ON STARBOARD CONTROL ROOM AND STORE ROOM.
Condition: Unknown
Due 13 July 1999
Resolved 13 July 1999
Documentation
Issued 13 July 1999 Resolved
UPDATE OIL TRANSFER PROCEDURE AS PER 33CFR 155.750.
Condition: Unknown
Due 13 July 1999
Resolved 13 July 1999
Engineering
Issued 13 July 1999 Resolved
REPLACE BOTH AIR COMPRESSOR FLEXIBLE DISCHARGE HOSES.
Condition: Unknown
Due 13 July 1999
Resolved 13 July 1999
Lifesaving
Issued 13 July 1999 Resolved
PROVIDE TWO PAIR OF FIREFIGHTING BOOTS TO BE USED WITH FIREFIGHTING ENSEMBLE.
Condition: Unknown
Due 13 July 1999
Resolved 13 July 1999
Lifesaving
Issued 10 September 1998 Resolved
END FOR END, AND TEST INSTALLATION OF STARBOARD LIFERAFT DAVIT. 46 CFR 199.190 (J)
Condition: Unknown
Due 10 September 1998
Resolved 10 September 1998
Lifesaving
Issued 10 September 1998 Resolved
REPLACE ALL CHEMILUMINESCENT-TYPE LIGHTS ON THE LIFEJACKETS AND IMMERSION SUITS WITH LIGHTS APPROVED UNDER 46 CFR 161.112 OR 161.012. 46 CFR 199.620(E)
Condition: Unknown
Due 10 September 1998
Resolved 10 September 1998
Accommodation/Occupational Safety
Issued 15 July 1997 Resolved
Provide a fitted cover for deep-fat fryer.
Condition: Unknown
Due 15 August 1997
Resolved 9 October 1997
Accommodation/Occupational Safety
Issued 15 July 1997 Resolved
Provide 1-800 #'s for Employee Assistance Program POC's for company drug program.
Condition: Unknown
Due 15 August 1997
Resolved 9 October 1997
Fire Fighting
Issued 15 July 1997 Resolved
Renew 4ft flexible crossover branch line and test to 1000psi, also tighten sirens in both engine rooms and the coupling in the bottle bank room.
Condition: Unknown
Due 15 July 1997
Resolved 9 October 1997
Electrical
Issued 15 July 1997 Resolved
Conduct test run and safety inspection of #4 SSDG in presence of CG marine inspector.
Condition: Unknown
Due 15 August 1997
Resolved 9 October 1997
Electrical
Issued 15 July 1997 Resolved
Conduct operation test to include overspeed trip in presence of CG marine inspector.
Condition: Unknown
Due 15 August 1997
Resolved 9 October 1997
Engineering
Issued 10 March 1997 Resolved
Determine cause of loss of steering to port propulsion unit and make repairs to unit. Provide operational test of port propulsion unit.
Condition: Unknown
Due 31 March 1997
Resolved 1 April 1997
Deck/Cargo
Issued 21 December 1995 Resolved
Make permanent repairs to the #1 and #4 hopper unloading boxes/piping starboard side._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 21 December 1995
Resolved 21 December 1995
Construction/Loadline
Issued 21 December 1995 Resolved
Gauge rust scaled areas in #2,3,4, and 5, port void spaces along inboard edge, crop and renew where necessary.
Condition: Unknown
Due 21 December 1995
Resolved 21 December 1995
Lifesaving
Issued 21 December 1995 Resolved
Conduct weight test of liferaft davit arms._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 21 December 1995
Resolved 21 December 1995
Construction/Loadline
Issued 21 December 1995 Resolved
Replace 04 Wafer type Sea Valves as per 46 CFR 56.20.9(c)._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 21 December 1995
Resolved 21 December 1995
Construction/Loadline
Issued 21 December 1995 Resolved
Remove sand from #2 and #3 starboard void spaces and forward pumprooms bilges for inspection on inner bottom hull.
Condition: Unknown
Due 21 December 1995
Resolved 21 December 1995
Navigation
Issued 20 July 1995 Resolved
REPLACE BURNED OUT INDICATOR LIGHTS IN BRIDGE ALARM PANEL.
Condition: Unknown
Due 20 July 1995
Resolved 20 July 1995
Electrical
Issued 20 July 1995 Resolved
PROVE PROPER OPERATION OF #4 PROPULSION GENERATOR ALARMS (INCL. LOW LUBE ALARM/SHUTDOWN, REVERSE POWER, AND OVERSPEED).
Condition: Unknown
Due 24 October 1995
Resolved 24 October 1995
Electrical
Issued 20 July 1995 Resolved
REPAIR PORT GENERATOR ROOM GENERAL ALARM LIGHT.
Condition: Unknown
Due 30 August 1995
Resolved 30 August 1995
Accommodation/Occupational Safety
Issued 6 July 1994 Resolved
REPAIR OR REPLACE AFT PILOT HOUSE DOOR. (LABLED "V" ON DOOR PLAN) _x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 15 September 1994
Resolved 15 September 1994
Accommodation/Occupational Safety
Issued 6 July 1994 Resolved
CROP AND RENEW WASTED VENTILATION DUCT LOCATED IN THE STBD GENERATOR ROOM. _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 15 September 1994
Resolved 15 September 1994
Accommodation/Occupational Safety
Issued 6 July 1994 Resolved
REPLACE ALL WASTED BALLAST TANK VENT SCREENS._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 15 September 1994
Resolved 15 September 1994
Lifesaving
Issued 6 July 1994 Resolved
INSTALL SHAFT GUARD ON JET PUMP LOCATED IN PORT GENERATOR ROOM._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 15 September 1994
Resolved 15 September 1994
Navigation
Issued 6 July 1994 Resolved
PROVE PROPER OPERATION OF THE ENGINEROOM E.O.T._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 15 September 1994
Resolved 15 September 1994
Lifesaving
Issued 6 July 1994 Resolved
PROVIDE THREE ADDITIONAL LINE THROWING APPARATUS PER 46 CFR 94.45-15. _x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 6 July 1994
Resolved 6 July 1994
Fire Fighting
Issued 24 June 1992 Resolved
PROVE PROPERA OPERATION OF THE GENERATOR ALARM BELL IN THE PORT STEERING ROOM.
Condition: Unknown
Due 24 June 1992
Resolved 24 June 1992
Electrical
Issued 24 June 1992 Resolved
PROVE PROPER OPERATION OF #1 S/S GEN OVERSPEED LOW LUBE OIL AND HIGH TEMP TRIPS AND REVERSE POWER RELAY.
Condition: Unknown
Due 24 June 1992
Resolved 24 June 1992
Lifesaving
Issued 24 June 1992 Resolved
CONDUCT FIRE AND ABANDON DRILLS UPON REACTIVATION OF VESSEL.
Condition: Unknown
Due 24 June 1992
Resolved 24 June 1992
Lifesaving
Issued 24 August 1991 Resolved
PROVIDE USCG APPROVED LIFESAVING AND FIREFIGHTING PLAN REFLECTING RELOCATION OF LIFERAFT AND EPIRB._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 24 August 1991
Resolved 24 August 1991
Lifesaving
Issued 24 August 1991 Resolved
PROVIDE GENERAL ALARM BELLS IN STEERING MACHINERY COMPARTMENTS PORT AND STBD.
Condition: Unknown
Due 24 August 1991
Resolved 24 August 1991
Lifesaving
Issued 24 August 1991 Resolved
PROVIDE APPROPRIATE VENTILATION, EMERGENCY LIGHTING AND GENERAL ALARM BELLSIN #7-S VOID SPACE IN ACCORDANCE WITH USCG APPROVED PLANS PRIOR TO USING ASA STORE ROOM OR MANNED SPACE._x001C_
Condition: Unknown
Due 24 August 1991
Resolved 24 August 1991
Accommodation/Occupational Safety
Issued 24 August 1991 Resolved
PROVE PROPER OPERATION AND EGRESS CAPABILITY OF PORT AFT MACHINERY SPACE ESCAPE HATCH BELOW HOUSE._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 24 August 1991
Resolved 24 August 1991
Engineering
Issued 24 August 1991 Resolved
PROVIDE USCG APPROVED PLANS FOR INSTALLATION OF ADDITIONAL VENT DUCT IN STBD FWD ENGINEROOM.
Condition: Unknown
Due 24 August 1991
Resolved 24 August 1991
Fire Fighting
Issued 24 August 1991 Resolved
PROVIDE USCG APPROVED FIREFIGHTING PIPING PLAN REFLECTING FIRE MAIN MODIFICATION IN AFT RAM WELL AND ADDITION OF (3) ISOLATION VALVES._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 24 August 1991
Resolved 24 August 1991
Accommodation/Occupational Safety
Issued 24 August 1991 Resolved
PROVE PROPER OPERATION AND EGRESS CAPABILITY OF PORT AFT MACHINERY SPACE ESCAPE HATCH BELOW HOUSE._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 13 September 1991
Resolved 13 September 1991
Construction/Loadline
Issued 24 August 1991 Resolved
PROVIDE USCG APPROVED PLANS AND STABILITY CALCULATIONS FOR MODIFICATION OF #7-S VOID SPACE AND THE ADDITION OF THE SINGLE POINT BOW DISCHARGE AND MOORING CONNECTION MFG. BY STAPEL OF HOLLAND.
Condition: Unknown
Due 24 August 1991
Resolved 24 August 1991
Lifesaving
Issued 24 August 1991 Resolved
SUBMIT PROPOSAL TO PERMANENTLY RELOCATE DAVIT LAUNCH LIFERAFTS TO WEATHER PROTECTED LOCATION._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 24 August 1991
Resolved 24 August 1991
Engineering
Issued 13 August 1990 Resolved
REPAIR RAW WATER LINE.
Condition: Unknown
Due 13 August 1990
Resolved 13 August 1990
Navigation
Issued 13 August 1990 Resolved
PROVIDE ONE LINE THROWING ROCKET.
Condition: Unknown
Due 13 August 1990
Resolved 13 August 1990
Construction/Loadline
Issued 13 August 1990 Resolved
REPLACE GALLEY AND 01 DECK WEATHER TIGHT DOORS.
Condition: Unknown
Due 13 August 1990
Resolved 13 August 1990
Lifesaving
Issued 13 August 1990 Resolved
SHOW SERVICING OF THE HYDROSTATIC RELEASES.
Condition: Unknown
Due 13 August 1990
Resolved 13 August 1990
Engineering
Issued 6 December 1989 Resolved
THE VESSEL'S BOW THRUSTER IS TO REMAIN SECURED AND THE GEAR OIL SUPPLY CLOSED UNTIL SUCH TIME AS THE VESSEL IS DRYDOCKED, THE OIL SEAL LEAK IS REPAIRED; AND A COAST GUARD MARINE INSPECTOR HAS WITNESSED SAID REPAIRS.
Condition: Unknown
Due 6 December 1989
Resolved 6 December 1989
Engineering
Issued 18 July 1989 Resolved
PROVIDE PROPER OPERATION OF STARBOARD ENGINEROOM HIGH BILGE ALARM
Condition: Unknown
Due 18 July 1989
Resolved 18 July 1989
Fire Fighting
Issued 18 July 1989 Resolved
PROVE PROPER OPERATION OF BRIDGE FIRE ALARM INDICATOR PANEL
Condition: Unknown
Due 18 July 1989
Resolved 18 July 1989
Lifesaving
Issued 4 November 1988 Resolved
REPLACE THE TEMPORARY REPLACEMENT LIFERAFT WITH A DAVIT LAUNCH LIFERAFT.
Condition: Unknown
Due 4 November 1988
Resolved 4 November 1988
Accommodation/Occupational Safety
Issued 4 November 1988 Resolved
REPAIR GUARD RAIL STANCHIONS ON LADDER IN WAY OF THE STARBOARD OVERBOARD DISCHARGE PIPE AT BOW.
Condition: Unknown
Due 4 November 1988
Resolved 4 November 1988
Lifesaving
Issued 2 November 1988 Resolved
PROVIDE ANNUAL SERVICING ON THE TWO 25 PERSON INFLATABLE LIFERAFTS AND INSTALL SAME ON VESSEL.
Condition: Unknown
Due 2 November 1988
Resolved 2 November 1988
Navigation
Issued 2 November 1988 Resolved
CONDUCT AN EMERGENCY STEERING DRILL AND LOG SAME IN VESSEL'S OFFICIAL LOG. (ORIGINAL COMPLIANCE DATE IS 02DEC88)
Condition: Unknown
Due 2 November 1988
Resolved 2 November 1988
Fire Fighting
Issued 2 November 1988 Resolved
PROVIDE OPERATIONAL TEST OF FIXED CO2 SYSTEMS, EMERGENCY ALARMS, TIME DELAY AND SHUT DOWNS. (ORIGINAL COMPLIANCE DATE IS 02DEC88)
Condition: Unknown
Due 2 November 1988
Resolved 2 November 1988
Navigation
Issued 2 November 1988 Resolved
PROVIDE CHART #12314.
Condition: Unknown
Due 2 November 1988
Resolved 2 November 1988
Navigation
Issued 2 November 1988 Resolved
PROVIDE MOST RECENT EDITION OF U. SO COAST PILOT AND U. S. COAST GUARD LIGHT LIST, VOLUME 2.
Condition: Unknown
Due 2 November 1988
Resolved 2 November 1988
Navigation
Issued 2 November 1988 Resolved
INSTALL OPERATING INSTRUCITONS FOR EMERGENCY STEERING CHANGE OVER PROCEDURES ON BIRDGE.
Condition: Unknown
Due 2 November 1988
Resolved 2 November 1988
Fire Fighting
Issued 2 November 1988 Resolved
MARK OR STENCIL LOCATION OF THE EMERGENCY GEAR LOCKERS (FOR FIRE FIGHTING EQUIPMENT) IN WAY OF LOCKERS.
Condition: Unknown
Due 2 November 1988
Resolved 2 November 1988
Lifesaving
Issued 11 April 1988 Resolved
PROVIDE THE CORRECT OPERATING INSTRUCTIONS FOR THE DAVIT LAUNCHED RAFTS ONBOARD AT THE LAUNCHING STATION AND IN THE GALLEY.
Condition: Unknown
Due 11 April 1988
Resolved 11 April 1988
Lifesaving
Issued 11 April 1988 Resolved
RESTORE DAVIT LAUNCHED RAFTS TO THEIR ORIGINAL LOCATION, INSTALLED SO AS TOBE DAVIT LAUNCHED OR DEMONSTRATE TO A COAST GUARD INSPECTOR THAT THE RAFTS CAN BE DAVIT LAUNCHED FROM THEIR PRESENT LOCATION.
Condition: Unknown
Due 11 April 1988
Resolved 11 April 1988
Lifesaving
Issued 11 March 1988 Resolved
HAVE PORT & STARBOARD LIFERAFTS RESERVICED AND REINSTALLED WITH PROPER RETENTION STRAPS.
Condition: Unknown
Due 11 March 1988
Resolved 11 March 1988
Electrical
Issued 30 July 1987 Resolved
MAKE PERMANENT REPAIRS TO #4 MAIN GENERATOR AND TEST IN PRESENCE OF MARINE INSPECTOR.
Condition: Unknown
Due 30 July 1987
Resolved 30 July 1987
Fire Fighting
Issued 20 July 1987 Resolved
FOR THE PYROTECNICS SYSTEM 3 FIRE ALARM SYSTEM: SUBMIT TO MSC FOR REVIEWS AND APPROVAL THE INSTALLATION DRAWINGS WITH A BILL OF MATERIALS OF THE COMPONENTS PATICULAR TO THE INSTALLATION AND THE LOCATING WHERE THEY WILL BE INSTALLED.
Condition: Unknown
Due 20 July 1987
Resolved 20 July 1987
Documentation
Issued 20 July 1987 Resolved
PROVIDE PROOF OF USCG VESSEL DOCUMENTATION ON DELIVERY OF VESSEL IN DELAWARE (STATE NUMBER IS DL4839C).
Condition: Unknown
Due 20 July 1987
Resolved 20 July 1987
Electrical
Issued 20 July 1987 Resolved
PROVIDE PROOF OF ABS APPROVAL & CG-MSC ACCEPTANCE OF THE PRESENTLY INSTALLED "MEGASYSTEMS" MONITORING & CONTROL OF THE ENGINEERING PLANT.
Condition: Unknown
Due 20 July 1987
Resolved 20 July 1987
Fire Fighting
Issued 20 July 1987 Resolved
PROVIDE PROOF OF ABS APPROVED AND CG-MSC ACCEPTANCE OF THE PRESENTLY INSTALLED "MEGASYSTEMS" FIRE-DETECTION EQUIPMENT. '
Condition: Unknown
Due 20 July 1987
Resolved 20 July 1987
Engineering
Issued 20 July 1987 Resolved
PROVIDE AN AUTOMATED SYSTEMS TEST PROCEDURE IN ACCORDANCE WITH NVIC 1-69 TOBE APPROVED BY THE COAST GUARD.
Condition: Unknown
Due 20 July 1987
Resolved 20 July 1987
Electrical
Issued 20 July 1987 Resolved
PROVIDE ALTERNATE SHIP'S SERVICE TRANSFORMER SUPPLY APPROVED BY ABS UNDER NVIC 10-82.
Condition: Unknown
Due 20 July 1987
Resolved 20 July 1987
Fire Fighting
Issued 20 July 1987 Resolved
PROVIDE 1 EACH INDUCTOR-TYPE PORTABLE FOAM APPLICATOR WITH PICKUP TUBE AND 2 EACH 5-GALLON PAILS FOAM LIQUID FOR PORT ENGINE ROOM (PER SUPPLIER SOTEC CONFIRMATION TO MCDERMOTT SHIPYARDS, PROMISED DELIVERY DATE 24JUL87).
Condition: Unknown
Due 20 July 1987
Resolved 20 July 1987
Engineering
Issued 20 July 1987 Resolved
PROVIDE AN OPERATION & MAINTENANCE PROGRAM IN ACCORDANCE WITH NVIC 1-69 TO BE APPROVED BY THE COAST GUARD.
Condition: Unknown
Due 20 July 1987
Resolved 20 July 1987

Casualty record · 14

29 January 2003Routine · role: Involved in a Marine Casualty · activity 1737844
1 February 2003Routine · role: Involved in a Marine Casualty · activity 1739691
16 January 2005Routine · role: Involved in a Marine Casualty · activity 2277828
30 October 2005Routine · role: Involved in a Marine Casualty · activity 2546722
31 July 2010Routine · role: Involved in a Marine Casualty · activity 3832556
24 September 2013Routine · role: Involved in a Marine Casualty · activity 4740383
30 June 2016Routine · role: Involved in a Marine Casualty · activity 5932019
2 November 2017Routine · role: Involved in a Marine Casualty · activity 6330149
27 August 2018Routine · role: Involved in a Marine Casualty · activity 6524661
24 April 2020Routine · role: Involved in a Marine Casualty · activity 6943704
3 February 2021Routine · role: Involved in a Marine Casualty · activity 7136042
18 January 2023Routine · role: Involved in a Marine Casualty · activity 7632650
8 March 2023Routine · role: Involved in a Marine Casualty · activity 7659238
25 November 2023Routine · role: Involved in a Marine Casualty · activity 7829942
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Recorded names · 1

RN WEEKS (2003–2023). Names as the Coast Guard recorded them in incident records, with the years they appear; some are renames and some are spelling variants.

Ownership record