SCUBA DOS is a 1987 passenger vessel (inspected). The Coast Guard has recorded 60 inspections since 1988, most recently in October 2025, along with 80 deficiencies and 1 operational control.

Records from 1988 to 2025. Most recent: inspection, 16 October 2025.

Built
1987
Last inspected
16 October 2025
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDD9877
291915
Flag
UNITED STATES
367317520
Maury page id
psix-291915

Inspections, by type

…with no type recorded3
Years with a record 32 calendar years (1988–2025)
The 60 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)29.0 ft × 12.0 ft × 5.0 ft
Registered tonnagegross 11 / net 9
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderISLAND HOPPER, INC. · MARATHON SHORES, FL, UNITED STATES · built 1987
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portST CROIX, VI
Trade endorsementsCoastwise, unrestricted, Recreational, Registry
DocumentationValid · issued 18 June 2026 · expires 31 May 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it11 - Simplified, Gross Ton
9 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDD9877MMSI 367317520 · active · compulsorily equipped · granted 1 March 2018, expires 20 March 2028
WDB2579MMSI 369228000 · expired · compulsorily equipped · granted 24 December 2002, cancelled 23 February 2013 · licensed under a name not among this hull’s recorded names (not shown)
WDA3622MMSI 366800380 · expired · compulsorily equipped · granted 9 February 2001, cancelled 16 April 2011 · licensed under a name not among this hull’s recorded names (not shown)
WAL5077MMSI not assigned · expired · compulsorily equipped · granted 28 June 1995, cancelled 7 January 2006 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 60

16 October 2025 Administrative Inspection · Deficiency Check · Annual Inspection
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 8251368
24 September 2025 Examination of Repairs · Hull Examination · Internal Structural Exam · Damage Survey · Deficiency Check · Administrative Inspection
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 8238500
20 August 2024 Annual Inspection
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 7982985
4 October 2023 Administrative Inspection · Annual Inspection · Deficiency Check
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 7800478
29 August 2023 Deficiency Check · Drydock Exam · Administrative Inspection · In-Service Inspection
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 7780158
26 August 2022 Deficiency Check
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 7535210
12 August 2022 COI Inspection
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 7524742
14 February 2022 Administrative Inspection
Administrative · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 7396020
31 January 2022 Deficiency Check
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 7388051
26 January 2022 Annual Inspection
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 7384463
17 September 2021 Deficiency Check · Drydock Exam
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 7312820
27 August 2020 Annual Inspection · Administrative Inspection
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 7041421
13 November 2019 DAPI Audit · Annual Inspection
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 6853927
19 September 2019 Internal Structural Exam · Drydock Exam
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 6815807
25 April 2019 Annual Inspection · DAPI Audit
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 6669475
17 April 2019 Administrative Inspection · Deficiency Check
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 6664366
16 October 2017 COI Inspection · Deficiency Check
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 6296256
7 October 2016 Internal Structural Exam · DAPI Audit · Annual Inspection
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 6020078
4 November 2015 Drydock Exam
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 5757798
30 October 2015 Annual Inspection
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 5755361
21 December 2010 Deficiency Check
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 3914221
24 November 2010 Annual Inspection
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 3898185
12 November 2008 Annual Inspection
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 3361352
10 October 2007 Hull Examination · COI Inspection · Administrative Inspection
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 3076755
27 October 2006 Annual Inspection
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 2861055
24 October 2005 Periodic Inspection
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 2526374
26 July 2005 Hull Examination
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 2439239
14 July 2005 Administrative Inspection
Administrative · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 2426431
2 December 2004 Annual Inspection
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 2263126
7 May 2004 Deficiency Check
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 2079632
27 October 2003 COI Inspection
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 1936609
5 June 2003 Administrative Inspection
Administrative · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 1810132
1 April 2002 Hull Examination
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 1597710
1 April 2002 Hull Examination · Deficiency Check
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 1600373
10 January 2002 Deficiency Check
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 1477490
23 November 2001 Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1076491
8 November 2001 COI Inspection · Hull Examination
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1432581
8 November 2001 COI Inspection
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 1703860
19 May 2001 Type not recorded
No type recorded · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 504666
18 April 2001 Re-Inspection
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1389357
7 April 2000 Hull Examination · COI Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 1457773
22 April 1999 Plan Review "T" Boat · Re-Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 1126650
20 July 1998 Deficiency Check
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 1130351
22 June 1998 Re-Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 793026
19 June 1997 COI Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 1407911
2 July 1996 Re-Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 1089685
2 May 1995 Re-Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 1409282
12 April 1995 Hull Examination
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 848797
8 June 1994 COI Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 1412660
13 July 1993 Administrative
Administrative · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 843938
15 June 1993 Re-Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 841477
2 October 1992 Type not recorded
No type recorded · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 226024
13 August 1992 Type not recorded
No type recorded · MSO CLEVELAND · USCG Great Lakes District (CGD-GL) · Activity 69198
13 May 1992 Re-Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 956269
11 April 1991 COI Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 1213774
2 July 1990 Deficiency Check
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 914350
18 April 1990 Re-Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 930134
4 April 1990 Hull Examination
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 1217993
22 March 1989 Re-Inspection
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1210556
23 February 1988 Initial Certification
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1028041

Deficiency record · 80

11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 16 October 2025 Resolved
Each ring life buoy on a vessel must be approved in accordance with 46 CFR 160.050 in Subchapter Q. The ring buoy's retro-reflective tape was deteriorated.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 October 2025
Resolved 31 October 2025
Resolution: New retro-reflective tape has been applied to the ring buoy.
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Other (Conditions of employment)
Issued 16 October 2025 Resolved
A marine employer shall comply with the requirements of 46 CFR 4.06. The marine employer must have a sufficient number of alcohol testing devices readily accessible on board the vessel to determine the presence of alcohol in the system of each individual who was directly involved in a Serious Marine Incident. The vessel could not produce alcohol testing devices for all crewmembers serving on board.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 November 2025
Resolved 22 January 2026
Resolution: The Frederiksted office now maintains alcohol test strips for the vessel.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 16 October 2025 Resolved
A vessel must carry adequate and up-to-date U.S. Coast Pilot or similar publication, Coast Guard Light List, and tide tables. The required publications were not maintained on board.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 October 2025
Resolved 22 October 2025
Resolution: Hard copies of the navigation publications are now maintained on board the vessel.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 16 October 2025 Resolved
A vessel must carry either a first-aid kit that meets the requirements in 46 CFR 199.175(b)(10) or a kit with equivalent contents and instructions. The aspirin contained in the vessel's first aid kit was found to be expired by nearly two years.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 October 2025
Resolved 22 October 2025
Resolution: New acetaminophen (expiring APR2028) is now maintained on board the vessel.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 5 October 2023 Resolved
A visual and audible alarm must be provided at the operating station to indicate a high water level in each normally unmanned space. Both FWD alarms only have working audible alarms and visual is not working. Repair visual alarms.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 November 2023
Resolved 1 November 2023
Resolution: Observed both audible and visual bilge alarms in good working order.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 5 October 2023 Resolved
A vessel not required to have a power driven fire pump must have at least 3 two and half gallon fire buckets. Vessel only had 2 fire buckets.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 November 2023
Resolved 1 November 2023
Resolution: Observed 3 fire buckets located on vessel.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 5 October 2023 Resolved
As appropriate for the intended voyage a vessel must carry adequate and up-to-date CG light list and current tide tables and current tables. Vessel had out dated tables. Renew tables.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 November 2023
Resolved 1 November 2023
Resolution: Observed updated tides and currents located on vessel.
01 - Certificates & Documentation › 012 - Crew Certificates › Other (STCW)
Issued 5 October 2023 Resolved
A vessel must comply with the applicable requirements for a station license and installation certificates to be issued by the FCC as set forth in 47 CFR part 80. Vessel is required to have a crew member with a valid FFC operators license. Captain needs FCC operators permit.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 November 2023
Resolved 1 November 2023
Resolution: Captain has completed FCC operators permit.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Bulwarks and freeing ports
Issued 12 August 2022 Resolved
The freeing ports or scuppers on a well deck vessel must be located to allow rapid clearing of water in all probable conditions of list and trim. Remove wood from rubber paneling to allow rapid clearing of water.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 September 2022
Resolved 26 August 2022
Resolution: Wood has been removed from freeing ports.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 12 August 2022 Resolved
Portable fire extinguishers must be located so that they are clearly visible and ready accessible from the space being protected. The installation and location must be to the satisfaction of the Officer in Charge, Marine Inspection. Proper mounts/supporting brackets need to be used.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 September 2022
Resolved 26 August 2022
Resolution: Proper mounts have been installed on vessel.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 12 August 2022 Resolved
An adult life jacket must be provided for each person carried on board a vessel. (01) adult life jacket has been found in a dilapidated state and not fit for service. Replace jacket, passenger count is now 17.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 September 2022
Resolved 26 August 2022
Resolution: 04 new life jackets have been placed on vessel.
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 12 August 2022 Resolved
Remote fuel shutoff stations must be marked in clearly legible letters at least 1 inch high indicating purpose of value and direction of operation.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 September 2022
Resolved 26 August 2022
Resolution: Remote F/O shut off valve has been labeled correctly.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 26 January 2022 Resolved
An adult life jacket must be provided for each person carried on board a vessel. 01 adult life jacket has been found in a dilapidated state not fit for service.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 February 2022
Resolved 8 February 2022
Resolution: New life jacket has been placed on board vessel.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 26 January 2022 Resolved
A vessel must carry one floating water light, unless it is limited to day time operation. Water light needs to have its battery replaced.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 February 2022
Resolved 8 February 2022
Resolution: Vessel has purchased and installed on board a new floating water light.
01 - Certificates & Documentation › 012 - Crew Certificates › Other (STCW)
Issued 26 January 2022 Resolved
A vessel must comply with the applicable requirements for a station license and installation certificates to be issued by the FCC as set forth in 47 CFR part 80. Vessel is required to have a crew member with a valid FCC operators license.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 February 2022
Resolved 8 February 2022
Resolution: Vessel has presented a valid FCC operators license.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 27 August 2020 Resolved
Stern light inoperable.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 September 2020
Resolved 1 September 2020
Resolution: Stern light bulb replaced.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 27 August 2020 Resolved
Life ring light inoperable.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 September 2020
Resolved 1 September 2020
Resolution: Life ring light battery replaced.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 27 August 2020 Resolved
Life ring was too small for vessel size.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 September 2020
Resolved 1 September 2020
Resolution: New 26" life ring was placed in proper service.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 27 August 2020 Resolved
Drug and alcohol MIS report not available for inspection.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 September 2020
Resolved 1 September 2020
Resolution: MIS report was available for review.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 27 August 2020 Resolved
Adult and child lifejackets not seperated.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 September 2020
Resolved 1 September 2020
Resolution: Lifejackets were seperated and labeled properly.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 27 August 2020 Resolved
Donning placard not posted.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 September 2020
Resolved 1 September 2020
Resolution: Donning placard posted.
04 - Emergency Systems › N/A - No Subsystem › Water level indicator
Issued 27 August 2020 Resolved
Fwd/ engine room bilge alarm audible but not visual.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 September 2020
Resolved 1 September 2020
Resolution: Fwd/ engine room bilge alarm visual indicator bulbs replaced.
10 - Safety of Navigation › N/A - No Subsystem › Magnetic compass
Issued 27 August 2020 Resolved
There was no light for the compass.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 September 2020
Resolved 1 September 2020
Resolution: Flashlight was placed near the compass for use if operated at night.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 13 November 2019 Resolved
The emergency fuel shutdown did not operate within a reasonable amount of time. Require vessel to fix system and retest.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 December 2019
Resolved 20 November 2019
Resolution: Tested shutdown. Engine shuts down within a few seconds.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 25 April 2019 Resolved
The installed fixed fire fighting system had not been tested/inspected by a certified entity since 2017.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 25 May 2019
Resolved 25 April 2019
Resolution: Installed fixed fire fighting system was inspected and certified shortly after the inspection had concluded.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 25 April 2019 Resolved
The portable fire extinguishers on board the vessel had not been annually tested since 2017.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 25 May 2019
Resolved 25 April 2019
Resolution: Portable fire extinguishers were inspected/certified shortly after the inspection had concluded.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 25 April 2019 Resolved
Lifejacket donning placard was missing for the 02 types of life jackets on board.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 May 2019
Resolved 25 April 2019
Resolution: Life jacket placards were placed and mounted same day.
01 - Certificates & Documentation › 012 - Crew Certificates › Certificates for master and officers
Issued 25 April 2019 Resolved
Vessel could not provide proof of crew enrollment in the DAPI program.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 May 2019
Resolved 1 May 2019
Resolution: Provided proof of enrollment.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 25 April 2019 Resolved
Vessel had outdated items in its first aid kit.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 May 2019
Resolved 15 May 2019
Resolution: Resolved.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 17 April 2019 Resolved
Vessel missed its last annual inspection.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 17 April 2019
Resolved 25 April 2019
Resolution: INspection complete.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 19 October 2017 Resolved
Repair inoperable port side navigation light.
Action required: 705 - Other - as specified
Due 27 October 2017
Resolved 26 October 2017
Resolution: Nav lights repaired.
Documentation › Certificates/Documents › FCC Safety Radiotelephony Certificate
Issued 16 October 2017 Resolved
Obtain valid FCC Safety Radiotelephony Certificate.
Action required: 705 - Other - as specified
Due 13 November 2017
Resolved 25 April 2019
Lifesaving › Lifebuoys › Serviceable
Issued 16 October 2017 Resolved
Replace unserviceable throwable life ring.
Action required: 705 - Other - as specified
Due 27 October 2017
Resolved 26 October 2017
Resolution: Life ring replaced and verified by CGMI.
Documentation › Certificates/Documents › FCC SSL
Issued 16 October 2017 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 705 - Other - as specified
Due 13 November 2017
Resolved 28 December 2017
Resolution: Replace life ring with new one.
Engineering › Fuel Oil Storage/Transfer System › Tank
Issued 16 October 2017 Resolved
Fuel tank contains unauthorized epoxy repair. Make fuel tank available for inspection.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 31 December 2017
Resolution: Repaired fuel tank
Engineering › Fuel Oil Service System › Filter
Issued 16 October 2017 Resolved
Add metal heat shield to plastic bowl of first-stage fuel filter.
Action required: 705 - Other - as specified
Due 13 November 2017
Resolved 31 December 2017
Resolution: Filter meets manufactures specs.
Communications › Radio Communications › VHF Radiotelephone
Issued 30 October 2015 Resolved
Master does not have FCC Marine Radio Operators Permit.
Action required: 705 - Other - as specified
Due 30 November 2015
Resolved 10 December 2015
Resolution: FCC MROP provided
Operations/Management › Drills/Instruction › Fire
Issued 30 October 2015 Resolved
Vessel did not have current drill logs. Provide current drill log.
Action required: 705 - Other - as specified
Due 30 November 2015
Resolved 10 December 2015
Resolution: Drill logs provided.
Navigation › Piloting/Steering › Coast Guard Light List
Issued 30 October 2015 Resolved
Provide current light list/tide tables.
Action required: 705 - Other - as specified
Due 30 November 2015
Resolved 10 December 2015
Resolution: Light list/tide tables provided
Navigation › Piloting/Steering › Marine Charts
Issued 30 October 2015 Resolved
Provide current marine charts.
Action required: 705 - Other - as specified
Due 30 November 2015
Resolved 10 December 2015
Resolution: Marine cahrts provided.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 24 November 2010 Resolved
Vessel engine fix extinguishing system was not service. see additional comment in the narrative.
Action required: 705 - Other - as specified
Due 4 December 2010
Resolved 21 December 2010
Resolution: System was inspected
Pollution Prevention/Response › Prevention Equipment › Bilge Monitor
Issued 24 November 2010 Resolved
Installed a bilge alarm in the foward compartment.
Action required: 705 - Other - as specified
Due 4 December 2010
Resolved 21 December 2010
Resolution: Bilge alarm installed.
Communications › Alarms/Indicators › Fire Alarm
Issued 12 November 2008 Resolved
The FIREBOY E/R system works in the normal condition but when tested there is no audible alarm sounded. Prove proper operation of audible alarm when fire system is tested.
Due 26 November 2008
Resolved 2 February 2009
Resolution: New FIREBOY alarm installed.
Communications › Alarms/Indicators › High Water Alarm
Issued 12 November 2008 Resolved
The high water alarm in the aft compartment does not sound when tested. Prove proper operation with audible and visual alarm for the aft compartment high water alarm.
Due 19 November 2008
Resolved 4 December 2008
Resolution: Received call from master, he had installed a new high water alarm and it was operational.
Fire Fighting › Fire Bucket › Availability
Issued 10 October 2007 Resolved
Provide fire buckets
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 25 January 2008
Resolution: Fire bucket has been provided. Def Cleared
Fire Fighting › Fixed Gas Fire Extinguishing System › Tanks
Issued 10 October 2007 Resolved
Prior to carrying passengers for hire, provide evidence of satisfactory maintenance of the fixed firefighting system.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 25 January 2008
Lifesaving › Lifejacket/PFD (General) › Marking
Issued 10 October 2007 Resolved
Properly mark PFD's with vessel names.
Condition: Unknown
Due 19 October 2007
Resolved 25 January 2008
Resolution: life jackets have been labeled with vessels name. Def. Cleared
Lifesaving › Lifejacket/PFD (General) › Quantity
Issued 10 October 2007 Resolved
Provide one additional PFD. Until corrected the vessel is limited to 19 passengers.
Condition: Unknown
Action required: 705 - Other - as specified
Resolved 25 January 2008
Resolution: additional life jackets are on board. Def. Cleared
Documentation › Certificates/Documents › FCC SSL
Issued 10 October 2007 Resolved
Update FCC documents to reflect new vessel name, owner and operator.
Condition: Unknown
Action required: 705 - Other - as specified
Resolved 25 January 2008
Resolution: FCC Document has been updated to reflect vessels name, owner and operator. Def. Cleared
Communications › Radio Communications › EPIRB
Issued 10 October 2007 Resolved
Renew EPIRB hydrostatic release. Until corrected vessel is restricted to Lakes, Bays and Sounds.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 25 January 2008
Resolved 25 January 2008
Resolution: Vessels Hydrostatic release has been renewed. Def. Cleared
Operations/Management › Navigation Safety › Proper Use of Navigation/Anchor Lights
Issued 10 October 2007 Resolved
Renew stern light. Until corrected, vessel is restricted to daylight operation only.
Condition: Unknown
Action required: 705 - Other - as specified
Resolved 25 January 2008
Resolution: Stern light is operational. Def. Cleared
Communications › Radio Communications › EPIRB
Issued 14 July 2005 Resolved
Properly service the EPIRB. Until corrected vessel is restricted to less than three miles from shore.
Action required: 705 - Other - as specified
Resolved 14 July 2005
Fire Fighting
Issued 27 October 2003 Resolved
Prior to carrying passengers for hire, recharge or renew portable fire extinguishers.
Due 28 October 2003
Resolved 28 October 2003
Lifesaving
Issued 8 November 2001 Resolved
Provide evidence of compliance with 46 CFR 185 subpart G.
Condition: Unknown
Due 8 December 2001
Resolved 10 January 2002
Documentation
Issued 8 November 2001 Resolved
Provide FCC Safety Certificate.
Condition: Unknown
Due 8 December 2001
Resolved 23 November 2001
Navigation
Issued 8 November 2001 Resolved
Make repairs to sound producing devices.
Condition: Unknown
Due 8 December 2001
Resolved 10 January 2002
Engineering
Issued 8 November 2001 Resolved
Make engine space vapor tight.
Condition: Unknown
Due 8 December 2001
Resolved 10 January 2002
Construction/Loadline
Issued 8 November 2001 Resolved
Make hatches watertight and add capture devices.
Condition: Unknown
Due 8 December 2001
Resolved 10 January 2002
Construction/Loadline
Issued 8 November 2001 Resolved
Provide closure for engine room vents.
Condition: Unknown
Due 8 December 2001
Resolved 10 January 2002
Documentation
Issued 8 November 2001 Resolved
PROVIDE EVIDENCE OF COMPLIANCE WITH CHEMICAL TESTING PROGRAM.
Condition: Unknown
Due 8 December 2001
Resolved 23 November 2001
System not recorded
Issued 8 November 2001 Resolved
Return vessel to stability test conditions. (Remove awning)
Condition: Unknown
Due 8 December 2001
Resolved 8 November 2001
Navigation
Issued 8 November 2001 Resolved
Make repairs to stern and anchor lights.
Condition: Unknown
Due 8 December 2001
Resolved 10 January 2002
Engineering
Issued 8 November 2001 Resolved
Renew fuel shutoff valves iaw 46 CFR 182.455 (b)(4).
Condition: Unknown
Due 8 December 2001
Resolved 10 January 2002
Lifesaving
Issued 18 April 2001 Resolved
Procure proper container for flares. Mark same "Distress Signals".
Condition: Unknown
Due 7 May 2001
Resolved 7 May 2001
Navigation
Issued 18 April 2001 Resolved
Prove proper operation of horn
Condition: Unknown
Due 20 April 2001
Resolved 20 April 2001
Electrical
Issued 18 April 2001 Resolved
Label all breakers
Condition: Unknown
Due 7 May 2001
Resolved 7 May 2001
Unknown
Issued 18 April 2001 Resolved
Procure training log
Condition: Unknown
Due 7 May 2001
Resolved 7 May 2001
Lifesaving
Issued 18 April 2001 Resolved
Vessel limited to carriage of 20 adults and 2 children pending proof of purchase or repair of 2 more adult and 2 more child's lifejackets.
Condition: Unknown
Due 7 May 2001
Resolved 7 May 2001
Lifesaving
Issued 18 April 2001 Resolved
Procure current contents for first aid kit.
Condition: Unknown
Due 7 May 2001
Resolved 7 May 2001
Navigation
Issued 18 April 2001 Resolved
Prove proper operation of emergency steering tiller.
Condition: Unknown
Due 7 May 2001
Resolved 7 May 2001
Unknown
Issued 18 April 2001 Resolved
Procure bridge log
Condition: Unknown
Due 7 May 2001
Resolved 7 May 2001
Navigation
Issued 18 April 2001 Resolved
provide proof of possession of light list and appropriate charts for route
Condition: Unknown
Due 7 May 2001
Resolved 7 May 2001
Navigation
Issued 18 April 2001 Resolved
Prove proper operation of compass light
Condition: Unknown
Due 7 May 2001
Resolved 7 May 2001
Lifesaving
Issued 22 June 1998 Resolved
PLACE 02 OARS FOR EACH LIFE FLOAT ON BOARD (4 TOTAL OARS/PADDLES)
Condition: Unknown
Due 22 June 1998
Resolved 22 June 1998
Engineering
Issued 2 July 1996 Resolved
REMOVE EXISTING FLEXIBLE FUEL HOSES WITH RADIATOR TYPE CLAMPS AND INSTALL NEW FLEXIBLE FUEL LINES WITH PROPER CONNECTIONS.
Condition: Unknown
Due 2 July 1996
Resolved 2 July 1996
Engineering
Issued 2 July 1996 Resolved
REROUTE L/O PSI GAUGE LINE TO SHORTEN LENGTH OF FLEXIBLE HOSE REQUIRED, REMOVE EXISTING FLEXIBLE HOSE WITH RADIATOR TYPE CLAMPS, AND INSTALL NEW FLEXIBLE L/O LINE WITH PROPER CONNECTIONS.
Condition: Unknown
Due 2 July 1996
Resolved 2 July 1996
Lifesaving
Issued 13 May 1992 Resolved
6 orange smoke flares have expiration dates of APR 92. Owner stated that new ones were on order, but had not yet arrived._x001C_
Condition: Unknown
Due 13 May 1992
Resolved 13 May 1992
Fire Fighting
Issued 13 May 1992 Resolved
Fire extinguisher was serviced in May 1992, however indicator dial showed that extinguisher was in need of recharge._x001C_
Condition: Unknown
Due 13 May 1992
Resolved 13 May 1992
Lifesaving
Issued 18 April 1990 Resolved
SHOW PROPER OPERATION OF RING BUOY LIGHT IAW 46CFR180.30. UNTIL THIS ITEM IS CORRECTED, THIS VESSEL IS RESTRICTED TO DAYLIGHT HOURS ONLY.
Condition: Unknown
Due 18 April 1990
Resolved 18 April 1990
Construction/Loadline
Issued 18 April 1990 Resolved
PROVIDE EXHAUST/INTAKE FOR E/R, FUEL SPACE IAW 46CFR182.20-45.
Condition: Unknown
Due 18 April 1990
Resolved 18 April 1990

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.