Records from 2006 to 2019. Most recent: inspection, 17 September 2019.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 8 October 2019
No resolution recorded
Adequate emergency lighting automatically actuated upon failure of the main lighting system shall be fitted along the line of escape. Vessel emergency lighting currently does not automatically actuate upon power failure to facilitate a safe evacuation in the event of an emergency. Provide automatically actuating lighting to facilitate escape in an emergency.
Action required: 705 - Other - as specified
Resolution: PRIOR TO OVERNIGHT PASSENGERS
09 - Working and Living Conditions › 091 - Living Conditions › Furnishings
Issued 8 October 2019
No resolution recorded
Mattresses are to be treated to give it fire resistant properties. There is no indication that the current mattresses are in any way flame resistant. Provide verification of fire resistance of mattresses.
Action required: 705 - Other - as specified
Resolution: PRIOR TO OVERNIGHT PASSENGERS
04 - Emergency Systems › N/A - No Subsystem › Location of emergency installations
Issued 8 October 2019
No resolution recorded
Vessel must have 2 avenues of escape from all areas accessible to the passengers. Vessel does not have adequate means of escape escape from the berthing area passageway. Provide means of escape that are in compliance with regulations.
Action required: 705 - Other - as specified
Resolution: PRIOR TO OVERNIGHT PASSENGERS
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 8 October 2019
No resolution recorded
Means of escape must be adequately marked both inside and out. Escape hatches are not adequately marked. Ensure that hatches are marked with two inch lettering "Emergency Escape Keep Clear"
Action required: 705 - Other - as specified
Resolution: PRIOR TO OVERNIGHT PASSENGERS
04 - Emergency Systems › N/A - No Subsystem › Muster list
Issued 8 October 2019
No resolution recorded
Each vessel shall have a suitable number of watchmen to ensure that patrols are conducted during night time, whether or not the vessel is underway, to guard against, and give alarm in case of; a fire, man overboard, or other dangerous situation. For these watchmen, provide a list of areas/ procedures to use while on watch. Additionally, provide an entry in the log for watch relief.
Action required: 705 - Other - as specified
Resolution: PRIOR TO OVERNIGHT PASSENGERS
04 - Emergency Systems › N/A - No Subsystem › Abandon ship drills
Issued 8 October 2019
No resolution recorded
On a vessel of more than 24 hours duration, passengers shall don life jackets and and go to the appropriate embarkation station. Ensure that emergency escape drills are conducted each time overnight passengers are embarked to ensure their understanding of emergency escape routes. These drills should be logged in the ship's log.
Action required: 705 - Other - as specified
Resolution: PRIOR TO OVERNIGHT PASSENGERS
09 - Working and Living Conditions › 091 - Living Conditions › Furnishings
Issued 8 October 2019
No resolution recorded
All electric cooking equipment doors shall be provided with heavy duty hinges and locking devices to prevent accidental opening in heavy seas. Oven does not have a locking device. Provide locking device for oven.
Action required: 705 - Other - as specified
Resolution: PRIOR TO OVERNIGHT PASSENGERS
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 8 October 2019
No resolution recorded
All aisles and doorways shall be not less than 24 inches in width. Vessel doorways to each passenger accommodation space is under 24 inches and do not comply with this standard. Provide a written plan to the OCMI on how the vessel will achieve compliance with these required standards within 30 days (08NOV2019).
Action required: 50 - Rectify deficiencies w/in 30 days
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 8 October 2019
No resolution recorded
Ladders or steps shall be provided for each top bunk. There are no steps or ladders for the top bunks. Provide a written plan to the OCMI on how the vessel will achieve compliance with these required standards within 30 days NOV 08, 2019.
Action required: 50 - Rectify deficiencies w/in 30 days
04 - Emergency Systems › N/A - No Subsystem › Means of communication between safety centre and other control stations
Issued 8 October 2019
No resolution recorded
Vessel must have a public address system that is audible in all accommodation spaces. Public address system can not be heard in forward berthing. Provide a Public address system that is audible in the all accommodation spaces.
Action required: 705 - Other - as specified
Resolution: PRIOR TO OVERNIGHT PASSENGERS
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 8 October 2019
No resolution recorded
Machinery spaces must be separated from accommodation spaces by boundaries that prevent the passage of vapors. The engine room and machinery space hatches do not have an adequate vapor barrier. Install an adequate vapor barrier to prevent he passage of vapors.
Action required: 705 - Other - as specified
Resolution: PRIOR TO OVERNIGHT PASSENGERS
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 8 October 2019
No resolution recorded
Sources of ignition shall be kept clear of and suitably insulated from any woodwork or other combustible matter. The bulkhead, cabinet and paper towel holder around the stove are not adequately insulated from the stove in the galley space. Ensure means to adequately prevent/insulate any woodwork or combustible materials around the stove.
Action required: 705 - Other - as specified
Resolution: PRIOR TO OVERNIGHT PASSENGERS
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 19 July 2019
No resolution recorded
Vessel must install a reach rod to allow for closing of the bilge pipe valve forward of the collision bulkhead above the weatherdeck or provide for a closing mechanism aft of the bulkhead.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 30 November 2019 — due date passed with no resolution recorded
Resolution: Deficiency must be rectified at next drydock (November 2019)
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 19 July 2019
No resolution recorded
Ensure mechanical ventilation is tied into the fireboy circuit. Blower must shut down upon activation of fireboy in conjunction with main diesel engines and generator. Blower has been temporarily removed. Once re-install occurs, operation test of shutdown must be successfully performed and witnessedby a USCG Marine Inspector.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 August 2019 — due date passed with no resolution recorded
09 - Working and Living Conditions › 092 - Working Conditions › Guards - fencing around dangerous machinery parts
Issued 19 July 2019
No resolution recorded
Main diesel engines have no guards around pulleys/belts. Provide guards w/in 30 days.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 August 2019 — due date passed with no resolution recorded
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 26 March 2019
Resolved
All portable fire extinguishers and pre-engineered fire extinguishing systems must be serviced annually.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 July 2019
07 - Fire Safety › N/A - No Subsystem › Operation of Fire protection systems
Issued 26 March 2019
No resolution recorded
Lazaret Fireboy must be operational and have controls operable from the pilot house.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 August 2019 — due date passed with no resolution recorded
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 26 March 2019
Resolved
Fire hose must be of of commercial grade(constructed of an inner rubber tube, plies of braided cotton reinforcement and outer cover of equivalent material) and shall be fitted with a commercial garden hose nozzle of good grade bronze or equivalent material.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 July 2019
07 - Fire Safety › N/A - No Subsystem › Operation of Fire protection systems
Issued 26 March 2019
Resolved
When fireboy is activated all engines, generator and power ventilation must shut down automatically.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 19 July 2019
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 26 March 2019
Resolved
All bilge high level alarms must be operational and produce and audible and visual alarm at the operating station.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 July 2019
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 26 March 2019
Resolved
Fixed bilge piping manifolds must be accessible and labeled.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 July 2019
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 26 March 2019
Resolved
Remote fuel system shut off valves shall be operable from outside the tank compartment. Access cap is seized
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 July 2019
Resolution: access cap fixed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 26 March 2019
Resolved
Straps and supports used to hold exhaust up are not made of noncombustible material.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 July 2019
Resolution: aluminum straps were constructed
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 26 March 2019
Resolved
All spaces containing diesel machinery must have adequate ventilation. There is no ventilation in the aft generator space. Submit plans to OCMI for approval prior to making alterations.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 July 2019
Resolution: aft generator space (lazarette) has vents on both port and starboard sides
09 - Working and Living Conditions › 091 - Living Conditions › Ventilation (Accommodation)
Issued 26 March 2019
Resolved
Engine space must be segregated by vapor-tight hatches from accommodation spaces.
Action required: 705 - Other - as specified
Resolved 17 July 2019
Resolution: The gasket replaced and the carpet was trimmed back to create a vapor tight seal for the hatches. leading to the engine room and compressor/machinery space.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 26 March 2019
Resolved
All machinery must be maintained as to afford adequate protection against fire, explosion. machinery failure and personnel injury. Aft space containing generator, exhaust, steering gear, fire system, etc is corroding and not being maintained adequately.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 July 2019
Resolution: Vessel crew removed corroded hydraulic fittings from engine space and replaced hoses. Additionally, crew cleaned up engine rust in and around other machinery and is in the process of painting.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 26 March 2019
Resolved
Repair generator space battery tray, Battery posts shall have no more than 4 connections and no sharp bends.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 July 2019
Resolution: Battery tray was repaired and batteries now have only 4 connections with the largest at the base of the terminal.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 26 March 2019
Resolved
Vessel must have at least two operable portable battery lights. one must be located at the operating station and the other at the access to the propulsion machinery space.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 July 2019
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 26 March 2019
Resolved
All electrical must be supported at 18 inch intervals.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 17 July 2019
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 26 March 2019
Resolved
Lights in aft generator space must be installed.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 July 2019
04 - Emergency Systems › N/A - No Subsystem › Public address system
Issued 26 March 2019
Resolved
Provide a public address system
Action required: 17 - Rectify deficiencies prior to departure
Resolved 19 July 2019
02 - Structural Conditions › N/A - No Subsystem › Hull - cracking
Issued 26 March 2019
Resolved
Repair window/porthole on port side of forward cabin space.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 July 2019
Resolution: Porthole window was replaced in kind.
09 - Working and Living Conditions › 092 - Working Conditions › Safe means of access
Issued 26 March 2019
Resolved
Install storm rails on port and STBD side for shutting down engine room ventilation for safety of crew member.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 July 2019
Resolution: grab rails were installed to secure to while securing ventialtion on both port and starboard sides.
10 - Safety of Navigation › N/A - No Subsystem › Radar
Issued 26 March 2019
Resolved
Provide demonstration of properly tuned radar system.
Action required: 705 - Other - as specified
Resolved 17 July 2019
Resolution: Radar took approximately 10 minutes to warm up, but provided accurate contact identification after that time.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 26 March 2019
Resolved
Replace cracked paddles in life float.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 July 2019
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 26 March 2019
Resolved
Replace 4 adult life jackets, 3 child life jackets and ensure all have life jacket lights.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 July 2019
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 26 March 2019
Resolved
Stow life jackets in an accessible location and mark locations.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 July 2019
Resolution: vessel purchased waterproof box to stow life jackets on 02 deck
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 26 March 2019
Resolved
Remove and replace expired 06 red distress flares. All Orange flares expire in 02 months.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 July 2019
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 26 March 2019
Resolved
Provide first aid kit that is approved under 160.041
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 July 2019
05 - Radio Communications › N/A - No Subsystem › VHF EPIRB
Issued 26 March 2019
Resolved
EPIRB missing registration sticker.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 17 July 2019
11 - Life Saving Appliances › N/A - No Subsystem › Operation of Life Saving Appliances
Issued 26 March 2019
Resolved
EPIRB hydrostatic release is expired. replace.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 July 2019
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 26 March 2019
Resolved
Post all pages of stability letter at operating station.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 July 2019
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 26 March 2019
Resolved
Post all pages of COI where passengers will see it.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 17 July 2019
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 26 March 2019
Resolved
All drills and EPIRB testing must be logged.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 July 2019
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 26 March 2019
Resolved
Vessel must have up to date publications on board. Light list, Coast Pilot, tide tables
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 17 July 2019
04 - Emergency Systems › N/A - No Subsystem › Means of communication between safety centre and other control stations
Issued 26 March 2019
Resolved
Satellite phone must be operational. Vessel restricted to 20 NM from shore.
Action required: 705 - Other - as specified
Resolved 17 July 2019
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 26 March 2019
Resolved
Vessel must conduct underway Man over board, fire drill and operational tests in the presence of a Coast Guard Marine Inspector.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 July 2019
Resolution: Vessel conducted efficient MOB drill with OSCAR
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 26 March 2019
Resolved
Make fuel tanks available for inspection.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 July 2019
Resolution: Approved fuel tank construction completed and installation verified at deficiency check.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 26 March 2019
Resolved
Provide means to inspect forward lower bilge.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 July 2019
Resolution: A ladder was installed to perform inspections of the forepeak.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Scuppers, inlets and discharges
Issued 26 March 2019
Resolved
Demonstrate overboard positive shut off valve in forward compartment.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 July 2019
Resolution: there is not an overboard valve as there is a centralized bilge system. This requires a reach rod on the weather deck to close the valve forward of the collision bulkhead.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 26 March 2019
Resolved
Vertical and horizontal surfaces within 3 ft of cooking areas must be complaint with ASTM E-84 (fire retardant). Curtains, draperies or free hanging fabrics must not be fitted within 3 ft of appliance.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 July 2019
Resolution: curtains removed
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 26 March 2019
Resolved
All dead ended wires must be removed or capped.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 July 2019
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 26 March 2019
Resolved
No more than 4 wires per each battery post. Largest wires at the base.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 July 2019
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 26 March 2019
Resolved
Each hatch that provides access to crew or passenger accommodation spaces must be operable from both sides. Emergency escape hatch is not operable from outside of the space.
Action required: 705 - Other - as specified
Resolved 17 July 2019
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 26 March 2019
Resolved
Provide documentation/approval of generator install in lazaret space.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 17 July 2019
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 26 March 2019
Resolved
Exhaust on port side board on forward end supporting is broken.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 July 2019
Operations/Management › Drug and Alcohol Testing › Testing, Pre-employment
Issued 30 March 2018
Resolved
Provide pre-employment and enroll documentation for two new crew members. Crew members must be fully compliant prior to working in safety sensitive position.
Action required: 705 - Other - as specified
Due 6 April 2018
Resolved 3 April 2018
Resolution: Documentation provided.
Fire Fighting › Means of Escape › Escape Route Signs
Issued 30 March 2018
Resolved
Provide labels for emergency escape
Action required: 705 - Other - as specified
Due 6 April 2018
Resolved 3 April 2018
Resolution: Emergency escape labeled.
Documentation › Markings/Placards › Capacity Marking
Issued 30 March 2018
Resolved
Properly label upper deck with passenger limit.
Action required: 705 - Other - as specified
Due 6 April 2018
Resolved 3 April 2018
Resolution: Passenger count labeled on above ladder.
Engineering › Diesel Engine (propulsion-direct drive) › Exhaust Manifold
Issued 30 March 2018
Resolved
Install lagging on both propulsion engines turbos and exhauts.
Action required: 705 - Other - as specified
Due 6 April 2018
Resolved 3 April 2018
Resolution: Lagging replaced.
Lifesaving › Lifejacket/PFD (Type I) › Storage
Issued 30 March 2018
Resolved
Properly label PFD stowage location.
Action required: 705 - Other - as specified
Due 6 April 2018
Resolved 3 April 2018
Resolution: Stowage location marked.
Fire Fighting › Fixed Fire Detection System › Smoke Detectors
Issued 30 March 2018
Resolved
Provide smoke detector (UL 217) for starboard berthing.
Action required: 705 - Other - as specified
Due 6 April 2018
Resolved 3 April 2018
Resolution: Detector installed in STBD berthing.
Lifesaving › Lifejacket/PFD (Type I) › Quantity
Issued 30 March 2018
Resolved
Provide Two(02) Adult PFDs to be in compliance with COI. Reduced to 37 total persons.
Action required: 705 - Other - as specified
Due 6 April 2018
Resolved 3 April 2018
Resolution: 02 new PFDs replaced.
Fire Fighting › Fixed Fire Detection System › Arrangement
Issued 30 March 2018
Resolved
Provide fire suppression for aft generator compartment. Vessel restricted from using aft generator. Submit plans to OCMI prior to installation of system.
Action required: 705 - Other - as specified
Due 30 April 2018
Resolved 5 January 2019
Resolution: Fireboy installed, vessel unable to operate generator to test shutdown.
Construction/Loadline › Hull › Bottom Plating
Issued 22 November 2017
Resolved
Repair hull in way of all Coast Guard marked areas.
Action required: 705 - Other - as specified
Due 17 February 2018
Resolved 10 April 2018
Stability › Watertight Integrity › General
Issued 22 November 2017
Resolved
Repair/replace hatch lanyard for steering compartment hatch.
Action required: 705 - Other - as specified
Due 17 February 2018
Resolved 3 January 2018
Resolution: Lanyard replaced on hatch.
Electrical › Electric Supply System (service) › Battery Installation
Issued 22 November 2017
Resolved
Repair/renew starboard battery box in engine room.
Action required: 705 - Other - as specified
Due 17 February 2018
Resolved 3 January 2018
Resolution: Battery box repaired.
Electrical › Electric Supply System (service) › Overcurrent Device
Issued 22 November 2017
Resolved
Reinstall over current device in junction box above port batteries in engine room.
Action required: 705 - Other - as specified
Due 17 February 2018
Resolved 3 January 2018
Resolution: Over current device reinstalled.
Electrical › Electrical Distribution System (service) › Cable
Issued 22 November 2017
Resolved
Install cable splice for hot water heater in an enclosure or renew cable.
Action required: 705 - Other - as specified
Due 17 February 2018
Resolved 3 January 2018
Resolution: Enclosure installed.
Electrical › Electrical Distribution System (service) › Distribution Panel Bus
Issued 22 November 2017
Resolved
Secure terminal strip and cover for the junction box above hot water heater.
Action required: 705 - Other - as specified
Due 17 February 2018
Resolved 3 January 2018
Resolution: Terminal strip and cover secured.
Electrical › Electrical Distribution System (service) › Distribution Panel Bus
Issued 22 November 2017
Resolved
Install proper front on electrical panel in compression room.
Action required: 705 - Other - as specified
Due 17 February 2018
Resolved 3 January 2018
Resolution: cover installed
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 22 November 2017
Resolved
Repair port and starboard steps going to bow.
Action required: 705 - Other - as specified
Due 17 February 2018
Resolved 3 January 2018
Resolution: Aluminum supports added for support.
Engineering › Bilge Water Management System › Valve
Issued 22 November 2017
Resolved
Install a screw-down valve in the bilge pipe that penetrates the collision bulkhead.
Action required: 705 - Other - as specified
Due 17 February 2018
Resolved 3 January 2018
Resolution: Screw-down valve installed.
Engineering › Freshwater System (jacketwater cooling) › Valve
Issued 22 November 2017
Resolved
Make sea valve for forward generator available for inspection.
Action required: 705 - Other - as specified
Due 17 February 2018
Resolved 3 January 2018
Resolution: New valve installed.
Engineering › Diesel Engine (auxiliary) › Block
Issued 22 November 2017
Resolved
Provide engine data on aft generator
Action required: 705 - Other - as specified
Due 27 November 2017
Resolved 3 April 2018
Resolution: Engine data supplied: John Deere Series 300, Model 4039
Lifesaving › Lifefloat › Markings
Issued 22 November 2017
Resolved
Label life float with total capacity.
Action required: 705 - Other - as specified
Due 6 April 2018
Resolved 3 April 2018
Resolution: Life float labeled.
Electrical › Lighting (service) › Lighting Fixture
Issued 22 November 2017
Resolved
Renew forward flood light.
Action required: 705 - Other - as specified
Due 6 April 2018
Resolved 3 April 2018
Resolution: Flood light replaced.
Fire Fighting › Portable CO2 Fire Extinguisher › Number
Issued 20 March 2017
Resolved
Provide required number of approved portable fire extinguishers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 29 March 2017
Resolution: All tanks onboard.
Fire Fighting › Fixed Gas Fire Extinguishing System › Tanks
Issued 20 March 2017
Resolved
Renew or hydrostatically test fire boy cylinder. Demonstrate proper operation.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 29 March 2017
Resolution: New tank installed.
Fire Fighting › Fire Pumps › Pressure
Issued 20 March 2017
Resolved
Prove proper operation of fire pump.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 29 March 2017
Resolution: Pump operational.
Engineering › Fuel Oil Service System › Tank
Issued 20 March 2017
Resolved
Electrically bond port fuel tank to common ground.
Action required: 705 - Other - as specified
Due 20 April 2017
Resolved 29 March 2017
Resolution: Port tank bonding wire connected to common ground.
Lifesaving › Lifejacket/PFD (Type I) › Storage
Issued 20 March 2017
Resolved
Label the following: Fuel cut offs, PFD stowage, upper deck passenger capacity, life float.
Action required: 705 - Other - as specified
Due 20 April 2017
Resolved 29 March 2017
Resolution: Labels completed as required.