MAURY USCG vessel records Sign in
← All vessels

SEXY WALRUS

SEXY WALRUS is a 1987 passenger vessel (inspected). The Coast Guard has recorded 65 inspections since 1987, most recently in February 2026, along with 119 deficiencies — 1 with no resolution recorded —, 1 operational control and 3 casualty investigations between 2002 and 2012.

Records from 1987 to 2026. Most recent: inspection, 27 February 2026.

Built
1987
Last inspected
27 February 2026
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDK4447
290693
Flag
UNITED STATES
367354960, 368460240
Maury page id
psix-290693

Inspections, by type

…with no type recorded6
Years with a record 36 calendar years (1987–2026)
The 65 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)36.2 ft × 12.5 ft × 5.7 ft
Registered tonnagegross 15 / net 10
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderDELTA BOATS INC · CAPE CANAVERAL, FL, UNITED STATES · built 1987
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portBOYTON BEACH, FL
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 13 February 2026 · expires 28 February 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it15 - Regulatory (Subpart C or D), Gross Ton
10 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDQ8243MMSI 368460240 · active · compulsorily equipped · granted 4 March 2026, expires 4 March 2036
WDK4447MMSI 367354960 · active · compulsorily equipped · granted 17 August 2018, expires 17 August 2028
WDE4568MMSI 367354960 · expired · compulsorily equipped · granted 8 May 2008, cancelled 14 July 2018
WDB6135MMSI 366918770 · expired · compulsorily equipped · granted 9 January 2004, cancelled 15 March 2014 · licensed under a name not among this hull’s recorded names (not shown)
WCR5794MMSI not assigned · expired · compulsorily equipped · granted 15 May 1995, cancelled 16 July 2005 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspected as a tow unit · 1

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

GOODY III Passenger (Inspected) · MISLE 43779 · 12 December 1995 · activity 131916

Inspection history · 65

27 February 2026 Internal Structural Exam · Administrative Inspection · Hull Examination
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 8317735
29 September 2025 Deficiency Check · Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 8243454
4 October 2024 Annual Inspection · Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 8014556
17 April 2024 Administrative Inspection · Hull Examination · Internal Structural Exam · Examination of Repairs
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 7896791
27 July 2023 Type not recorded
No type recorded · Station Lake Worth Inlet · USCG Southeast District (CGD-SE) · Activity 7755007
21 June 2023 COI Inspection · Deficiency Check · Administrative Inspection · DAPI Audit
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 7720283
6 October 2022 Annual Inspection · Administrative Inspection · Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7572253
7 April 2022 Internal Structural Exam · Drydock Exam · Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 7426331
8 September 2021 Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 7307160
15 October 2020 Annual Inspection
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 7077623
20 May 2020 Drydock Exam · Deficiency Check · Internal Structural Exam
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 6956439
24 September 2019 Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 6819511
12 July 2018 DAPI Audit · Deficiency Check · COI Inspection
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 6475901
8 May 2018 Drydock Exam · Deficiency Check · Internal Structural Exam
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 6433865
10 October 2017 DAPI Audit · Annual Inspection
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 6284404
11 October 2016 Annual Inspection · DAPI Audit
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 6019767
10 May 2016 Internal Structural Exam · Drydock Exam · Deficiency Check
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 5873213
19 April 2016 DAPI Audit
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 5858276
14 October 2015 Annual Inspection · DAPI Audit
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 5742219
15 October 2014 DAPI Audit · Annual Inspection
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 5005718
13 May 2014 Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 4857474
22 May 2012 Hull Examination · Internal Structural Exam
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 4318697
2 December 2011 Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 4200143
18 October 2010 Annual Inspection
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 3871870
6 July 2009 Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3525375
24 April 2008 Initial Certification · Hull Examination · Deficiency Check · Simplified Stability Test
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3192050
8 March 2007 Administrative Inspection
Administrative · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 2884184
20 April 2005 Annual Inspection · Hull Examination
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 2339846
15 January 2004 COI Inspection
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 1984579
27 May 2003 Administrative Inspection
Administrative · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1802679
14 April 2003 COI Inspection · Hull Examination · MARPOL Annex V Examination
Physical examination · MSD MARATHON · USCG Southeast District (CGD-SE) · Activity 1774073
10 October 2002 Administrative Inspection
Administrative · MSD MARATHON · USCG Southeast District (CGD-SE) · Activity 1688035
14 March 2002 Type not recorded
No type recorded · MSD MARATHON · USCG Southeast District (CGD-SE) · Activity 1494443
11 October 2001 Re-Inspection · MARPOL Annex V Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1450687
20 August 2001 Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1376735
4 October 2000 MARPOL Annex V Examination · Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1429430
5 October 1999 Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1194502
16 September 1999 MARPOL Annex V Examination · COI Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1384253
24 August 1999 Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1404825
3 November 1998 Re-Inspection · MARPOL Annex V Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1442771
21 October 1997 Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 777457
25 September 1997 Administrative
Administrative · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1114898
24 September 1997 Re-Inspection · MARPOL Annex V Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1114896
15 July 1997 Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1115702
5 October 1996 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 108626
5 October 1996 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 224784
20 September 1996 COI Inspection · MARPOL Annex V Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 960814
12 December 1995 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 131916
10 October 1995 Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 876124
26 September 1995 Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1187382
12 July 1995 Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1193102
17 May 1995 Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 924363
19 April 1995 Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1163393
21 September 1993 COI Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 839968
11 August 1993 Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 847048
25 September 1992 Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1263641
24 September 1991 Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1246570
22 August 1991 Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1248770
18 September 1990 COI Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 912057
15 May 1990 Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1240422
22 March 1990 Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 916733
24 July 1989 Administrative
Administrative · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 898481
10 January 1989 Re-Inspection · Hull Examination · Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1209024
29 September 1987 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1036301
25 September 1987 Initial Certification
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1316591

Deficiency record · 119

13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 27 February 2026 No resolution recorded
Repairs or alterations to the hull, or equipment that affect the safety of the vessel must not be made without the approval of the [name withheld] is in the process of installing stern thruster without prior authorization. Approval required prior to completing installation and using equipment.
Condition: Improper Installation
Action required: 705 - Other - as specified
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 29 September 2025 Resolved
A vessel on which a pre-engineered extinguishing system is installed must have the following equipment at the operating station: An audible alarm that sounds upon discharge.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 2 October 2025
Resolution: Bezel replaced.
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Other (Conditions of employment)
Issued 4 October 2024 Resolved
Marine employers shall establish programs for the chemical testing for dangerous drugs on a random basis of crewmembers on inspected vessels. Current enrollment in random drug testing program not on board.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 October 2024
Resolution: Provided.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 4 October 2024 Resolved
A vessel must carry a minimum of one life buoy. Life buoy grab line is deteriorated and buoy is missing retro-reflective tape.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 October 2024
Resolution: Replaced.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 4 October 2024 Resolved
A visual and audible alarm must be provided at the operating station. Laz high level alarm indicator is inoperable.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 October 2024
Resolution: Repaired and tested.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 4 October 2024 Resolved
A visual indicator must be provided at the operating station to indicate when any automatic bilge pump is operating. Indicator inoperable.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 October 2024
Resolved 17 October 2024
Resolution: Repaired and tested.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 4 October 2024 Resolved
As appropriate, a vessel must carry adequate and up-to-date: U.S. Coast Pilot, Tides table, Currents Table. Coast pilot, tides and currents tables missing.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 October 2024
Resolved 17 October 2024
Resolution: Provided.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 4 October 2024 Resolved
A vessel not required to have a fire pump must have at least three 2.5 gallon buckets. Vessel had three 5 gallon buckets.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 October 2024
Resolved 17 October 2024
Resolution: Provided.
04 - Emergency Systems › N/A - No Subsystem › Muster list
Issued 4 October 2024 Resolved
The master of a vessel will have mounted at the operating station, emergency instructions containing actions to be taken in the event of a fire, heavy weather, or man overboard condictions. Emergency instructions not mounted.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 October 2024
Resolved 17 October 2024
Resolution: Posted.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 4 October 2024 Resolved
Provisions must be made for closing all supply duct cowls or scoops and exhaust discharge opennings for a space protected by a fixed gas extinguishing system. Port supply duct cover for E/R is missing.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 October 2024
Resolved 17 October 2024
Resolution: Installed.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 4 October 2024 Resolved
Each connection to a conductor must be made within an enclosure. Dead end wires found in Fuel tank compartment.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 October 2024
Resolved 17 October 2024
Resolution: Removed.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 4 October 2024 Resolved
At each inspection the owner shall be prepared to have the vessel ready for inspection of the hull structure including inspection of all watertight closures. 02 sideshell openings on port side in fuel tank compartment do not have valves or are not capped.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 October 2024
Resolved 17 October 2024
Resolution: Capped.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 4 October 2024 Resolved
The master of the vessel shall ensure that each EPIRB must be tested monthly. The EPIRB test shall be logged or otherwise documented.
Condition: Invalid
Action required: 10 - Deficiency Rectified
Resolved 4 October 2024
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 6 July 2023 Resolved
On a vessel of at least 26’ in length a visual and audible alarm must be provided at the operating station to indicate a high water level in each of the following normally unmanned spaces: a machinery space
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 13 July 2023
Resolution: Hi water alarm now operates as required.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Cargo & other hatchways
Issued 6 July 2023 Resolved
A hatch cover must: be attached to the hatch frame or coming by hinges, captive chains, or other devices of substantial strength to prevent its loss.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 13 July 2023
Resolution: metallic lanyards now attached to frame and hatch.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 6 October 2022 Resolved
Provision shall be made by means of plugs, covers, etc. to prevent the admission of air into the space protected. Seal all bulkhead penetrations that allow air into the engine room space. 46 CFR 181.20-35
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 October 2022
Resolved 11 October 2022
Resolution: Photos received.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 6 October 2022 Resolved
At least one ring life buoy must be fitted with a lifeline. Lifeline on the vessel's only ring life buoy was broken. 46 CFR 180.70(c)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 October 2022
Resolved 11 October 2022
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 14 April 2022 Resolved
Numerous voids found on the exterior hull laminate while conducting hull soundings. Make repairs to marked areas prior to credit dry-dock. 46 CFR 176.610
Action required: 705 - Other - as specified
Resolved 15 April 2022
Resolution: Repairs completed SAT.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 14 April 2022 Resolved
Hose connecting fuel fill to the fuel tank is rotted and requires replacement. Replace this section of hose prior to credit dry-dock. 46 CFR 182.720
Action required: 705 - Other - as specified
Resolved 15 April 2022
Resolution: Hose replaced.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 27 May 2020 Resolved
Blister found on hull on starboard side aft of pilot house. Blister to be ground down, dried and repaired to the satisfaction of marine inspector prior to credit dry-dock. 46 CFR 176.610
Action required: 705 - Other - as specified
Resolved 29 May 2020
Resolution: Repair completed SAT.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 27 May 2020 Resolved
Repair or replace wasted and seized submersible electrical bilge pump valves at hull penetrations in all spaces prior to credit dry-dock. 46 CFR 182.520(e)(7)
Action required: 705 - Other - as specified
Resolved 29 May 2020
Resolution: Valves replaced.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 2 October 2019 Resolved
Main engine sea water strainer and sea water flexible hoses not secured causing a higher risk of engine room flooding. Secure strainer and hoses prior to carrying passengers. 46 CFR 182.420
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 4 October 2019
Resolution: Engine sea water strainer assembly and hoses secured SAT.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 1 October 2019 Resolved
Diesel fuel leak found in engine room at an unapproved type hose clamp connection between fuel hoses. Remove leaking connection between hoses prior to operating propulsion engine. 46 CFR 182.455
Action required: 17 - Rectify deficiencies prior to departure
Resolved 1 October 2019
Resolution: Leaking connection removed. Solid hose installed between filters.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 1 October 2019 Resolved
Fuel system flexible hose lengths are longer than 30" but not SAE J-1942 with SAE J-1475 fittings. Replace with approved type hoses and fittings prior to carrying passengers. 46 CFR 182.72(e)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 4 October 2019
Resolution: Approved hoses and fitting installed SAT.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 1 October 2019 Resolved
Main engine through hull sea water supply valve handle wasted. Unable to close valve. Repair valve prior to carrying passengers. 46 CFR 179.350(c)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 4 October 2019
Resolution: Valve handle replaced. Valve operates SAT.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 1 October 2019 Resolved
Main engine exhaust flexible hose in lazerette at transom is in non-serviceable condition causing a higher risk of flooding. Replace hose prior to carrying passengers. 46 CFR 182.430
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 4 October 2019
Resolution: Flex hose replaced SAT.
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 1 October 2019 Resolved
Emergency fuel shut off valve at fuel tank does not fully close. Adjust as needed to ensure valve closes completely when pulled remotely prior to carrying passengers. 46 CFR 182.455(b)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 4 October 2019
Resolution: Valve fully closes.
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 1 October 2019 Resolved
Conduct required drills to the satisfaction of marine inspector prior to carrying passngers. 46 CFR 185.518
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 4 October 2019
Resolution: Drills completed SAT.
09 - Working and Living Conditions › 092 - Working Conditions › Obstruction/slipping, etc.
Issued 1 October 2019 Resolved
Ladder rungs to flying bridge loose making it unsafe for crew to use. Secure ladder rungs to provide solid footing while transiting up and down ladder. 46 CFR 176.830
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 October 2019
Resolved 4 October 2019
Resolution: Ladder rungs secure.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 1 October 2019 Resolved
Provide an additional 4 visual distress signals. 46 CFR 180.68(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 October 2019
Resolved 4 October 2019
Resolution: 12 distress signals onboard.
09 - Working and Living Conditions › 092 - Working Conditions › Fitness for duty - intoxication
Issued 1 October 2019 Resolved
Provide proof of submittal of MIS report. 46 CFR 16.500
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 October 2019
Resolved 4 October 2019
Resolution: MIS report provided.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 12 July 2018 Resolved
Renew raw water supply hose from thru-hull to strainer.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 August 2018
Resolved 14 September 2018
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 12 July 2018 Resolved
Repair wasted exhaust.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 August 2018
Resolved 14 September 2018
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 12 July 2018 Resolved
Demonstrate ability to secure ventilation closures in closed position.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 August 2018
Resolved 14 September 2018
03 - Water/Weathertight Conditions › N/A - No Subsystem › Windows, sidescuttles and deadlights
Issued 12 July 2018 Resolved
Renew missing stbd cabin window.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 August 2018
Resolved 14 September 2018
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 12 July 2018 Resolved
Ensure accurate labels for PFD stowage.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 August 2018
Resolved 14 September 2018
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 12 July 2018 Resolved
Shorten waterlight lanyard to 3-6ft.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 August 2018
Resolved 14 September 2018
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 12 July 2018 Resolved
Install two working portable emergency lights.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 August 2018
Resolved 12 July 2018
01 - Certificates & Documentation › 011 - Ships Certificates › Cargo Ship Safety Radio (including exemption)
Issued 12 July 2018 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 August 2018
Resolved 14 September 2018
01 - Certificates & Documentation › 011 - Ships Certificates › Cargo Ship Safety Radio (including exemption)
Issued 12 July 2018 Resolved
Renew FCC Radio Safety Certificate
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 August 2018
Resolved 14 September 2018
11 - Life Saving Appliances › N/A - No Subsystem › On board training and instructions
Issued 12 July 2018 Resolved
Update/make entry into drill log, EPIRB testing & monthly portable fire ext. inspection.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 August 2018
Resolved 14 September 2018
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 12 July 2018 Resolved
Renew expired or missing items from first aid kit.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 August 2018
Resolved 14 September 2018
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 12 July 2018 Resolved
Install hatch lanyards on both watertight hatches.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 August 2018
Resolved 14 September 2018
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 12 July 2018 Resolved
Install locking devices on battery terminal connections.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 August 2018
Resolved 14 September 2018
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 12 July 2018 Resolved
Remove dead-end wiring hanging from overhead in accomodation space.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 August 2018
Resolved 14 September 2018
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 8 May 2018 Resolved
Replace cracked muffler.
Due 8 June 2018
Resolved 11 May 2018
Resolution: Owner installed new muffler.
Stability › Unintentional Flooding › General
Issued 10 May 2016 Resolved
Prove proper operation of head discharge through hull valve.
Due 31 May 2016
Resolved 10 May 2016
Resolution: Owner installed new valve.
Engineering › Shafting/Propeller Arrangements › Stern Tube
Issued 10 May 2016 Resolved
Re-new rotted shaft log hose.
Due 31 May 2016
Resolved 12 May 2016
Resolution: Owner has installed a new shaft log hose.
Engineering › Engine Controls (Electric/Electronic) › Linkage
Issued 10 May 2016 Resolved
Install e-clip on shift cable to prevent cable from coming off shifting lever.
Due 31 May 2016
Resolved 10 May 2016
Resolution: Owner installed new E-clip.
Communications › Alarms/Indicators › High Water Alarm
Issued 14 October 2015 Resolved
Prove proper operation of bilge alarm light in aft steering.
Action required: 705 - Other - as specified
Due 14 November 2015
Resolved 21 October 2015
Resolution: Proved proper operation of the bilge high water alarm light.
Engineering › Reduction Gearing/Clutches › Hose
Issued 14 October 2015 Resolved
Renew both red gear cooler hoses.
Action required: 705 - Other - as specified
Due 14 November 2015
Resolved 21 October 2015
Resolution: Replaced hoses.
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 14 October 2015 Resolved
Install retro tape on new life ring buoy.
Due 14 November 2015
Resolved 21 October 2015
Resolution: Installed retro tape on ring buoy.
Construction/Loadline › Hull › Hull Plating
Issued 24 April 2008 Resolved
Grind back all areas marked on FRP hull to 12:1 scarf.
Action required: 705 - Other - as specified
Resolved 24 June 2008
Construction/Loadline › Hull › Hull Plating
Issued 24 April 2008 Resolved
Provide lay-up schedual and materials used for hull repairs.
Action required: 705 - Other - as specified
Resolved 5 May 2008
Engineering › Shafting/Propeller Arrangements › Strut Bearing
Issued 24 April 2008 Resolved
Replace work cutlass bearing.
Action required: 705 - Other - as specified
Resolved 5 May 2008
Construction/Loadline › Structures › Transverse Bulkhead
Issued 24 April 2008 Resolved
Install 6 inch comming for foward weathertight hatch.
Action required: 705 - Other - as specified
Resolved 5 May 2008
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 24 April 2008 Resolved
Install deck railing aft IAW 46 CFR 177.900 (36" rail w/ 12" courses)
Action required: 705 - Other - as specified
Resolved 24 June 2008
Engineering › Steering Gear System › Rudder
Issued 24 April 2008 Resolved
Provide rudder stops for steering gear system.
Action required: 705 - Other - as specified
Resolved 5 May 2008
Accommodation/Occupational Safety › Ventilation › General
Issued 24 April 2008 Resolved
Provide means to secure engine room vent closures.
Action required: 705 - Other - as specified
Resolved 24 June 2008
Stability › Watertight Integrity › General
Issued 24 April 2008 Resolved
Make transverse bulkheads watertight (E/R fwd and aft bulkheads).
Action required: 705 - Other - as specified
Resolved 5 May 2008
Engineering › Fuel Oil Service System › Piping
Issued 24 April 2008 Resolved
Properly double clamp and ground fuel fill flex hose.
Action required: 705 - Other - as specified
Resolved 24 June 2008
Electrical › Electrical Distribution System (service) › Wiring
Issued 24 April 2008 Resolved
Properly attach grounding wire in steering gear compartment.
Action required: 705 - Other - as specified
Resolved 24 June 2008
Electrical › Electrical Distribution System (service) › Wiring
Issued 24 April 2008 Resolved
Remove or properly terminate all dead end wires.
Action required: 705 - Other - as specified
Resolved 14 July 2008
Lifesaving › Lifejacket/PFD (Type I) › Marking
Issued 24 April 2008 Resolved
Properly stencil all lifejackets and ring life buoys.
Action required: 705 - Other - as specified
Resolved 5 May 2008
Engineering › Bilge Water Management System › Piping
Issued 24 April 2008 Resolved
Double clamp all vital systems flex hoses.
Action required: 705 - Other - as specified
Resolved 24 June 2008
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Number
Issued 24 April 2008 Resolved
Provide proper amount of portable extinguishers per Table 181.500(a).
Action required: 705 - Other - as specified
Resolved 24 June 2008
Documentation › Certificates/Documents › FCC SSL
Issued 24 April 2008 Resolved
Provide valid FCC station license and safety radio certificate.
Action required: 705 - Other - as specified
Resolved 24 June 2008
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 24 April 2008 Resolved
Replace retro reflective tape on ring life buoy.
Action required: 705 - Other - as specified
Resolved 14 July 2008
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 24 April 2008 Resolved
Replace stbd nav light.
Action required: 705 - Other - as specified
Resolved 14 July 2008
Engineering › Bilge Water Management System › Valve
Issued 24 April 2008 Resolved
Proper label compartment location on ball valves for fixed bilge system.
Action required: 705 - Other - as specified
Resolved 14 July 2008
Communications › Alarms/Indicators › Bilge Alarm
Issued 24 April 2008 Resolved
Prove proper operation of bilge high level alarm for Aft E/R and Lazarette.
Action required: 705 - Other - as specified
Resolved 14 July 2008
Electrical › Electrical Distribution System (service) › Wiring
Issued 24 April 2008 Resolved
Update and submit for review and approval AC and DC plans.
Action required: 705 - Other - as specified
Resolved 14 July 2008
Engineering › Freshwater System (cylinder head cooling) › Hose
Issued 24 April 2008 Resolved
Repair worn flex hose for MDE raw water cooling system.
Action required: 705 - Other - as specified
Resolved 14 July 2008
Engineering › Bilge Water Management System › Piping
Issued 24 April 2008 Resolved
Replace broken clamp on bilge manifold piping.
Action required: 705 - Other - as specified
Resolved 14 July 2008
Stability › Watertight Integrity › General
Issued 24 April 2008 Resolved
Make engine room forward bulkhead watertight.
Action required: 705 - Other - as specified
Resolved 14 July 2008
Operations/Management › Drug and Alcohol Testing
Issued 15 January 2004 Resolved
Provide letter of enrollment with all employees listed for DAPI program, IAW 46CRF Part 16. LEGACY COMPONENT DESC: Proof of Enrollment
Due 20 January 2004
Resolved 15 January 2004
Navigation › Piloting/Steering
Issued 15 January 2004 Resolved
Provide current charts, coast pilot, light list, tide tables, IAW 46CFR184.420. LEGACY COMPONENT DESC: Marine Charts
Due 20 January 2004
Resolved 15 January 2004
Communications › Radio Communications
Issued 15 January 2004 Resolved
Provide expiration date for the hydrostatic release on the EPIRB, IAW 46CFR180.64. LEGACY COMPONENT DESC: EPIRB
Due 20 January 2004
Resolved 15 January 2004
Operations/Management › Drills/Instruction
Issued 15 January 2004 Resolved
Provide current training log, IAW 46CFR185.420. LEGACY COMPONENT DESC: Man Overboard Recovery
Due 20 January 2004
Resolved 15 January 2004
Communications › Alarms/Indicators
Issued 14 April 2003 Resolved
Provide visual indicators for bilge high level alarms. LEGACY COMPONENT DESC: Bilge Alarm
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 1 May 2003
Resolved 15 January 2004
Lifesaving › Buoyant Apparatus
Issued 14 April 2003 Resolved
Patch surface cracks on Life float using manufacturer's approved patch kit.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 May 2003
Resolved 15 January 2004
Documentation › Certificates/Documents
Issued 14 April 2003 Resolved
Renew FCC Radio Safety Cert. LEGACY COMPONENT DESC: FCC SSL
Action required: 705 - Other - as specified
Due 1 May 2003
Resolved 15 January 2004
Lifesaving › Lifejacket/PFD (Type I)
Issued 14 April 2003 Resolved
Renew retro-reflective tape on 3 adult & 2 child PFD's. LEGACY COMPONENT DESC: Retroreflective Material
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 May 2003
Resolved 15 January 2004
Navigation › Collision/Grounding Avoidance
Issued 14 April 2003 Resolved
Repair and demonstrate proper operation of horn. LEGACY COMPONENT DESC: Danger Messages
Action required: 705 - Other - as specified
Due 1 May 2003
Resolved 14 April 2003
Operations/Management › Drills/Instruction
Issued 14 April 2003 Resolved
Conduct emergency drills with new crew in the presence of a USCG Marine Inspector. LEGACY COMPONENT DESC: Man Overboard Recovery
Action required: 705 - Other - as specified
Due 1 May 2003
Resolved 14 April 2003
Accommodation/Occupational Safety › Medical/First Aid
Issued 14 April 2003 Resolved
Provide a USCG Approved first aid kit. LEGACY COMPONENT DESC: Medicine Chest
Action required: 705 - Other - as specified
Due 1 May 2003
Resolved 15 January 2004
Lifesaving
Issued 4 October 2000 Resolved
Replace the retro-reflective tape on 18 adult and 2 child PFDs._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 11 October 2000
Resolved 17 October 2000
Lifesaving
Issued 4 October 2000 Resolved
Replace the line around the life ring buoy._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 11 October 2000
Resolved 17 October 2000
Lifesaving
Issued 16 September 1999 Resolved
Provide a proper container for the distress flares._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 16 October 1999
Resolved 22 September 1999
Lifesaving
Issued 16 September 1999 Resolved
Provide proof of registration of the EPIRB._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 16 October 1999
Resolved 5 October 1999
Lifesaving
Issued 16 September 1999 Resolved
Provide an emergency broadcast placard as required._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 16 October 1999
Resolved 22 September 1999
Navigation
Issued 16 September 1999 Resolved
Repair the anchor light._x001C_ _x001C_ Vessel restricted to daylight ops until this item corrected._x001C_ _x001C_
Condition: Unknown
Due 16 October 1999
Resolved 22 September 1999
Documentation
Issued 16 September 1999 Resolved
Provide a vessel logbook with all required entries._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 16 October 1999
Resolved 22 September 1999
Documentation
Issued 24 September 1997 Resolved
Provide a current FCC Safety Certificate._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 24 October 1997
Resolved 21 October 1997
Lifesaving
Issued 24 September 1997 Resolved
Properly rig light to ring buoy._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 1 October 1997
Resolved 21 October 1997
Documentation
Issued 24 September 1997 Resolved
Provide a proper log book with all required entries._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 1 October 1997
Resolved 21 October 1997
Navigation
Issued 24 September 1997 Resolved
Tighten supports to the steering system as necessary._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 1 October 1997
Resolved 21 October 1997
Construction/Loadline
Issued 26 September 1995 Resolved
Replace bilge valve in battery room starboard side.
Condition: Unknown
Due 26 September 1995
Resolved 26 September 1995
Lifesaving
Issued 26 September 1995 Resolved
Make "minor" repairs to lifefloat covering (as discussed with inspector)._x001C_ Restencil as described in 46 CFR 180.20-5.
Condition: Unknown
Due 26 September 1995
Resolved 26 September 1995
Electrical
Issued 26 September 1995 Resolved
Replace electrical block on forward bulkhead in battery room.
Condition: Unknown
Due 26 September 1995
Resolved 26 September 1995
Lifesaving
Issued 26 September 1995 Resolved
Replace waterlight on lifefloat._x001C_ Vessel is restricted to daylight operation only, until light is replaced.
Condition: Unknown
Due 26 September 1995
Resolved 26 September 1995
Electrical
Issued 26 September 1995 Resolved
Rewire electrical connections to washdown pump port side of engine compartment. (Use of wirenuts is prohibited)
Condition: Unknown
Due 26 September 1995
Resolved 26 September 1995
Lifesaving
Issued 26 September 1995 Resolved
Replace smeared lifejacket donning placard.
Condition: Unknown
Due 26 September 1995
Resolved 26 September 1995
Documentation
Issued 19 April 1995 Resolved
Provide evidence of a valid drug testing program.
Condition: Unknown
Due 19 April 1995
Resolved 19 April 1995
Documentation
Issued 19 April 1995 Resolved
Provide evidence of a valid FCC radion safety certificate.
Condition: Unknown
Due 19 April 1995
Resolved 19 April 1995
Lifesaving
Issued 19 April 1995 Resolved
Repair or replace ring lifebuoy.
Condition: Unknown
Due 19 April 1995
Resolved 19 April 1995
Engineering
Issued 19 April 1995 Resolved
Adjust shaft packing.
Condition: Unknown
Due 19 April 1995
Resolved 19 April 1995
Lifesaving
Issued 19 April 1995 Resolved
Post a lifejacket donning placard.
Condition: Unknown
Due 19 April 1995
Resolved 19 April 1995
Lifesaving
Issued 19 April 1995 Resolved
Stencil paddlse on lifefloat with vessel name.
Condition: Unknown
Due 19 April 1995
Resolved 19 April 1995
Lifesaving
Issued 19 April 1995 Resolved
Stencil lifepreserver stowage areas with "life preservers" and the number stowed at each stowage location.
Condition: Unknown
Due 19 April 1995
Resolved 19 April 1995
Lifesaving
Issued 19 April 1995 Resolved
Capacity of vessel is reduced to 25 adults and 4 children until one additional adult life preserver is placed on board.
Condition: Unknown
Due 19 April 1995
Resolved 19 April 1995
Navigation
Issued 10 January 1989 Resolved
ADD HYDRAULIC FLUID TO PRESSURIZE STEERING SYSTEM TO 25-30 PSI IAW MANUFACTURER'S SPECIFICATIONS.
Condition: Unknown
Due 10 January 1989
Resolved 10 January 1989
Navigation
Issued 10 January 1989 Resolved
PROVIDE COAST PILOTS, NOTICES TO MARINERS, AND LIGHT LIST FOR VESSEL'S INTENDED ROUTE.
Condition: Unknown
Due 10 January 1989
Resolved 10 January 1989
Lifesaving
Issued 10 January 1989 Resolved
LABEL CABIN BULKHEAD INDICATING LIFE PRESERVER STOWAGE INSIDE.
Condition: Unknown
Due 10 January 1989
Resolved 10 January 1989
Electrical
Issued 10 January 1989 Resolved
PROVIDE ONE ADDITIONAL HAND FLASHLIGHT AS EMERGENCY LIGHTING.
Condition: Unknown
Due 10 January 1989
Resolved 10 January 1989
Construction/Loadline
Issued 10 January 1989 Resolved
MARK VESSEL'S NAME ON SIDE OF VESSEL AFT IN 4-INCH BLOCK LETTERS SINCE NAMEON TRANSOM IS OBSCURED BY DIVE PLATFORM. THIS ITEM TO BE COMPLETED AT NEXT DRYDOCK.
Condition: Unknown
Due 10 January 1989
Resolved 10 January 1989
Documentation
Issued 10 January 1989 Resolved
POST THE FOLLOWING DOCUMENTS ON A BULKHEAD ACCESSIBLE TO PASSENGERS: FCC SAFETY CERTIFICATE, FCC RADIO STATION LICENSE, USCG CERTIFICATE OF INSPECTION, USCG STABILITY LETTER.
Condition: Unknown
Due 10 January 1989
Resolved 10 January 1989
Navigation
Issued 25 September 1987 Resolved
PROVIDE NAVIGATION CHARTS AND PUBLICATIONS FOR THE VESSELS OPERATING AREA. (ST. MARYS, GA. TO CAPE SABEL. FL.) PRIOR TO PLACING THE VESSEL INTO SERVICE.
Condition: Unknown
Due 25 September 1987
Resolved 25 September 1987
Documentation
Issued 25 September 1987 Resolved
PROVIDE A VALID FCC RADIO STATION LICENSE, SECT 80.403, VALID FCC MARINE OPERATORS PERMIT, SECT 80.407, VALID COMMUNICATIONS ACT SAFETY CERTIFICATE SECT 80.401 AND A COPY OF FCC RULES, PART 80. PRIOR TO PLACING THE VESSEL INTO SERVICE.
Condition: Unknown
Due 25 September 1987
Resolved 25 September 1987

Casualty record · 3

14 March 2002Routine · role: Involved in a Marine Casualty · 1 dead · activity 1494443
18 April 2011Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 3989727
29 December 2012Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 4509099
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Recorded names · 2

SPORT DIVER (2002), LOGGERHEAD (2011–2012). Names as the Coast Guard recorded them in incident records, with the years they appear; some are renames and some are spelling variants.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.