Records from 1988 to 2001. Most recent: inspection, 10 April 2001.
Inspection history · 11
10 April 2001
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 289006
20 March 2000
Type not recorded
No type recorded · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 275836
3 August 1998
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 418782
11 December 1997
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 410386
7 August 1997
Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 406594
16 November 1996
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 397401
13 August 1996
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 394212
26 October 1995
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 384125
1 December 1992
Type not recorded
No type recorded · MSO GUAM · USCG Oceania District (CGD-O) · Activity 354786
26 October 1988
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 326496
13 April 1988
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 322669
Engineering
Issued 10 April 2001
Resolved
PRIOR TO DEPARTURE REMOVE PROTECTIVE COVERINGS AROUND VENTILATION GOOSE NECKS TO ALLOW TANKS/SPACES TO BREATH.
Condition: Unknown
Due 10 April 2001
Resolved 11 April 2001
Construction/Loadline
Issued 10 April 2001
Resolved
PRIOR TO 10MAY01 PROVIDE ADEQUATE CLOSURE FOR PAINT LOCKER DOOR.
Condition: Unknown
Due 10 May 2001
Resolved 13 April 2001
Lifesaving
Issued 10 April 2001
Resolved
PRIOR TO DEPARTURE REMOVE EXCESS OIL FROM AFT STEERING BILGES.
Condition: Unknown
Due 10 April 2001
Resolved 11 April 2001
Navigation
Issued 10 April 2001
Resolved
PRIOR TO DEPARTURE PROVIDE SERVICE REPORT ON DEVIATION BETWEEN GYRO AND MAGNETIC COMPASS. DEVIATION WAS 27 DEGREES OFF.
Condition: Unknown
Due 10 April 2001
Resolved 11 April 2001
Electrical › Electrical Distribution System (emergency) › Non-conducting Deck Covering
Issued 10 April 2001
No resolution recorded
PRIOR TO 10MAY01 PROVIDE ELECTRCAL SAFETY MATTING FOR ALL SWITCH BOARDS.
Condition: Unknown
Action required: 15 - Rectify deficiencies by next port
Engineering › Fuel Oil Service System › Ventilation
Issued 10 April 2001
No resolution recorded
PRIOR TO 10MAY01 PROVIDE FLAME SCREENS FOR ALL FUEL OIL VENTS THROUGHOUT SHIP.
Condition: Unknown
Action required: 15 - Rectify deficiencies by next port
Navigation
Issued 10 April 2001
Resolved
PRIOR TO 10MAY01 PROVIDE GOOD EMERGENCY STEERING DIRECTIONS.
Condition: Unknown
Due 10 May 2001
Resolved 13 April 2001
Navigation › Emergency Steering › Communications to Emergency Steering
Issued 10 April 2001
No resolution recorded
PRIOR TO 10MAY01 REPAIR COMMS BETWEEN AFT STEERING AND BRIDGE. UNABLE TO CLEARING UNDERSTAND OR HEAR.
Condition: Unknown
Action required: 15 - Rectify deficiencies by next port
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type II
Issued 10 April 2001
No resolution recorded
PRIOR TO 10MAY01 PROVIDE CLASS ATTESTMENT THAT MSD IS AN APPROVED IN ACCORDANCE WITH MARPOL.
Condition: Unknown
Action required: 15 - Rectify deficiencies by next port
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type II
Issued 10 April 2001
No resolution recorded
PRIOR TO 10MAY01 MAKE PERMANENT REPAIRS TO APPARENT TEMPORARY FIXES TO MSD PIPING.
Condition: Unknown
Action required: 15 - Rectify deficiencies by next port
Fire Fighting › Combustible Materials › Paints/Varnishes/Other Finishes
Issued 10 April 2001
No resolution recorded
PRIOR TO 10MAY01 PROVIDE FIXED FIRE EXTINGUISHING FOR PAINT LOCKER.
Condition: Unknown
Action required: 15 - Rectify deficiencies by next port
Fire Fighting › Combustible Materials › Paints/Varnishes/Other Finishes
Issued 10 April 2001
No resolution recorded
PRIOR TO 10MAY01 REMOVE PAINT AND CLEANERS FROM TEMPORARY PAINT STOWAGE ANDPLACE IN PAINT LOCKER.
Condition: Unknown
Action required: 15 - Rectify deficiencies by next port
Navigation
Issued 10 April 2001
Resolved
PRIOR TO DEPARTURE PROVIDE RULES OF THE ROAD.
Condition: Unknown
Due 10 April 2001
Resolved 11 April 2001
Navigation
Issued 10 April 2001
Resolved
PRIOR TO DEPARTURE PROVIDE MANEUVERING FACT SHEET.
Condition: Unknown
Due 10 May 2001
Resolved 11 April 2001
Documentation
Issued 3 August 1998
Resolved
VESSEL HAD TWO DIFFERENT EXPIRATION DATES ON THE IOPP CERT. (SPANISH/ENGLISH). MUST CORRECT AND PROVIDE NEW FORM A (RECORD OF EQUIPMENT) BY 18AUG98.
Condition: Unknown
Due 11 April 2001
Resolved 11 April 2001
Lifesaving
Issued 3 August 1998
Resolved
VESSEL DID NOT HAVE A TRAINING MANUAL THAT WAS VESSEL SPECIFIC, MUST PROVIDE MANUAL IAW SOLAS CH III/18.2 PREPARED FOR THE VESSEL, NOT GENERIC PURCHASED IN A STORE.
Condition: Unknown
Due 11 April 2001
Resolved 11 April 2001
Documentation
Issued 11 December 1997
Resolved
TRAINING MANUAL FOR LIFESAVING MISSING. SOLAS 74 (AMEND) REG III/18.2
Condition: Unknown
Due 3 August 1998
Resolved 3 August 1998
Accommodation/Occupational Safety
Issued 7 August 1997
Resolved
VEGETABLE STORGE REFRIGERATOR EMERGENCY ESCAPE DEVICE FROZEN AND INOPERABLE. REPAIR BY 07AUG97 OR PRIOR TO DEPARTING JACKSONVILLE.
Condition: Unknown
Due 7 August 1997
Resolved 7 August 1997
Engineering
Issued 7 August 1997
Resolved
OIL TRANSFER PROCEDURES NOT POSTED. CORRECT BY 07AUG97 OR NEXT U.S. TRANSFER OPERATION.
Condition: Unknown
Due 7 August 1997
Resolved 7 August 1997
Engineering
Issued 7 August 1997
Resolved
VESSEL DID NOT HAVE CONTAINMENT PROVIDED FOR THE FUEL MANIFOLD AND VENTS ASREQUIRED BY 33 CFR 155.320(A)(1). CORRECT PRIRO TO 07AUG97 OR PRIOR TO NEXT U.S. TRANSFER OPERATION.
Condition: Unknown
Due 7 August 1997
Resolved 7 August 1997
Documentation
Issued 7 August 1997
Resolved
VESSEL DID NOT HAVE A GARBAGE DISPOSAL LOG. CORRECT BY 07AUG97 OR PRIOR TODEPARTURE FROM JACKSONVILLE.
Condition: Unknown
Due 7 August 1997
Resolved 7 August 1997
Navigation
Issued 7 August 1997
Resolved
VESSELS HORN NOT OPERATIONAL. CORRECT BY 07AUG97, OR PRIOR TO DEPARTURE FROM JACKSONVILLE.
Condition: Unknown
Due 7 August 1997
Resolved 7 August 1997
Engineering
Issued 16 November 1996
Resolved
The lagging on the exhaust piping from the hot water heater is wasted and in need of repair. Vessel was given until their 20 year special survey in May 1997 to correct._x001C_ _x001C_
Condition: Unknown
Due 7 August 1997
Resolved 7 August 1997
Construction/Loadline
Issued 13 August 1996
Resolved
Remove all oil and oily residue from engine room bilges, machinery, and allcontainments._x001C_ See SOLAS 74 (Amended) I/11(a)
Condition: Unknown
Due 16 August 1996
Resolved 20 August 1996
Engineering
Issued 13 August 1996
Resolved
Renew as original the two deteriorated sea water pipes located in the forward starboard corner of the lower level of the engine room beneath the_x001C_#1 air compressor._x001C_ See SOLAS 74 (Amended) I/11(a)
Condition: Unknown
Due 31 August 1996
Resolved 26 August 1996
Engineering
Issued 13 August 1996
Resolved
Renew as original the deteriorated sea water supply pipe to the fresh watergenerator located in the engineroom. _x001C_ See SOLAS 74 (Amended) I/11(a)
Condition: Unknown
Due 7 August 1997
Resolved 7 August 1997
Documentation
Issued 26 October 1995
Resolved
PROVIDE VALID LETTER OF COMPETENCY FROM THE PANAMANIAN GOVERNMENT FOR THE 2ND OFFICER, 2ND ENGINEER, AND 3RD ENGINEER PRIOR TO DEPARTURE.
Condition: Unknown
Due 30 October 1995
Resolved 1 November 1995
Documentation
Issued 1 December 1992
Resolved
VESSEL HAD A LINE DIAGRAM BUT NO OIL TRANSFER PROCEDURES. CG FURNISHED A COPY.
Condition: Unknown
Due 1 December 1992
Resolved 1 December 1992
Accommodation/Occupational Safety
Issued 26 October 1988
Resolved
33 CFR 159.7(C) A VESSEL WITH AN ISNSTALLED TOILET MUST HAVE AN APPROVED OPERABLE MARINE SANITATION DEVICE.
Condition: Unknown
Due 1 December 1992
Resolved 1 December 1992
Accommodation/Occupational Safety
Issued 13 April 1988
Resolved
33CFR159.7(C) A VESSEL WITH AN INSTALLED TOILET MUST HAVE AN OPERABLE MARINE SANITATION DEVICE.
Condition: Unknown
Due 1 December 1992
Resolved 1 December 1992