MAURY USCG vessel records Sign in
← All vessels

CAPT RIGS

CAPT RIGS is a 1987 commercial fishing vessel. The Coast Guard has recorded 71 inspections since 1987, most recently in September 2019, along with 181 deficiencies — 16 with no resolution recorded —, 1 operational control and 6 casualty investigations between 2006 and 2016.

Records from 1987 to 2019. Most recent: inspection, 17 September 2019.

Built
1987
Last inspected
17 September 2019
Documentation
Expired · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDH9216
290873
Flag
UNITED STATES
366889160, 367665810 (licence lapsed)
Maury page id
psix-290873

Inspections, by type

…with no type recorded12
…past their stated due date4
Years with a record 28 calendar years (1987–2019)
The 71 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 7 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Fishing Vessel class in Maury's sources begin in 1972.

Documentation record

Registered dimensions (L × B × D)54.0 ft × 18.5 ft × 3.2 ft
Registered tonnagegross 55 / net 37
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderMASTER MARINE CONS · FT PIERCE, FL, UNITED STATES · built 1987
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portMARATHON, FL
Trade endorsementsFishery
DocumentationExpired · issued 30 June 2004
Service, as the file records itCommercial Fishing Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it55 - Regulatory (Subpart C or D), Gross Ton
37 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDH9216MMSI 367665810 · expired · voluntarily equipped · granted 7 April 2015, cancelled 24 May 2025
WDB3595MMSI 366889160 · expired · voluntarily equipped · granted 12 April 2003, cancelled 15 June 2013
WTK2211MMSI not assigned · expired · compulsorily equipped · granted 8 August 1995, cancelled 7 January 2006 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 71

17 September 2019 In-Service Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6813847
10 September 2019 Administrative Inspection
Administrative · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6808687
26 March 2019 DAPI Audit · Annual Inspection · Deficiency Check · Construction Oversight · Administrative Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6629480
22 November 2017 Internal Structural Exam · Drydock Exam · Deficiency Check · Administrative Inspection · Annual Inspection · DAPI Audit
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6324012
20 March 2017 Administrative Inspection · Annual Inspection · Deficiency Check · DAPI Audit
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6108925
3 September 2016 Type not recorded
No type recorded · Sector Key West · USCG Southeast District (CGD-SE) · Activity 5998689
17 February 2016 COI Inspection · Administrative Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 5815518
30 November 2015 Deficiency Check · Internal Structural Exam · Drydock Exam · Administrative Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 5772257
16 June 2014 Annual Inspection · Deficiency Check
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 4892934
12 June 2014 Type not recorded
No type recorded · Sector Key West · USCG Southeast District (CGD-SE) · Activity 4887011
21 January 2010 Drydock Exam · Annual Inspection · Deficiency Check · Internal Structural Exam · Hull Examination
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 3670356
4 March 2009 Deficiency Check · Annual Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 3427909
24 March 2008 Annual Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 3170101
23 January 2008 Hull Examination
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 3134722
29 March 2007 Annual Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 2904142
25 October 2006 Type not recorded
No type recorded · Sector Key West · USCG Southeast District (CGD-SE) · Activity 2807732
16 October 2006 Type not recorded
No type recorded · Sector Key West · USCG Southeast District (CGD-SE) · Activity 2802249
15 March 2006 Deficiency Check · COI Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 2599254
26 January 2006 Hull Examination
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 2573625
24 March 2005 Deficiency Check
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 2319371
9 March 2005 Deficiency Check · Re-Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 2305713
9 December 2004 Hull Examination
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 2255791
27 May 2004 Deficiency Check
Physical examination · MSD MARATHON · USCG Southeast District (CGD-SE) · Activity 2080153
21 April 2004 Type not recorded
No type recorded · MSD MARATHON · USCG Southeast District (CGD-SE) · Activity 2049011
18 March 2004 Annual Inspection · Deficiency Check
Physical examination · MSD MARATHON · USCG Southeast District (CGD-SE) · Activity 2026612
7 April 2003 Deficiency Check
Physical examination · MSD MARATHON · USCG Southeast District (CGD-SE) · Activity 1779721
3 April 2003 Deficiency Check
Physical examination · MSD MARATHON · USCG Southeast District (CGD-SE) · Activity 1769725
3 March 2003 MARPOL Annex V Examination · Re-Inspection
Physical examination · MSD MARATHON · USCG Southeast District (CGD-SE) · Activity 1751730
27 December 2002 Hull Examination
Physical examination · MSD MARATHON · USCG Southeast District (CGD-SE) · Activity 1722347
7 September 2002 Type not recorded
No type recorded · MSD MARATHON · USCG Southeast District (CGD-SE) · Activity 1674799
3 April 2002 Deficiency Check
Physical examination · MSD MARATHON · USCG Southeast District (CGD-SE) · Activity 1629440
14 March 2002 MARPOL Annex V Examination · Re-Inspection
Physical examination · MSD MARATHON · USCG Southeast District (CGD-SE) · Activity 1493571
3 December 2001 Type not recorded
No type recorded · Station Key West · USCG Southeast District (CGD-SE) · Activity 1520965
16 November 2001 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 108204
2 April 2001 COI Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1439186
4 April 2000 Re-Inspection · MARPOL Annex V Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1450435
4 May 1999 MARPOL Annex V Examination · Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1421678
28 January 1999 Hull Examination · Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1365065
22 April 1998 COI Inspection · MARPOL Annex V Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 792232
23 February 1998 Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 790187
31 July 1997 Re-Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1447772
25 July 1996 Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1363730
16 May 1996 Re-Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1394563
4 May 1996 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 176547
22 April 1996 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1082836
25 October 1995 Examination of Repairs
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1190927
13 October 1995 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 459
14 August 1995 Administrative
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 875764
4 August 1995 Examination of Repairs
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 881774
1 June 1995 COI Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1189280
23 March 1995 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 80034
5 August 1994 Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 862575
20 July 1994 Re-Inspection · Deficiency Check · Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 867885
5 May 1994 Drydock Extension
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1326440
16 June 1993 Re-Inspection · Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 848693
1 June 1992 COI Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1256032
6 May 1992 Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 944868
14 August 1991 Re-Inspection · Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1309700
30 November 1990 Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1221974
8 August 1990 Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1211288
18 July 1990 Re-Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 911667
6 June 1990 Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 899547
16 March 1990 Damage Survey
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 930956
12 March 1990 Administrative
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 910352
19 December 1989 Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1221393
22 November 1989 Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1234416
25 October 1989 Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1210506
7 June 1989 COI Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 888770
7 March 1989 Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 892534
11 January 1989 Hull Examination · Re-Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 898097
10 August 1987 Initial Certification
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1009799

Deficiency record · 181

04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 8 October 2019 No resolution recorded
Adequate emergency lighting automatically actuated upon failure of the main lighting system shall be fitted along the line of escape. Vessel emergency lighting currently does not automatically actuate upon power failure to facilitate a safe evacuation in the event of an emergency. Provide automatically actuating lighting to facilitate escape in an emergency.
Action required: 705 - Other - as specified
Resolution: PRIOR TO OVERNIGHT PASSENGERS
09 - Working and Living Conditions › 091 - Living Conditions › Furnishings
Issued 8 October 2019 No resolution recorded
Mattresses are to be treated to give it fire resistant properties. There is no indication that the current mattresses are in any way flame resistant. Provide verification of fire resistance of mattresses.
Action required: 705 - Other - as specified
Resolution: PRIOR TO OVERNIGHT PASSENGERS
04 - Emergency Systems › N/A - No Subsystem › Location of emergency installations
Issued 8 October 2019 No resolution recorded
Vessel must have 2 avenues of escape from all areas accessible to the passengers. Vessel does not have adequate means of escape escape from the berthing area passageway. Provide means of escape that are in compliance with regulations.
Action required: 705 - Other - as specified
Resolution: PRIOR TO OVERNIGHT PASSENGERS
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 8 October 2019 No resolution recorded
Means of escape must be adequately marked both inside and out. Escape hatches are not adequately marked. Ensure that hatches are marked with two inch lettering "Emergency Escape Keep Clear"
Action required: 705 - Other - as specified
Resolution: PRIOR TO OVERNIGHT PASSENGERS
04 - Emergency Systems › N/A - No Subsystem › Muster list
Issued 8 October 2019 No resolution recorded
Each vessel shall have a suitable number of watchmen to ensure that patrols are conducted during night time, whether or not the vessel is underway, to guard against, and give alarm in case of; a fire, man overboard, or other dangerous situation. For these watchmen, provide a list of areas/ procedures to use while on watch. Additionally, provide an entry in the log for watch relief.
Action required: 705 - Other - as specified
Resolution: PRIOR TO OVERNIGHT PASSENGERS
04 - Emergency Systems › N/A - No Subsystem › Abandon ship drills
Issued 8 October 2019 No resolution recorded
On a vessel of more than 24 hours duration, passengers shall don life jackets and and go to the appropriate embarkation station. Ensure that emergency escape drills are conducted each time overnight passengers are embarked to ensure their understanding of emergency escape routes. These drills should be logged in the ship's log.
Action required: 705 - Other - as specified
Resolution: PRIOR TO OVERNIGHT PASSENGERS
09 - Working and Living Conditions › 091 - Living Conditions › Furnishings
Issued 8 October 2019 No resolution recorded
All electric cooking equipment doors shall be provided with heavy duty hinges and locking devices to prevent accidental opening in heavy seas. Oven does not have a locking device. Provide locking device for oven.
Action required: 705 - Other - as specified
Resolution: PRIOR TO OVERNIGHT PASSENGERS
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 8 October 2019 No resolution recorded
All aisles and doorways shall be not less than 24 inches in width. Vessel doorways to each passenger accommodation space is under 24 inches and do not comply with this standard. Provide a written plan to the OCMI on how the vessel will achieve compliance with these required standards within 30 days (08NOV2019).
Action required: 50 - Rectify deficiencies w/in 30 days
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 8 October 2019 No resolution recorded
Ladders or steps shall be provided for each top bunk. There are no steps or ladders for the top bunks. Provide a written plan to the OCMI on how the vessel will achieve compliance with these required standards within 30 days NOV 08, 2019.
Action required: 50 - Rectify deficiencies w/in 30 days
04 - Emergency Systems › N/A - No Subsystem › Means of communication between safety centre and other control stations
Issued 8 October 2019 No resolution recorded
Vessel must have a public address system that is audible in all accommodation spaces. Public address system can not be heard in forward berthing. Provide a Public address system that is audible in the all accommodation spaces.
Action required: 705 - Other - as specified
Resolution: PRIOR TO OVERNIGHT PASSENGERS
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 8 October 2019 No resolution recorded
Machinery spaces must be separated from accommodation spaces by boundaries that prevent the passage of vapors. The engine room and machinery space hatches do not have an adequate vapor barrier. Install an adequate vapor barrier to prevent he passage of vapors.
Action required: 705 - Other - as specified
Resolution: PRIOR TO OVERNIGHT PASSENGERS
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 8 October 2019 No resolution recorded
Sources of ignition shall be kept clear of and suitably insulated from any woodwork or other combustible matter. The bulkhead, cabinet and paper towel holder around the stove are not adequately insulated from the stove in the galley space. Ensure means to adequately prevent/insulate any woodwork or combustible materials around the stove.
Action required: 705 - Other - as specified
Resolution: PRIOR TO OVERNIGHT PASSENGERS
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 19 July 2019 No resolution recorded
Vessel must install a reach rod to allow for closing of the bilge pipe valve forward of the collision bulkhead above the weatherdeck or provide for a closing mechanism aft of the bulkhead.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 30 November 2019 — due date passed with no resolution recorded
Resolution: Deficiency must be rectified at next drydock (November 2019)
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 19 July 2019 No resolution recorded
Ensure mechanical ventilation is tied into the fireboy circuit. Blower must shut down upon activation of fireboy in conjunction with main diesel engines and generator. Blower has been temporarily removed. Once re-install occurs, operation test of shutdown must be successfully performed and witnessedby a USCG Marine Inspector.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 August 2019 — due date passed with no resolution recorded
09 - Working and Living Conditions › 092 - Working Conditions › Guards - fencing around dangerous machinery parts
Issued 19 July 2019 No resolution recorded
Main diesel engines have no guards around pulleys/belts. Provide guards w/in 30 days.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 August 2019 — due date passed with no resolution recorded
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 26 March 2019 Resolved
All portable fire extinguishers and pre-engineered fire extinguishing systems must be serviced annually.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 July 2019
07 - Fire Safety › N/A - No Subsystem › Operation of Fire protection systems
Issued 26 March 2019 No resolution recorded
Lazaret Fireboy must be operational and have controls operable from the pilot house.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 August 2019 — due date passed with no resolution recorded
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 26 March 2019 Resolved
Fire hose must be of of commercial grade(constructed of an inner rubber tube, plies of braided cotton reinforcement and outer cover of equivalent material) and shall be fitted with a commercial garden hose nozzle of good grade bronze or equivalent material.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 July 2019
07 - Fire Safety › N/A - No Subsystem › Operation of Fire protection systems
Issued 26 March 2019 Resolved
When fireboy is activated all engines, generator and power ventilation must shut down automatically.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 19 July 2019
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 26 March 2019 Resolved
All bilge high level alarms must be operational and produce and audible and visual alarm at the operating station.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 July 2019
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 26 March 2019 Resolved
Fixed bilge piping manifolds must be accessible and labeled.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 July 2019
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 26 March 2019 Resolved
Remote fuel system shut off valves shall be operable from outside the tank compartment. Access cap is seized
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 July 2019
Resolution: access cap fixed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 26 March 2019 Resolved
Straps and supports used to hold exhaust up are not made of noncombustible material.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 July 2019
Resolution: aluminum straps were constructed
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 26 March 2019 Resolved
All spaces containing diesel machinery must have adequate ventilation. There is no ventilation in the aft generator space. Submit plans to OCMI for approval prior to making alterations.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 July 2019
Resolution: aft generator space (lazarette) has vents on both port and starboard sides
09 - Working and Living Conditions › 091 - Living Conditions › Ventilation (Accommodation)
Issued 26 March 2019 Resolved
Engine space must be segregated by vapor-tight hatches from accommodation spaces.
Action required: 705 - Other - as specified
Resolved 17 July 2019
Resolution: The gasket replaced and the carpet was trimmed back to create a vapor tight seal for the hatches. leading to the engine room and compressor/machinery space.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 26 March 2019 Resolved
All machinery must be maintained as to afford adequate protection against fire, explosion. machinery failure and personnel injury. Aft space containing generator, exhaust, steering gear, fire system, etc is corroding and not being maintained adequately.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 July 2019
Resolution: Vessel crew removed corroded hydraulic fittings from engine space and replaced hoses. Additionally, crew cleaned up engine rust in and around other machinery and is in the process of painting.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 26 March 2019 Resolved
Repair generator space battery tray, Battery posts shall have no more than 4 connections and no sharp bends.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 July 2019
Resolution: Battery tray was repaired and batteries now have only 4 connections with the largest at the base of the terminal.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 26 March 2019 Resolved
Vessel must have at least two operable portable battery lights. one must be located at the operating station and the other at the access to the propulsion machinery space.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 July 2019
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 26 March 2019 Resolved
All electrical must be supported at 18 inch intervals.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 17 July 2019
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 26 March 2019 Resolved
Lights in aft generator space must be installed.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 July 2019
04 - Emergency Systems › N/A - No Subsystem › Public address system
Issued 26 March 2019 Resolved
Provide a public address system
Action required: 17 - Rectify deficiencies prior to departure
Resolved 19 July 2019
02 - Structural Conditions › N/A - No Subsystem › Hull - cracking
Issued 26 March 2019 Resolved
Repair window/porthole on port side of forward cabin space.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 July 2019
Resolution: Porthole window was replaced in kind.
09 - Working and Living Conditions › 092 - Working Conditions › Safe means of access
Issued 26 March 2019 Resolved
Install storm rails on port and STBD side for shutting down engine room ventilation for safety of crew member.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 July 2019
Resolution: grab rails were installed to secure to while securing ventialtion on both port and starboard sides.
10 - Safety of Navigation › N/A - No Subsystem › Radar
Issued 26 March 2019 Resolved
Provide demonstration of properly tuned radar system.
Action required: 705 - Other - as specified
Resolved 17 July 2019
Resolution: Radar took approximately 10 minutes to warm up, but provided accurate contact identification after that time.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 26 March 2019 Resolved
Replace cracked paddles in life float.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 July 2019
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 26 March 2019 Resolved
Replace 4 adult life jackets, 3 child life jackets and ensure all have life jacket lights.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 July 2019
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 26 March 2019 Resolved
Stow life jackets in an accessible location and mark locations.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 July 2019
Resolution: vessel purchased waterproof box to stow life jackets on 02 deck
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 26 March 2019 Resolved
Remove and replace expired 06 red distress flares. All Orange flares expire in 02 months.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 July 2019
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 26 March 2019 Resolved
Provide first aid kit that is approved under 160.041
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 July 2019
05 - Radio Communications › N/A - No Subsystem › VHF EPIRB
Issued 26 March 2019 Resolved
EPIRB missing registration sticker.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 17 July 2019
11 - Life Saving Appliances › N/A - No Subsystem › Operation of Life Saving Appliances
Issued 26 March 2019 Resolved
EPIRB hydrostatic release is expired. replace.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 July 2019
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 26 March 2019 Resolved
Post all pages of stability letter at operating station.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 July 2019
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 26 March 2019 Resolved
Post all pages of COI where passengers will see it.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 17 July 2019
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 26 March 2019 Resolved
All drills and EPIRB testing must be logged.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 July 2019
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 26 March 2019 Resolved
Vessel must have up to date publications on board. Light list, Coast Pilot, tide tables
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 17 July 2019
04 - Emergency Systems › N/A - No Subsystem › Means of communication between safety centre and other control stations
Issued 26 March 2019 Resolved
Satellite phone must be operational. Vessel restricted to 20 NM from shore.
Action required: 705 - Other - as specified
Resolved 17 July 2019
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 26 March 2019 Resolved
Vessel must conduct underway Man over board, fire drill and operational tests in the presence of a Coast Guard Marine Inspector.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 July 2019
Resolution: Vessel conducted efficient MOB drill with OSCAR
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 26 March 2019 Resolved
Make fuel tanks available for inspection.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 July 2019
Resolution: Approved fuel tank construction completed and installation verified at deficiency check.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 26 March 2019 Resolved
Provide means to inspect forward lower bilge.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 July 2019
Resolution: A ladder was installed to perform inspections of the forepeak.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Scuppers, inlets and discharges
Issued 26 March 2019 Resolved
Demonstrate overboard positive shut off valve in forward compartment.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 July 2019
Resolution: there is not an overboard valve as there is a centralized bilge system. This requires a reach rod on the weather deck to close the valve forward of the collision bulkhead.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 26 March 2019 Resolved
Vertical and horizontal surfaces within 3 ft of cooking areas must be complaint with ASTM E-84 (fire retardant). Curtains, draperies or free hanging fabrics must not be fitted within 3 ft of appliance.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 July 2019
Resolution: curtains removed
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 26 March 2019 Resolved
All dead ended wires must be removed or capped.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 July 2019
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 26 March 2019 Resolved
No more than 4 wires per each battery post. Largest wires at the base.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 July 2019
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 26 March 2019 Resolved
Each hatch that provides access to crew or passenger accommodation spaces must be operable from both sides. Emergency escape hatch is not operable from outside of the space.
Action required: 705 - Other - as specified
Resolved 17 July 2019
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 26 March 2019 Resolved
Provide documentation/approval of generator install in lazaret space.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 17 July 2019
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 26 March 2019 Resolved
Exhaust on port side board on forward end supporting is broken.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 July 2019
Operations/Management › Drug and Alcohol Testing › Testing, Pre-employment
Issued 30 March 2018 Resolved
Provide pre-employment and enroll documentation for two new crew members. Crew members must be fully compliant prior to working in safety sensitive position.
Action required: 705 - Other - as specified
Due 6 April 2018
Resolved 3 April 2018
Resolution: Documentation provided.
Fire Fighting › Means of Escape › Escape Route Signs
Issued 30 March 2018 Resolved
Provide labels for emergency escape
Action required: 705 - Other - as specified
Due 6 April 2018
Resolved 3 April 2018
Resolution: Emergency escape labeled.
Documentation › Markings/Placards › Capacity Marking
Issued 30 March 2018 Resolved
Properly label upper deck with passenger limit.
Action required: 705 - Other - as specified
Due 6 April 2018
Resolved 3 April 2018
Resolution: Passenger count labeled on above ladder.
Engineering › Diesel Engine (propulsion-direct drive) › Exhaust Manifold
Issued 30 March 2018 Resolved
Install lagging on both propulsion engines turbos and exhauts.
Action required: 705 - Other - as specified
Due 6 April 2018
Resolved 3 April 2018
Resolution: Lagging replaced.
Lifesaving › Lifejacket/PFD (Type I) › Storage
Issued 30 March 2018 Resolved
Properly label PFD stowage location.
Action required: 705 - Other - as specified
Due 6 April 2018
Resolved 3 April 2018
Resolution: Stowage location marked.
Fire Fighting › Fixed Fire Detection System › Smoke Detectors
Issued 30 March 2018 Resolved
Provide smoke detector (UL 217) for starboard berthing.
Action required: 705 - Other - as specified
Due 6 April 2018
Resolved 3 April 2018
Resolution: Detector installed in STBD berthing.
Lifesaving › Lifejacket/PFD (Type I) › Quantity
Issued 30 March 2018 Resolved
Provide Two(02) Adult PFDs to be in compliance with COI. Reduced to 37 total persons.
Action required: 705 - Other - as specified
Due 6 April 2018
Resolved 3 April 2018
Resolution: 02 new PFDs replaced.
Fire Fighting › Fixed Fire Detection System › Arrangement
Issued 30 March 2018 Resolved
Provide fire suppression for aft generator compartment. Vessel restricted from using aft generator. Submit plans to OCMI prior to installation of system.
Action required: 705 - Other - as specified
Due 30 April 2018
Resolved 5 January 2019
Resolution: Fireboy installed, vessel unable to operate generator to test shutdown.
Construction/Loadline › Hull › Bottom Plating
Issued 22 November 2017 Resolved
Repair hull in way of all Coast Guard marked areas.
Action required: 705 - Other - as specified
Due 17 February 2018
Resolved 10 April 2018
Stability › Watertight Integrity › General
Issued 22 November 2017 Resolved
Repair/replace hatch lanyard for steering compartment hatch.
Action required: 705 - Other - as specified
Due 17 February 2018
Resolved 3 January 2018
Resolution: Lanyard replaced on hatch.
Electrical › Electric Supply System (service) › Battery Installation
Issued 22 November 2017 Resolved
Repair/renew starboard battery box in engine room.
Action required: 705 - Other - as specified
Due 17 February 2018
Resolved 3 January 2018
Resolution: Battery box repaired.
Electrical › Electric Supply System (service) › Overcurrent Device
Issued 22 November 2017 Resolved
Reinstall over current device in junction box above port batteries in engine room.
Action required: 705 - Other - as specified
Due 17 February 2018
Resolved 3 January 2018
Resolution: Over current device reinstalled.
Electrical › Electrical Distribution System (service) › Cable
Issued 22 November 2017 Resolved
Install cable splice for hot water heater in an enclosure or renew cable.
Action required: 705 - Other - as specified
Due 17 February 2018
Resolved 3 January 2018
Resolution: Enclosure installed.
Electrical › Electrical Distribution System (service) › Distribution Panel Bus
Issued 22 November 2017 Resolved
Secure terminal strip and cover for the junction box above hot water heater.
Action required: 705 - Other - as specified
Due 17 February 2018
Resolved 3 January 2018
Resolution: Terminal strip and cover secured.
Electrical › Electrical Distribution System (service) › Distribution Panel Bus
Issued 22 November 2017 Resolved
Install proper front on electrical panel in compression room.
Action required: 705 - Other - as specified
Due 17 February 2018
Resolved 3 January 2018
Resolution: cover installed
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 22 November 2017 Resolved
Repair port and starboard steps going to bow.
Action required: 705 - Other - as specified
Due 17 February 2018
Resolved 3 January 2018
Resolution: Aluminum supports added for support.
Engineering › Bilge Water Management System › Valve
Issued 22 November 2017 Resolved
Install a screw-down valve in the bilge pipe that penetrates the collision bulkhead.
Action required: 705 - Other - as specified
Due 17 February 2018
Resolved 3 January 2018
Resolution: Screw-down valve installed.
Engineering › Freshwater System (jacketwater cooling) › Valve
Issued 22 November 2017 Resolved
Make sea valve for forward generator available for inspection.
Action required: 705 - Other - as specified
Due 17 February 2018
Resolved 3 January 2018
Resolution: New valve installed.
Engineering › Diesel Engine (auxiliary) › Block
Issued 22 November 2017 Resolved
Provide engine data on aft generator
Action required: 705 - Other - as specified
Due 27 November 2017
Resolved 3 April 2018
Resolution: Engine data supplied: John Deere Series 300, Model 4039
Lifesaving › Lifefloat › Markings
Issued 22 November 2017 Resolved
Label life float with total capacity.
Action required: 705 - Other - as specified
Due 6 April 2018
Resolved 3 April 2018
Resolution: Life float labeled.
Electrical › Lighting (service) › Lighting Fixture
Issued 22 November 2017 Resolved
Renew forward flood light.
Action required: 705 - Other - as specified
Due 6 April 2018
Resolved 3 April 2018
Resolution: Flood light replaced.
Fire Fighting › Portable CO2 Fire Extinguisher › Number
Issued 20 March 2017 Resolved
Provide required number of approved portable fire extinguishers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 29 March 2017
Resolution: All tanks onboard.
Fire Fighting › Fixed Gas Fire Extinguishing System › Tanks
Issued 20 March 2017 Resolved
Renew or hydrostatically test fire boy cylinder. Demonstrate proper operation.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 29 March 2017
Resolution: New tank installed.
Fire Fighting › Fire Pumps › Pressure
Issued 20 March 2017 Resolved
Prove proper operation of fire pump.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 29 March 2017
Resolution: Pump operational.
Engineering › Fuel Oil Service System › Tank
Issued 20 March 2017 Resolved
Electrically bond port fuel tank to common ground.
Action required: 705 - Other - as specified
Due 20 April 2017
Resolved 29 March 2017
Resolution: Port tank bonding wire connected to common ground.
Lifesaving › Lifejacket/PFD (Type I) › Storage
Issued 20 March 2017 Resolved
Label the following: Fuel cut offs, PFD stowage, upper deck passenger capacity, life float.
Action required: 705 - Other - as specified
Due 20 April 2017
Resolved 29 March 2017
Resolution: Labels completed as required.
Lifesaving › Lifebuoys › Serviceable
Issued 16 June 2014 Resolved
Replace wasted lifebuoy.
Action required: 705 - Other - as specified
Due 20 June 2014
Resolved 18 June 2014
Lifesaving › Lifejacket/PFD (Type I) › Lights
Issued 16 June 2014 Resolved
Replace life jacket lights.
Action required: 705 - Other - as specified
Due 20 June 2014
Resolved 18 June 2014
Operations/Management › Equipment Service/Testing › EPIRB
Issued 16 June 2014 Resolved
Log all EPIRB monthly tests.
Action required: 705 - Other - as specified
Due 20 June 2014
Resolved 18 June 2014
Lifesaving › Lifefloat › Serviceable
Issued 16 June 2014 Resolved
Replace or repair lifefloat to serviceable condition.
Action required: 705 - Other - as specified
Due 26 June 2014
Resolved 18 June 2014
Communications › Alarms/Indicators › High Water Alarm
Issued 16 June 2014 Resolved
Make bilge high water alarm audible.
Action required: 705 - Other - as specified
Due 20 June 2014
Resolved 18 June 2014
Documentation › Certificates/Documents › Certificate of Inspection
Issued 12 June 2014 Resolved
Vessel failed to undergo an annual inspection by the due date. Vessel must undergo a successful annual inspection with a Coast Guard Marine Inspector.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 June 2014
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 29 March 2010 Resolved
Vessel must provide proof of enrollment for crew in a drug testing program.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 May 2010
Navigation › Piloting/Steering › Tide/Tidal Current Tables
Issued 29 March 2010 Resolved
Vessel must acquire current rules of the road, light list, tides and currents and coast pilot.
Action required: 701 - Prior to carriage of passengers/cargo
Due 29 March 2010
Resolved 7 May 2010
Documentation › Markings/Placards › Warning Signs
Issued 29 March 2010 Resolved
Emergency broadcast placard must be filled out w/ vessel details.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 April 2010
Navigation › Piloting/Steering › Magnetic Compass
Issued 29 March 2010 Resolved
Compass must illuminate if vessel is to operate at night.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 April 2010
Communications › Radio Communications › EPIRB
Issued 29 March 2010 Resolved
EPIRB must be positioned in a float free area of the vessel.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 April 2010
Documentation › Markings/Placards › Capacity Marking
Issued 29 March 2010 Resolved
Vessel must provide placard for max passengers allowed on upper deck.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 April 2010
Deck/Cargo › Mooring/Anchoring › Anchor Chain (general)
Issued 29 March 2010 Resolved
Install new anchor chain.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 April 2010
Lifesaving › Lifejacket/PFD (General) › Condition
Issued 29 March 2010 Resolved
Acquire 12 adult and 04 child PFD's
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 April 2010
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 29 March 2010 Resolved
Lifeline and light line must be at least 5/16" in diameter.
Action required: 701 - Prior to carriage of passengers/cargo
Due 29 March 2010
Resolved 8 April 2010
Construction/Loadline › Penetrations › Valve Flange
Issued 21 January 2010 Resolved
Make all through hull fittings within 6" above the water line available for inspection.
Due 28 January 2010
Resolved 25 January 2010
Construction/Loadline › Hull › Side Shell
Issued 21 January 2010 Resolved
Make noted side shell damage available for closer inspection.
Due 28 January 2010
Resolved 25 January 2010
Construction/Loadline › Hull › Hull Plating
Issued 21 January 2010 Resolved
Install new zincs
Due 28 January 2010
Resolved 25 January 2010
Engineering › Sea-water System (primary cooling) › Valve
Issued 21 January 2010 Resolved
Install new valve wheels in lazarette & engine room on portside.
Due 28 January 2010
Resolved 25 January 2010
Construction/Loadline › Structures › Transverse Bulkhead
Issued 21 January 2010 Resolved
Install watertight bulkhead & watertight penetrations aft engine room bulkhead.
Due 21 February 2010
Resolved 29 March 2010
Construction/Loadline › Structures › End Bulkhead
Issued 21 January 2010 Resolved
Install section of ceiling above engine room
Due 21 February 2010
Resolved 29 March 2010
Electrical › Electrical Distribution System (service) › Wiring
Issued 21 January 2010 Resolved
Remove all broken wiring.
Due 21 February 2010
Resolved 29 March 2010
Accommodation/Occupational Safety › Occupational Safety › Spark Producing Device
Issued 21 January 2010 Resolved
Clean bilges and conduct engine wipe down in lazarette and engine room
Due 28 January 2010
Resolved 25 January 2010
Documentation › Certificates/Documents › Certificate of Inspection
Issued 21 January 2010 Resolved
Post COI and stability letter in a conspicuous place.
Due 28 January 2010
Resolved 25 January 2010
Documentation › Logs/Records › Logbook (official)
Issued 21 January 2010 Resolved
Vessel must have official logbook onboard.
Action required: 701 - Prior to carriage of passengers/cargo
Due 29 March 2010
Resolved 29 March 2010
Lifesaving › Lifejacket/PFD (General) › Retroreflective Material
Issued 4 March 2009 Resolved
Replace the retroreflective tape on 9 adult lifejackets as discussed.
Due 4 March 2009
Resolved 6 March 2009
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 4 March 2009 Resolved
Replace grab line on lifebuoy on main deck.
Due 4 March 2009
Resolved 6 March 2009
Communications › Alarms/Indicators › Bilge Alarm
Issued 4 March 2009 Resolved
Make proper repairs to the lazarette bilge high level audible alarm and prove proper operation to the satisfaction of an attending marine inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Due 4 March 2009
Resolved 6 March 2009
Electrical › Lighting (emergency) › Lighting Fixture
Issued 15 March 2006 Resolved
Prove proper operation of emergency lighting prior to carrying passengers for hire.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 March 2006
Electrical › Lighting (emergency) › Lighting Fixture
Issued 9 March 2005 Resolved
Prove proper operation of emergency lighting prior to carrying passengers for hire.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 March 2005
Communications › Audible Communications › Bell
Issued 9 March 2005 Resolved
Provide ships bell in accordance with 33 CFR Part 86, with nominal mouth diameter of no less than 7.8".
Action required: 705 - Other - as specified
Due 9 April 2005
Resolved 24 March 2005
Accommodation/Occupational Safety › Occupational Safety › Portable Electric Equipment/Appliances
Issued 9 March 2005 Resolved
Install closing device on oven door.
Action required: 705 - Other - as specified
Due 9 April 2005
Resolved 24 March 2005
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 9 March 2005 Resolved
Prove proper operation of engine shutdown in way of fixed fire extinguishing system.
Action required: 705 - Other - as specified
Due 9 April 2005
Resolved 24 March 2005
Lifesaving › Buoyant Apparatus
Issued 18 March 2004 Resolved
Replace Lifefloat with a CG approved model not later than 25Mar2004 LEGACY COMPONENT DESC: Life Float
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 25 March 2004
Resolved 25 March 2004
Resolution: Observed new L/F.
Documentation › Logs/Records
Issued 18 March 2004 Resolved
Create and maintain a Training and Lifesaving Equipment Maintenance Logbook as required by 46CFR185.420 and 46CFR185.722 and 728. LEGACY COMPONENT DESC: Training and Lifesaving Equipment Maintenance
Condition: Unknown
Action required: 705 - Other - as specified
Due 18 April 2004
Resolved 27 May 2004
Resolution: Observed logbook with entries for the previous two months.
Operations/Management › Navigation Safety
Issued 18 March 2004 Resolved
Provide current copies of the required navigation publications or excerpts for the areas of operation. (i.e. Light List, Tide Tables, Tidal Current Tables, and International Rules of the Road) LEGACY COMPONENT DESC: Carriage of Charts and Publications
Condition: Unknown
Action required: 705 - Other - as specified
Due 18 April 2004
Resolved 27 May 2004
Resolution: Corrected.
Accommodation/Occupational Safety › Occupational Safety
Issued 18 March 2004 Resolved
Install netting, mesh, or additional course rails between the top most rail and deck so that no space is greater than 4 inches where passengers have access to the railing, in accordance with MSO Miami MSIB# 02-001. LEGACY COMPONENT DESC: Deck Rail
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 29 April 2004
Resolved 27 May 2004
Resolution: As stated in the narrative, passengers are no longer allowed on the upper deck.
Documentation › Certificates/Documents
Issued 3 March 2003 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 705 - Other - as specified
Due 10 March 2003
Resolved 7 April 2003
Resolution: Received fax from vessel representative of FCC Station License application.
Lifesaving › Buoyant Apparatus
Issued 3 March 2003 Resolved
Renew pendants on Life float using U/V ray resistant, floating line, dark in color. LEGACY COMPONENT DESC: Pendants
Action required: 705 - Other - as specified
Due 10 March 2003
Resolved 3 April 2003
Resolution: Corrected.
Engineering › Fuel Oil Service System
Issued 3 March 2003 Resolved
Re-stencil emergency fuel shut-offs. LEGACY COMPONENT DESC: Tank
Action required: 705 - Other - as specified
Due 10 March 2003
Resolved 3 April 2003
Resolution: Corrected.
Communications › Radio Communications
Issued 3 March 2003 Resolved
Post Emergency Radio Broadcast Placard. LEGACY COMPONENT DESC: VFH Radiotelephone
Action required: 705 - Other - as specified
Due 10 March 2003
Resolved 7 April 2003
Resolution: Recieved fax from vessel representative of reciept fro purchase of Emergency Broadcast Placard.
Fire Fighting › Miscellaneous Items
Issued 3 March 2003 Resolved
Renew smoke detector in the main cabin.
Action required: 705 - Other - as specified
Due 10 March 2003
Resolved 3 April 2003
Resolution: Corrected.
Lifesaving › Lifebuoys
Issued 14 March 2002 Resolved
Renew netting on 22-person lifefloat
Condition: Improper/Lack of Maintenance
Due 14 April 2002
Resolved 3 April 2002
Resolution: Corrected.
Lifesaving › Lifebuoys
Issued 14 March 2002 Resolved
Renew retro-reflective tape on lifefloat
Condition: Improper/Lack of Maintenance
Due 14 April 2002
Resolved 3 April 2002
Resolution: Corrected.
Lifesaving › Lifebuoys
Issued 14 March 2002 Resolved
Provide (2) 4 ft paddles for lifefloat.
Condition: Unknown
Due 14 April 2002
Resolved 3 April 2002
Resolution: Corrected.
Lifesaving › Lifebuoys
Issued 14 March 2002 Resolved
Patch surface cracks on lifefloat using manufacturer's approved patch kit.
Condition: Improper/Lack of Maintenance
Due 14 April 2002
Resolved 3 April 2002
Resolution: Corrected.
Lifesaving › Lifejacket/PFD (Type I)
Issued 14 March 2002 Resolved
Install additional retro-reflective tape on (11) adult and (1) child PFDs. LEGACY COMPONENT DESC: Retroreflective Material
Condition: Improper/Lack of Maintenance
Due 14 April 2002
Resolved 3 April 2002
Resolution: Corrected.
Electrical › Electrical Distribution System (service)
Issued 14 March 2002 Resolved
Remove dead-end wires in engine room in way of generator fuel pump. LEGACY COMPONENT DESC: Wiring
Condition: Improper Installation
Due 14 April 2002
Resolved 3 April 2002
Resolution: Corrected.
Engineering › Diesel Engine (propulsion-reduction gear)
Issued 14 March 2002 Resolved
Provide double hose clamps for MDE exhaust prior to carrying passengers. Corrected 14Mar02 LEGACY COMPONENT DESC: Piping (exhaust)
Condition: Unknown
Due 14 April 2002
Resolved 14 March 2002
Resolution: Corrected.
Electrical › Electric Supply System (service)
Issued 14 March 2002 Resolved
Clean battery terminals for MDE and generator. LEGACY COMPONENT DESC: Battery Conductor
Condition: Improper/Lack of Maintenance
Due 14 April 2002
Resolved 3 April 2002
Resolution: Corrected.
Fire Fighting › Fixed Gas Fire Extinguishing System
Issued 14 March 2002 Resolved
Service fixed fire-fighting system.
Condition: Improper/Lack of Maintenance
Due 14 April 2002
Resolved 3 April 2002
Resolution: Corrected.
Electrical › Electrical Distribution System (service)
Issued 14 March 2002 Resolved
Permanently install wires for live-well pump. LEGACY COMPONENT DESC: Wiring
Condition: Improper Installation
Due 14 April 2002
Resolved 3 April 2002
Resolution: Corrected.
Electrical › Electrical Distribution System (service)
Issued 14 March 2002 Resolved
Remove dead-end wires from Lazeret in way of old bilge pump installation and old bonding to rudderpost or re-attach bonding wire. LEGACY COMPONENT DESC: Wiring
Condition: Improper Installation
Due 14 April 2002
Resolved 3 April 2002
Resolution: Corrected.
Accommodation/Occupational Safety › Sleeping Accommodations
Issued 14 March 2002 Resolved
Install smoke detectors in all passenger accommodations spaces.
Condition: Unknown
Due 14 April 2002
Resolved 3 April 2002
Resolution: Corrected.
Operations/Management › Navigation Safety
Issued 14 March 2002 Resolved
Provide voyage plan.
Condition: Improper/Lack of Maintenance
Due 14 April 2002
Resolved 3 April 2002
Resolution: Corrected.
Lifesaving
Issued 2 April 2001 Resolved
EPIRB Hydrostatic Release expired. Item replaced same date.
Condition: Unknown
Due 2 April 2001
Resolved 2 April 2001
Construction/Loadline
Issued 2 April 2001 Resolved
Repair audible alarm for high water alarms. Item corrected prior to operation.
Condition: Unknown
Due 2 April 2001
Resolved 18 April 2001
Lifesaving
Issued 2 April 2001 Resolved
Retro-reflective material deteriorated on 10 PFDs. Repalced same date.
Condition: Unknown
Due 2 April 2001
Resolved 18 April 2001
Navigation
Issued 22 April 1998 Resolved
Demonstrate proper operation of SSB radio.
Condition: Unknown
Due 22 April 1998
Resolved 22 April 1998
Lifesaving
Issued 22 April 1998 Resolved
Renew retro-reflective tape on 2 adult PFD's.
Condition: Unknown
Due 22 April 1998
Resolved 22 April 1998
Documentation
Issued 22 April 1998 Resolved
Post Stability Letter upon receipt.
Condition: Unknown
Due 22 April 1998
Resolved 22 April 1998
Lifesaving
Issued 22 April 1998 Resolved
Provide Category 1, 406MHz EPIRB prior to operating beyond 3 miles from shore.
Condition: Unknown
Due 22 April 1998
Resolved 22 April 1998
Accommodation/Occupational Safety
Issued 22 April 1998 Resolved
Provide locking device on overboard valve for sewage holding tank.
Condition: Unknown
Due 22 April 1998
Resolved 22 April 1998
Construction/Loadline
Issued 25 October 1995 Resolved
MAKE REPAIR TO THE DECK TO HULL JOINT IN FOREPEAK FROM THE COLLISION BULKHEAD STARBOARD TO 3 FEET AFT OF THE BOW - PORT. REGLASS AND REBOLT THIS ENTIRE AREA AS DISCUSSED WITH ATTENDING INSPECTOR. REPAIR TO BE COMPLETED PRIOR TO CARRYING PASSENGERS.
Condition: Unknown
Due 20 February 1996
Resolved 20 February 1996
Lifesaving
Issued 1 June 1995 Resolved
Repair and repaint both lifefloats International orange.
Condition: Unknown
Due 1 June 1995
Resolved 1 June 1995
Navigation
Issued 1 June 1995 Resolved
Reposition anchor light so as to be visible 360 degrees.
Condition: Unknown
Due 1 June 1995
Resolved 1 June 1995
Lifesaving
Issued 1 June 1995 Resolved
Repair lights on nine pfds.
Condition: Unknown
Due 1 June 1995
Resolved 1 June 1995
Documentation
Issued 1 June 1995 Resolved
Provide and post FCC station license. Vessels route limited to not more than 1000 feet from shore until completed.
Condition: Unknown
Due 1 June 1995
Resolved 1 June 1995
Construction/Loadline
Issued 1 June 1995 Resolved
Close holes in forward engine room bulkhead.
Condition: Unknown
Due 1 June 1995
Resolved 1 June 1995
Lifesaving
Issued 20 July 1994 Resolved
Install retro tape on 6 adult pfd's.
Condition: Unknown
Due 26 July 1994
Resolved 26 July 1994
Electrical
Issued 20 July 1994 Resolved
Install covers over light fixtures in galley and engineroom.
Condition: Unknown
Due 26 July 1994
Resolved 26 July 1994
Navigation
Issued 20 July 1994 Resolved
Tighten packing on both rudder logs.
Condition: Unknown
Due 20 July 1994
Resolved 20 July 1994
Lifesaving
Issued 20 July 1994 Resolved
Renew or repair ringbuoy.
Condition: Unknown
Due 20 July 1994
Resolved 20 July 1994
Fire Fighting
Issued 20 July 1994 Resolved
Install metallic hose nozzle on fire hose.
Condition: Unknown
Due 20 July 1994
Resolved 20 July 1994
Lifesaving
Issued 20 July 1994 Resolved
Repair light on 1 child pfd.
Condition: Unknown
Due 26 July 1994
Resolved 26 July 1994
Navigation
Issued 16 June 1993 Resolved
Tighten or re-pack port rudder packing.
Condition: Unknown
Due 2 August 1993
Resolved 2 August 1993
Construction/Loadline
Issued 16 June 1993 Resolved
Repair engine driven fire/bilge pump.
Condition: Unknown
Due 2 August 1993
Resolved 2 August 1993
Documentation
Issued 16 June 1993 Resolved
Provide FCC certificate limited ot not more than 1000 feet from shore untilcompleted.
Condition: Unknown
Due 2 August 1993
Resolved 2 August 1993
Engineering
Issued 16 June 1993 Resolved
Repair cable for starboard fuel shutoff and stencil.
Condition: Unknown
Due 2 August 1993
Resolved 2 August 1993
Lifesaving
Issued 16 June 1993 Resolved
Repair waterlight for lifefloat.
Condition: Unknown
Due 2 August 1993
Resolved 2 August 1993
Lifesaving
Issued 16 June 1993 Resolved
Clean Hydraulic oil from pfd's.
Condition: Unknown
Due 2 August 1993
Resolved 2 August 1993
Lifesaving
Issued 14 August 1991 Resolved
REPLACE EPIRB WITH CLASS 'A' BUILT ON OR AFTER 01OCT88 OF A CATEGORY 1 (406HZ) PRIOR TO OPERATING BEYOND 20 MILES FROM A HARBOR OF SAFE REFUGE.
Condition: Unknown
Due 25 September 1991
Resolved 25 September 1991
Engineering
Issued 18 July 1990 Resolved
MODIFY EMER F/O SHUTOFF VALVES SO THEY AR OPERABLE FROM OUTSIDE THE FUEL TANK SPACE.
Condition: Unknown
Due 18 July 1990
Resolved 18 July 1990
Lifesaving
Issued 18 July 1990 Resolved
RENEW EBIRB BATTERY. VESSEL IS LIMITED TO COASTWISE ROUTE UNTIL THIS IS COMPLETED.
Condition: Unknown
Due 18 July 1990
Resolved 18 July 1990
Electrical
Issued 6 June 1990 Resolved
REPLACE MISSING BREAKERS IN AIR CONDITIONING PANNEL W/ SPARE BREAKERS
Condition: Unknown
Due 6 June 1990
Resolved 6 June 1990
Construction/Loadline
Issued 6 June 1990 Resolved
PERFORM STABILITY TEST (CG WITNESS) BY 25JUL90
Condition: Unknown
Due 6 June 1990
Resolved 6 June 1990
Electrical
Issued 6 June 1990 Resolved
REPLACE ALL GLOBES ON LIGHTS.
Condition: Unknown
Due 6 June 1990
Resolved 6 June 1990
Engineering
Issued 6 June 1990 Resolved
PROVIDE 30X30 CORROSION RESISTANT FLAME SCREENS ON FUEL OIL VENTS.
Condition: Unknown
Due 6 June 1990
Resolved 6 June 1990
Navigation
Issued 25 October 1989 Resolved
MOVE ANCHOR LIGHT. CURRENTLY OBSTRUCTED. TO BE COMPLETED PRIOR TO A SCHEDULED ANCHORING TRIP.
Condition: Unknown
Due 25 October 1989
Resolved 25 October 1989
Accommodation/Occupational Safety
Issued 7 June 1989 Resolved
PROVIDE AUTOMATIC BATTERY POWERED (6 HR.) EMERGENCY LIGHTS FOR FWD LOWER CABIN.
Condition: Unknown
Due 7 June 1989
Resolved 7 June 1989
Lifesaving
Issued 7 June 1989 Resolved
THE SMALL LIFEFLOAT IS NOT LOCATED FOAT FREE UNDER RADAR.
Condition: Unknown
Due 7 June 1989
Resolved 7 June 1989
Electrical
Issued 11 January 1989 Resolved
REPLACE ALL SOLID CORE ELECT. WIRE AND REPLACE WITH UL STRANDED WIRE.
Condition: Unknown
Due 11 January 1989
Resolved 11 January 1989
Engineering
Issued 11 January 1989 Resolved
REPLACE FUEL SUPPLY AND RETURN HOSE FOR AC GENERATOR WITH WIRE REINFORCED WITH INNER TUBE AND OUTER COVER THAT IS CG APPROVED AND MEETS PSTM D1692 WITH COMPRESSION FITTINGS OR CG TYPE A HOSE (PROVIDED LESS THAN 30") WITH COMPRESSION FITTINGS OR DOUBLE HOSE CLAMPS PROVIDED THE COPPER TUBING IS
Condition: Unknown
Due 11 January 1989
Resolved 11 January 1989
Lifesaving
Issued 11 January 1989 Resolved
RE-MARK ALL PFD STOWAGE TO SHOW ACTUAL STOWAGE LOCATIONS.
Condition: Unknown
Due 11 January 1989
Resolved 11 January 1989
Documentation
Issued 11 January 1989 Resolved
NEXT DRYDOCK DUE 11JUL90.
Condition: Unknown
Due 11 January 1989
Resolved 11 January 1989
Navigation
Issued 11 January 1989 Resolved
PROVIDE 8" SHIP'S BELL.
Condition: Unknown
Due 11 January 1989
Resolved 11 January 1989
Engineering
Issued 11 January 1989 Resolved
SECURE STBD PACKING GLAND (SHAFT).
Condition: Unknown
Due 11 January 1989
Resolved 11 January 1989
Construction/Loadline
Issued 11 January 1989 Resolved
REPLACE STEP AFT OF GENERATOR.
Condition: Unknown
Due 11 January 1989
Resolved 11 January 1989
Electrical
Issued 11 January 1989 Resolved
INSTALL AMMETER FOR AC GENERATOR.
Condition: Unknown
Due 11 January 1989
Resolved 11 January 1989

Casualty record · 6

16 October 2006Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 dead · activity 2802249
12 December 2006Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 dead · activity 2839017
12 June 2009Routine · role: Involved in a Marine Casualty · 1 injured · activity 3502161
14 April 2010Routine · role: Reported in distress · activity 3717862
7 September 2013Routine · role: Involved in a Marine Casualty · 1 injured · activity 4712168
3 September 2016Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 dead · activity 5998689
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Recorded names · 1

PLAYMATE (2006–2016). Names as the Coast Guard recorded them in incident records, with the years they appear; some are renames and some are spelling variants.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.