Records from 2001 to 2019. Most recent: inspection, 28 May 2019.
Inspection history · 18
28 May 2019
Ballast Water Examination · PII Safety Exam · Deficiency Check · ISPS II Exam · Administrative Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6690092
26 August 2015
In-Service Inspection · COE-Offshore
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5222547
25 August 2015
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5225652
11 January 2012
ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 4217705
13 August 2008
Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 3368415
21 September 2007
PII Safety Exam · ISPS II Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3063178
25 January 2007
Type not recorded
No type recorded · Sector Portland · USCG Northwest District (CGD-NW) · Activity 2861737
22 January 2007
Administrative Inspection
Administrative · Sector Portland · USCG Northwest District (CGD-NW) · Activity 2860083
7 July 2006
Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2705040
7 March 2006
Deficiency Check
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 2596000
6 March 2006
Type not recorded
No type recorded · Sector Portland · USCG Northwest District (CGD-NW) · Activity 2597829
19 February 2006
Type not recorded
No type recorded · Maritime Safety & Security Team LA/LB (91103) · Activity 2588133
17 February 2006
Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2587685
9 February 2006
Random ISPS/MTSA/PSC · Ballast Water Examination
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2582265
15 February 2005
Type not recorded
No type recorded · Sector Astoria · USCG Northwest District (CGD-NW) · Activity 2293292
15 January 2005
PII Safety Exam · Ballast Water Examination
Physical examination · Marine Safety Detachment Kenai · USCG Arctic District (CGD-A) · Activity 2272306
2 August 2004
ISPS II Exam
Physical examination · Marine Safety Detachment Kenai · USCG Arctic District (CGD-A) · Activity 2154062
10 July 2001
Type not recorded
No type recorded · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 291712
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 28 May 2019
Resolved
07113 - THE CONDITION OF THE SHIP AND ITS EQUIPMENT SHALL BE MAINTAINED TO CONFORM WITH THE PROVISIONS OF THE PRESENT REGULATIONS TO ENSURE THAT THE SHIP IN ALL RESPECTS WILL REMAIN FIT TO PROCEED TO SEA WITHOUT DANGER TO SHIP OR PERSONS ON BOARD. PSCO OBSERVED THE EMERGENCY FIRE PUMP LEARNING APPROXIMATELY 03 LITERS PER MINUTE WHILE IN OPERATION. - 74SOLAS(2014)I/11(a)
ACTION: 16AC
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 30 May 2019
Resolution: The crew replaced the old packing of the emergency fire pump with a new packing and the pump was operationally tested under pressure with satisfactory results. No leak was observed during the test. The ship is considered fit to sail.
Pollution Prevention/Response › Prevention Equipment › Incinerator, Shipboard
Issued 11 January 2012
Resolved
1499. The machinery shall be of a design and construction adequate for the service for which they were intended. The incinerator refractory material was found to be in disrepair. 74SOLAS(2001 cons), C.II-1, R.26.1 70c.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 6 June 2013
Resolution: Received technician report from [name withheld] attesting to repairs to incinerator. Verified repairs on board.
Navigation › Piloting/Steering › Marine Charts
Issued 9 February 2006
Resolved
On the local charts it was noted that they had been corrected and up to date in accordance with the local notice to mariner. However, upon further review we noted that some of the corrections were missing from the charts. Charts for the local area were to be corrected as soon as possible.
Action required: 17 - Rectify deficiencies prior to departure
Due 10 February 2006
Resolved 10 February 2006
Resolution: The charts were corrected by the Second Officer and verified by the Master.
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type II
Issued 9 February 2006
Resolved
The Marine Sanitation Device (MSD) is not being maintained in accordance with the manufacturer's requirements. Daily, weekly, monthly, semi annual and annual inspection of the system and its equipment is not being done.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 25 February 2006
Resolved 7 March 2006
Documentation › Safety/Response Plans/Programs › SOPEP
Issued 9 February 2006
Resolved
According to the ship's SOPEP appendix VI an annual review of the plan must be carried out. The last annual review of the plan was done in August of 2004. A review of the entire plan must be done and documented.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 25 February 2006
Resolved 9 February 2006
Electrical › Electric Generation Source (service) › Grounding Conductor
Issued 9 February 2006
Resolved
The electrical matting around the switchboards is in question. There isn't any documentation on board, which indicates the safe voltage rating of the matting. The company must supply documentation that would indicate that the matting meets SOLAS II-1 Reg. 40, 45-1.1 to 45-.2
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 25 February 2006
Resolved 7 March 2006