MAURY USCG vessel records
← All vessels

QUIET HEART

QUIET HEART is a 1987 passenger vessel (inspected). The Coast Guard has recorded 18 inspections since 2016, most recently in April 2026, along with 29 deficiencies.

Records from 2016 to 2026. Most recent: inspection, 23 April 2026.

Built
1987
Last inspected
23 April 2026
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 23 April 2026
Operational controls None recorded without a removal date
Years with a record 11 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDC9554
292035
Flag
UNITED STATES
Maury page id
psix-292035

Documentation record

Registered dimensions (L × B × D)78.2 ft × 20.0 ft × 9.3 ft
Registered tonnagegross 97 / net 77
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderMCQUEEN'S BOAT WORKS, LTD · SURREY, BRITISH COLUMBIA, CANADA · built 1987
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portDALLAS, TX
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 7 May 2026 · expires 31 May 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it97 - Simplified, Gross Ton
77 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report

A report is not offered for this hull. Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 18

23 April 2026 Drydock Exam · Deficiency Check · Internal Structural Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8354536
8 April 2026 COI Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8334466
7 April 2025 Deficiency Check · Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8108116
20 May 2024 Annual Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7915592
24 April 2024 Drydock Exam · Internal Structural Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7900672
28 June 2023 Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7725579
16 May 2022 Deficiency Check · Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7489085
15 March 2022 Drydock Exam · Internal Structural Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7424942
8 April 2021 COI Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7169852
17 March 2021 Deficiency Check · In-Service Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7158059
2 September 2020 Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7048459
6 March 2020 Deficiency Check · Drydock Exam · Internal Structural Exam · Hull Examination
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6922104
10 July 2019 Deficiency Check · Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6743821
10 July 2018 Administrative Inspection · Annual Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6474116
7 March 2018 Drydock Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6367483
10 May 2017 Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6144296
6 April 2016 Deficiency Check · COI Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 5848334
10 March 2016 Hull Examination · Internal Structural Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 5830653

Deficiency record · 29

09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 23 April 2026 Resolved
Vessel has 12 overboard fittings at the water line. Remove all un-capped valves to prove proper operation.
Action required: 705 - Other - as specified
Resolved 27 April 2026
Resolution: Through hull vlalves were installed.
10 - Safety of Navigation › N/A - No Subsystem › Magnetic compass
Issued 7 April 2025 Resolved
Compass light was not working. Vessel is to repair or replace compass, prior to operating in low light conditions. 46CFR184.402(c)
Action required: 705 - Other - as specified
Resolved 24 April 2025
Resolution: Images provided. All SAT
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 20 May 2024 Resolved
Provide vessel wih DSC-VHF radio. Radio shall be programmed with MMSI number and display lat/long.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 June 2024
Resolved 6 June 2024
Resolution: Received photo of new radio installed with lat/long/MMSI
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 20 May 2024 Resolved
Provide galley space with an operable smoke detector.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 June 2024
Resolved 6 June 2024
Resolution: Received photo of smoke detector installed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 16 May 2022 Resolved
A vessel must be provided with a satisfactory arrangement for draining any watertight compartment. Troubleshoot and repair inoperable bilge pump.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 May 2022
Resolution: Vessel rep repaired inoperable bilge pump.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 16 May 2022 Resolved
Water Pumps in the engine room port side found to be not secured. Secure pumps to prevent movement.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 May 2022
Resolved 20 May 2022
Resolution: Vessel rep. bolted pumps in place.
07 - Fire Safety › N/A - No Subsystem › Fire-dampers
Issued 8 April 2021 Resolved
Service stbd engine compartment ventilation closure. Closure would not actuate when release pin was pulled.
Action required: 705 - Other - as specified
Resolved 20 April 2021
Resolution: Vessel rep provided video of the closure properly closing.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 8 April 2021 Resolved
Replace all welding cable with appropriate sized boat cable in vessel's direct current systems. Areas welding cables were found: stbd generator, stbd battery bank, port battery bank, both main engine starters.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 May 2021
Resolved 20 May 2021
Resolution: Vessel rep provided photo's of new battery cable installed.
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 8 April 2021 Resolved
Replace plastic rubber hose on fuel tank with tubular gauge glasses, if fitted to diesel fuel tanks, must be of heat resistant materials, adequately protected from mechanical damage, and provided at the tank connections with devices that will automatically close in the event of rupture of the gauge or gauge lines.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 May 2021
Resolved 20 May 2021
Resolution: Vessel rep provided photo of new sight glass installed.
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 8 April 2021 Resolved
Provide lazarette bilge suction pickup with screen.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 May 2021
Resolved 4 May 2021
Resolution: Received photo of corrected def.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 8 April 2021 Resolved
Repair piping leak at union on fire main suction piping.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 May 2021
Resolved 20 May 2021
Resolution: Fire main piping was tightened and confirmed by vessel rep to be free of leaks.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 8 April 2021 Resolved
Terminate or remove dead ended cables port side engine compartment, above batteries.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 May 2021
Resolved 4 May 2021
Resolution: Received photo of corrected def.
09 - Working and Living Conditions › 091 - Living Conditions › Other (food)
Issued 8 April 2021 Resolved
Properly mount refrigerator in galley.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 May 2021
Resolved 4 May 2021
Resolution: Received photo of corrected def.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 8 April 2021 Resolved
Repair fire extinguisher bracket on upper deck.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 May 2021
Resolved 4 May 2021
Resolution: Received photo of corrected def.
09 - Working and Living Conditions › 091 - Living Conditions › Other (crew and accommodation)
Issued 8 April 2021 Resolved
Repair loose step leading to upper deck, 2nd step up from main deck.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 May 2021
Resolved 4 May 2021
Resolution: Received photo of corrected def.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 8 April 2021 Resolved
Replace inoperable modular smoke detectors in galley and accommodation spaces.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 May 2021
Resolved 4 May 2021
Resolution: Received photo of corrected def.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 8 April 2021 Resolved
Install missing fire extinguisher in galley area.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 May 2021
Resolved 4 May 2021
Resolution: Received photo of corrected def.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 8 April 2021 Resolved
Removed 01 life jacket from service for broken clip. Provide additonal life jacket.
Action required: 10 - Deficiency Rectified
Resolved 8 April 2021
Resolution: Vessel rep provided additional life jacket.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 8 April 2021 Resolved
Provide first aid kit with instructions.
Action required: 10 - Deficiency Rectified
Resolved 8 April 2021
Resolution: Vessel rep provided instructions
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 17 March 2021 Resolved
Generators 1 and 2 amperage meters were not operational, repair or replace then prove proper operation of amp meters.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 April 2021
Resolved 8 April 2021
Resolution: Amp meter selector switch was replaced, test sat.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 17 March 2021 Resolved
Generators 1 and 2 are wired with over current protection via 100 amp breakers. Nameplate data shows generators are rated for 83 amps at full load. Over current protection cannot exceed 115% of full load rating. Provide both generators with over current protection of 90 amps or less.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 April 2021
Resolved 8 April 2021
Resolution: 90 amp breakers were installed for each generator.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 6 March 2020 Resolved
Mount J box to bulkhead.
Action required: 705 - Other - as specified
Due 16 March 2020
Resolved 16 March 2020
Resolution: Mounted.
08 - Alarms › N/A - No Subsystem › Closing water-tight doors alarm
Issued 10 July 2019 Resolved
Repair/replace watertight door alarm.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 July 2019
Resolved 12 August 2019
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 10 July 2018 Resolved
SERVICE 01 ADDITIONAL FIRE EXTINGUISHERS FROM TOP DECK.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 July 2018
Resolved 13 July 2018
Resolution: Fire extinguisher serviced.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 10 July 2018 Resolved
DEAD END WIRE FOUND IN FWD ACCOM. REMOVE WIRING, PROPERLY TERMINATE IN J-BOX OR REPAIR LIGHTING.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 July 2018
Resolved 20 July 2018
Resolution: Received e-mail and spoke with POC. Dead-end wires removed back to the next J-box.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 10 July 2018 Resolved
RE-INSTALL BRACKET FOR FIRE EXTINGUISHER IN FWD ACCOM.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 July 2018
Resolved 13 July 2018
Resolution: Bracket reinstalled.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 10 July 2018 Resolved
BATTERY BOX PORT SIDE E/R ROTTED. PLACE BATTERIES IN PROPER BATTERY BOX.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 July 2018
Resolved 13 July 2018
Resolution: New battery boxes installed
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 10 July 2018 Resolved
INSPECT FLOW TO STBD PROPULSION ENGINE EXHAUST DUE TO HOT SPOT.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 July 2018
Resolved 20 July 2018
Resolution: Received e-mail and spoke to POC. Wet exhaust system cleaned out, pin hole at connection welded. Engine tested. Water flow and temperature on piping satisfactory.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 11 April 2016 Resolved
Provide proper stern light prior to operating between dusk and dawn.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 12 April 2016
Resolution: A new qualifying stern light was installed