Inspection history · 13
31 May 2026
Internal Structural Exam · Administrative Inspection · Hull Examination · DAPI Audit · COI Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 8319452
1 June 2025
Administrative Inspection · DAPI Audit · Annual Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 8106658
2 June 2024
Annual Inspection · Administrative Inspection · DAPI Audit
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 7929951
4 June 2023
In-Service Inspection · Administrative Inspection · Annual Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 7684680
5 June 2022
Annual Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 7412347
6 June 2021
DAPI Audit · Drydock Exam · COI Inspection · Deficiency Check · Internal Structural Exam
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 7175753
7 October 2020
Administrative Inspection
Administrative · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 7073500
5 August 2020
Annual Inspection · Administrative Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 7024564
9 June 2019
Annual Inspection · DAPI Audit · Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 6690460
4 June 2018
Administrative Inspection · DAPI Audit · MARPOL Annex VI Survey · Annual Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 6429913
10 June 2017
Internal Structural Exam · Deficiency Check · Hull Examination · DAPI Audit · COI Inspection
Physical examination · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 6143039
2 July 2016
Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 5931706
1 April 2016
Deficiency Check · Administrative Inspection · Special · DAPI Audit · Annual Inspection
Physical examination · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 5847430
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 6 June 2021
Resolved
Replace worn turbo drain hose, engine sea suction from valve to strainer hose, and jacket water hose from trnamission cooler to engine exhaust.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 July 2021
Resolved 29 June 2021
Resolution: The deficiency was cleared to the satisfaction of an attending USCG Marine Inspector.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 6 June 2021
Resolved
Mark center console seating with life jacket quantity and type.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 July 2021
Resolved 29 June 2021
Resolution: The deficiency was cleared to the satisfaction of an attending USCG Marine Inspector.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 6 June 2021
Resolved
Replace ring buoy light battery.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 July 2021
Resolved 29 June 2021
Resolution: The deficiency was cleared to the satisfaction of an attending USCG Marine Inspector.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 6 June 2021
Resolved
Make permanant connections on battery leads and remove wing nuts.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 July 2021
Resolved 29 June 2021
Resolution: The deficiency was cleared to the satisfaction of an attending USCG Marine Inspector.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 9 June 2019
Resolved
Carry only 47 total persons until one type 1 PFD is replaced.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 July 2019
Resolved 8 July 2019
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 9 June 2019
Resolved
Replace the lower portion of engine room oil statured insulation.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 July 2019
Resolved 8 July 2019
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 9 June 2019
Resolved
Replace or cover the missing bow head vent.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 July 2019
Resolved 8 July 2019
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 9 June 2019
Resolved
Replace the life ring float light battery, the light was flashing extremely slow.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 July 2019
Resolved 8 July 2019
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 9 June 2019
Resolved
Ensure proper operation of the port running light and the forward mast head light.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 July 2019
Resolved 8 July 2019
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 9 June 2019
Resolved
Clean the vents on the alternator (oil soaked).
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 July 2019
Resolved 8 July 2019
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 9 June 2019
Resolved
Remove the abandon wires under the helm area.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 July 2019
Resolved 8 July 2019
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 9 June 2019
Resolved
Adjust the port rudder stop.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 July 2019
Resolved 17 July 2019
03 - Water/Weathertight Conditions › N/A - No Subsystem › Scuppers, inlets and discharges
Issued 9 June 2019
Resolved
Replace the forward stuffing tube box shaft T-clamp.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 July 2019
Resolved 17 July 2019
03 - Water/Weathertight Conditions › N/A - No Subsystem › Scuppers, inlets and discharges
Issued 9 June 2019
Resolved
Prior to the 2020 operating season, replace the shaft tube packing material.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 May 2020
Resolved 5 August 2020
Resolution: Cleared dificiency based on objective evidence submitted by owner. Shaft packing was found to be in sound condition but the seal had been overtightened. Shaft seal was reassembled and tightened appropriately.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 9 June 2019
Resolved
Prior to the 2020 operating season, ensure that all the conductors that originate at the positive terminal block have overcurrent protection.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 15 May 2020
Resolved 5 August 2020
Resolution: Received objective evidence from owner stating that he corrected the problem by correcting wiring error that occured when replacing battery switch.
Pollution Prevention/Response › Prevention Equipment › Means of Removal from within Coaming
Issued 4 June 2018
Resolved
Replace the oil soaked pads in the bilge and clean the bilge of excess oil residue.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 July 2018
Resolved 2 July 2018
Operations/Management › Drills/Instruction › Not Conducted
Issued 10 June 2017
Resolved
Prior to conducting passengers operations; provide documentation to the Coast Guard proving completion of man overboard and fire drills.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 10 July 2017
Resolved 10 July 2017
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 10 June 2017
Resolved
Prior to conducting passengers operations; verify proper operation of the installed fire suppression engine shut-down and over-ride function.
Action required: 701 - Prior to carriage of passengers/cargo
Due 10 July 2017
Resolved 10 July 2017
Engineering › Shafting/Propeller Arrangements › Propeller Shaft
Issued 10 June 2017
Resolved
Prior to conducting passengers operations; verify proper operation of the propulsion systems.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 10 July 2017
Resolved 10 July 2017
Engineering › Bilge Water Management System › Pump
Issued 10 June 2017
Resolved
Prior to conducting passengers operations; verify proper operation of the engine compartment bilge pump.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 10 July 2017
Resolved 10 July 2017
Electrical › Electrical Distribution System (service) › Wiring
Issued 10 June 2017
Resolved
Remove the abandoned wires, starboard side, forward, engine room void.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 July 2017
Resolved 10 July 2017
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 10 June 2017
Resolved
Repair or replace the lower entrance stair tread.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 July 2017
Resolved 10 July 2017
Engineering › Fuel Oil Service System › Hose
Issued 10 June 2017
Resolved
Replace the chafed MDE lower fuel supply hose with an appropriate hose rated to SAE J-1942 with fittings rated to J-1475.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 July 2017
Resolved 10 July 2017
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 10 June 2017
Resolved
Prior to opertaing at night, ensure proper operation of all the navigation lights.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 July 2017
Resolved 10 July 2017
Electrical › Lighting (service) › Lighting Branch Circuit
Issued 10 June 2017
Resolved
Ensure proper operation of interior cabin lighting.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 July 2017
Resolved 10 July 2017
Fire Fighting › Fire Bucket › Lanyard
Issued 10 June 2017
Resolved
Install whippings or properly secure the ends of the fire buckets lanyards. The lines are unlaying and all tangled up.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 July 2017
Resolved 10 July 2017
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 2 June 2016
Resolved
Carry only 45 adults until the condemned PFD’s are replaced.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 6 June 2016
Resolved 3 June 2016
Resolution: Replaced
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 2 June 2016
Resolved
Replace the frayed life ring float light lanyard with a 3-6’ buoyant line with a clip attached.
Condition: Improper/Lack of Maintenance
Due 2 July 2016
Resolved 2 July 2016
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 2 June 2016
Resolved
Replace one piece on the damaged reto on the life ring.
Condition: Improper/Lack of Maintenance
Due 2 July 2016
Resolved 2 July 2016
Electrical › Electric Supply System (service) › Battery Installation
Issued 2 June 2016
Resolved
Cover the exposed battery terminals.
Condition: Improper Installation
Due 2 July 2016
Resolved 2 July 2016
Lifesaving › Embarkation Appliances/Stations › Steps
Issued 2 June 2016
Resolved
Install a Jacobs’s ladder for use with a single Master MOB recovery.
Condition: Improper Installation
Due 2 July 2016
Resolved 2 July 2016
Resolution: Photo
Engineering › Engine Controls (Electric/Electronic) › Linkage
Issued 2 June 2016
Resolved
Properly secure the throttle control housing base, screws are loose.
Condition: Improper/Lack of Maintenance
Due 2 July 2016
Resolved 2 July 2016