RIVER LOOP

RIVER LOOP is a 2001 passenger vessel (inspected). The Coast Guard has recorded 41 inspections since 2001, most recently in September 2025, along with 61 deficiencies and 5 casualty investigations between 2006 and 2025.

Records from 2001 to 2025. Most recent: inspection, 15 September 2025.

Built
2001
Last inspected
15 September 2025
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDJ6214
Flag
UNITED STATES
367795520
Maury page id
psix-29027

Inspections, by type

…with no type recorded6
Years with a record 20 calendar years (2001–2025)
The 41 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)48.0 ft × 20.0 ft × 4.5 ft
Registered tonnagegross 73 / net 73
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderSUSQUEHANNA SANTEE BOATWORKS INC · WILLOW STREET, PA, UNITED STATES · built 2001
Hull materialAluminum
PropulsionGasoline Outboard
Hull shapeShip
Hull configurationTwin Hull
Hailing portCLAYTON, NY
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 30 January 2026 · expires 31 January 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it73 - Simplified, Net Ton
73 - Simplified, Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDJ6214MMSI 367795520 · active · compulsorily equipped · granted 20 June 2017, expires 20 June 2027
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 41

15 September 2025 Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Unit Thousand Islands · USCG Great Lakes District (CGD-GL) · Activity 8235037
13 September 2025 Type not recorded
No type recorded · Marine Safety Unit Thousand Islands · USCG Great Lakes District (CGD-GL) · Activity 8234939
12 June 2024 Annual Inspection
Physical examination · Marine Safety Unit Thousand Islands · USCG Great Lakes District (CGD-GL) · Activity 7932127
22 June 2023 Annual Inspection
Physical examination · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 7720109
13 June 2022 Deficiency Check · COI Inspection
Physical examination · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 7465560
28 March 2022 Drydock Exam
Physical examination · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 7420196
17 March 2022 Administrative Inspection · Construction Oversight · Plan Review "T" Boat
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7413368
28 September 2021 Construction Oversight · Deadweight Survey
Physical examination · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 7417047
25 May 2021 Annual Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 7206610
5 April 2021 Excursion Permit
Administrative · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 7169438
19 December 2019 Administrative Inspection · Excursion Permit
Administrative · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 6889803
11 July 2019 Type not recorded
No type recorded · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 6746946
10 July 2019 Examination of Repairs · Damage Survey · Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 6743893
9 July 2019 Type not recorded
No type recorded · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 6776930
19 June 2018 DAPI Audit · Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 6449591
12 June 2018 Administrative Inspection
Administrative · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 6442531
11 June 2018 Examination of Repairs · In-Service Inspection · Administrative Inspection
Physical examination · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 6440614
23 January 2017 Plan Review "T" Boat · Deficiency Check · Administrative Inspection · Examination of Repairs · Hull Examination · COI Inspection
Physical examination · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 6075469
28 June 2016 Drydock Exam · Internal Structural Exam
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 5930603
29 May 2012 Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 4327086
11 May 2012 Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 4308250
5 October 2010 Damage Survey
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3863613
4 October 2010 Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3864495
7 July 2009 Administrative Inspection
Administrative · Marine Safety Center (MSC) · Activity 3526627
23 March 2009 Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3438332
31 October 2008 Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3354869
19 September 2007 Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3060352
25 September 2006 Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2786298
22 September 2006 Damage Survey
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2784667
21 September 2006 Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2784724
5 July 2006 COI Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2702174
2 June 2006 Deficiency Check
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2668735
26 April 2006 Hull Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2638777
2 May 2005 Annual Inspection · Deficiency Check
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2381740
29 September 2004 Annual Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 2237217
22 September 2003 Annual Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1910840
28 October 2002 Annual Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1697430
9 July 2002 In-Service Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1643910
12 February 2002 Simplified Stability Test
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1486308
25 July 2001 Administrative
Administrative · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1068856
3 July 2001 Initial Certification · Plan Review "T" Boat · Hull Examination
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1065955

Deficiency record · 61

13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 15 September 2025 Resolved
Repairs or alterations to the hull, machinery, or equipment that affect the safety of the vessel must not be made without the approval of the cognizant OCMI, except during an emergency...Repairs or alterations that affect the safety of the vessel include damage repair or replacement, other than replacement in kind, of propulsion and power supply systems. The OCMI may require an inspection and testing whenever a repair or alteration is undertaken. Major damage was sustained to RIVER LOOP's starboard outboard engine, necessitating replacement of the lower unit. The vessel is therefore subject to inspection and testing by the Coast Guard to ensure adequacy of repairs and vessel safety.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 September 2025
Resolution: Satisfactory propulsion test in foreward and reverse witnessed for STBD outboard following lower unit replacement. All sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 22 June 2023 Resolved
Fuel lines on starboard engine are deteriating from sun exposure. Need to be replaced.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 July 2023
Resolved 8 July 2023
Resolution: Fuel lines on Starboard engine have been replaced in kind. All sat
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 22 June 2023 Resolved
Ring Life buoy has deteriorated due to sun exposure and needs to be replaced.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 July 2023
Resolved 8 July 2023
Resolution: New life ring buoy has been placed into service. All sat
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 22 June 2023 Resolved
Handrail on port bow is separated from the deck. Handrail needs to be secured properly to withstand 200 pounds point load.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 July 2023
Resolved 8 July 2023
Resolution: Handrail has been repaired to withstand 200 lbs point load. All sat.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 22 June 2023 Resolved
Portable fuel tanks on stern of vessel need to be removed.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 8 July 2023
Resolution: Portable fuel tanks have been removed. All sat
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 22 June 2023 Resolved
First aid kit found with expired aspirin, vessel owner replaced with new.
Action required: 10 - Deficiency Rectified
Resolved 22 June 2023
Resolution: Owner replaced Aspirin with new.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 22 June 2023 Resolved
Starting batteries for engines, center engine battery box strap was too short to secure properly, replaced with new. Port engine battery bow missing battery box cover, replaced with new. Starboard engine starting battery found with loose terminals, terminals tightened by Captain.
Action required: 10 - Deficiency Rectified
Resolved 22 June 2023
Resolution: Replaced with new.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 13 June 2022 Resolved
Found dead end wire under operating station. Remove dead end wire.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 June 2022
Resolved 14 June 2022
Resolution: Dead end wire was removed.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 13 June 2022 Resolved
Found batteries on stern unsecured to vessel and moving freely. Secure batteries to ensure they do not move during normal operation of the vessel.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 June 2022
Resolved 14 June 2022
Resolution: Batteries were secured to deck of vessel to prevent shifting during vessel operation.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 13 June 2022 Resolved
Found stbd side battery with cover too small and standing water in container. Remove water and replace with correct sized battery cover.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 June 2022
Resolved 14 June 2022
Resolution: Cover was replaced with one of appropriate size.
02 - Structural Conditions › N/A - No Subsystem › Closing devices/watertight doors
Issued 13 June 2022 Resolved
Lock on rail on bow of vessel with gate opening does not secure the rail. Replace lock on rail.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 June 2022
Resolved 28 June 2022
Resolution: Crew installed new door latch.
08 - Alarms › N/A - No Subsystem › Machinery controls alarm
Issued 2 June 2021 Resolved
All machinery and equipment must be installed and miantained in such a manner as to afford adequate protection from machinery failure. The port engine low lube oil pressure alarm sounds when vessel is in idle position at random intervals. Check associated wiring and provide technician's report from examination of the alarm and associated equipment.
Condition: Design Flaw
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 July 2021
Resolved 19 July 2021
Resolution: Owner provided tech report. Alarm wiring was loose and repaired to the satisfaction of the Coast Guard.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 11 July 2019 Resolved
Stbd outboard engine steering ram bracket to engine was broken. According to Master and Owner, casualty happened while docking at Clayton Island Tours dock on 09Jul2019 ooa 2055.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 11 July 2019
Resolution: Owner repaired/replaced stbd engine steering ram bracket to the engine. Tested satisfactory.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 11 July 2019 Resolved
First aid kit on board was not USCG approved.
Condition: Invalid
Action required: 705 - Other - as specified
Due 25 July 2019
Resolved 31 July 2019
Resolution: Owner procured new first aid kit and placed aboard vessel.
10 - Safety of Navigation › N/A - No Subsystem › Magnetic compass
Issued 11 July 2019 Resolved
Magnetic compass light was found disconnected.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 31 July 2019
Resolution: Owner reconnected electrical wire for the compass light.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 11 July 2019 Resolved
Float light battery was the wrong type. Found spring terminals, screw type terminals are required. Daytime ops only.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 11 July 2019
Resolution: Deficiency was corrected on the spot.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 11 July 2019 Resolved
Dead-end positive battery cable under operating station. Cable must be removed or placed inside electrical marine type junction box.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 25 July 2019
Resolved 31 July 2019
Resolution: Dead-end cable has been placed in a weather tight junction box.
Navigation › Piloting/Steering › Inland Navigation Rules
Issued 19 June 2018 Resolved
Vessel did not have Inland Navigation Rules onboard.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 25 June 2018
Resolved 19 June 2018
Resolution: Vessel owner found NavRules and placed onbaord vessel.
Lifesaving › Hand Flares › Expired
Issued 19 June 2018 Resolved
All distress signals onbaord were found to be expired.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 19 June 2018
Resolved 19 June 2018
Resolution: Vessel owner purchased the proper distress signals and placed onboard.
Construction/Loadline › Hull › Weld
Issued 28 June 2016 Resolved
All welds below the water line are excessively corroded and washed out. Renew as original.
Action required: 701 - Prior to carriage of passengers/cargo
Due 29 June 2016
Resolved 3 April 2017
Resolution: Welds were ground out and rewelded. Pontoons were pressure tested (2 psi) and repairs soap tested. Leaking areas ground out, repaired and retested.
Construction/Loadline › Hull › Hull Plating
Issued 28 June 2016 Resolved
Bottom and side plating for both pontoons are excessively corroded. Noted excessive pitting throughout including both port and starboard inside sections aft of the rake. Noted interior plating corroded using borescope.
Action required: 701 - Prior to carriage of passengers/cargo
Due 29 June 2016
Resolved 3 April 2017
Resolution: Bottom and side plating cleaned and pits measured and marked for repair. Three compartments opened per pontoon and inspected. Interior corrosion was noted and repaired as per the inspection narrative.
Engineering › Gas Turbine (auxiliary) › Mounting
Issued 28 June 2016 Resolved
Excessive corrosion noted on both outboard mounts and associated support system.
Action required: 701 - Prior to carriage of passengers/cargo
Due 29 June 2016
Resolved 3 April 2017
Resolution: Both transom plates removed and renewed with 1/2" plate. New brackets installed in the aft compartments and new mounting brackets installed (drawing in documents).
Electrical › Electrical Distribution System (service) › Neutral Ground
Issued 28 June 2016 Resolved
Provide report showing the source of stray current problem and resolution.
Action required: 701 - Prior to carriage of passengers/cargo
Due 29 June 2016
Resolved 3 April 2017
Resolution: Traced electrical system wiring and found three direct grounds to the vessel hull in the 110 volt system for the flood lights. The flood lights and wiring were removed from teh vessel.
Construction/Loadline › Hull › Side Shell
Issued 28 June 2016 Resolved
Vessel is to be dry-docked to conduct an out of water hull exam. Issued 23 March 2016.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 June 2016
Resolved 3 April 2017
Resolution: Vessel out of the water, inspected and repaired during the 2016/17 winter.
Construction/Loadline › Hull › Side Shell
Issued 28 June 2016 Resolved
Prepare hull for full inspection, clean to bare metal. Issued 28 June 2016.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 June 2016
Resolved 3 April 2017
Resolution: Hull cleaned and repaired.
Electrical › Electric Generation Source (service) › Conductor
Issued 28 June 2016 Resolved
Electrical system (110 v) is not suitabler for marine service. Disconnect/remove until USCG approved. Issued 28 June 2016.
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 June 2016
Resolved 15 June 2017
Resolution: The starboard generator has been rebuilt and was reinstalled on the transom. Electical system was rewired and found to be in satisfactory condition.
Construction/Loadline › Hull › Hull Plating
Issued 5 October 2010 Resolved
Issued a 835 not to carry passengers until damage survey could be conducted by CG Marine Inspector
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 13 October 2010
Resolution: got vessel underway full power for 15 min, all engine operations SAT
Stability › Incline Test › General
Issued 23 March 2009 Resolved
Not to carry more than 49 passengers and 2 crew until damage stability calculations are submitted and approved by MSC.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Due 20 January 2010
Resolved 10 August 2010
Resolution: Issued new COI reflecting 49 passengers and 2 crew, cleared 835.
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 19 September 2007 Resolved
Properly label all Child Life Jackets with vessel's name and stow Child Life Jackets separated from Adult Life Jackets and label stowage bins.
Condition: Improper Installation
Due 26 September 2007
Resolved 28 September 2007
Resolution: Witness properly labeled child life jackets in "Child Life Jacket" labeled stowage bins.
Lifesaving › Lifejacket/PFD (General) › Marking
Issued 19 September 2007 Resolved
Life jackets did not have the name of the vessel marked as required in 46 CFR 185.604(b) Additional children’s PFD’s were not stowed in a location that is appropriately marked and separated from adult life jackets as required in 46 CFR 180.78(a)(5).
Condition: Unknown
Due 26 September 2007
Resolved 28 September 2007
Resolution: Witnessed all children’s PFDs w/ proper labels and they were all stowed in properly marked locations.
Construction/Loadline › Hull › Hull Plating
Issued 22 September 2006 Resolved
Prove integrity of vessels hulls by making available for inspection of possible damage caused by grounding. To the satisfaction of the attending Marine Inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 September 2006
Resolution: Witnessed satisfactory diver inspection.
Navigation › Piloting/Steering › Tide/Tidal Current Tables
Issued 5 July 2006 Resolved
Provide current copy of tidal current tabels, & Navigation Rules.
Action required: 705 - Other - as specified
Due 20 July 2006
Resolved 7 July 2006
Resolution: Witnessed current tidal current tabels & Nav Rules.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Service
Issued 5 July 2006 Resolved
Prove 6 year service of fire extinguishers.
Action required: 701 - Prior to carriage of passengers/cargo
Due 20 July 2006
Resolved 7 July 2006
Resolution: Owner provided all new fire extinguishers, all sat.
Electrical › Electric Supply System (service) › Overcurrent Device
Issued 5 July 2006 Resolved
Label 110V breakers prior to using 110V power.
Action required: 705 - Other - as specified
Due 20 July 2006
Resolved 7 July 2006
Resolution: Witnessed labeling of breakers.
Electrical › Electric Supply System (service) › Cable
Issued 5 July 2006 Resolved
Repair port engine wiring connections.
Action required: 701 - Prior to carriage of passengers/cargo
Due 20 July 2006
Resolved 7 July 2006
Resolution: Witnessed proper electrical connections.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 26 April 2006 Resolved
Repair broken deck rail, port forward corner where weld is broken.
Action required: 701 - Prior to carriage of passengers/cargo
Due 26 May 2006
Resolved 2 June 2006
Resolution: Rail was bolted.
Engineering › Fuel Oil Service System › Hose
Issued 26 April 2006 Resolved
Replace fuel hose port side with CG approved.
Due 26 May 2006
Resolved 2 June 2006
Resolution: Witnessed new CG B2 hose.
Engineering › Fuel Oil Service System › Hose
Issued 26 April 2006 Resolved
Install doubel hose clamps on all fuel hoses.
Due 26 May 2006
Resolved 2 June 2006
Resolution: Witnessed double hose clamps on all fuel lines.
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 2 May 2005 Resolved
Properly label life jacket boxes.
Due 2 June 2005
Resolved 16 May 2005
Resolution: Boxes labeled.
Engineering › Fuel Oil Storage/Transfer System › Hose
Issued 2 May 2005 Resolved
Provide proper fuel hose.
Due 2 June 2005
Resolved 16 May 2005
Resolution: Provide hose.
Electrical › Electric Supply System (service) › Battery Installation
Issued 2 May 2005 Resolved
Properly clean batteries and provide strap for battery box.
Due 2 June 2005
Resolved 16 May 2005
Resolution: Cleaned batteries and provided strap.
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 2 May 2005 Resolved
Provide documentation.
Due 2 June 2005
Resolved 16 May 2005
Resolution: Provided documentation.
Electrical › Electrical Distribution System (service) › Cable
Issued 2 May 2005 Resolved
Remove dead end cable above back door.
Due 2 June 2005
Resolved 16 May 2005
Resolution: Removed cable.
Operations/Management › Drills/Instruction › Fire
Issued 29 September 2004 Resolved
Relocate Emergency Procedures Placard.
Condition: Improper Installation
Due 29 October 2004
Resolved 9 November 2004
Resolution: Relocated placard.
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 29 September 2004 Resolved
Provide proper life jacket placard and relocate.
Condition: Improper Installation
Due 9 October 2004
Resolved 9 November 2004
Resolution: Provide and relocated.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Mounting Bracket
Issued 29 September 2004 Resolved
Provide proper size fire extinguisher bracket.
Condition: Improper Installation
Due 29 October 2004
Resolved 9 November 2004
Resolution: Provided bracket.
Engineering › Fuel Oil Storage/Transfer System › Gauge
Issued 29 September 2004 Resolved
Replace gas tank gauge.
Condition: Improper/Lack of Maintenance
Due 29 October 2004
Resolved 9 November 2004
Resolution: Replaced gauge.
Lifesaving › Lifejacket/PFD (General)
Issued 28 October 2002 Resolved
Re-lable or re-stow life jacket stowage to reflect actual placement of all life jackets on board vessel. LEGACY COMPONENT DESC: Storage
Condition: Improper Installation
Due 28 November 2002
Resolved 26 November 2002
Resolution: Re stowed and re labeled life jackets.
Navigation › Piloting/Steering
Issued 28 October 2002 Resolved
Provide tide information for vessel "tide table". LEGACY COMPONENT DESC: Tide/Tidal Current Tables
Condition: Unknown
Due 28 November 2002
Resolved 26 November 2002
Resolution: Tide table was provided.
Operations/Management › Drills/Instruction
Issued 28 October 2002 Resolved
Provide proof of crew training "recorded training for this operating season 46CFR185.420. LEGACY COMPONENT DESC: Logs and record keeping
Condition: Unknown
Due 28 November 2002
Resolved 26 November 2002
Resolution: Provided proof of crew training.
Operations/Management › Navigation Safety
Issued 28 October 2002 Resolved
Provide bridge log "current record" for the 2002 operating season to date. LEGACY COMPONENT DESC: log book
Condition: Unknown
Due 28 November 2002
Resolved 26 November 2002
Resolution: Provided bridge log.
Operations/Management › FireFighting
Issued 28 October 2002 Resolved
Provide proof of monthy checks for 2002 operating season for life saving and fire fighting equipment. LEGACY COMPONENT DESC: inspection record
Condition: Unknown
Due 28 November 2002
Resolved 26 November 2002
Resolution: Provided monthly check for life saving and fire fighting equipment.
Stability › Watertight Integrity
Issued 9 July 2002 Resolved
Prior to the vessel being placed in operation carrying more than six (06) passengers for hire, determine the cause of the vessels trim down by the stern excessively. Ensure stern compartments are watertight and free of water.
Condition: Unknown
Due 18 July 2002
Resolved 23 July 2002
Resolution: Vessel trim even. Compartments pumped and free of water.
Construction/Loadline › Penetrations › Bottom Plug
Issued 9 July 2002 Resolved
Provide repair to the port pontoon #3 and #4 compartment sounding plugs.
Condition: Improper/Lack of Maintenance
Due 18 July 2002
Resolved 12 July 2002
Resolution: Port pontoon #3 and #4 compatment sounding plugs replaced with new.
Engineering
Issued 3 July 2001 Resolved
SECURE OUTBOARD ENGINE CABLES.
Condition: Unknown
Due 10 July 2001
Resolved 1 August 2001
Lifesaving
Issued 3 July 2001 Resolved
RE-SECURE RAIL ON AFT DECK.
Condition: Unknown
Due 10 July 2001
Resolved 1 August 2001
Lifesaving
Issued 3 July 2001 Resolved
INSTALL NEW BRACKET RAIL ON AFT DECK AND REPLACE BROKEN BRACKET.
Condition: Unknown
Due 10 July 2001
Resolved 1 August 2001
Lifesaving
Issued 3 July 2001 Resolved
PROVIDE EMERGENCY BRODCAST PLACARD._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 10 July 2001
Resolved 1 August 2001
Fire Fighting
Issued 3 July 2001 Resolved
PROVIDE & INSTALL MOUNT FOR FIRE EXTINGUISHER.
Condition: Unknown
Due 10 July 2001
Resolved 1 August 2001
Lifesaving
Issued 3 July 2001 Resolved
PROVIDE EMERGENCY INSTRUCTION PLACARD.
Condition: Unknown
Due 10 July 2001
Resolved 1 August 2001
Construction/Loadline
Issued 3 July 2001 Resolved
PROVE WATERTIGHT INTEGRATY OF ENGINE MOUNT SPACE._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 1 August 2001
Resolved 1 August 2001

Casualty record · 5

21 September 2006Routine · role: Involved in a Marine Casualty · activity 2784724
4 October 2010Routine · role: Involved in a Marine Casualty · activity 3864495
9 July 2019Routine · role: Involved in a Marine Casualty · activity 6776930
11 July 2019Routine · role: Alleged Pollution Source · activity 6746946
13 September 2025Routine · role: Involved in a Marine Casualty · activity 8234939
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.