Records from 2007 to 2025. Most recent: inspection, 11 December 2025.
Everything above is free. The detail below — the inspection history, the deficiency record, the casualty record and the documentation record — is Professional, $39 a month. Sign in.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 11 December 2025
Resolved
46 CFR 182.100
All machinery and equipment must be installed and maintained in such a manner as to afford adequate protection from causing fire, explosion, machinery failure, and personnel injury. MI observed hydraulic leaks on both steering rams. Enact permanent repairs to the satisfaction of USCG Marine Inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Due 11 December 2025
Resolved 15 December 2025
Resolution: Steering rams were re-built.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 11 December 2025
Resolved
46 CFR 182.455 (b) (4)
The shutoff valve at the tank must be manually operable from outside the compartment in which the valve is located. MI observed that valves were not completely closing. Enact permanent repairs to the satisfaction of USCG Marine Inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Due 11 December 2025
Resolved 15 December 2025
Resolution: Cables that close valves were replaced and adjusted.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 11 December 2025
Resolved
46 CFR 181.405 (c)
Vessels described by 46 CFR 175.110(c) must have an interconnected fire detection system in compliance with § 181.450 installed in all enclosed areas where passengers and crew have routine access, including accommodation spaces and machinery spaces. MI observed
that detector in engine room was not operational, and
that a detector was not installed in the pilothouse.
Enact permanent repairs to the satisfaction of USCG
Marine Inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Due 11 December 2025
Resolved 15 December 2025
Resolution: Detector in engineroom was replaced and detector was installed in pilothouse.
11 - Life Saving Appliances › N/A - No Subsystem › Evaluation, testing and approval
Issued 11 December 2025
Resolved
46 CFR 180.210 (a)
A vessel of more than 19.8 meters (65 feet) in length must carry at least one rescue boat unless the cognizant OCMI determines that the vessel is sufficiently maneuverable, arranged, and equipped to allow the crew to recover a helpless person from the water. During a demonstration of helpless person recovery, the Marine Inspector observed that the recovery method was unsatisfactory. The vessel shall propose procedures and demonstrate a safe and effective method for recovering a helpless person from the water.
Action required: 701 - Prior to carriage of passengers/cargo
Due 24 December 2025
Resolved 21 January 2026
Resolution: Witnessed MOB drill with new recovery system.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 11 December 2025
Resolved
46 CFR 176.810 (b) (ii)
Monthly inspections required by NFPA 10 may be conducted by the owner, operator, person-in-charge, or a designated member of the crew. Vessel logs indicated that fire extinguishers were not being inspected monthly
Corrected on the spot.
Action required: 10 - Deficiency Rectified
Due 11 December 2025
Resolved 11 December 2025
Resolution: Corrected on the spot.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance and inspections
Issued 11 December 2025
Resolved
46 CFR 185.728 (a)
Each EPIRB, other than an EPIRB in an inflatable life raft, must be tested monthly, using the integrated test circuit and output indicator, to determine that it is operative. Vessel logs indicated that EPIRB was not being tested monthly. Corrected on the spot.
Action required: 10 - Deficiency Rectified
Due 11 December 2025
Resolved 11 December 2025
Resolution: Corrected on the spot.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 18 February 2025
Resolved
Exhaust gas must not leak from the piping or any
connections in the exhaust system.
Both port and stbd exhaust pipes were leaking cooling
water from the flexible coupling just before passing
through the aft bulkhead. Make repairs to the Coast
Guards satisfaction.
46 CFR 182.430
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 March 2025
Resolved 25 February 2025
Resolution: Exhuast clamps were replaced. Exhaust water leaks were corrected.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 18 February 2025
Resolved
Vessel on a Oceans route must carry a total of 12
distress signals, 6 red, 6 smoke, or 12 red. All
distress signals were 1 month expired. New distress
signals were purchased and on board prior to completing
the inspection.
46 CFR 180.68
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 18 February 2025
Resolved 18 February 2025
Resolution: New distress signals were purchased and on board prior to inspection completion.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 18 February 2025
Resolved
At each inspection each item of fire protection
equipment shall be ready for inspection. The 5th, extra,
fire extinguisher in the E/R had no charge. Service,
replace, or remove to the satisfaction of the Coast
Guard.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 March 2025
Resolved 25 February 2025
Resolution: The extra fire extinguisher was recharged by a third party, SAT.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 18 February 2025
Resolved
A visual and audible alarm must be provided at the
operating station to indicate high water. The visual
light for compartment 1 was not working. Repair to the
satisfaction of the Coast Guard.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 March 2025
Resolved 25 February 2025
Resolution: Light bulb was replaced for compartment 1 indicator. SAT.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 9 January 2025
Resolved
Deck material wastage discovered beyond 25% within fuel tank room. Repair to the satisfaction of the CG.
Action required: 705 - Other - as specified
Resolved 31 January 2025
Resolution: Attended vessel to confirm. All sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 9 January 2025
Resolved
Excessive shaft movement discovered on port and starboard shafts. Remove and inspect. Provide objective evidence to the satisfaction of the CG shafts are not damaged or worn.
Action required: 705 - Other - as specified
Resolved 31 January 2025
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 6 January 2025
Resolved
46 CFR 182.100
Machinery and equipment installed on each vessel must be suitable for the vessel and its operation and for the purpose intended. Vessel reported port engine water pump failed. Vessel shall enact permanent repairs to the satisfaction of USCG Marine Inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Due 6 January 2025
Resolved 9 January 2025
Resolution: Water pump replaced. Operational test sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 6 December 2023
Resolved
All engine exhaust pipes must be water cooled.
MI found the starboard engine exhaust cooling water hose to be deteriorated needing replacement.
46 CFR 182.425
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 December 2023
Resolved 12 December 2023
Resolution: New exhaust cooling water hose was installed.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 6 December 2023
Resolved
Each connection to a conductor or terminal part of a conductor must be made within an enclosure.
Junction box for the DC system located forward of the door on the port side to the accommodation space has no means of closure exposing the wire connections and breakers.
46 CFR 183.340(g)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 December 2023
Resolved 12 December 2023
Resolution: Cover for junction box was installed.
09 - Working and Living Conditions › 092 - Working Conditions › Guards - fencing around dangerous machinery parts
Issued 6 December 2023
Resolved
An exposed hazard, such as gears or rotating machinery, must be properly protected by a cover, guard, or rail.
MI observed the guard for the belt on the vessel's generator to be missing.
46 CFR 183.340(g)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 December 2023
Resolved 12 December 2023
Resolution: Guard was properly installed.
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 6 December 2023
Resolved
At each initial and subsequent inspection for certification the owner or managing operator shall be prepared to test the steering systems of the vessel and make them available for inspection to the extent necessary to determine that they are in suitable condition and fit for the service intended.
MI found the connection joint of the starboard side ram of the steering gear to be loose causing play in the system.
46 CFR 176.814
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 December 2023
Resolved 12 December 2023
Resolution: Connection was properly tightened.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 6 December 2023
Resolved
Each window, port hole, and its means of attachment to the hull or deck house, must be capable of withstanding the maximum load from wave and wind conditions expected due to its location of the vessel and the authorized route of the vessel.
MI observed two broken windows, one located in the wheel house and one on the galley door.
46 CFR 177.1020
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 December 2023
Resolved 4 January 2024
Resolution: Vessel rep provided pictures of the two new windows installed on the vessel.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 6 December 2023
Resolved
A lighting fixture must be installed as follows: Each fixture must comply with 183.200.
MI observed the lighting fixture in front of the wheelhouse to be missing the bulb exposing the socket.
46 CFR 183.410(c)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 December 2023
Resolved 12 December 2023
Resolution: Light fixture and bulb was properly replaced.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 14 September 2023
Resolved
Vessels described by 46 CFR 175.110(c) must have an interconnected fire detection system in compliance with § 181.450 installed in all enclosed areas where passengers and crew have routine access, including accommodation spaces and machinery spaces.
Vessel shall install system to the satisfaction of attending USCG Marine Inspector.
46CFR185.405(c)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 October 2023
Resolved 14 November 2023
Resolution: Vessel installed new interconnected fire detection system, MI witnessed operational test. All sat.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 14 September 2023
Resolved
Flammable items not otherwise covered by the regulations of this subchapter, such as rechargeable batteries, including lithium ion batteries utilized for commercial purposes, must be handled, stored, and operated in a way that mitigates the risk of hazardous conditions.
Vessel shall develop plan to the satisfaction of attending USCG Marine Inspector.
46CFR185.364
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 October 2023
Resolved 14 November 2023
Resolution: Vessel does not allow passengers to charge devices on board.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 1 July 2023
Resolved
Propulsion machinery must be suitable in type and design for propulsion requirements and capable of operating at constant marine load under such requirements without exceeding its design limitations.
Vessel experienced power load failure and lost propulsion capabilities as a result.
Repair failed equipment and demonstrate proper operation of machinery to attending USCG Marine Inspector prior to carrying passengers.
46 CFR 182.200(a)
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 July 2023
Resolved 2 July 2023
Resolution: Vessel representatives replaced starter, in-line fuse, and battery switch. Attending MI/IO witnessed proper operation of STBD Engine.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 8 November 2022
Resolved
All vessels must have navigation lights that are in compliance with the applicable sections of the International and Inland Navigation Rules.
MI found the stern light extinguished.
The vessel is limited to daylight without reduced visibility operations.
46 CFR 183.420
Action required: 17 - Rectify deficiencies prior to departure
Due 8 November 2022
Resolved 14 November 2022
Resolution: MI inspected stern light after repair.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 8 November 2022
Resolved
At each initial inspection for certification of a vessel the owner or operator shall have the vessel ready for inspection all machinery essential to the routine operation of the vessel.
MI found the ships service diesel generator (SSDG) leaking fuel from the fuel manifold.
46 CFR 176.804(c)
Action required: 17 - Rectify deficiencies prior to departure
Due 8 November 2022
Resolved 14 November 2022
Resolution: MI inspected SSDG and found no leaks.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 8 November 2022
Resolved
At each initial inspection for certification of a vessel the owner or operator shall have the vessel ready for inspection all machinery essential to the routine operation of the vessel.
MI found the ships service diesel generator leaking fuel from the fuel manifold.
46 CFR 176.804(c)
Action required: 17 - Rectify deficiencies prior to departure
Due 8 November 2022
Resolved 14 November 2022
Resolution: MI inspected SSDG and found no leaks.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 8 November 2022
Resolved
At each initial inspection for certification of a vessel the owner or operator shall have the vessel ready for inspection all machinery essential to the routine operation of the vessel.
MI found the starboard MDE emergency fuel shut off valve not completely closing when activated.
46 CFR 176.804(c)
Action required: 17 - Rectify deficiencies prior to departure
Due 8 November 2022
Resolved 14 November 2022
Resolution: MI inspected fuel shut off and found it sat.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 8 November 2022
Resolved
The enclosures of all equipment shall be permanently grounded to the metal hull of the vessel by the mounting bolts or other means.
MI found metallic enclosures ungrounded.
46 CFR 183.10-20(g)
Action required: 17 - Rectify deficiencies prior to departure
Due 8 November 2022
Resolved 14 November 2022
Resolution: MI found the enclosures properly grounded.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 8 November 2022
Resolved
A dual voltage generator installed on a vessel shall be of the grounded type, where the neutral of a dual voltage system must be solidly connected at the switchboard's neutral bus.
MI found no neutral to ground.
46 CFR 183.324(a)(1)
Action required: 17 - Rectify deficiencies prior to departure
Due 8 November 2022
Resolved 14 November 2022
Resolution: MI found the system properly grounded.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 8 November 2022
Resolved
Ground detection must be provided for a dual voltage alternating current system.
The dual voltage AC electrical generator is missing ground detection at the switchboard.
46 CFR 183.324(c)(1)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 December 2022
Resolved 13 December 2022
Resolution: The operator received approved electrical plans from MSC and installed ground fault detection at the switchboard.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 8 November 2022
Resolved
On a metallic vessel, a grounded alternating current system must be grounded to the hull.
MI fund the 110 volt AC appliances ungrounded.
46 CFR 183.376(d)
Action required: 17 - Rectify deficiencies prior to departure
Due 8 November 2022
Resolved 14 November 2022
Resolution: MI inspected found the system properly grounded.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 8 November 2022
Resolved
During a fire in the engine room causality the vessel shall follow the emergency checklist including closing air supply by closing ventilators.
MI found in the engine room aft port overhead a ventilation duct without a dampener.
46 CFR 185.25-5(c)
Action required: 17 - Rectify deficiencies prior to departure
Due 8 November 2022
Resolved 14 November 2022
Resolution: MI found dampeners in place.
04 - Emergency Systems › N/A - No Subsystem › Water level indicator
Issued 8 November 2022
Resolved
On a vessel of at least 26 feet) in length, a visual and audible alarm must be provided at the operating station to indicate a high water level.
MI found the bilge high level alarms OOC.
46 CFR 185.530(a)
Action required: 17 - Rectify deficiencies prior to departure
Due 8 November 2022
Resolved 14 November 2022
Resolution: MI found the bilge alarms working properly.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 8 November 2022
Resolved
The neutral of each grounded generation and distribution system must be grounded at the generator switchboard.
MI found the neutral ungrounded.
46 CFR 183.376(c)
Action required: 17 - Rectify deficiencies prior to departure
Due 8 November 2022
Resolved 14 November 2022
Resolution: MI found the system properly grounded.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 8 November 2022
Resolved
Each vessel shall be provided with safe, readily available and sufficient firefighting equipment necessary to extinguish a fire.
MI found leaking fire main pipes above the main fire pump in the engine room.
46 CFR 181.01-5
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 November 2022
Resolved 14 November 2022
Resolution: MI inspected system and found no leaks.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 8 November 2022
Resolved
New installations of electrical equipment and material, and the repair or replacement of wire and cable, on an existing vessel, shall be completed to the satisfaction of the cognizant [name withheld] found multiple deficiencies in the electrical system to include: missing grounding conductors for all AC items onboard, missing ground bus bar in the distribution panel, missing neutral to ground at the switchboard, and missing ground detection at the switchboard.
The vessel shall submit electrical repair plans to MSC for approval.
46 CFR 183.115(c)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 December 2022
Resolved 13 December 2022
Resolution: The operator received approved AC electrical plans from MSC. The installation matches approved plans.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 8 November 2022
Resolved
Each portable fire extinguisher on a vessel must be of an approved type.
MI found a 40-B:C fire extinguisher waisted from corrosion.
Rectify within 7 days.
46 CFR 181.500(a)
Action required: 705 - Other - as specified
Due 15 November 2022
Resolved 14 November 2022
Resolution: MI found inspected fire extinguisher sat.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 8 November 2022
Resolved
All cable and wire must be installed with metal supports spaced not more than 24 inches apart, and in such a manner as to avoid chafing and other damage.
MI found wiring in the AC compartment not properly affixed to metal brackets.
Rectify within 7 days.
46 CFR 183.340(b)(4)
Action required: 705 - Other - as specified
Due 15 November 2022
Resolved 14 November 2022
Resolution: MI found cables sat.
02 - Structural Conditions › N/A - No Subsystem › Stability/strength/loading information and instruments
Issued 8 November 2022
Resolved
All vessels must have permanent draft marks at each end of the vessel or have permanent load markings placed on either side of the forward, amidships, and aft to indicate the maximum allowable draft and trim.
MI found the draft makings required by the vessels stability letter missing from the hull.
Repair during next drydock.
46 CFR 185.30(b)(1)
Action required: 705 - Other - as specified
Due 30 September 2023
Resolved 27 January 2023
Resolution: MI received photos of draft markings.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 8 November 2022
Resolved
All vessels must have navigation lights that are in compliance with the applicable sections of the International and Inland Navigation Rules, except that a vessel of more than (65 feet) in length must also have navigation lights that meet UL 1104, Standards for Marine Navigation Lights.
MI found navigation lights including, port side light, starboard side light, and mast light lenses severely corroded.
Rectify within 14 days.
46 CRF 183.420
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 November 2022
Resolved 14 November 2022
Resolution: Operator received lights and installed them.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 8 November 2022
Resolved
Each ring life buoy must be marked in clearly legible block capital letters with the vessel's name.
MI found ring life buoys markings faded and unreadable.
Rectify within 7 days.
46 CFR 185.604(b)
Action required: 705 - Other - as specified
Due 15 November 2022
Resolved 14 November 2022
Resolution: MI found life rings properly marked.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 8 November 2022
Resolved
Each ring life buoy on a vessel must be approved in accordance with 46 CFR 160.050 in subchapter Q of this chapter.
MI found the starboard aft life ring buoy to be unserviceable due to a cracked water tight plug in the body of the buoy.
Rectify within 7 days.
46 CFR 180.70(b)(1)
Action required: 705 - Other - as specified
Due 15 November 2022
Resolved 14 November 2022
Resolution: MI found new life ring buoy installed.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 8 November 2022
Resolved
The fire pump outlet shall be fitted with a pressure gauge.
The MI found the fire pump pressure gauge unserviceable.
46 CFR 181.10-1(c)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 November 2022
Resolved 14 November 2022
Resolution: MI found new gauge installed and showing 61 PSI within the system.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 8 November 2022
Resolved
Each penetration of a watertight bulkhead shall be Accomplished by using an approved method.
MI found missing packing encompassing a cable run from the fuel space to the engine room.
46 CFR 182.40
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 November 2022
Resolved 14 November 2022
Resolution: MI found the packing around the cable sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 8 November 2022
Resolved
Where flexibility is necessary, a section of flexible metallic hose may be used and is double clamped where practicable.
MI found 5 hose clamps missing from the wet exhaust system.
Rectify within 7 days.
46 CFR 182.430(e)
Action required: 705 - Other - as specified
Due 15 November 2022
Resolved 14 November 2022
Resolution: MI found all hose clamps properly placed.
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 8 November 2022
Resolved
The platform must be arranged so that under normal stowed conditions, it can be retained in the center of the float and can be readily released from this position for use.
MI found the life float basket affixed using an unapproved nylon cord.
Rectify within 7 days.
46 CFR 160.027-3(e)
Action required: 705 - Other - as specified
Due 15 November 2022
Resolved 14 November 2022
Resolution: MI found life float basket properly affixed.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 2 February 2022
Resolved
Each connection to a conductor or terminal part of a conductor must be made within an enclosure.
The PA speaker conductor connections on the main deck were not made within an enclosure and conductors are exposed to the elements.
46 CFR 183.340(g)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 February 2022
Resolved 16 February 2022
Resolution: The operator enclosed the connection in a UL listed enclosure.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 2 February 2022
Resolved
All cable and wire must be installed with metal supports spaced not more than 24 inches apart. The conductors on the main deck located behind where the life jackets are stored on port/stbd upper shelves are not supported.
The conductors are tangled with the life jackets and create a hazard to passengers/crew when removing life jackets.
46 CFR 183.340(a)(4)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 February 2022
Resolved 16 February 2022
Resolution: The conductors are supported every 24 inches and placed against the bulkhead tightly so as not to interfere with the removal of lifejackets.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 27 March 2021
Resolved
Propulsion machinery shall be suitable in type and design for propulsion requirements of the hull in which it is installed and capable of operating at constant marine load under such requirements without exceeding its designed limitations.
Vessels Starboard engine failed while the vessel was underway with passengers.
After troubleshooting and engine is operational, conduct Sea trials in the presence of Coast Guard marine Inspector.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 30 March 2021
Resolution: Owner Operator replaced intercooler, tested main engine under approximately 60-70% load at the dock with technician in the presence of OCMI.
05 - Radio Communications › N/A - No Subsystem › MF Radio installation
Issued 3 February 2021
Resolved
A vessel must comply with the applicable requirements for any radio and EPIRB installation as set forth in 47 CFR part 80. The vessel's MF-DSC single side band radio is inoperable. The vessel is restricted to voyages no further than 20 miles from shore. 46 CFR 184.502
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 March 2021
Resolved 10 September 2021
Resolution: New MF installed and new FCC safety cert issued 03MAY2021.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 3 February 2021
Resolved
Repairs or alterations to the hull, machinery, or equipment that affect the safety of the vessel must not be made without approval of OCMI. Identified heavy pitting corrosion on two transverse frames in the engine compartment. Engine room frames #1 and #2 (numbered from aft to fwd) were found pitted. Crop and renew frames at the next scheduled dry dock. 46 CFR 176.700
Action required: 705 - Other - as specified
Due 30 September 2021
Resolved 29 September 2021
Resolution: Forward port frame renewed. Aft port frame and stbd frames coated to arrest corrosion.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 3 February 2021
Resolved
The exhaust piping shall be so arranged as to be gas tight throughout its length. Identified corroded exhaust piping in the lazarette for the ship's generator. The corrosion is located at the rubber hose connection for flexibility and permits the flow of exhaust vapor into the space. Make satisfactory repairs and contact MI for re-inspection when complete. 46 CFR 182.20-20
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 February 2021
Resolved 17 February 2021
Resolution: The operator removed the flexible piping and grinded 1/4" of corroded metal to good metal. New flexible piping that extends 4" beyond the metal pipe was installed and the system was placed back into service.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 12 September 2019
Resolved
The OCMI may require an inspection and testing whenever a repair or alteration is undertaken.
Following main propulsion rebuild and steering gear servicing, conduct sea trials in the presence of a marine inspector. Prior to Credit Dry-dock. 46 CFR176.700(d)
Action required: 705 - Other - as specified
Resolved 18 October 2019
Resolution: Conducted satisfactory sea trials.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 6 February 2019
Resolved
All vessels shall be provided with a satisfactory arrangement for draining any watertight compartment other than small buoyancy compartments, under all practical conditions.
MI observed unapproved nonmetallic flexible hose at discharge end of bilge system from auxiliary pump. Replace unapproved hoses with approved bilge piping, as listed below, and provide satisfactory operational test.
Approved Bilge piping materials:
1.) Metallic (Aluminum)
2.) Rigid Nonmetallic (PVC)
3.) SAE J-1942 Nonmetallic Flexible Hose w/ approved
1475 fittings.
4.) SAE J-1527 or J-2006 Nonmetallic Flexible Hoses,
meeting the following additional requirements:
- Length of hose must be less than 30 in.
- System pressure must be less than 5 psig.
- Where practicable, have 2 hose clamps at both
ends.
IAW: 46 CFR 182.25-1, 46 CFR 182.40-15, 46 CFR 182.720 (e)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 February 2019
Resolved 27 February 2019
Resolution: Vessel O/O replaced unapproved nonmetallic flexible hose w/ manufactured fittings and conducted satisfactory operational test.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 6 February 2019
Resolved
In systems and applications where flexible hoses are permitted to be clamped, double hose clamping is required where practicable.
MI observed missing hose clamps on multiple generator hoses. Repair.
IAW: 46CFR182.410 (d) (1)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 February 2019
Resolved 19 February 2019
Resolution: O/O replaced missing double hose clamps.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 6 February 2019
Resolved
Where life preservers are stowed so that they are not readily visible to passengers, the containers in which they are stowed shall be marked "life preservers".
MI observed faded/illegible life preserve stowage markings in accommodation space. Repair.
IAW: 46 CFR 185.30-15
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 February 2019
Resolved 27 February 2019
Resolution: Vessel O/O adequately marked all life jacket stowage.
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 6 February 2019
Resolved
Each item of lifesaving equipment determined by the marine inspector to not be in serviceable condition must be repaired or replaced.
MI observed tear/hole on inside grab line of life-float. Repair.
IAW: 46 CFR 176.808 (b)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 February 2019
Resolved 19 February 2019
Resolution: O/O repaired tear/hole in grab line with patch.
09 - Working and Living Conditions › 092 - Working Conditions › Safe means of access
Issued 6 February 2019
Resolved
All escape hatches and other emergency exits shall be marked on both sides using 1-inch letters: "Emergency Exit, Keep Clear".
Escape hatch in engine room was not properly labeled. Label escape hatch with proper wording in no less than 1-inch letters.
IAW: 46 CFR 185.30-15
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 February 2019
Resolved 19 February 2019
Resolution: O/O properly labled emergency exit from engine room to galley.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 6 February 2019
Resolved
A vessel is inspected for compliance with the standards required by this subchapter. Machinery, equipment, materials, and arrangements not covered by standards in this subchapter may be inspected in accordance with standards acceptable to the cognizant OCMI as good marine practice.
MI observed forward rope deck pipe missing cover. Replace.
IAW: 46 CFR 16.800 (a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 February 2019
Resolved 19 February 2019
Resolution: O/O replaced missing rope deck pipe cover.
Lifesaving › Lifefloat › Serviceable
Issued 10 October 2017
Resolved
Install 2 life floats in kind and reduce manning to 40 pax and 4 crew iaw 46CFR180.10-5
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 15 November 2017
Resolution: Deficiency cleared at the moment of the COI 15NOV17.
Communications › Radio Communications › VHF Radiotelephone
Issued 1 March 2017
Resolved
Provide GPS input to VHF radio containing MMSI number for DSC. 46 CFR 184.502
Action required: 705 - Other - as specified
Due 15 March 2017
Resolved 13 March 2017
Resolution: Installed new VHF-FM radio with GPS input and MMSI number.
Stability › Watertight Integrity › General
Issued 1 March 2017
Resolved
Replace missing gasket on aft watertight hatch; prove watertight. 46 CFR 179.360
Action required: 705 - Other - as specified
Due 15 March 2017
Resolved 13 March 2017
Resolution: Replaced missing gasket
Stability › Watertight Integrity › General
Issued 1 March 2017
Resolved
Replace missing lanyard on forepeak hatch. 46 CFR 176.360(b)(2)
Action required: 705 - Other - as specified
Due 15 March 2017
Resolved 13 March 2017
Resolution: Replaced missing lanyard.
Electrical › Lighting (service) › Lighting Fixture
Issued 1 March 2017
Resolved
Replace three inoperable lighting fixtures in accommodation space. 46 CFR 183.410
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 March 2017
Resolved 13 March 2017
Resolution: All lighting in accomodation space replaced with LED lighting.
Engineering › Diesel Engine (propulsion-direct drive) › Gear/Clutch Starter (electric)
Issued 24 October 2016
Resolved
Port Engine was reported inoperable. Make proper repairs and prove satisfactory operation of engine. Deficiency is in effect once vessel is dockside. 46CFR 182.200
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 October 2016
Resolution: Corrected to the satisfaction of the Marine Inspector.