Inspection history · 21
2 June 2026
Drydock Exam · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8385919
26 March 2026
Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8331355
26 June 2025
COI Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8161206
12 December 2024
Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8046878
24 October 2024
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 8023987
6 June 2024
Drydock Exam · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7929118
15 February 2024
Internal Structural Exam · Drydock Exam · Administrative Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7864347
22 March 2023
Drydock Exam · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7655192
25 February 2022
Deficiency Check · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7401852
21 June 2021
Drydock Exam · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7231280
7 May 2021
Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7191992
2 July 2020
Annual Inspection · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7002023
17 May 2019
COI Inspection · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6686248
27 February 2019
Internal Structural Exam · Hull Examination · Examination of Repairs
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6638895
11 December 2018
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 6595581
20 April 2018
Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6395391
29 December 2017
Administrative Inspection · Deficiency Check
Physical examination · Navigation Center · Activity 6330218
30 March 2017
Annual Inspection · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6114181
12 December 2016
Hull Examination · In-Service Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6211718
29 April 2016
Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 5865337
29 April 2016
Internal Structural Exam · Drydock Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 5865800
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 26 March 2026
Resolved
A vessel must have two independent means of controlling each propulsion engine. Control must be provided for the engine speed, direction of shaft rotation, and engine shutdown.
The port engine starter solenoid is inoperable, preventing the port engine from starting at the control station. Repair or replace the port engine starter solenoid to restore proper starting functionality.
46 CFR 184.620(a)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 1 April 2026
Resolution: Received evidence of newly installed solenoid and video of PORT ME successful remote start w/ old solenoid uninstalled
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 26 March 2026
Resolved
Each ring life buoy be marked with Type II retroflective material approved in accordance with 46 CFR 164.018.
Three life ring buoys on board vessel are missing Type II retroflective material. Add retroflective type material on life ring buoys.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 April 2026
Resolved 1 April 2026
Resolution: Received photo of ring life buoys w/ name marked and retroflective tape installed
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 26 June 2025
Resolved
"At each initail and subsequent inspection for certification and reinspection the inspector shall examine and test all items in the ship;s outfit such as navigational lights... Such examination and test shall be to the extent necessary to determine that the condition of the item is satisfactory and that it is fit for the service intended." Light bulbs for the vessels port,starboard,mast, and spot light need to be replaced.
46CFR176.25-40 (OLD T)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 July 2025
Resolution: Operator submitted pictures of new nav lights installed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 26 June 2025
Resolved
"Suitable covers, guards or rails shall be installed in way of all exposed and hazardous places." Exposed rotatig machinery belt on port main propulsion engine.
46CFR177.35-15(a) (OLD T)
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 5 August 2025
Resolution: 05AUG25: Recieved pictures from operator rectifing this deficiency.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 26 June 2025
Resolved
"Vessel shall be equipped with a suitable number of portable battery lights." Vessel not equipped with portable lights, portable lights needed.
46CFR184.30-1 (OLD T)
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 11 July 2025
Resolution: Operator submitted pictures of portable lights onboard.
02 - Structural Conditions › N/A - No Subsystem › Bulkhead strength
Issued 24 October 2024
Resolved
(a)Repairs or alterations to the hull, machinery, or equipment that affect the safety of the vessel must not be made without the approval of the cognizant OCMI...
...
(d) The OCMI may require an inspection and testing whenever a repair or alteration is undertaken
Per your correspondence on 23OCT2024, we approve your plan to alter the watertight door and bulkhead separating the water tank room and engine room. Schedule a visit with our office to NDT the alterations.
46 CFR 176.700
Action required: 705 - Other - as specified
Resolved 7 March 2025
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 13 April 2023
Resolved
The owner or managing operator shall make a vessel available for drydock examinations, internal structural examinations, and underwater surveys required by this section.
Complete credit dry dock prior the carriage of passengers.
46CFR115.600
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 13 May 2023
Resolved 7 March 2025
Resolution: Credit issued when vessel was splashed
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 25 February 2022
Resolved
Vessel's generator had duck tape as support for wires and cable instead of metal support.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 March 2022
Resolved 27 July 2022
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 25 February 2022
Resolved
M.I noticed loose coupling on the port engine shaft.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 March 2022
Resolved 27 July 2022
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 25 February 2022
Resolved
The vessel did not have the required fire wrench at their fire station.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 March 2022
Resolved 27 July 2022
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 21 June 2021
Resolved
STBD side under water tanks as marked and called out from keel to approximately 2 feet up from keel have significant wastage. Provide repair proposal.
Action required: 705 - Other - as specified
Due 28 February 2022
Resolved 25 February 2022
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-corrosion
Issued 21 June 2021
Resolved
STBD side under water tanks 01 frame as marked and called out has significant wastage. Provide repair proposal.
Action required: 705 - Other - as specified
Resolved 25 February 2022
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 7 May 2021
Resolved
Owners and operators must make the vessel ready for inspection in accordance with this sub chapter if issuance of a COI is desired. Presently this vessel's port side rudder post was inconsistently moving port and starboard during steering test. Vessel must comply with the following prior to carrying passengers:
1. Complete a Form CG–948: "Permit to Proceed" prior to transit to dry dock
2. Complete a satisfactory dry dock addressing steering issue with rudder post
3. Conduct a satisfactory sea trails and drills with attending marine inspector
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 25 February 2022
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 7 May 2021
Resolved
Placards containing instructions for the donning and use of the life jackets aboard the vessel must be posted in
conspicuous places. Vessel does not have life jacket donning instructions to reflect all the life jacket styles on board.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 25 February 2022
04 - Emergency Systems › N/A - No Subsystem › Muster list
Issued 7 May 2021
Resolved
The emergency inspections and station bill must be mounted at the operating station. Station bill and emergency broadcast placard was posted on main deck and
not conveniently located for the operating station use.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 25 February 2022
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 7 May 2021
Resolved
On a vessel of more than 19.8 meters (65 feet) in
length, the minimum capacity of the fire pump must be 189 liters (50 gallons) per minute at a pressure of not less than 414 kPa (60 psi). The fire main pump pressure gauge was unable to produce over 60 psi with one hose operating from the forward fire station.
Condition: Design Flaw
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 25 February 2022
09 - Working and Living Conditions › 092 - Working Conditions › Protection machinery
Issued 7 May 2021
Resolved
An exposed hazard, such as gears or rotating machinery, must be properly protected by a cover, guard, or rail.
Both main engines have exposed moving parts and belts on the forward side.
Condition: Design Flaw
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 25 February 2022
01 - Certificates & Documentation › 011 - Ships Certificates › USCG Certificate of Documentation (COD)
Issued 7 May 2021
Resolved
The person in command of a documented vessel must have on board that vessel the original Certificate of Documentation currently in effect for that vessel.
Vessel's Certificate of Documentation has expired.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 25 February 2022
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 2 July 2020
Resolved
01 Cite: 46CFR182.520(e)(4) Action: 701 Code: c
Observed bilge strainers were not properly attached. Reconfigure bilge strainer.
Action required: 701 - Prior to carriage of passengers/cargo
Due 2 July 2020
Resolved 23 July 2020
Resolution: Witnessed satisfactory repair.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 2 July 2020
Resolved
02 Cite: 46CFR182.455(b)(4) Action: 701 Code: c
Observed port and starboard fuel shut off valves did not operate satisfactorily. Demonstrate operation of fuel shutoff valves.
Action required: 701 - Prior to carriage of passengers/cargo
Due 2 July 2020
Resolved 23 July 2020
Resolution: Witnessed satisfactory repair.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 2 July 2020
Resolved
03 Cite: 46CFR182.310 Action: 16 Code: c
Observed hydraulic leak under helm. Correct hydraulic leak.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 July 2020
Resolved 23 July 2020
Resolution: Witnessed satisfactory repair.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 2 July 2020
Resolved
04 Cite: 46CFR179.320 Action: 16 Code: c
Observed fuel shutoff valve was not watertight at deck penetration. Make watertight where fuel shutoff valves penetrate the deck.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 July 2020
Resolved 23 July 2020
Resolution: Witnessed satsifactory repair.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 17 May 2019
Resolved
Machinery installed on vessel must be installed and maintained to afford adequate protection from failure. Replace leaking gasket on fire pump.
Action required: 705 - Other - as specified
Due 7 June 2019
Resolved 19 June 2019
02 - Structural Conditions › N/A - No Subsystem › Closing devices/watertight doors
Issued 17 May 2019
Resolved
Each watertight bulkhead/door must be of sufficient strength to be capable of remaining watertight. Make forward watertight door watertight on all sides with a good gasket seal.
Action required: 705 - Other - as specified
Due 7 June 2019
Resolved 19 June 2019
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 17 May 2019
Resolved
Protect passengers and crew from electrical hazards. Isolate and locate existing ground on system.
MODIFIED 6/19/2019: INSTALL ISOLATION TRANSFORMER TO ELMINATE GROUND COMING FROM SHORESIDE CONNECTION.
Action required: 705 - Other - as specified
Due 19 July 2019
Resolved 23 July 2020
Resolution: Witnessed satisfactory repair.
Engineering › Diesel Engine (propulsion-reduction gear) › Exhaust Manifold
Issued 30 March 2017
Resolved
Replace eshaust hose section on the outboard side of the port engine and double clamp.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 13 April 2017
Resolved 12 April 2017
Resolution: Rep supplied photo evidence that hose had been replaced.
Communications › Radio Communications › VHF Radiotelephone
Issued 30 March 2017
Resolved
Program MMSI number in VHF radio.
Action required: 705 - Other - as specified
Due 30 April 2017
Resolved 2 May 2017
Resolution: Confirmed MMSI programmed into VHF.
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 30 March 2017
Resolved
Prove accurate and up to date crew list in accordance with DAPI.
Action required: 705 - Other - as specified
Due 30 April 2017
Resolved 2 May 2017
Resolution: Verified DAPI crew list.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 30 March 2017
Resolved
Prove unexpired contents of first aid kit, including pain relivers, eye wash, and burn cream.
Action required: 705 - Other - as specified
Due 13 April 2017
Resolved 12 April 2017
Resolution: Supplied photo evidence of new first aid kit.
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 30 March 2017
Resolved
Properly label lifejacket storage areas.
Action required: 705 - Other - as specified
Due 13 April 2017
Resolved 12 April 2017
Resolution: Rep provided photo evidence of proper livejacket storage labeling.