MAURY USCG vessel records Sign in
← All vessels

KOO WA SIK

KOO WA SIK is a 1988 passenger vessel (uninspected). The Coast Guard has recorded 30 inspections since 1988, most recently in June 2018, along with 28 deficiencies.

Records from 1988 to 2018. Most recent: inspection, 22 June 2018.

Built
1988
Last inspected
22 June 2018
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDA2425
290588
Flag
UNITED STATES
368436350
Maury page id
psix-290588

Inspections, by type

…with no type recorded6
Years with a record 15 calendar years (1988–2018)
The 30 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 8 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)36.6 ft × 12.0 ft × 5.5 ft
Registered tonnagegross 24 / net 19
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderMUNSON MFG. · EDMONDS, WA, UNITED STATES · built 1988
Hull materialAluminum
PropulsionGasoline Outboard
Hull shapeShip
Hull configurationNot recorded
Hailing portKILLISNOO HARBOR, AK
Trade endorsementsCoastwise, unrestricted, Fishery, Registry
DocumentationValid · issued 17 September 2025 · expires 30 September 2026
Service, as the file records itPassenger (Uninspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it24 - Simplified, Gross Ton
19 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDQ5627MMSI 368436350 · active · compulsorily equipped · granted 19 August 2025, expires 19 August 2035
WCE8301MMSI not assigned · expired · compulsorily equipped · granted 29 March 1994, cancelled 30 May 2004 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 30

22 June 2018 Uninspected Passenger Vessel
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 6851046
29 August 2008 Internal Structural Exam · Administrative Inspection · Hull Examination
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 3312462
1 July 2008 Type not recorded
No type recorded · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 3277155
26 June 2008 Annual Inspection
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 3249142
26 June 2008 Type not recorded
No type recorded · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 3249817
26 June 2008 DAPI Audit
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 3249960
25 June 2007 Annual Inspection · Deficiency Check
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 2973559
31 July 2006 Deficiency Check
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 2731644
5 June 2006 COI Inspection
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 2671237
24 May 2006 Hull Examination
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 2657681
30 January 2006 Administrative Inspection
Administrative · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 2576102
26 June 2004 Hull Examination · COI Inspection
Physical examination · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 2106150
18 June 2002 Deficiency Check
Physical examination · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 1632690
7 June 2002 Re-Inspection · Hull Examination
Physical examination · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 1629219
28 June 2001 Deficiency Check · Initial Certification
Physical examination · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 1382392
18 May 2001 Type not recorded
No type recorded · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 1376658
28 August 2000 Type not recorded
No type recorded · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 1473047
3 August 2000 Administrative
Administrative · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1470573
2 August 2000 Hull Examination
Physical examination · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 1068234
16 April 1999 Type not recorded
No type recorded · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 1411857
28 October 1996 Administrative
Administrative · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 855199
29 March 1995 Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1144379
19 May 1994 Re-Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1170537
21 April 1994 Hull Examination
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1167980
13 July 1993 COI Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 842434
3 May 1993 Hull Examination
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1354334
27 February 1990 Administrative
Administrative · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 907138
11 March 1988 Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1336352
18 February 1988 Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 894386
18 February 1988 Initial Certification · Hull Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1022883

Deficiency record · 28

Operations/Management › Drug and Alcohol Testing › Testing, Equipment
Issued 25 June 2007 Resolved
Provide (1) missing alcohol saliva test and include the existing Deckhand to the drug testing consortium.
Condition: Unknown
Action required: 705 - Other - as specified
Due 15 July 2007
Resolved 17 July 2007
Engineering › Lubricating Oil Service System › Gauge
Issued 25 June 2007 Resolved
Renew the hydraulic engine control gage located STBD side engine compartment.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 July 2007
Resolved 17 July 2007
Accommodation/Occupational Safety › Ventilation › General
Issued 25 June 2007 Resolved
Replace broken plexiglass located portside forward passenger area.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 15 July 2007
Resolved 17 July 2007
Navigation › Piloting/Steering › Marine Charts
Issued 25 June 2007 Resolved
Update onboard marine charts with the latest notice to mariners, last updated on the record: 1999.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 July 2007
Resolved 17 July 2007
Engineering › Fuel Oil Service System › Valve
Issued 25 June 2007 Resolved
Make the emergency F.O. valve for the F.O. tanks to close properly shut.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 15 July 2007
Resolved 17 July 2007
Operations/Management › Equipment Service/Testing › EPIRB
Issued 5 June 2006 Resolved
Vessel restricted carrying passengers until required EPIRB is onboard., tested, & properly stowed by Master. Notify [name withheld] prior to carrying passengers proper operation & stowage of the EPIRB. Master sends with attached sign letter to Sector Juneau via email, FAX, or a phone call to the EPIRB condition prior to resuming service.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 31 July 2006
Resolved 31 July 2006
Resolution: Received information via Facsimile from Master EPIRB onboard & functioning, sat.
Construction/Loadline › Hull › Bottom Plating
Issued 24 May 2006 Resolved
Re-weld area aft STBD bottom hull, penny size.
Condition: Improper Installation
Due 25 May 2006
Resolved 25 May 2006
Resolution: Done, smooth out, sat.
Documentation › Certificates/Documents › Stability Letter
Issued 24 May 2006 Resolved
Post vessel's Stability Letter.
Condition: Unknown
Action required: 705 - Other - as specified
Due 30 June 2006
Resolved 7 June 2006
Resolution: Done, sat.
Engineering › Fuel Oil Service System › Filter
Issued 24 May 2006 Resolved
Install missing metal shields on Racor Filters & replace plastic drain petcocks with metal valves with plugs.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 30 June 2006
Resolved 14 July 2006
Resolution: Done
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 24 May 2006 Resolved
Install machinery guards in hydraulic pump STBD main engine.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 30 June 2006
Resolved 7 June 2006
Resolution: Completed, sat.
Lifesaving › Inflatable Liferafts › Servicing
Issued 24 May 2006 Resolved
Send out liferaft for servicing, last service: May 2004.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 June 2006
Resolved 14 July 2006
Resolution: Done
Lifesaving › Inflatable Liferafts › Hydrostatic Release Unit
Issued 24 May 2006 Resolved
Renew expired hydro-static release for the liferaft, HAMMER.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 June 2006
Resolved 14 July 2006
Resolution: Done
Fire Fighting › Fixed Halon Fire Extinguishing System › Tanks
Issued 24 May 2006 Resolved
Service maintenance all fire extinguishers & the fixed Halon system. Last service on tag: 2002.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 June 2006
Resolved 14 July 2006
Resolution: Done
Engineering › Fuel Oil Service System › Vent Pipe
Issued 24 May 2006 Resolved
Install screens on Port & STARBOARD fuel oil vents aft lazarette in a way of machinery air vents.
Condition: Unknown
Action required: 705 - Other - as specified
Due 30 June 2006
Resolved 7 June 2006
Resolution: Done, sat.
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 24 May 2006 Resolved
Rename (Stencil) vessel's name & renew retro-reflective tape on the ring buoy.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 June 2006
Resolved 7 June 2006
Resolution: Done, sat.
Engineering › Bilge Water Management System › Pump
Issued 29 June 2004 Resolved
Replace the portable hand bilge pump with a working model having a longer reach.
Action required: 701 - Prior to carriage of passengers/cargo
Due 29 July 2004
Resolved 14 July 2006
Resolution: Done
Pollution Prevention/Response › Prevention Equipment › Sewage System Piping
Issued 29 June 2004 Resolved
Replace the damaged section of the sewage hose.
Due 29 July 2004
Resolved 25 May 2006
Resolution: Done, sat.
Pollution Prevention/Response › Prevention Equipment › Sewage System Piping
Issued 29 June 2004 Resolved
Provide proper ventilation for the sewage holding tank (i.e. must vent overboard and well above the waterline.)
Due 29 July 2004
Resolved 25 May 2006
Resolution: Done, sat.
Engineering › Lubricating Oil Service System › Gauge
Issued 29 June 2004 Resolved
Troubleshoot the malfunctioning oil pressure monitoring system for the port main engine.
Due 29 July 2004
Resolved 7 June 2006
Resolution: Done, sat.
Engineering › Fuel Oil Storage/Transfer System › Vent Pipe
Issued 29 June 2004 Resolved
Replace ventilation system piping for the forward fuel tank to meet Title 46 CFR 182.450.
Due 29 July 2004
Resolved 25 May 2006
Resolution: Done, sat.
Engineering › Bilge Water Management System
Issued 7 June 2002 Resolved
Repair/Replace inoperable float switch on engine compartment electric bilge pump. LEGACY COMPONENT DESC: Pump
Condition: Unknown
Due 7 July 2002
Resolved 18 June 2002
Resolution: Recieved affidavit and purchase order by fax for repair of float switch.
Accommodation/Occupational Safety › Medical/First Aid
Issued 7 June 2002 Resolved
Replace expired first aid items. LEGACY COMPONENT DESC: Medicine Chest
Condition: Unknown
Due 7 July 2002
Resolved 18 June 2002
Resolution: Received faxed affidavit and reciept for purchase of new first aid items.
Accommodation/Occupational Safety
Issued 28 June 2001 Resolved
PROVIDE 1-1/2" MINIMUM VENTILATION DUCTING FOR FORWARD FUEL TANK COMPARTMENT.
Condition: Unknown
Due 28 July 2001
Resolved 26 September 2001
Navigation
Issued 28 June 2001 Resolved
REPLACE STEERING CROSSBAR WITH SPECIFIED TYPE.
Condition: Unknown
Due 28 July 2001
Resolved 26 September 2001
Navigation
Issued 19 May 1994 Resolved
PROVIDE A CURRENT MAGNETIC COMPASS DEVIATION TABLE.
Condition: Unknown
Due 19 May 1994
Resolved 19 May 1994
Documentation
Issued 13 July 1993 Resolved
VESSEL IS RESTRICTED TO NOT MORE THAN 1,000 FEET FROM SHORE UNTIL A CURRENTFCC SAFETY EQUIPMENT CERTIFICATE IS PROVIDED.
Condition: Unknown
Due 13 July 1993
Resolved 13 July 1993
Unknown
Issued 18 February 1988 Resolved
MOUNT EMERGENCY EXIT KEEP CLEAR SIGNS ON EXTERIOR FRONT POP OUT WINDOWS PORT AND STARBOARD SIDE.
Condition: Unknown
Due 18 February 1988
Resolved 18 February 1988
Construction/Loadline
Issued 18 February 1988 Resolved
PROVIDE VESSELS ANCHOR AND ASSOCIATED LINE/CHAIN.
Condition: Unknown
Due 18 February 1988
Resolved 18 February 1988

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.