MAURY USCG vessel records
← All vessels

BELLE

Built
1987
Last inspected
31 May 2026
Documentation
Case Pending · NVDC file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 31 May 2026
Operational controls None recorded without a removal date
Years with a record 11 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

292082
Flag
UNITED STATES
Maury page id
psix-292082

Documentation record

Registered dimensions (L × B × D)36.0 ft × 16.0 ft × 6.2 ft
Registered tonnagegross 23 / net 19
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderHUENEME BOAT WORKS · PORT HUENEME, CA, UNITED STATES · built 1987
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portCODY, WY
Endorsements, as the file codes themcw_un
DocumentationCase Pending · issued 25 April 2025 · expires 31 May 2026
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it23 - Simplified, Gross Ton
19 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
The full record for this vessel

Behind this panel: 13 inspections, each with its date, unit and type; 32 deficiencies with the resolution recorded against each; operational controls, none recorded without a removal date; no tow-unit appearances recorded; no other recorded names; the documentation record: dimensions, tonnage, builder, hailing port and endorsements. Every line is a record the Coast Guard wrote; the counts above are the same counts as in the summary, and they are free.

Professional is $39 a month or $299 a year, or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks every detail section on every vessel page, fleet watch tied to your account, and ownership records on request. Already a subscriber? Sign in.

Maury does not score, rate or grade vessels, at any price.

Vessel history report

A report is not offered for this hull. Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 13

31 May 2026 Internal Structural Exam · Administrative Inspection · Hull Examination · DAPI Audit · COI Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 8319452
1 June 2025 Administrative Inspection · DAPI Audit · Annual Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 8106658
2 June 2024 Annual Inspection · Administrative Inspection · DAPI Audit
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 7929951
4 June 2023 In-Service Inspection · Administrative Inspection · Annual Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 7684680
5 June 2022 Annual Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 7412347
6 June 2021 DAPI Audit · Drydock Exam · COI Inspection · Deficiency Check · Internal Structural Exam
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 7175753
7 October 2020 Administrative Inspection
Administrative · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 7073500
5 August 2020 Annual Inspection · Administrative Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 7024564
9 June 2019 Annual Inspection · DAPI Audit · Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 6690460
4 June 2018 Administrative Inspection · DAPI Audit · MARPOL Annex VI Survey · Annual Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 6429913
10 June 2017 Internal Structural Exam · Deficiency Check · Hull Examination · DAPI Audit · COI Inspection
Physical examination · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 6143039
2 July 2016 Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 5931706
1 April 2016 Deficiency Check · Administrative Inspection · Special · DAPI Audit · Annual Inspection
Physical examination · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 5847430

Deficiency record · 32

13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 6 June 2021 Resolved
Replace worn turbo drain hose, engine sea suction from valve to strainer hose, and jacket water hose from trnamission cooler to engine exhaust.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 July 2021
Resolved 29 June 2021
Resolution: The deficiency was cleared to the satisfaction of an attending USCG Marine Inspector.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 6 June 2021 Resolved
Mark center console seating with life jacket quantity and type.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 July 2021
Resolved 29 June 2021
Resolution: The deficiency was cleared to the satisfaction of an attending USCG Marine Inspector.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 6 June 2021 Resolved
Replace ring buoy light battery.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 July 2021
Resolved 29 June 2021
Resolution: The deficiency was cleared to the satisfaction of an attending USCG Marine Inspector.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 6 June 2021 Resolved
Make permanant connections on battery leads and remove wing nuts.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 July 2021
Resolved 29 June 2021
Resolution: The deficiency was cleared to the satisfaction of an attending USCG Marine Inspector.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 9 June 2019 Resolved
Carry only 47 total persons until one type 1 PFD is replaced.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 July 2019
Resolved 8 July 2019
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 9 June 2019 Resolved
Replace the lower portion of engine room oil statured insulation.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 July 2019
Resolved 8 July 2019
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 9 June 2019 Resolved
Replace or cover the missing bow head vent.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 July 2019
Resolved 8 July 2019
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 9 June 2019 Resolved
Replace the life ring float light battery, the light was flashing extremely slow.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 July 2019
Resolved 8 July 2019
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 9 June 2019 Resolved
Ensure proper operation of the port running light and the forward mast head light.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 July 2019
Resolved 8 July 2019
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 9 June 2019 Resolved
Clean the vents on the alternator (oil soaked).
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 July 2019
Resolved 8 July 2019
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 9 June 2019 Resolved
Remove the abandon wires under the helm area.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 July 2019
Resolved 8 July 2019
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 9 June 2019 Resolved
Adjust the port rudder stop.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 July 2019
Resolved 17 July 2019
03 - Water/Weathertight Conditions › N/A - No Subsystem › Scuppers, inlets and discharges
Issued 9 June 2019 Resolved
Replace the forward stuffing tube box shaft T-clamp.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 July 2019
Resolved 17 July 2019
03 - Water/Weathertight Conditions › N/A - No Subsystem › Scuppers, inlets and discharges
Issued 9 June 2019 Resolved
Prior to the 2020 operating season, replace the shaft tube packing material.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 May 2020
Resolved 5 August 2020
Resolution: Cleared dificiency based on objective evidence submitted by owner. Shaft packing was found to be in sound condition but the seal had been overtightened. Shaft seal was reassembled and tightened appropriately.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 9 June 2019 Resolved
Prior to the 2020 operating season, ensure that all the conductors that originate at the positive terminal block have overcurrent protection.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 15 May 2020
Resolved 5 August 2020
Resolution: Received objective evidence from owner stating that he corrected the problem by correcting wiring error that occured when replacing battery switch.
Pollution Prevention/Response › Prevention Equipment › Means of Removal from within Coaming
Issued 4 June 2018 Resolved
Replace the oil soaked pads in the bilge and clean the bilge of excess oil residue.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 July 2018
Resolved 2 July 2018
Operations/Management › Drills/Instruction › Not Conducted
Issued 10 June 2017 Resolved
Prior to conducting passengers operations; provide documentation to the Coast Guard proving completion of man overboard and fire drills.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 10 July 2017
Resolved 10 July 2017
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 10 June 2017 Resolved
Prior to conducting passengers operations; verify proper operation of the installed fire suppression engine shut-down and over-ride function.
Action required: 701 - Prior to carriage of passengers/cargo
Due 10 July 2017
Resolved 10 July 2017
Engineering › Shafting/Propeller Arrangements › Propeller Shaft
Issued 10 June 2017 Resolved
Prior to conducting passengers operations; verify proper operation of the propulsion systems.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 10 July 2017
Resolved 10 July 2017
Engineering › Bilge Water Management System › Pump
Issued 10 June 2017 Resolved
Prior to conducting passengers operations; verify proper operation of the engine compartment bilge pump.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 10 July 2017
Resolved 10 July 2017
Electrical › Electrical Distribution System (service) › Wiring
Issued 10 June 2017 Resolved
Remove the abandoned wires, starboard side, forward, engine room void.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 July 2017
Resolved 10 July 2017
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 10 June 2017 Resolved
Repair or replace the lower entrance stair tread.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 July 2017
Resolved 10 July 2017
Engineering › Fuel Oil Service System › Hose
Issued 10 June 2017 Resolved
Replace the chafed MDE lower fuel supply hose with an appropriate hose rated to SAE J-1942 with fittings rated to J-1475.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 July 2017
Resolved 10 July 2017
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 10 June 2017 Resolved
Prior to opertaing at night, ensure proper operation of all the navigation lights.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 July 2017
Resolved 10 July 2017
Electrical › Lighting (service) › Lighting Branch Circuit
Issued 10 June 2017 Resolved
Ensure proper operation of interior cabin lighting.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 July 2017
Resolved 10 July 2017
Fire Fighting › Fire Bucket › Lanyard
Issued 10 June 2017 Resolved
Install whippings or properly secure the ends of the fire buckets lanyards. The lines are unlaying and all tangled up.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 July 2017
Resolved 10 July 2017
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 2 June 2016 Resolved
Carry only 45 adults until the condemned PFD’s are replaced.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 6 June 2016
Resolved 3 June 2016
Resolution: Replaced
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 2 June 2016 Resolved
Replace the frayed life ring float light lanyard with a 3-6’ buoyant line with a clip attached.
Condition: Improper/Lack of Maintenance
Due 2 July 2016
Resolved 2 July 2016
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 2 June 2016 Resolved
Replace one piece on the damaged reto on the life ring.
Condition: Improper/Lack of Maintenance
Due 2 July 2016
Resolved 2 July 2016
Electrical › Electric Supply System (service) › Battery Installation
Issued 2 June 2016 Resolved
Cover the exposed battery terminals.
Condition: Improper Installation
Due 2 July 2016
Resolved 2 July 2016
Lifesaving › Embarkation Appliances/Stations › Steps
Issued 2 June 2016 Resolved
Install a Jacobs’s ladder for use with a single Master MOB recovery.
Condition: Improper Installation
Due 2 July 2016
Resolved 2 July 2016
Resolution: Photo
Engineering › Engine Controls (Electric/Electronic) › Linkage
Issued 2 June 2016 Resolved
Properly secure the throttle control housing base, screws are loose.
Condition: Improper/Lack of Maintenance
Due 2 July 2016
Resolved 2 July 2016

Ownership record