Records from 2016 to 2026. Most recent: inspection, 23 April 2026.
Inspection history · 18
23 April 2026
Drydock Exam · Deficiency Check · Internal Structural Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8354536
8 April 2026
COI Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8334466
7 April 2025
Deficiency Check · Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8108116
20 May 2024
Annual Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7915592
24 April 2024
Drydock Exam · Internal Structural Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7900672
28 June 2023
Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7725579
16 May 2022
Deficiency Check · Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7489085
15 March 2022
Drydock Exam · Internal Structural Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7424942
8 April 2021
COI Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7169852
17 March 2021
Deficiency Check · In-Service Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7158059
2 September 2020
Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7048459
6 March 2020
Deficiency Check · Drydock Exam · Internal Structural Exam · Hull Examination
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6922104
10 July 2019
Deficiency Check · Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6743821
10 July 2018
Administrative Inspection · Annual Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6474116
7 March 2018
Drydock Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6367483
10 May 2017
Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6144296
6 April 2016
Deficiency Check · COI Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 5848334
10 March 2016
Hull Examination · Internal Structural Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 5830653
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 23 April 2026
Resolved
Vessel has 12 overboard fittings at the water line. Remove all un-capped valves to prove proper operation.
Action required: 705 - Other - as specified
Resolved 27 April 2026
Resolution: Through hull vlalves were installed.
10 - Safety of Navigation › N/A - No Subsystem › Magnetic compass
Issued 7 April 2025
Resolved
Compass light was not working. Vessel is to repair or replace compass, prior to operating in low light conditions.
46CFR184.402(c)
Action required: 705 - Other - as specified
Resolved 24 April 2025
Resolution: Images provided. All SAT
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 20 May 2024
Resolved
Provide vessel wih DSC-VHF radio. Radio shall be programmed with MMSI number and display lat/long.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 June 2024
Resolved 6 June 2024
Resolution: Received photo of new radio installed with lat/long/MMSI
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 20 May 2024
Resolved
Provide galley space with an operable smoke detector.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 June 2024
Resolved 6 June 2024
Resolution: Received photo of smoke detector installed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 16 May 2022
Resolved
A vessel must be provided with a satisfactory arrangement for draining any watertight compartment.
Troubleshoot and repair inoperable bilge pump.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 May 2022
Resolution: Vessel rep repaired inoperable bilge pump.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 16 May 2022
Resolved
Water Pumps in the engine room port side found to be not secured. Secure pumps to prevent movement.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 May 2022
Resolved 20 May 2022
Resolution: Vessel rep. bolted pumps in place.
07 - Fire Safety › N/A - No Subsystem › Fire-dampers
Issued 8 April 2021
Resolved
Service stbd engine compartment ventilation closure. Closure would not actuate when release pin was pulled.
Action required: 705 - Other - as specified
Resolved 20 April 2021
Resolution: Vessel rep provided video of the closure properly closing.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 8 April 2021
Resolved
Replace all welding cable with appropriate sized boat cable in vessel's direct current systems. Areas welding cables were found: stbd generator, stbd battery bank, port battery bank, both main engine starters.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 May 2021
Resolved 20 May 2021
Resolution: Vessel rep provided photo's of new battery cable installed.
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 8 April 2021
Resolved
Replace plastic rubber hose on fuel tank with tubular gauge glasses, if fitted to diesel fuel tanks, must be of heat resistant materials, adequately protected from mechanical damage, and provided at the tank connections with devices that will automatically close in the event of rupture of the gauge or gauge lines.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 May 2021
Resolved 20 May 2021
Resolution: Vessel rep provided photo of new sight glass installed.
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 8 April 2021
Resolved
Provide lazarette bilge suction pickup with screen.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 May 2021
Resolved 4 May 2021
Resolution: Received photo of corrected def.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 8 April 2021
Resolved
Repair piping leak at union on fire main suction piping.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 May 2021
Resolved 20 May 2021
Resolution: Fire main piping was tightened and confirmed by vessel rep to be free of leaks.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 8 April 2021
Resolved
Terminate or remove dead ended cables port side engine compartment, above batteries.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 May 2021
Resolved 4 May 2021
Resolution: Received photo of corrected def.
09 - Working and Living Conditions › 091 - Living Conditions › Other (food)
Issued 8 April 2021
Resolved
Properly mount refrigerator in galley.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 May 2021
Resolved 4 May 2021
Resolution: Received photo of corrected def.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 8 April 2021
Resolved
Repair fire extinguisher bracket on upper deck.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 May 2021
Resolved 4 May 2021
Resolution: Received photo of corrected def.
09 - Working and Living Conditions › 091 - Living Conditions › Other (crew and accommodation)
Issued 8 April 2021
Resolved
Repair loose step leading to upper deck, 2nd step up from main deck.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 May 2021
Resolved 4 May 2021
Resolution: Received photo of corrected def.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 8 April 2021
Resolved
Replace inoperable modular smoke detectors in galley and accommodation spaces.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 May 2021
Resolved 4 May 2021
Resolution: Received photo of corrected def.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 8 April 2021
Resolved
Install missing fire extinguisher in galley area.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 May 2021
Resolved 4 May 2021
Resolution: Received photo of corrected def.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 8 April 2021
Resolved
Removed 01 life jacket from service for broken clip. Provide additonal life jacket.
Action required: 10 - Deficiency Rectified
Resolved 8 April 2021
Resolution: Vessel rep provided additional life jacket.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 8 April 2021
Resolved
Provide first aid kit with instructions.
Action required: 10 - Deficiency Rectified
Resolved 8 April 2021
Resolution: Vessel rep provided instructions
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 17 March 2021
Resolved
Generators 1 and 2 amperage meters were not operational, repair or replace then prove proper operation of amp meters.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 April 2021
Resolved 8 April 2021
Resolution: Amp meter selector switch was replaced, test sat.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 17 March 2021
Resolved
Generators 1 and 2 are wired with over current protection via 100 amp breakers. Nameplate data shows generators are rated for 83 amps at full load. Over current protection cannot exceed 115% of full load rating. Provide both generators with over current protection of 90 amps or less.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 April 2021
Resolved 8 April 2021
Resolution: 90 amp breakers were installed for each generator.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 6 March 2020
Resolved
Mount J box to bulkhead.
Action required: 705 - Other - as specified
Due 16 March 2020
Resolved 16 March 2020
Resolution: Mounted.
08 - Alarms › N/A - No Subsystem › Closing water-tight doors alarm
Issued 10 July 2019
Resolved
Repair/replace watertight door alarm.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 July 2019
Resolved 12 August 2019
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 10 July 2018
Resolved
SERVICE 01 ADDITIONAL FIRE EXTINGUISHERS FROM TOP DECK.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 July 2018
Resolved 13 July 2018
Resolution: Fire extinguisher serviced.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 10 July 2018
Resolved
DEAD END WIRE FOUND IN FWD ACCOM. REMOVE WIRING, PROPERLY TERMINATE IN J-BOX OR REPAIR LIGHTING.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 July 2018
Resolved 20 July 2018
Resolution: Received e-mail and spoke with POC. Dead-end wires removed back to the next J-box.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 10 July 2018
Resolved
RE-INSTALL BRACKET FOR FIRE EXTINGUISHER IN FWD ACCOM.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 July 2018
Resolved 13 July 2018
Resolution: Bracket reinstalled.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 10 July 2018
Resolved
BATTERY BOX PORT SIDE E/R ROTTED. PLACE BATTERIES IN PROPER BATTERY BOX.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 July 2018
Resolved 13 July 2018
Resolution: New battery boxes installed
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 10 July 2018
Resolved
INSPECT FLOW TO STBD PROPULSION ENGINE EXHAUST DUE TO HOT SPOT.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 July 2018
Resolved 20 July 2018
Resolution: Received e-mail and spoke to POC. Wet exhaust system cleaned out, pin hole at connection welded. Engine tested. Water flow and temperature on piping satisfactory.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 11 April 2016
Resolved
Provide proper stern light prior to operating between dusk and dawn.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 12 April 2016
Resolution: A new qualifying stern light was installed