MAURY USCG vessel records
← All vessels

SEXY WALRUS

Built
1987
Last inspected
27 February 2026
Documentation
Valid · NVDC file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 27 February 2026
…with no type recorded1
Operational controls None recorded without a removal date
Years with a record 11 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDK4447
290693
Flag
UNITED STATES
Maury page id
psix-290693

Documentation record

Registered dimensions (L × B × D)36.2 ft × 12.5 ft × 5.7 ft
Registered tonnagegross 15 / net 10
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderDELTA BOATS INC · CAPE CANAVERAL, FL, UNITED STATES · built 1987
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portBOYTON BEACH, FL
Endorsements, as the file codes themcw_un
DocumentationValid · issued 13 February 2026 · expires 28 February 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it15 - Regulatory (Subpart C or D), Gross Ton
10 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
The full record for this vessel

Behind this panel: 18 inspections, each with its date, unit and type; 49 deficiencies with the resolution recorded against each, 1 without one; operational controls, none recorded without a removal date; no tow-unit appearances recorded; 2 other recorded names; the documentation record: dimensions, tonnage, builder, hailing port and endorsements. Every line is a record the Coast Guard wrote; the counts above are the same counts as in the summary, and they are free.

Professional is $39 a month or $299 a year, or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks every detail section on every vessel page, fleet watch tied to your account, and ownership records on request. Already a subscriber? Sign in.

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 18

27 February 2026 Internal Structural Exam · Administrative Inspection · Hull Examination
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 8317735
29 September 2025 Deficiency Check · Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 8243454
4 October 2024 Annual Inspection · Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 8014556
17 April 2024 Administrative Inspection · Hull Examination · Internal Structural Exam · Examination of Repairs
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 7896791
27 July 2023 Type not recorded
No type recorded · Station Lake Worth Inlet · USCG Southeast District (CGD-SE) · Activity 7755007
21 June 2023 COI Inspection · Deficiency Check · Administrative Inspection · DAPI Audit
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 7720283
6 October 2022 Annual Inspection · Administrative Inspection · Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7572253
7 April 2022 Internal Structural Exam · Drydock Exam · Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 7426331
8 September 2021 Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 7307160
15 October 2020 Annual Inspection
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 7077623
20 May 2020 Drydock Exam · Deficiency Check · Internal Structural Exam
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 6956439
24 September 2019 Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 6819511
12 July 2018 DAPI Audit · Deficiency Check · COI Inspection
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 6475901
8 May 2018 Drydock Exam · Deficiency Check · Internal Structural Exam
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 6433865
10 October 2017 DAPI Audit · Annual Inspection
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 6284404
11 October 2016 Annual Inspection · DAPI Audit
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 6019767
10 May 2016 Internal Structural Exam · Drydock Exam · Deficiency Check
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 5873213
19 April 2016 DAPI Audit
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 5858276

Deficiency record · 49

13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 27 February 2026 No resolution recorded
Repairs or alterations to the hull, or equipment that affect the safety of the vessel must not be made without the approval of the [name withheld] is in the process of installing stern thruster without prior authorization. Approval required prior to completing installation and using equipment.
Condition: Improper Installation
Action required: 705 - Other - as specified
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 29 September 2025 Resolved
A vessel on which a pre-engineered extinguishing system is installed must have the following equipment at the operating station: An audible alarm that sounds upon discharge.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 2 October 2025
Resolution: Bezel replaced.
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Other (Conditions of employment)
Issued 4 October 2024 Resolved
Marine employers shall establish programs for the chemical testing for dangerous drugs on a random basis of crewmembers on inspected vessels. Current enrollment in random drug testing program not on board.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 October 2024
Resolution: Provided.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 4 October 2024 Resolved
A vessel must carry a minimum of one life buoy. Life buoy grab line is deteriorated and buoy is missing retro-reflective tape.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 October 2024
Resolution: Replaced.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 4 October 2024 Resolved
A visual and audible alarm must be provided at the operating station. Laz high level alarm indicator is inoperable.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 October 2024
Resolution: Repaired and tested.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 4 October 2024 Resolved
A visual indicator must be provided at the operating station to indicate when any automatic bilge pump is operating. Indicator inoperable.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 October 2024
Resolved 17 October 2024
Resolution: Repaired and tested.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 4 October 2024 Resolved
As appropriate, a vessel must carry adequate and up-to-date: U.S. Coast Pilot, Tides table, Currents Table. Coast pilot, tides and currents tables missing.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 October 2024
Resolved 17 October 2024
Resolution: Provided.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 4 October 2024 Resolved
A vessel not required to have a fire pump must have at least three 2.5 gallon buckets. Vessel had three 5 gallon buckets.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 October 2024
Resolved 17 October 2024
Resolution: Provided.
04 - Emergency Systems › N/A - No Subsystem › Muster list
Issued 4 October 2024 Resolved
The master of a vessel will have mounted at the operating station, emergency instructions containing actions to be taken in the event of a fire, heavy weather, or man overboard condictions. Emergency instructions not mounted.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 October 2024
Resolved 17 October 2024
Resolution: Posted.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 4 October 2024 Resolved
Provisions must be made for closing all supply duct cowls or scoops and exhaust discharge opennings for a space protected by a fixed gas extinguishing system. Port supply duct cover for E/R is missing.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 October 2024
Resolved 17 October 2024
Resolution: Installed.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 4 October 2024 Resolved
Each connection to a conductor must be made within an enclosure. Dead end wires found in Fuel tank compartment.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 October 2024
Resolved 17 October 2024
Resolution: Removed.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 4 October 2024 Resolved
At each inspection the owner shall be prepared to have the vessel ready for inspection of the hull structure including inspection of all watertight closures. 02 sideshell openings on port side in fuel tank compartment do not have valves or are not capped.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 October 2024
Resolved 17 October 2024
Resolution: Capped.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 4 October 2024 Resolved
The master of the vessel shall ensure that each EPIRB must be tested monthly. The EPIRB test shall be logged or otherwise documented.
Condition: Invalid
Action required: 10 - Deficiency Rectified
Resolved 4 October 2024
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 6 July 2023 Resolved
On a vessel of at least 26’ in length a visual and audible alarm must be provided at the operating station to indicate a high water level in each of the following normally unmanned spaces: a machinery space
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 13 July 2023
Resolution: Hi water alarm now operates as required.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Cargo & other hatchways
Issued 6 July 2023 Resolved
A hatch cover must: be attached to the hatch frame or coming by hinges, captive chains, or other devices of substantial strength to prevent its loss.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 13 July 2023
Resolution: metallic lanyards now attached to frame and hatch.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 6 October 2022 Resolved
Provision shall be made by means of plugs, covers, etc. to prevent the admission of air into the space protected. Seal all bulkhead penetrations that allow air into the engine room space. 46 CFR 181.20-35
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 October 2022
Resolved 11 October 2022
Resolution: Photos received.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 6 October 2022 Resolved
At least one ring life buoy must be fitted with a lifeline. Lifeline on the vessel's only ring life buoy was broken. 46 CFR 180.70(c)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 October 2022
Resolved 11 October 2022
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 14 April 2022 Resolved
Numerous voids found on the exterior hull laminate while conducting hull soundings. Make repairs to marked areas prior to credit dry-dock. 46 CFR 176.610
Action required: 705 - Other - as specified
Resolved 15 April 2022
Resolution: Repairs completed SAT.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 14 April 2022 Resolved
Hose connecting fuel fill to the fuel tank is rotted and requires replacement. Replace this section of hose prior to credit dry-dock. 46 CFR 182.720
Action required: 705 - Other - as specified
Resolved 15 April 2022
Resolution: Hose replaced.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 27 May 2020 Resolved
Blister found on hull on starboard side aft of pilot house. Blister to be ground down, dried and repaired to the satisfaction of marine inspector prior to credit dry-dock. 46 CFR 176.610
Action required: 705 - Other - as specified
Resolved 29 May 2020
Resolution: Repair completed SAT.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 27 May 2020 Resolved
Repair or replace wasted and seized submersible electrical bilge pump valves at hull penetrations in all spaces prior to credit dry-dock. 46 CFR 182.520(e)(7)
Action required: 705 - Other - as specified
Resolved 29 May 2020
Resolution: Valves replaced.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 2 October 2019 Resolved
Main engine sea water strainer and sea water flexible hoses not secured causing a higher risk of engine room flooding. Secure strainer and hoses prior to carrying passengers. 46 CFR 182.420
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 4 October 2019
Resolution: Engine sea water strainer assembly and hoses secured SAT.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 1 October 2019 Resolved
Diesel fuel leak found in engine room at an unapproved type hose clamp connection between fuel hoses. Remove leaking connection between hoses prior to operating propulsion engine. 46 CFR 182.455
Action required: 17 - Rectify deficiencies prior to departure
Resolved 1 October 2019
Resolution: Leaking connection removed. Solid hose installed between filters.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 1 October 2019 Resolved
Fuel system flexible hose lengths are longer than 30" but not SAE J-1942 with SAE J-1475 fittings. Replace with approved type hoses and fittings prior to carrying passengers. 46 CFR 182.72(e)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 4 October 2019
Resolution: Approved hoses and fitting installed SAT.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 1 October 2019 Resolved
Main engine through hull sea water supply valve handle wasted. Unable to close valve. Repair valve prior to carrying passengers. 46 CFR 179.350(c)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 4 October 2019
Resolution: Valve handle replaced. Valve operates SAT.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 1 October 2019 Resolved
Main engine exhaust flexible hose in lazerette at transom is in non-serviceable condition causing a higher risk of flooding. Replace hose prior to carrying passengers. 46 CFR 182.430
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 4 October 2019
Resolution: Flex hose replaced SAT.
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 1 October 2019 Resolved
Emergency fuel shut off valve at fuel tank does not fully close. Adjust as needed to ensure valve closes completely when pulled remotely prior to carrying passengers. 46 CFR 182.455(b)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 4 October 2019
Resolution: Valve fully closes.
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 1 October 2019 Resolved
Conduct required drills to the satisfaction of marine inspector prior to carrying passngers. 46 CFR 185.518
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 4 October 2019
Resolution: Drills completed SAT.
09 - Working and Living Conditions › 092 - Working Conditions › Obstruction/slipping, etc.
Issued 1 October 2019 Resolved
Ladder rungs to flying bridge loose making it unsafe for crew to use. Secure ladder rungs to provide solid footing while transiting up and down ladder. 46 CFR 176.830
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 October 2019
Resolved 4 October 2019
Resolution: Ladder rungs secure.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 1 October 2019 Resolved
Provide an additional 4 visual distress signals. 46 CFR 180.68(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 October 2019
Resolved 4 October 2019
Resolution: 12 distress signals onboard.
09 - Working and Living Conditions › 092 - Working Conditions › Fitness for duty - intoxication
Issued 1 October 2019 Resolved
Provide proof of submittal of MIS report. 46 CFR 16.500
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 October 2019
Resolved 4 October 2019
Resolution: MIS report provided.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 12 July 2018 Resolved
Renew raw water supply hose from thru-hull to strainer.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 August 2018
Resolved 14 September 2018
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 12 July 2018 Resolved
Repair wasted exhaust.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 August 2018
Resolved 14 September 2018
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 12 July 2018 Resolved
Demonstrate ability to secure ventilation closures in closed position.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 August 2018
Resolved 14 September 2018
03 - Water/Weathertight Conditions › N/A - No Subsystem › Windows, sidescuttles and deadlights
Issued 12 July 2018 Resolved
Renew missing stbd cabin window.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 August 2018
Resolved 14 September 2018
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 12 July 2018 Resolved
Ensure accurate labels for PFD stowage.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 August 2018
Resolved 14 September 2018
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 12 July 2018 Resolved
Shorten waterlight lanyard to 3-6ft.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 August 2018
Resolved 14 September 2018
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 12 July 2018 Resolved
Install two working portable emergency lights.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 August 2018
Resolved 12 July 2018
01 - Certificates & Documentation › 011 - Ships Certificates › Cargo Ship Safety Radio (including exemption)
Issued 12 July 2018 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 August 2018
Resolved 14 September 2018
01 - Certificates & Documentation › 011 - Ships Certificates › Cargo Ship Safety Radio (including exemption)
Issued 12 July 2018 Resolved
Renew FCC Radio Safety Certificate
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 August 2018
Resolved 14 September 2018
11 - Life Saving Appliances › N/A - No Subsystem › On board training and instructions
Issued 12 July 2018 Resolved
Update/make entry into drill log, EPIRB testing & monthly portable fire ext. inspection.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 August 2018
Resolved 14 September 2018
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 12 July 2018 Resolved
Renew expired or missing items from first aid kit.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 August 2018
Resolved 14 September 2018
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 12 July 2018 Resolved
Install hatch lanyards on both watertight hatches.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 August 2018
Resolved 14 September 2018
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 12 July 2018 Resolved
Install locking devices on battery terminal connections.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 August 2018
Resolved 14 September 2018
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 12 July 2018 Resolved
Remove dead-end wiring hanging from overhead in accomodation space.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 August 2018
Resolved 14 September 2018
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 8 May 2018 Resolved
Replace cracked muffler.
Due 8 June 2018
Resolved 11 May 2018
Resolution: Owner installed new muffler.
Stability › Unintentional Flooding › General
Issued 10 May 2016 Resolved
Prove proper operation of head discharge through hull valve.
Due 31 May 2016
Resolved 10 May 2016
Resolution: Owner installed new valve.
Engineering › Shafting/Propeller Arrangements › Stern Tube
Issued 10 May 2016 Resolved
Re-new rotted shaft log hose.
Due 31 May 2016
Resolved 12 May 2016
Resolution: Owner has installed a new shaft log hose.
Engineering › Engine Controls (Electric/Electronic) › Linkage
Issued 10 May 2016 Resolved
Install e-clip on shift cable to prevent cable from coming off shifting lever.
Due 31 May 2016
Resolved 10 May 2016
Resolution: Owner installed new E-clip.

Recorded names · 2

SPORT DIVER (2002), LOGGERHEAD (2011–2012). Names as the Coast Guard recorded them in incident records, with the years they appear; some are renames and some are spelling variants.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.