Documentation record
Registered dimensions (L × B × D)52.0 ft × 17.5 ft × 8.0 ft
Registered tonnagegross 48 / net 39
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderMILLER BOATS · PANAMA CITY, FL, UNITED STATES · built 1987
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portPANAMA CITY BEACH, FL
Endorsements, as the file codes themcw_un, fi
DocumentationValid · issued 22 January 2026 · expires 28 February 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it48 - Simplified, Gross Ton
39 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
The full record for this vessel
Behind this panel: 26 inspections, each with its date, unit and type; 16 deficiencies with the resolution recorded against each; operational controls, none recorded without a removal date; no tow-unit appearances recorded; no other recorded names; the documentation record: dimensions, tonnage, builder, hailing port and endorsements. Every line is a record the Coast
Guard wrote; the counts above are the same counts as in the summary, and they are free.
Professional is $39 a month or $299 a year,
or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks
every detail section on every vessel page, fleet watch tied to your account, and ownership records
on request. Already a subscriber? Sign in.
Maury does not score, rate or grade vessels, at any price.
Inspection history · 26
12 November 2025
Administrative Inspection · Drydock Exam · Vessel Attendance · Examination of Repairs · Internal Structural Exam
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 8267431
25 September 2025
Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 8238802
3 September 2025
Administrative Inspection · Special Consideration
Administrative · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 8226499
15 April 2025
Administrative Inspection · Special Consideration
Administrative · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 8112267
4 March 2025
Administrative Inspection · Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 8086323
24 September 2024
Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 8008419
22 September 2023
COI Inspection · Deficiency Check · Administrative Inspection · Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7796423
21 September 2023
Administrative Inspection
Administrative · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7796066
13 October 2022
Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7578696
5 August 2022
Type not recorded
No type recorded · USCGC HAROLD MILLER (WPC-1138) · USCG Southeast District (CGD-SE) · Activity 7537209
28 July 2022
In-Service Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7522864
27 May 2022
Administrative Inspection
Administrative · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7460532
15 December 2021
Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7369157
1 December 2021
Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7360316
3 October 2021
Examination of Repairs · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7334905
20 July 2021
In-Service Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7261789
2 December 2020
Administrative Inspection · DAPI Audit · Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7104797
23 September 2020
Damage Survey
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7084413
10 October 2019
Administrative Inspection · Annual Inspection · DAPI Audit · In-Service Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6839068
27 February 2019
Drydock Exam · Internal Structural Exam · Examination of Repairs · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6651872
14 November 2018
Administrative Inspection
Administrative · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6580468
19 September 2018
Administrative Inspection · COI Inspection · DAPI Audit
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6543820
26 June 2018
Type not recorded
No type recorded · USCGC MARLIN (WPB 87304) · USCG Northeast District (CGD-NE) · Activity 6502483
11 October 2017
Administrative Inspection · DAPI Audit · Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6284874
3 February 2017
Administrative Inspection · Hull Examination · Internal Structural Exam · Deficiency Check
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6082261
7 November 2016
Annual Inspection · Administrative Inspection · DAPI Audit · Deficiency Check
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6035581
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 29 September 2023
Resolved
Starboard fuel oil remote shutoff valve would not fully close.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 4 October 2023
Resolution: Witnessed operation of starboard fuel oil shutoff valve.
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 29 September 2023
Resolved
During COI exam, emergency drill could not be conducted since vessel was at DD.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 4 October 2023
Resolution: Witnessed fire and MOB drills.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 21 September 2023
Resolved
COI expired on 19 Sep 2023. Vessel is prohibited from operating as a small passenger vessel.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 29 September 2023
Resolution: Attended vessel and conducted satisfactory COI/DD/ISE. Full term COI provided to vessel owner.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 2 December 2020
Resolved
Reduce Engine Room storage to ensure the safety and security of the space.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 January 2021
Resolved 14 December 2020
Resolution: Gear removed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 2 December 2020
Resolved
Replace Engine Room Bilge Alarm Float Switch to ensure satisfactory arrangement for draining the compartment.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 January 2021
Resolved 14 December 2020
Resolution: New float switch installed installed.
09 - Working and Living Conditions › 091 - Living Conditions › Lighting (Accommodation)
Issued 2 December 2020
Resolved
Repair starboard Engine Room light fixtures to provide services necessary for safety under emergency conditions.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 January 2021
Resolved 14 December 2020
Resolution: New lights installed.
09 - Working and Living Conditions › 091 - Living Conditions › Electrical devices
Issued 2 December 2020
Resolved
Reduce number of power strips to protect passengers, crew, and other persons, and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment or electrical shock.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 December 2020
Resolved 14 December 2020
Resolution: Power strips removed.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 2 December 2020
Resolved
Provide proof that a suitable hand tiller is capable as the auxiliary means of steering.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 January 2021
Resolved 14 December 2020
Resolution: Tiller removed and modified.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 2 December 2020
Resolved
Master must provide proof of Emergency Procedures.
Condition: Design Flaw
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 December 2020
Resolved 14 December 2020
Resolution: Emergency procedures provided.
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 2 December 2020
Resolved
Renew liferaft hydrostatic release to verify that it has been servied at an approved facility.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 December 2020
Resolved 14 December 2020
Resolution: New Hydro installed.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 2 December 2020
Resolved
Provide original scantlings.
Condition: Design Flaw
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 December 2020
Resolved 3 March 2021
Resolution: Scantlings received and bulkhead inserts were approved.
Engineering › Shafting/Propeller Arrangements › Bearing
Issued 3 February 2017
Resolved
Replace cutlass bearing
Action required: 705 - Other - as specified
Due 3 March 2017
Resolved 13 February 2017
Resolution: Vessel replaced cutlass bearing
Operations/Management › Drug and Alcohol Testing › Employee Coverage
Issued 7 November 2016
Resolved
Captain could not show proof of enrollement into drug program at the time of inspection.
Condition: Invalid
Action required: 705 - Other - as specified
Due 7 November 2016
Resolved 7 November 2016
Resolution: Captain provided proof of enrollement.
Operations/Management › Drug and Alcohol Testing › Testing, Equipment
Issued 7 November 2016
Resolved
Alcohol test equipment was not onboard.
Action required: 705 - Other - as specified
Due 7 November 2016
Resolved 7 November 2016
Resolution: Alcohol test equipment was ordered.
Fire Fighting › Fire Bucket › Lanyard
Issued 7 November 2016
Resolved
Fire buckets were not onboard and stenciled.
Condition: Invalid
Action required: 705 - Other - as specified
Due 7 November 2016
Resolved 7 November 2016
Resolution: Fire buckets were provided.
Lifesaving › Lifejacket/PFD (General) › Condition
Issued 7 November 2016
Resolved
Retro on life jackets did not meet requirements.
Condition: Invalid
Action required: 705 - Other - as specified
Due 7 November 2016
Resolved 7 November 2016
Resolution: Retro was replaced.